{"product_id":"ge-exciter-attenuation-module-ex2100e-system-is200examg1baa","title":"GE Exciter Attenuation Module | EX2100e System IS200EXAMG1BAA","description":"\u003ch2\u003eGE EX2100e Exciter Attenuation Module IS200EXAMG1BAA\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eIS200EXAMG1BAA\u003c\/strong\u003e represents General Electric's advanced solution for excitation system protection. This Exciter Attenuation Module delivers critical ground fault detection capabilities within the EX2100e excitation control system, ensuring generator shaft protection through sophisticated voltage monitoring and signal conditioning.\u003c\/p\u003e\n\u003ch3\u003eCore Technical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e74b5;\"\u003eManufacturer\u003c\/span\u003e: General Electric\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e74b5;\"\u003eModel Number\u003c\/span\u003e: \u003cstrong\u003eIS200EXAMG1BAA\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e74b5;\"\u003eProduct Type\u003c\/span\u003e: Exciter Attenuation Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e74b5;\"\u003eOperating Temperature\u003c\/span\u003e: 0°C to 60°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e74b5;\"\u003eSeries Compatibility\u003c\/span\u003e: EX2100e Excitation System\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e74b5;\"\u003eAttenuation Range\u003c\/span\u003e: 1000:1 Voltage Scaling Ratio\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e74b5;\"\u003eFrequency Response\u003c\/span\u003e: 1Hz to 10kHz Operating Bandwidth\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e74b5;\"\u003eInput Voltage Range\u003c\/span\u003e: 0-600V AC\/DC Field Bus Voltage\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e74b5;\"\u003eOutput Voltage Range\u003c\/span\u003e: 0-0.6V Scaled Measurement Signal\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e74b5;\"\u003eInsulation Resistance\u003c\/span\u003e: \u0026gt;100MΩ at 500V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e74b5;\"\u003eDielectric Strength\u003c\/span\u003e: 2000V AC for 1 Minute\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Configuration \u0026amp; Connectors\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eJ1: 3-pin locking connector for field flashing relay interface\u003c\/li\u003e\n\u003cli\u003eJ2: 9-pin D-sub connector for test signals and relay control\u003c\/li\u003e\n\u003cli\u003eE1 \u0026amp; E2: Stab-on connectors for field bus voltage input\u003c\/li\u003e\n\u003cli\u003eTB1: Shield ground terminal for cabinet chassis connection\u003c\/li\u003e\n\u003cli\u003eJP1, JP2, JP3: Configurable jumpers for PPT secondary voltages\u003c\/li\u003e\n\u003cli\u003eMounting: Designed for High Voltage Interface (HVI) module installation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical Characteristics \u0026amp; Performance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSignal Attenuation: Precisely scales high voltage to measurable levels\u003c\/li\u003e\n\u003cli\u003eGround Detection: Collaborates with EGDM for fault identification\u003c\/li\u003e\n\u003cli\u003eVoltage Compatibility: 120V\/240V PPT secondary voltage options\u003c\/li\u003e\n\u003cli\u003eComponent Quality: Features twenty precision wire-wound resistors\u003c\/li\u003e\n\u003cli\u003eProtection: Includes two metal oxide varistors for surge suppression\u003c\/li\u003e\n\u003cli\u003eRelay: Single high-capacity relay for control operations\u003c\/li\u003e\n\u003cli\u003eCapacitors: Four large polyester-vinyl capacitors for filtering\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation \u0026amp; System Integration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the module within the High Voltage Interface cabinet section\u003c\/li\u003e\n\u003cli\u003eConnect field bus voltages using E1 and E2 stab-on connectors\u003c\/li\u003e\n\u003cli\u003eEstablish ground connection through TB1 terminal point\u003c\/li\u003e\n\u003cli\u003eConfigure JP1-JP3 jumpers according to your PPT voltage requirements\u003c\/li\u003e\n\u003cli\u003eConnect 9-pin cable between EXAM and Exciter Power Backplane\u003c\/li\u003e\n\u003cli\u003eInterface with EGDM or EROC based on your system configuration\u003c\/li\u003e\n\u003cli\u003eVerify all connections before applying power to the system\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSystem Compatibility \u0026amp; Applications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEX2100e Excitation Control System integration\u003c\/li\u003e\n\u003cli\u003eWorks with Exciter Ground Detector Module (EGDM)\u003c\/li\u003e\n\u003cli\u003eCompatible with Exciter\/Regulator Options Board (EROC)\u003c\/li\u003e\n\u003cli\u003eSupports simplex and triple modular redundant configurations\u003c\/li\u003e\n\u003cli\u003eStandalone PGDM ground detector product applications\u003c\/li\u003e\n\u003cli\u003eInterface with BGTB, BFGD, and BPPB processor boards\u003c\/li\u003e\n\u003cli\u003eDigital Signal Processor Control Board (DSPX) computational support\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePackaging \u0026amp; Shipping Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIncludes one GE \u003cstrong\u003eIS200EXAMG1BAA\u003c\/strong\u003e Exciter Attenuation Module\u003c\/li\u003e\n\u003cli\u003eProtected by anti-static packaging materials\u003c\/li\u003e\n\u003cli\u003eSecure cardboard boxing with protective cushioning\u003c\/li\u003e\n\u003cli\u003eGlobal shipping via FedEx, UPS, and DHL express services\u003c\/li\u003e\n\u003cli\u003eReal-time tracking information provided upon dispatch\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWarranty \u0026amp; Support\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e12-month comprehensive warranty from delivery date\u003c\/li\u003e\n\u003cli\u003eCovers manufacturing defects and component failures\u003c\/li\u003e\n\u003cli\u003eProfessional technical support available\u003c\/li\u003e\n\u003cli\u003eReplacement service for warranted claims\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProfessional FAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eWhat is the primary function of this module in the EX2100e system?\u003c\/li\u003e\n\u003cli\u003eThe module provides essential ground fault detection and voltage attenuation between field bus components and ground detection systems.\u003c\/li\u003e\n\u003cli\u003eHow does the module handle different voltage input levels?\u003c\/li\u003e\n\u003cli\u003eConfigurable jumpers JP1-JP3 allow adaptation to various PPT secondary voltages including 120V and 240V configurations.\u003c\/li\u003e\n\u003cli\u003eCan this module operate in redundant system configurations?\u003c\/li\u003e\n\u003cli\u003eYes, it supports both simplex and triple modular redundant systems while maintaining consistent interconnection standards.\u003c\/li\u003e\n\u003cli\u003eWhat type of connectors does the module feature for field bus connection?\u003c\/li\u003e\n\u003cli\u003eIt utilizes stab-on connectors E1 and E2 for direct field bus voltage interface and secure electrical connection.\u003c\/li\u003e\n\u003cli\u003eHow does the module contribute to generator protection?\u003c\/li\u003e\n\u003cli\u003eIt drives the field winding electrical center with low-frequency AC voltage to detect ground paths from exciter components.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e© 2025 Ubest Automation Limited. All rights reserved.\u003cbr\u003eOriginal Source: \u003ca href=\"https:\/\/www.ubestplc.com\/\"\u003ehttps:\/\/www.ubestplc.com\/\u003c\/a\u003e\u003cbr\u003eContact: \u003ca href=\"mailto:sales@ubestplc.com\"\u003esales@ubestplc.com\u003c\/a\u003e Phone: \u003ca href=\"https:\/\/wa.me\/8618030005825\"\u003e+86 180 3000 5825\u003c\/a\u003e\u003c\/p\u003e","brand":"GE","offers":[{"title":"Default Title","offer_id":51248065282330,"sku":"IS200EXAMG1BAA","price":173.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/IS200EXAMG1BAA.jpg?v=1761267055","url":"https:\/\/www.ubestplc.com\/ar\/products\/ge-exciter-attenuation-module-ex2100e-system-is200examg1baa","provider":"Ubest Automation Limited","version":"1.0","type":"link"}