{"product_id":"bently-nevada-330190-075-00-cn-armored-etr-cable-3300-xl","title":"Bently Nevada 330190-075-00-CN Armored ETR Cable | 3300 XL","description":"\u003ch2\u003eBently Nevada 330190-075-00-CN Armored ETR Cable\u003c\/h2\u003e\n\u003cp\u003eEngineered for extreme conditions, this \u003cstrong\u003e3300 XL\u003c\/strong\u003e armored extension cable provides maximum durability. The \u003cstrong\u003e330190-075-00-CN\u003c\/strong\u003e combines mechanical protection with precise signal transmission for critical monitoring applications.\u003c\/p\u003e\n\u003ch3\u003eProduct Overview \u0026amp; Key Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eManufacturer: \u003cspan style=\"color: #2e86ab;\"\u003eBently Nevada\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eProduct Series: \u003cstrong\u003e3300 XL\u003c\/strong\u003e Vibration Monitoring System\u003c\/li\u003e\n\u003cli\u003eModel Number: \u003cstrong\u003e330190-075-00-CN\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eCable Type: Armored Extended Temperature Range (ETR)\u003c\/li\u003e\n\u003cli\u003eConstruction: 75Ω Triaxial with PFA Insulation\u003c\/li\u003e\n\u003cli\u003eArmor Material: Corrugated stainless steel for crush protection\u003c\/li\u003e\n\u003cli\u003eJacket Material: Polyurethane for abrasion resistance\u003c\/li\u003e\n\u003cli\u003eCountry Approval: CN specific certification included\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical Performance Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCenter Conductor Resistance: \u003cspan style=\"color: #2e86ab;\"\u003e1.65 Ω ± 0.25\u003c\/span\u003e at 20°C\u003c\/li\u003e\n\u003cli\u003eOuter Shield Resistance: \u003cspan style=\"color: #2e86ab;\"\u003e0.49 Ω ± 0.10\u003c\/span\u003e at 20°C\u003c\/li\u003e\n\u003cli\u003eCapacitance Core-to-Shield: 69.9 pF\/m typical\u003c\/li\u003e\n\u003cli\u003eCharacteristic Impedance: 75Ω ±5% from 1-100 MHz\u003c\/li\u003e\n\u003cli\u003eDielectric Withstanding Voltage: 1500 Vrms for 60 seconds\u003c\/li\u003e\n\u003cli\u003eInsulation Resistance: ≥5000 MΩ per kilometer at 500 VDC\u003c\/li\u003e\n\u003cli\u003eSignal Bandwidth: DC to 15 kHz (-3 dB point)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMechanical \u0026amp; Physical Properties\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCable Length: 7.5 meters (24.6 feet) exact length\u003c\/li\u003e\n\u003cli\u003eCable Outer Diameter: 6.2 mm with armor protection\u003c\/li\u003e\n\u003cli\u003eMinimum Bend Radius: 50 mm (2.0 inches) under tension\u003c\/li\u003e\n\u003cli\u003eCable Weight: 103 g\/m (1.5 oz\/ft) armored version\u003c\/li\u003e\n\u003cli\u003eConnector Type: Gold-plated triaxial 8mm design\u003c\/li\u003e\n\u003cli\u003eMating Cycles: ≥500 cycles without performance degradation\u003c\/li\u003e\n\u003cli\u003eCrush Resistance: Withstands 2000 N\/cm crushing force\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental \u0026amp; Operating Conditions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTemperature Range: -52°C to +260°C continuous operation\u003c\/li\u003e\n\u003cli\u003eThermal Cycling: 1000 cycles from -55°C to +260°C\u003c\/li\u003e\n\u003cli\u003eHumidity Resistance: 95% RH at 65°C for 1000 hours\u003c\/li\u003e\n\u003cli\u003eOil Resistance: Compatible with lubricating oils and fuels\u003c\/li\u003e\n\u003cli\u003eChemical Resistance: Resists acids, alkalis, and solvents\u003c\/li\u003e\n\u003cli\u003eFlame Rating: IEC 60332-1-2 flame retardant certified\u003c\/li\u003e\n\u003cli\u003eUV Resistance: Suitable for outdoor installation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMeasurement System Performance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eLinear Range: 0.25 mm to 2.3 mm from target surface\u003c\/li\u003e\n\u003cli\u003eRecommended Gap: 1.27 mm (50 mils) for -9 VDC output\u003c\/li\u003e\n\u003cli\u003eSystem Sensitivity: 7.87 V\/mm (200 mV\/mil) standard\u003c\/li\u003e\n\u003cli\u003eNonlinearity: \u0026lt;±1% over entire linear range\u003c\/li\u003e\n\u003cli\u003eTemperature Coefficient: ±0.05%\/°C over operating range\u003c\/li\u003e\n\u003cli\u003eHysteresis: \u0026lt;0.5% of full scale output\u003c\/li\u003e\n\u003cli\u003eResolution: Better than 0.1 μm (4 μinches)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Requirements\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eField Wiring: 0.2 to 1.5 mm² (16-24 AWG) shielded triad\u003c\/li\u003e\n\u003cli\u003eMaximum Distance: 305 meters between sensor and monitor\u003c\/li\u003e\n\u003cli\u003eWiring Preparation: Use tinned copper conductors only\u003c\/li\u003e\n\u003cli\u003eShielding: Continuous 360° shield termination required\u003c\/li\u003e\n\u003cli\u003eGrounding: Single-point ground at monitor location\u003c\/li\u003e\n\u003cli\u003eSeparation: Keep 300 mm from power cables\u003c\/li\u003e\n\u003cli\u003eStrain Relief: Provide within 150 mm of connector\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance \u0026amp; Safety Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFunctional Safety: SIL 2 (HFT=0) and SIL 3 (HFT=1) capable\u003c\/li\u003e\n\u003cli\u003eEMC Immunity: EN 61000-6-2 for industrial environments\u003c\/li\u003e\n\u003cli\u003eEMC Emissions: EN 61000-6-4 Class A requirements\u003c\/li\u003e\n\u003cli\u003eMaritime Approval: ABS, DNV, LR, and BV certified\u003c\/li\u003e\n\u003cli\u003eRoHS Compliance: 2011\/65\/EU without exemptions\u003c\/li\u003e\n\u003cli\u003eVibration Test: IEC 60068-2-6, 10g, 10-2000 Hz\u003c\/li\u003e\n\u003cli\u003eShock Test: IEC 60068-2-27, 50g, 11 ms duration\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eShipping \u0026amp; Delivery Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePackaging: Individual protective tube with end caps\u003c\/li\u003e\n\u003cli\u003eDocumentation: Includes test certificate and data sheet\u003c\/li\u003e\n\u003cli\u003eShipping Methods: FedEx, UPS, DHL express available\u003c\/li\u003e\n\u003cli\u003eLead Time: Standard stock to 4 weeks for reliability\u003c\/li\u003e\n\u003cli\u003eOrder Verification: Includes serialized test records\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Support FAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eWhat advantage does armored cable provide over standard?\u003c\/li\u003e\n\u003cli\u003eArmored construction adds crush protection and durability in harsh plants.\u003c\/li\u003e\n\u003cli\u003eCan this cable withstand direct burial applications?\u003c\/li\u003e\n\u003cli\u003eNo, the armored version needs conduit for direct burial installation.\u003c\/li\u003e\n\u003cli\u003eWhat maintenance does this extension cable require?\u003c\/li\u003e\n\u003cli\u003eRegular inspection for physical damage and connector integrity checks.\u003c\/li\u003e\n\u003cli\u003eHow does temperature affect cable resistance values?\u003c\/li\u003e\n\u003cli\u003eResistance increases approximately 0.4% per °C temperature rise.\u003c\/li\u003e\n\u003cli\u003eWhat tools are needed for proper connector installation?\u003c\/li\u003e\n\u003cli\u003eUse torque wrench and proper triaxial connector tool kit only.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e© 2025 Ubest Automation Limited. All rights reserved.\u003cbr\u003eOriginal Source: \u003ca href=\"https:\/\/www.ubestplc.com\/\"\u003ehttps:\/\/www.ubestplc.com\/\u003c\/a\u003e\u003cbr\u003eContact: \u003ca href=\"mailto:sales@ubestplc.com\"\u003esales@ubestplc.com\u003c\/a\u003e Phone: \u003ca href=\"https:\/\/wa.me\/868618030005825\"\u003e+86 86 180 3000 5825\u003c\/a\u003e\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":51226080117018,"sku":null,"price":168.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/330190-075-01-CN.jpg?v=1761013593","url":"https:\/\/www.ubestplc.com\/ar\/products\/bently-nevada-330190-075-00-cn-armored-etr-cable-3300-xl","provider":"Ubest Automation Limited","version":"1.0","type":"link"}