{"product_id":"emerson-eddy-current-sensor-8mm-probes-ez1080-16-11-010","title":"Emerson Eddy Current Sensor | 8mm Probes EZ1080-16-11-010","description":"\u003ch2\u003eEmerson EZ1080 8mm Eddy Current Sensor for Precision Shaft Measurement\u003c\/h2\u003e\n\u003cp\u003eThe Emerson \u003cstrong\u003eEZ1080-16-11-010\u003c\/strong\u003e is an 8mm non-contact eddy current sensor designed for critical rotating machinery. This robust sensor delivers accurate dynamic displacement measurements in demanding applications like turbines, compressors, and gearboxes.\u003c\/p\u003e\n\u003ch3\u003eProduct Overview \u0026amp; Key Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e74b5;\"\u003eBrand\u003c\/span\u003e: Emerson\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e74b5;\"\u003eModel\u003c\/span\u003e: \u003cstrong\u003eEZ1080-16-11-010\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eCategory: 8mm Eddy Current Displacement Sensor\u003c\/li\u003e\n\u003cli\u003eNon-contact measurement for shaft dynamics\u003c\/li\u003e\n\u003cli\u003eExcellent performance in harsh environments\u003c\/li\u003e\n\u003cli\u003eMultiple hazardous area certifications available\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e74b5;\"\u003eLinear Measurement Range\u003c\/span\u003e: 2 mm (80 mils)\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e74b5;\"\u003eInitial Air Gap\u003c\/span\u003e: 0.5 mm (20 mils)\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e74b5;\"\u003eSensitivity (ISF)\u003c\/span\u003e: 7.87 V\/mm or 8 V\/mm (±5%)\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e74b5;\"\u003eNon-Linearity\u003c\/span\u003e: ± 0.025 mm (± 1 mil)\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e74b5;\"\u003eMinimum Target Size\u003c\/span\u003e: 14mm (20mm recommended)\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e74b5;\"\u003eMinimum Shaft Diameter\u003c\/span\u003e: 20mm (25mm recommended)\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e74b5;\"\u003eTarget Material\u003c\/span\u003e: Ferromagnetic steels (AISI 4140, 1035, etc.)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental Ratings \u0026amp; Durability\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e74b5;\"\u003eOperating Temperature\u003c\/span\u003e: -35°C to +180°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e74b5;\"\u003eProtection Class\u003c\/span\u003e: IP67 (IP68 with optional test)\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e74b5;\"\u003ePressure Sealing\u003c\/span\u003e: 10000 hpa (145 psi) up to 120°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e74b5;\"\u003eHazardous Area Certifications\u003c\/span\u003e: ATEX, IECEx, CSA, CCC-Ex\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e74b5;\"\u003eSafety Rating\u003c\/span\u003e: SIL 2 Capable (IEC 61508:2010)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical Dimensions \u0026amp; Construction\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e74b5;\"\u003eCase Thread\u003c\/span\u003e: M10x1\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e74b5;\"\u003eCase Length\u003c\/span\u003e: 160mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e74b5;\"\u003eUnthreaded Length\u003c\/span\u003e: 110mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e74b5;\"\u003eCable Length\u003c\/span\u003e: 1.0 meter\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e74b5;\"\u003eSensor Tip\u003c\/span\u003e: Glass-fiber reinforced PEEK\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e74b5;\"\u003eCase Material\u003c\/span\u003e: Stainless steel\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e74b5;\"\u003eWeight\u003c\/span\u003e: Approximately 100 grams\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEnsure minimum shaft diameter meets 20mm requirement\u003c\/li\u003e\n\u003cli\u003eMaintain specified initial air gap of 0.5mm for optimal performance\u003c\/li\u003e\n\u003cli\u003eUse recommended ferromagnetic steel materials for target surface\u003c\/li\u003e\n\u003cli\u003eThe M10x1 thread and 110mm unthreaded length simplify mounting\u003c\/li\u003e\n\u003cli\u003eVerify target size meets minimum 14mm diameter requirement\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSteam, gas and hydro turbines\u003c\/li\u003e\n\u003cli\u003eCompressors and gearboxes\u003c\/li\u003e\n\u003cli\u003ePumps and fans\u003c\/li\u003e\n\u003cli\u003eRadial and axial shaft displacement measurement\u003c\/li\u003e\n\u003cli\u003eEccentricity and speed\/key monitoring\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePackaging \u0026amp; Shipping Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEach unit includes sensor with 1-meter FEP cable\u003c\/li\u003e\n\u003cli\u003eStandard connector included\u003c\/li\u003e\n\u003cli\u003eGlobal shipping via FedEx, UPS, and DHL\u003c\/li\u003e\n\u003cli\u003eSecure packaging to ensure product integrity\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e74b5;\"\u003eWhat is the difference between API and ISO scale factor?\u003c\/span\u003e The output voltage per unit displacement differs slightly between standards.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e74b5;\"\u003eCan this sensor work in hazardous locations?\u003c\/span\u003e Yes, it carries multiple certifications for intrinsic safety.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e74b5;\"\u003eWhat is the minimum target size?\u003c\/span\u003e The absolute minimum is 14mm, but 20mm is recommended.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e74b5;\"\u003eIs the cable armored?\u003c\/span\u003e The \u003cstrong\u003eEZ1080-16-11-010\u003c\/strong\u003e model features standard non-armored cable.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e74b5;\"\u003eWhat temperature range can the sensor withstand?\u003c\/span\u003e It operates from -35°C to +180°C with 1m cable.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e© 2025 Ubest Automation Limited. All rights reserved.\u003cbr\u003eOriginal Source: \u003ca href=\"https:\/\/www.ubestplc.com\/\"\u003ehttps:\/\/www.ubestplc.com\/\u003c\/a\u003e\u003cbr\u003eContact: \u003ca href=\"mailto:sales@ubestplc.com\"\u003esales@ubestplc.com\u003c\/a\u003e Phone: \u003ca href=\"https:\/\/wa.me\/8618030005825\"\u003e+86 180 3000 5825\u003c\/a\u003e\u003c\/p\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":51235838492954,"sku":"EZ1080-16-11-010","price":149.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/EZ1080-16-11-010_3.jpg?v=1761183472","url":"https:\/\/www.ubestplc.com\/bg\/products\/emerson-eddy-current-sensor-8mm-probes-ez1080-16-11-010","provider":"Ubest Automation Limited","version":"1.0","type":"link"}