Allen-Bradley 1746-IO12 SLC 500 Digital I/O Combination Module

متوفر في المخزون
Manufacturer:
Allen-Bradley
Product No.:
1746-IO12
Condition:
In Stock
Product Type:
Digital I/O Combination Module
Product Origin:
USA
Weight:
500g
Shipping port:
Xiamen
Warranty:
12 months

يوبيست – مورد عالمي موثوق لقطع غيار الأتمتة

نقدم مجموعة واسعة من قطع غيار الأتمتة الصناعية المتوفرة في المخزون. جميع المنتجات تأتي مع ضمان لمدة 12 شهرًا واسترداد خلال 30 يومًا لمشاكل الجودة.

معلومات عنا | اتصل بنا

Allen-Bradley 1746-IO12 Digital I/O Combination Module

Quick Overview

The Allen-Bradley 1746-IO12 combines 6 AC inputs and 6 relay outputs in one compact module. Perfect for space-saving control applications in SLC 500 systems.

Key Benefits

6 AC inputs (85-132V AC)

6 relay outputs (24-125V DC / 120-240V AC)

• Single slot design saves space

• Relay contacts: Normally Open type

• Hazardous location certified

Detailed Specifications

Input Channels: 6 points

Input Voltage: 85-132V AC

Output Channels: 6 relay points

Output Rating: 1.5A @ 120V AC, 1.2A @ 24V DC

Max Current: 2.0A continuous

Response Time: 35-45 milliseconds

Backplane Current: 70-90 mA

Heat Dissipation: 4.60W total

Isolation Rating: 1500V

Operating Temp: 0-60°C (32-140°F)

Storage Temp: -40 to 85°C (-40 to 185°F)

Vibration: 2.5G @ 57-200Hz

Shock Resistance: 30G operational

Installation Notes

The 1746-IO12 module fits any slot in SLC 500 chassis. It works with all SLC 500 processors. Easy installation with standard tools.

Safety Certifications

Certified for Class 1, Division 2 hazardous locations. Meets NEMA noise immunity standards.

Warranty & Shipping

12-month warranty included. We ship worldwide via FedEx, UPS, and DHL.

Expert Questions Answered

What type of relay contacts does it use?

Form A contacts (Normally Open) for all 6 outputs.

What is the maximum output power?

28VA maximum output power capacity.

Can it handle DC and AC loads?

Yes, outputs work with both AC (120-240V) and DC (24-125V) loads.

What is the isolation voltage?

1500V isolation between I/O and control logic.

Is it suitable for harsh environments?

Yes, operates in 5-95% humidity without condensation.

Get Complete Documentation

  • Full installation guide
  • Wiring diagrams
  • Technical specifications
  • Application examples
  • Troubleshooting tips

Download the complete SLC 500 manual: Download Manual PDF

© 2025 Ubest Automation Limited. All rights reserved.