{"product_id":"ge-contact-input-board-mark-vi-terminal-is200stcih2aed","title":"GE Contact Input Board | Mark VI Terminal IS200STCIH2AED","description":"\u003ch2\u003eGE IS200STCIH2AED Simplex Contact Input Terminal Board for Mark VI Systems\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eIS200STCIH2AED\u003c\/strong\u003e provides reliable contact input processing for General Electric's Mark VI control systems. This compact terminal board offers versatile mounting options and robust signal conditioning. It ensures accurate contact sensing with comprehensive noise protection for industrial environments.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications \u0026amp; Performance Data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e74b5;\"\u003e\u003cb\u003eManufacturer:\u003c\/b\u003e\u003c\/span\u003e General Electric\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e74b5;\"\u003e\u003cb\u003eModel Number:\u003c\/b\u003e\u003c\/span\u003e \u003cstrong\u003eIS200STCIH2AED\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e74b5;\"\u003e\u003cb\u003eProduct Type:\u003c\/b\u003e\u003c\/span\u003e Simplex Contact Input Terminal Board\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e74b5;\"\u003e\u003cb\u003eControl System Series:\u003c\/b\u003e\u003c\/span\u003e Mark VI\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e74b5;\"\u003e\u003cb\u003eInput Channels:\u003c\/b\u003e\u003c\/span\u003e 24 dry contact voltage inputs\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e74b5;\"\u003e\u003cb\u003eExcitation Voltages:\u003c\/b\u003e\u003c\/span\u003e 24V, 48V, 125V DC nominal\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e74b5;\"\u003e\u003cb\u003eVoltage Ranges:\u003c\/b\u003e\u003c\/span\u003e 16-32V, 32-64V, 100-145V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e74b5;\"\u003e\u003cb\u003eThreshold Voltage:\u003c\/b\u003e\u003c\/span\u003e 50% of excitation voltage\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e74b5;\"\u003e\u003cb\u003eCurrent Consumption:\u003c\/b\u003e\u003c\/span\u003e 2.5mA (channels 1-21), 10mA (22-24)\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e74b5;\"\u003e\u003cb\u003ePower Supply:\u003c\/b\u003e\u003c\/span\u003e 24V DC with 0.5A current limiting\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e74b5;\"\u003e\u003cb\u003eFilter Response:\u003c\/b\u003e\u003c\/span\u003e 4ms hardware filtering\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e74b5;\"\u003e\u003cb\u003eTerminal Capacity:\u003c\/b\u003e\u003c\/span\u003e 52-position pluggable terminal block\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e74b5;\"\u003e\u003cb\u003eWire Size:\u003c\/b\u003e\u003c\/span\u003e #18 AWG recommended\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e74b5;\"\u003e\u003cb\u003eOperating Temperature:\u003c\/b\u003e\u003c\/span\u003e -20°C to +70°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e74b5;\"\u003e\u003cb\u003eIsolation Rating:\u003c\/b\u003e\u003c\/span\u003e 1500V input-to-output\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eContact Input Configuration \u0026amp; Excitation\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTwenty-four dry contact inputs support various voltage levels\u003c\/li\u003e\n\u003cli\u003eThree excitation voltage options provide application flexibility\u003c\/li\u003e\n\u003cli\u003eAutomatic threshold detection at 50% of excitation voltage\u003c\/li\u003e\n\u003cli\u003eDifferential current consumption optimizes power usage\u003c\/li\u003e\n\u003cli\u003eReset-table polymer fuses provide overcurrent protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eNoise Suppression \u0026amp; Signal Protection\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAdvanced filtering reduces high-frequency noise interference\u003c\/li\u003e\n\u003cli\u003eSurge suppression protects inputs from voltage transients\u003c\/li\u003e\n\u003cli\u003eHardware filtering ensures stable 4ms response timing\u003c\/li\u003e\n\u003cli\u003eShield termination brackets minimize electromagnetic interference\u003c\/li\u003e\n\u003cli\u003eRobust signal conditioning maintains data integrity\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMounting \u0026amp; Installation Options\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDIN-rail mounting provides quick industrial installation\u003c\/li\u003e\n\u003cli\u003eFlat surface mounting offers alternative installation method\u003c\/li\u003e\n\u003cli\u003eSheet metal carrier ensures secure mechanical attachment\u003c\/li\u003e\n\u003cli\u003ePlastic insulator maintains proper electrical isolation\u003c\/li\u003e\n\u003cli\u003eRight-angle header accepts standard pluggable terminal blocks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCommunication \u0026amp; System Integration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThirty-seven pin D-type connector interfaces with PAIC I\/O packs\u003c\/li\u003e\n\u003cli\u003eThree-position female plug supports additional connections\u003c\/li\u003e\n\u003cli\u003eEthernet communication enables controller data exchange\u003c\/li\u003e\n\u003cli\u003eSimplex system architecture ensures reliable operation\u003c\/li\u003e\n\u003cli\u003eCompatible with IS230STCI and IS230SNCI system components\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Design \u0026amp; Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFifty-two terminal positions accommodate comprehensive wiring\u003c\/li\u003e\n\u003cli\u003eRight-angle header design optimizes space utilization\u003c\/li\u003e\n\u003cli\u003eOver eighty resistors, capacitors, and diodes ensure signal integrity\u003c\/li\u003e\n\u003cli\u003eIntegrated circuit provides sophisticated signal processing\u003c\/li\u003e\n\u003cli\u003eDual round apertures facilitate secure mounting procedures\u003c\/li\u003e\n\u003cli\u003eConformal coating protects against environmental contaminants\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation \u0026amp; Wiring Procedures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the board on DIN rail using provided sheet metal carrier\u003c\/li\u003e\n\u003cli\u003eInstall plastic insulator for proper electrical isolation\u003c\/li\u003e\n\u003cli\u003eConnect #18 AWG wires directly to terminal block positions\u003c\/li\u003e\n\u003cli\u003eTerminate shields on separate bracket for noise reduction\u003c\/li\u003e\n\u003cli\u003eConnect PAIC I\/O pack to 37-pin D-type connector interface\u003c\/li\u003e\n\u003cli\u003eVerify excitation voltage matches application requirements\u003c\/li\u003e\n\u003cli\u003eTest all 24 contact inputs for proper response and threshold\u003c\/li\u003e\n\u003cli\u003eValidate noise suppression and filtering functionality\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFault Detection \u0026amp; Diagnostics\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eExcitation voltage loss detection alerts to power issues\u003c\/li\u003e\n\u003cli\u003eContact input response testing validates proper operation\u003c\/li\u003e\n\u003cli\u003eCurrent monitoring ensures within-specification performance\u003c\/li\u003e\n\u003cli\u003eFilter functionality verification maintains signal quality\u003c\/li\u003e\n\u003cli\u003eContinuous health monitoring provides operational assurance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePackaging \u0026amp; Shipping Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFactory-new \u003cstrong\u003eIS200STCIH2AED\u003c\/strong\u003e terminal board\u003c\/li\u003e\n\u003cli\u003eComplete mounting hardware and installation accessories\u003c\/li\u003e\n\u003cli\u003eProfessional documentation with wiring diagrams\u003c\/li\u003e\n\u003cli\u003eGlobal express shipping via FedEx, UPS, and DHL available\u003c\/li\u003e\n\u003cli\u003eSecure packaging ensures perfect condition upon arrival\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eExpert Technical Support\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cb\u003eWhat excitation voltage options does the terminal board support?\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003eThe board accepts 24V DC (16-32V range), 48V DC (32-64V range), and 125V DC (100-145V range) excitation sources with automatic threshold detection at 50%\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003eHow many contact inputs are available and what are their specifications?\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003eTwenty-four dry contact inputs include twenty-one circuits at 2.5mA and three circuits at 10mA current consumption with 4ms hardware filtering\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003eWhat mounting options are available for this terminal board?\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003eThe board supports both DIN-rail mounting using a sheet metal carrier and flat surface mounting with plastic insulator for electrical isolation\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003eWhat noise protection features are incorporated?\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003eAdvanced surge suppression, high-frequency noise filtering, and separate shield termination provide comprehensive protection against electrical interference\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003eWhich I\/O packs are compatible with this terminal board?\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003eThe board interfaces with PAIC I\/O packs through a 37-pin D-type connector and is compatible with IS230STCI and IS230SNCI system components\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e© 2025 Ubest Automation Limited. All rights reserved.\u003cbr\u003eOriginal Source: \u003ca href=\"https:\/\/www.ubestplc.com\/\"\u003ehttps:\/\/www.ubestplc.com\/\u003c\/a\u003e\u003cbr\u003eContact: \u003ca href=\"mailto:sales@ubestplc.com\"\u003esales@ubestplc.com\u003c\/a\u003e Tel: \u003ca href=\"https:\/\/wa.me\/8618030005825\"\u003e+86 180 3000 5825\u003c\/a\u003e\u003c\/p\u003e","brand":"GE","offers":[{"title":"Default Title","offer_id":51232541638938,"sku":"IS200STCIH2AED","price":155.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/IS200STCIH2AED_2.jpg?v=1761183444","url":"https:\/\/www.ubestplc.com\/az\/products\/ge-contact-input-board-mark-vi-terminal-is200stcih2aed","provider":"Ubest Automation Limited","version":"1.0","type":"link"}