{"title":"Chemical","description":"\u003ch3\u003e\u003cstrong\u003eChemical Industry Automation Solutions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eEnhance safety, precision, and efficiency in chemical manufacturing with advanced industrial automation systems. Our portfolio includes PLCs, DCS modules, and intelligent sensors designed for hazardous and process-critical environments. Whether it’s ABB, Honeywell, Siemens, or GE systems, each product ensures reliable control, compliance with chemical standards, and seamless integration across your plant.\u003c\/p\u003e","products":[{"product_id":"hima-f-3334-f3334-4-fold-output-module","title":"HIMA F 3334 \/ F3334 4 Fold Output Module","description":"\u003ch3\u003eKey Features:\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFunction\u003c\/strong\u003e: Safety-related 4-fold output module designed for handling resistive and inductive loads up to 2 A (48 W) and lamp connections up to 25 W.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan _mstmutation=\"1\"\u003e\u003cstrong _mstmutation=\"1\"\u003eSafety Mechanisms\u003c\/strong\u003e:\u003c\/span\u003e\u003cul\u003e\n\u003cli\u003eIntegrated safety shutdown\u003c\/li\u003e\n\u003cli\u003eSafe isolation\u003c\/li\u003e\n\u003cli\u003eLine monitoring\u003c\/li\u003e\n\u003cli\u003eNo output signal upon L- supply break\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan _mstmutation=\"1\"\u003e\u003cstrong _mstmutation=\"1\"\u003eAutomatic Testing\u003c\/strong\u003e: Continuously tested during operation, including:\u003c\/span\u003e\u003cul\u003e\n\u003cli\u003eReading back output signals with an operating point for 0 signal read back at ≤ 6.5 V\u003c\/li\u003e\n\u003cli\u003eSwitching capability and cross-talk detection (walking-bit test)\u003c\/li\u003e\n\u003cli\u003eLine monitoring\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications:\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutputs\u003c\/strong\u003e: 2 A, short circuit proof\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInternal Voltage Drop\u003c\/strong\u003e: Maximum 2 V at 2 A load\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdmissible Line Resistance\u003c\/strong\u003e: Maximum 3.6 Ohm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUndervoltage Tripping\u003c\/strong\u003e: At ≤ 16 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShort Circuit Current\u003c\/strong\u003e: 2.6 to 5 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLine Break Current\u003c\/strong\u003e: 0.5 to 9.5 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Leakage Current\u003c\/strong\u003e: Maximum 550 µA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Voltage if Reset\u003c\/strong\u003e: Maximum 1.5 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Input WD\u003c\/strong\u003e: Maximum 30 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest Signal Duration\u003c\/strong\u003e: Maximum 250 µs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpace Requirement\u003c\/strong\u003e: 4 TE\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan _mstmutation=\"1\"\u003e\u003cstrong _mstmutation=\"1\"\u003eOperating Data\u003c\/strong\u003e:\u003c\/span\u003e\u003cul\u003e\n\u003cli\u003e5 V DC: 130 mA\u003c\/li\u003e\n\u003cli\u003e24 V DC: 130 mA in additional load\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eAdditional Notes:\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLine Break Monitoring\u003c\/strong\u003e: Requires a minimum load of 10 mA. The signal \"line break\" can be used in user programs up to requirement class 3.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannel Operation\u003c\/strong\u003e: Only two channels may operate at the maximum load (2 A) simultaneously. If the load is up to 1 A, all channels can operate simultaneously.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIO Rack Usage\u003c\/strong\u003e: Up to 10 output modules with nominal load can be used in one IO rack.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eParallel Operation\u003c\/strong\u003e: Can be paralleled without the need for external diodes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSoftware Integration\u003c\/strong\u003e: Appertaining software building block HB-BLD-. For current version details, refer to the operating system description.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInrush Current Handling\u003c\/strong\u003e: Potential issues with certain 25 W lamp types due to high inrush current can be mitigated by setting a suppression time (1 to 50 ms) at the building block HB-BLD-. This extends the test duration by the set time if this input is occupied.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003ePlanning Considerations:\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eEnsure line break monitoring with a minimum load of 10 mA.\u003c\/li\u003e\n\u003cli\u003eFor maximum load operation, limit to two channels concurrently; otherwise, all channels can run with loads up to 1 A each.\u003c\/li\u003e\n\u003cli\u003eIn IO racks, restrict to a maximum of 10 output modules with nominal load.\u003c\/li\u003e\n\u003cli\u003eWhen using certain 25 W lamps, set inrush current suppression time to avoid faults.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eThis module provides robust and safe operation for managing various load types, with comprehensive safety features and automatic testing to ensure reliability and efficiency in critical applications.\u003c\/p\u003e","brand":"HIMA","offers":[{"title":"Default Title","offer_id":48939704975642,"sku":"F-3334","price":120.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/F3334_2.jpg?v=1717412193"},{"product_id":"bently-nevada-177230-01-02-05-seismic-transmitter","title":"Bently Nevada | 177230-01-02-05 Seismic Transmitter","description":"\u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eThe Bently Nevada 177230-01-02-05 model Seismic Transmitter is a versatile component designed to integrate seamlessly into your programmable logic controller (PLC) or control system for plant asset condition monitoring. With its simple design, it reduces training, maintenance, and service costs while enhancing the management of downtime and maintenance planning, ultimately helping to prevent catastrophic failures of machinery assets.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFunctionality\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasuring and Transmitting Vibration\u003c\/strong\u003e: This transmitter is utilized for measuring and transmitting mechanical vibration signals, facilitating efficient monitoring of machinery health.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAnalog Signal Conversion\u003c\/strong\u003e: It converts analog vibration signals received from velocity sensors into standard 4-20mA current signal outputs, ensuring compatibility with various control systems and monitoring solutions.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel\u003c\/strong\u003e: 177230-01-02-05\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e: 24 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Signal\u003c\/strong\u003e: 4-20mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e: 0-50 mm\/s (customizable for other ranges as needed)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy\u003c\/strong\u003e: ±1% full scale\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency Response\u003c\/strong\u003e: 2-1000 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: -40°C to 85°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection Rating\u003c\/strong\u003e: IP65\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eSuffix Code\u003c\/strong\u003e:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e177230\u003c\/strong\u003e: 177230 Seismic Transmitter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-01\u003c\/strong\u003e: Measurement Range=0 – 25.4 mm\/s (0 – 1.0 in\/s)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-02\u003c\/strong\u003e: Frequency=3 Hz to 1 kHz (180 to 60 kcpm) peak\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-05\u003c\/strong\u003e: Multiple Approvals (CSA\/NRTL\/C, ATEX\/IECEx)\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiameter\u003c\/strong\u003e: 25.4 mm (1.00 in)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight\u003c\/strong\u003e: 66.0 mm (2.60 in)\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e:\u003c\/p\u003e\u003cul\u003e\u003cli\u003e131 g (4.62 oz), typical\u003c\/li\u003e\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":48985940099354,"sku":"177230-01-02-05","price":1000.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/177230-01-01-CN_2_58c43d5e-8121-441a-bc66-432c60b81686.jpg?v=1732156617"},{"product_id":"990-05-70-03-05-bently-nevada-vibration-transmitter","title":"990-05-70-03-05 | Bently Nevada Vibration Transmitter","description":"\u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eThe Bently Nevada Wire Vibration Transmitter, model 990-05-70-03-05, is an innovative device designed for detecting and monitoring the vibration of cables. Manufactured by Bently Nevada, this transmitter accurately converts detected vibration signals into standard voltage or current outputs, facilitating mechanical equipment condition monitoring and fault diagnosis.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVibration Detection\u003c\/strong\u003e: Specifically engineered to detect the vibration of cables, providing crucial insights into their operational conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Conversion\u003c\/strong\u003e: Converts detected vibration signals into standard voltage or current outputs, ensuring compatibility with various monitoring systems and equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCondition Monitoring and Fault Diagnosis\u003c\/strong\u003e: Used for monitoring the condition of mechanical equipment and diagnosing potential faults, aiding in preventive maintenance and minimizing downtime.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel\u003c\/strong\u003e: 990-05-70-03-05\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Bently Nevada\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e: 24VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Signal\u003c\/strong\u003e: 4-20mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e: 0-50mm\/s\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy\u003c\/strong\u003e: ±3% full scale\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency Response\u003c\/strong\u003e: 10-1000Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e: -40°C to 85°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection Level\u003c\/strong\u003e: IP65\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eSuffix Code\u003c\/strong\u003e:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e990-\u003c\/strong\u003e: 990 Vibration Transmitter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-05\u003c\/strong\u003e: Full-scale= 0-5 mils pp (0-125 μm pp)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-70\u003c\/strong\u003e: System Length=7.0 metres (23.0 feet)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-03\u003c\/strong\u003e: Mounting Option=DIN clips and screws\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-05\u003c\/strong\u003e: Agency Approval Option=CSA Division 2, ATEX Zone 0, ATEX Zone 2 and includes ABS maritime approval\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eDimensions and Weight\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions\u003c\/strong\u003e: 100.1mm (Length) x 73.9mm (Width) x 53.3mm (Height)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight\u003c\/strong\u003e: Approximately 0.43kg\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":48986027000090,"sku":"990-05-70-03-05","price":3000.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/990-08-XX-01-CN3_bb04d6f8-5db0-4e6e-b410-b73a2301dc43.jpg?v=1717070988"},{"product_id":"tk-iah161-honeywell-analog-input-module","title":"TK-IAH161 Honeywell Analog Input Module","description":"\u003cp\u003e\u003cstrong\u003eTK-IAH161 Parameter Specification\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eNumber of Points\u003c\/strong\u003e\u003cbr\u003e16 channels\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eInput Voltage Range (Voltage)\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e±10.25 volts\u003c\/li\u003e\n\u003cli\u003e0 to 10.25 volts\u003c\/li\u003e\n\u003cli\u003e0 to 5.125 volts\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eInput Current Range (Current)\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e0 to 20.5 mA (internal 250 Ω resistor)\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eVoltage Resolution\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e±10.5 volt range: 320 μV\u003c\/li\u003e\n\u003cli\u003e0 to 10.5 volt range: 160 μV\u003c\/li\u003e\n\u003cli\u003e0 to 5 volt range: 80 μV\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eCurrent Resolution\u003c\/strong\u003e\u003cbr\u003e16 bits across each range shown below\u003c\/p\u003e\u003cul\u003e\u003cli\u003e320 nA\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eModule Publish Rate\u003c\/strong\u003e\u003cbr\u003e250 msec\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eInput Impedance\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eVoltage: Greater than 1.0 MΩ\u003c\/li\u003e\n\u003cli\u003eCurrent: 249 Ω nominal\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eOpen Circuit Detection\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003eTypical OC Detection Time: Less than 5 seconds\n\u003cul\u003e\n\u003cli\u003eVoltage:\n\u003cul\u003e\n\u003cli\u003eEven channels: Positive Full scale reading\u003c\/li\u003e\n\u003cli\u003eOdd channels: Negative Full scale reading\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eCurrent:\n\u003cul\u003e\u003cli\u003eNegative Full scale reading\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eNormal Mode Noise Rejection\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003eGreater than 33 dB @ 50 Hz\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eCommon Mode Rejection\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eGreater than 60 dB @ 60 Hz\u003c\/li\u003e\n\u003cli\u003e100 dB @ 50\/60 Hz\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eChannel Bandwidth\u003c\/strong\u003e\u003cbr\u003e20 Hz (-3dB)\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCalibrated Accuracy @ 25°C\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eVoltage: Better than 0.05% of range\u003c\/li\u003e\n\u003cli\u003eCurrent: Better than 0.15% of range including sense resistor\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eRFI Immunity\u003c\/strong\u003e\u003cbr\u003eError of less than 2.0% of range at 10 V\/m, 27 to 1000 MHz\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOvervoltage Capability\u003c\/strong\u003e\u003cbr\u003eContinuous at room temperature (both)\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eVoltage: 30 VDC\u003c\/li\u003e\n\u003cli\u003eCurrent: 8 VDC\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":49003026514202,"sku":"TK-IAH161","price":650.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/TK-IAH161_1.jpg?v=1717155147"},{"product_id":"ge-fanuc-ic200alg264-analog-input-module","title":"GE Fanuc IC200ALG264 Analog Input Module","description":"\u003ch2\u003eIC200ALG264\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eAnalog Input Module, 15 Bit Current 15 Channels\u003c\/strong\u003e\u003c\/p\u003e\u003ch3\u003eModule Specifications\u003c\/h3\u003e\u003ch4\u003eModule Characteristics\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannels:\u003c\/strong\u003e 15 single-ended, one group\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule ID:\u003c\/strong\u003e\u003cul\u003e\n\u003cli\u003eFFFFB50F (when configured for 4-20mA range)\u003c\/li\u003e\n\u003cli\u003eFFFFB40F (when configured for 0-20mA range)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation:\u003c\/strong\u003e\u003cul\u003e\n\u003cli\u003eUser input to logic (optical) and to frame ground: 250VAC continuous; 1500VAC for 1 minute\u003c\/li\u003e\n\u003cli\u003eGroup to group: Not applicable\u003c\/li\u003e\n\u003cli\u003eChannel to channel: None\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLED Indicators:\u003c\/strong\u003e OK LED. See \"LED Indicators\" for description.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane Current Consumption:\u003c\/strong\u003e 5V output: 100mA maximum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExternal Power Supply:\u003c\/strong\u003e None\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal Derating:\u003c\/strong\u003e None\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfiguration Parameters:\u003c\/strong\u003e Range select (jumpers on carrier)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiagnostics:\u003c\/strong\u003e Loss of Internal Power, Open wire detection of 4-20mA signals only\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eInput Characteristics\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Current:\u003c\/strong\u003e\u003cul\u003e\n\u003cli\u003e4 to 20mA (default: no terminal jumper installed)\u003c\/li\u003e\n\u003cli\u003e0 to 20mA (with terminal jumper installed)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Impedance:\u003c\/strong\u003e 100 Ohms\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy at:\u003c\/strong\u003e\u003cul\u003e\n\u003cli\u003e25 degrees C*: +\/-0.3% typical of full scale, +\/-0.5% maximum of full scale\u003c\/li\u003e\n\u003cli\u003e0 to 60 degrees C: +\/-1% maximum of full scale\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResolution:\u003c\/strong\u003e 15 bits\n\u003cul\u003e\n\u003cli\u003e0.5µA = 1 count (for 4-20mA range)\u003c\/li\u003e\n\u003cli\u003e0.625µA = 1 count (for 0-20mA range)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFilter Response (3dB Corner Frequency):\u003c\/strong\u003e 24 Hz +\/-20%\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUpdate Rate per Module:\u003c\/strong\u003e 7.5ms\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eCompatibility\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVersaPro Software:\u003c\/strong\u003e Version 2.0 or higher\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVersaMax PLC CPU Firmware:\u003c\/strong\u003e Version 2.10 or higher\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVersaMax Ethernet NIU Firmware:\u003c\/strong\u003e Version 1.10 or higher\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVersaMax DeviceNet, Profibus, or Genius NIU Firmware:\u003c\/strong\u003e Planned for future release\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cem\u003eIn the presence of severe RF interference (IEC 1000-4-3, 10V\/m), accuracy may be degraded to +\/-2%\u003c\/em\u003e\u003c\/p\u003e","brand":"GE","offers":[{"title":"Default Title","offer_id":49021023256858,"sku":"IC200ALG264","price":600.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/IC200MDL740-5_3ecd5498-42c8-412d-be5b-3696f0f9ebde.jpg?v=1717306390"},{"product_id":"ge-fanuc-ic200mdl740-versamax-output-module","title":"GE Fanuc IC200MDL740 VersaMax Output Module","description":"\u003cp\u003eVersaMax 12\/24VDC 0.5Amp Positive Logic Output Module\u003c\/p\u003e\u003ch2\u003eModule Characteristics\u003c\/h2\u003e\u003ch3\u003ePoints\u003c\/h3\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eIC200MDL740, BXIOOD1624:\u003c\/strong\u003e 1 group of 16 outputs\u003c\/li\u003e\u003c\/ul\u003e\u003ch3\u003eModule ID\u003c\/h3\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eIC200MDL740, BXIOOD1624:\u003c\/strong\u003e FFFF8080\u003c\/li\u003e\u003c\/ul\u003e\u003ch3\u003eIsolation\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eUser Input to Logic (Optical) and Frame Ground:\u003c\/strong\u003e 250VAC continuous; 1500VAC for 1 minute\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIC200MDL740, BXIOOD1624 Group to Group:\u003c\/strong\u003e Not applicable\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePoint to Point:\u003c\/strong\u003e None\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eLED Indicators\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndividual Point On\/Off State:\u003c\/strong\u003e One LED per point\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField Power Present:\u003c\/strong\u003e FLD PWR LED\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane Power Present:\u003c\/strong\u003e OK LED\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eBackplane Current Consumption\u003c\/h3\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eIC200MDL740, BXIOOD1624:\u003c\/strong\u003e 5V output: 45mA maximum\u003c\/li\u003e\u003c\/ul\u003e\u003ch3\u003eExternal Power Supply\u003c\/h3\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eVoltage:\u003c\/strong\u003e +10.2 to +30VDC, +12\/24VDC nominal\u003c\/li\u003e\u003c\/ul\u003e\u003ch3\u003eThermal Derating\u003c\/h3\u003e\u003cul\u003e\u003cli\u003e\u003cstrong\u003eSee diagrams\u003c\/strong\u003e\u003c\/li\u003e\u003c\/ul\u003e\u003ch3\u003eOutput Characteristics\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Voltage:\u003c\/strong\u003e +10.2 to +30VDC, +12\/24VDC nominal\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Voltage Drop:\u003c\/strong\u003e 0.3V maximum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoad Current:\u003c\/strong\u003e 0.5A at 30VDC maximum (resistive); 2.0A maximum for 100ms inrush\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Leakage Current:\u003c\/strong\u003e 0.5mA at 30VDC maximum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOn Response Time:\u003c\/strong\u003e 0.2ms, maximum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOff Response Time:\u003c\/strong\u003e 1.0ms, maximum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection:\u003c\/strong\u003e No internal fuses\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE","offers":[{"title":"Default Title","offer_id":49021147480346,"sku":"IC200MDL740","price":850.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/IC200MDL740-7.jpg?v=1717305993"},{"product_id":"ic200alg620-ge-fanuc-versamax-analog-input-module","title":"IC200ALG620 GE Fanuc VersaMax Analog Input Module","description":"\u003ch2\u003eProduct Description\u003c\/h2\u003e\u003cp\u003eThe \u003cstrong\u003eIC200ALG620 Analog Input RTD Module\u003c\/strong\u003e is an intelligent module that accepts input signals from up to four RTD input devices and provides input data with 16 bits of resolution.\u003c\/p\u003e\u003ch3\u003eHost Interface\u003c\/h3\u003e\u003cp\u003eThe RTD Module provides four words of analog input data.\u003c\/p\u003e\u003ch3\u003eDiagnostics\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eOver\/under range\u003c\/li\u003e\n\u003cli\u003eOpen wire\u003c\/li\u003e\n\u003cli\u003eInput short\u003c\/li\u003e\n\u003cli\u003eNon-volatile memory storage fault\u003c\/li\u003e\n\u003cli\u003eWiring fault\u003c\/li\u003e\n\u003cli\u003eHigh\/low alarm\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eLED Indicator\u003c\/h3\u003e\u003cp\u003eThe \u003cstrong\u003eOK LED\u003c\/strong\u003e indicates module status:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOn green\u003c\/strong\u003e indicates normal operation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlashing green\u003c\/strong\u003e indicates boot mode or update\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlashing amber\u003c\/strong\u003e indicates self-diagnostic error\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOff\u003c\/strong\u003e indicates no 3.3V backplane power\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eModule Characteristics\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannels:\u003c\/strong\u003e Four 3-wire and\/or 4-wire RTDs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule ID:\u003c\/strong\u003e FFFF9803\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation:\u003c\/strong\u003e\u003cul\u003e\n\u003cli\u003eUser input to logic (optical) and to frame ground: 250VAC continuous; 1500VAC for 1 minute\u003c\/li\u003e\n\u003cli\u003eGroup to group: Not applicable\u003c\/li\u003e\n\u003cli\u003eChannel to channel: 50VDC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLED Indicators:\u003c\/strong\u003e\u003cul\u003e\u003cli\u003eOK LED: Green indicates backplane power is present. Amber indicates a module fault.\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane Current Consumption:\u003c\/strong\u003e 5V output: 125mA maximum, 3.3V output: 125mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExternal Power Supply:\u003c\/strong\u003e None\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal Derating:\u003c\/strong\u003e None\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfiguration Parameters:\u003c\/strong\u003e See configuration table\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiagnostics:\u003c\/strong\u003e Open RTD, input short, under-range, over-range, non-volatile memory storage fault, wiring fault, and high\/low alarm\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eUpdate Rate\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e60 Hz:\u003c\/strong\u003e Approximately 210 ms per channel\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e50 Hz:\u003c\/strong\u003e Approximately 230 ms per channel\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eNormal Mode Rejection\u003c\/h3\u003e\u003cp\u003e60dB, at 50\/60 Hz, 100% span\u003c\/p\u003e\u003ch3\u003eCommon Mode Rejection\u003c\/h3\u003e\u003cp\u003e120 dB at 50\/60Hz, 100 ohm imbalance\u003c\/p\u003e\u003ch3\u003eCommon Mode Voltage\u003c\/h3\u003e\u003cp\u003e3V maximum\u003c\/p\u003e\u003ch3\u003eNormal Mode Voltage\u003c\/h3\u003e\u003cp\u003e5V maximum\u003c\/p\u003e\u003ch3\u003eDigital Resolution\u003c\/h3\u003e\u003cp\u003e15 bits plus sign\u003c\/p\u003e\u003ch3\u003eOperating Temperature Range\u003c\/h3\u003e\u003cp\u003e0 to 60 Degrees C ambient\u003c\/p\u003e\u003ch3\u003eInput Characteristics\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRTD Types:\u003c\/strong\u003e\u003cul\u003e\n\u003cli\u003e25, 100, and 1000 ohm platinum\u003c\/li\u003e\n\u003cli\u003e10, 50, and 100 ohm copper\u003c\/li\u003e\n\u003cli\u003e100 and 120 ohm nickel\u003c\/li\u003e\n\u003cli\u003e604 ohms nickel\/iron\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResistance Ranges:\u003c\/strong\u003e\u003cul\u003e\n\u003cli\u003e0 to 500 ohms\u003c\/li\u003e\n\u003cli\u003e0 to 3000 ohms\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy, at 25° C:\u003c\/strong\u003e\u003cul\u003e\n\u003cli\u003e+\/–0.15% on resistance measurement\u003c\/li\u003e\n\u003cli\u003e+\/-0.15% on RTD (temperature) measurement\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature Sensitivity (0° to 60°C):\u003c\/strong\u003e\u003cul\u003e\n\u003cli\u003e+\/–0.004% of reading\u003c\/li\u003e\n\u003cli\u003e+\/–1.5µV per °C referred to input\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Lead Resistance:\u003c\/strong\u003e 50 ohms per lead\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE","offers":[{"title":"Default Title","offer_id":49021393666330,"sku":"IC200ALG620","price":800.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/IC200ALG630_2.jpg?v=1717160965"},{"product_id":"ic695alg608-ge-fanuc-rx3i-analog-input-module","title":"IC695ALG608 | GE Fanuc | RX3i Analog Input Module","description":"\u003ch2\u003eNon-Isolated Differential Analog Voltage\/Current Input Module IC695ALG608\u003c\/h2\u003e\u003cp\u003eThe \u003cstrong\u003eIC695ALG608\u003c\/strong\u003e module provides 8 single-ended or 4 differential input channels. These analog input modules can be configured for various ranges including current (0 to 20mA, 4 to 20mA, +\/- 20mA) and voltage (+\/- 10V, 0 to 10V, +\/- 5V, 0 to 5V, 1 to 5V). They are compatible with Box-style, Extended Box-style, Spring-style, or Extended Spring-style terminal blocks, with extended terminal blocks accommodating shielded wiring.\u003c\/p\u003e\u003ch3\u003eModule Features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eCompletely software-configurable, no module jumpers to set\u003c\/li\u003e\n\u003cli\u003eFull autocalibration\u003c\/li\u003e\n\u003cli\u003eOn-board error-checking\u003c\/li\u003e\n\u003cli\u003eOpen-circuit detection for all voltage and 4-20mA inputs\u003c\/li\u003e\n\u003cli\u003eConfigurable scaling and offsets per channel\u003c\/li\u003e\n\u003cli\u003eHigh\/low alarm detection and reporting selectable per channel\u003c\/li\u003e\n\u003cli\u003eModule fault reporting\u003c\/li\u003e\n\u003cli\u003eSupports diagnostic point fault contacts in the logic program\u003c\/li\u003e\n\u003cli\u003eFlash memory for future upgrades\u003c\/li\u003e\n\u003cli\u003ePositive and negative Rate of Change Alarms\u003c\/li\u003e\n\u003cli\u003eAutocalibration at startup\u003c\/li\u003e\n\u003cli\u003eConfigurable interrupts for channel alarms and faults\u003c\/li\u003e\n\u003cli\u003eTerminal Block insertion or removal detection\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications: IC695ALG608\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Ranges:\u003c\/strong\u003e\u003cul\u003e\n\u003cli\u003eCurrent: 0 to 20mA, 4 to 20mA, +\/- 20mA\u003c\/li\u003e\n\u003cli\u003eVoltage: +\/- 10V, 0 to 10V, +\/- 5V, 0 to 5V, 1 to 5V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane Power Requirements:\u003c\/strong\u003e\u003cul\u003e\n\u003cli\u003eALG608: 330 mA maximum @ 5.0V, 600 mA maximum @ 3.3V\u003c\/li\u003e\n\u003cli\u003eALG616: 450 mA maximum @ 5.0V, 600 mA maximum @ 3.3V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCPU Version:\u003c\/strong\u003e RX3i CPU firmware version 3.0 and later\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProgrammer Version:\u003c\/strong\u003e Machine Edition version 5.0 SP3 and later\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Dissipation within Module:\u003c\/strong\u003e\u003cul\u003e\n\u003cli\u003eIC695ALG608: 4.83 watts maximum\u003c\/li\u003e\n\u003cli\u003eIC695ALG616: 6.48 watts maximum\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal Derating:\u003c\/strong\u003e None\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResolution:\u003c\/strong\u003e 24 bit ADC converted to Floating Point or Integer\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Data Format:\u003c\/strong\u003e Configurable as floating point IEEE 32 bit or 16-bit integer in a 32-bit field\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFilter Options:\u003c\/strong\u003e 8Hz, 12Hz, 16Hz, 40Hz, 200Hz, 500Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Scan Time:\u003c\/strong\u003e Depends on the number of acquisition cycles in the scan and the configured filter option\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Impedance:\u003c\/strong\u003e \u0026gt;100 Kohm voltage inputs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Input Resistance:\u003c\/strong\u003e 249 ohms +\/- 1%\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOpen Circuit Detection Time:\u003c\/strong\u003e 1 second maximum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOvervoltage:\u003c\/strong\u003e +\/-60 VDC continuous, maximum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOvercurrent:\u003c\/strong\u003e +\/-28mA continuous, maximum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNormal Mode Noise Rejection:\u003c\/strong\u003e 500 Hz: 0.0 dB\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommon Mode Noise Rejection:\u003c\/strong\u003e 120dB minimum @ 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannel-Channel DC Crosstalk:\u003c\/strong\u003e\u003cul\u003e\n\u003cli\u003eSingle ended mode: -80 dB minimum\u003c\/li\u003e\n\u003cli\u003eDifferential mode, grounded common: -80 dB minimum\u003c\/li\u003e\n\u003cli\u003eDifferential mode, floating common: -60 dB minimum\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCalibrated Accuracy:\u003c\/strong\u003e\u003cul\u003e\n\u003cli\u003e@ 13°C – 33°C with 8 Hz, 12 Hz, and 16 Hz filter: varies depending on range\u003c\/li\u003e\n\u003cli\u003e@ 0°C – 60°C with 8 Hz, 12 Hz, and 16 Hz filter: varies depending on range\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCalibration Interval:\u003c\/strong\u003e 12 months typical\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation Voltage terminal block to backplane\/chassis:\u003c\/strong\u003e Opto-isolated, transformer isolated 250 VAC continuous\/1500 VAC for 1 minute\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE","offers":[{"title":"Default Title","offer_id":49021928243482,"sku":"IC695ALG608","price":700.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/IC695ALG608_4.jpg?v=1717163466"},{"product_id":"ge-fanuc-ic694mdl754-rx3i-output-module","title":"GE Fanuc IC694MDL754 RX3i Output Module","description":"\u003ch3\u003eIC694MDL754\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eOutput Module, 12\/24VDC, 0.75A, 32-Point Grouped, with ESCP\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eThe \u003cstrong\u003eIC694MDL754\u003c\/strong\u003e is a 12\/24 volt DC, ESCP 0.75A Positive Logic Output module, providing 32 discrete outputs in two isolated groups of 16. Each group has its own common. The outputs are positive logic or sourcing-type outputs, switching loads on the positive side of the power supply and supplying current to the load. Each point features electronic overcurrent\/short circuit protection and generates an individual fault if either condition exists. In addition to output driver faults sent back to the RX3i controller, the module provides various fault indications including loss of field side power fault, ESCP point failure within a group, field terminal block ON\/OFF status, and DIP switch configuration mismatch fault.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eModule Features:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation:\u003c\/strong\u003e\u003cul\u003e\n\u003cli\u003eField to Backplane (optical) and to Frame Ground: 250 VAC continuous; 1500 VAC for 1 minute\u003c\/li\u003e\n\u003cli\u003eGroup to Group: 250 VAC continuous; 1500 VAC for 1 minute\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule ID:\u003c\/strong\u003e 0x059h\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Current:\u003c\/strong\u003e 0.75 Amps per point\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Consumption:\u003c\/strong\u003e 300 mA (maximum) from 5 volt bus on backplane\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal Derating:\u003c\/strong\u003e No derating at 24VDC. At 30VDC, outputs are derated above 42 degrees C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExternal Power Supply:\u003c\/strong\u003e +12 VDC to +30 VDC, 12\/24 VDC nominal\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Characteristics:\u003c\/strong\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInrush Current:\u003c\/strong\u003e 3 Amps supplied for 10ms without ESCP trip\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Voltage Drop:\u003c\/strong\u003e 0.3 volt DC maximum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSteady-state Overcurrent Trip:\u003c\/strong\u003e 5 Amps typical per point\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Leakage Current:\u003c\/strong\u003e 0.1mA maximum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOn Response Time:\u003c\/strong\u003e 0.5ms maximum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOff Response Time:\u003c\/strong\u003e 0.5ms maximum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection:\u003c\/strong\u003e Short-circuit protection, overcurrent protection, overtemperature protection, all with auto recovery.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE","offers":[{"title":"Default Title","offer_id":49022013833498,"sku":"IC694MDL754","price":700.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/IC694MDL754_10.jpg?v=1717303820"},{"product_id":"177230-02-01-05-bently-nevada-seismic-transmitter","title":"177230-02-01-05 | Bently Nevada |  Seismic Transmitter","description":"\u003cp\u003e\u003cstrong\u003eProduct Information for Bently Nevada 177230-02-01-05 Seismic Transmitter\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e The Bently Nevada 177230-02-01-05 is a robust seismic transmitter designed to measure vibration in various industrial applications. It features a wide frequency response range and high shock survivability, making it suitable for demanding environments.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eModel and Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel\u003c\/strong\u003e: 177230-02-01-05\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Bently Nevada\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency Response Range\u003c\/strong\u003e: 2.5 Hz to 10 kHz (150 CPM to 600 KCMP) with a tolerance of ±10%.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLinearity Tolerance\u003c\/strong\u003e: ±1%.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Bias\u003c\/strong\u003e: Referenced to Pin B with a voltage of 2.5 V ± 0.1 V.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFull Scale Range\u003c\/strong\u003e:\n\u003cul\u003e\n\u003cli\u003eAcceleration: 147 m\/s² (15 g's) peak.\u003c\/li\u003e\n\u003cli\u003eVelocity Range Option AA: 0 – 12.7 mm\/s (0 – 0.5 in\/s), 0 – 25.4 mm\/s (0 – 1.0 in\/s), 0 – 50.8 mm\/s (0 – 2.0 in\/s).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounted Resonant Frequency\u003c\/strong\u003e: Greater than 12 kHz.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransverse Sensitivity\u003c\/strong\u003e: Less than 5% of sensitivity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensing Element Type\u003c\/strong\u003e: Ceramic \/ Shear.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eEnvironmental Limits\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e: -40°C to +85°C (-40°F to +185°F).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical Isolation\u003c\/strong\u003e: Greater than 10^8 ohms.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation Breakdown Voltage\u003c\/strong\u003e: 600 Vrms with less than 1 mA leakage current.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShock Survivability\u003c\/strong\u003e: Maximum drop test of 9.810 m\/s² (1,000 g peak).\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eSuffix Options\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e177230\u003c\/strong\u003e: Base model.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-02\u003c\/strong\u003e: Measurement Range is 0 – 50.8 mm\/s (0 – 2.0 in\/s).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-01\u003c\/strong\u003e: Frequency range is 10 Hz to 1 kHz (600 to 60 KCMP) RMS.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-05\u003c\/strong\u003e: Multiple approvals including CSA\/NRTL\/C, ATEX\/IECEx.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eDimensions and Weight\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiameter\u003c\/strong\u003e: 25.4 mm (1.00 in).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight\u003c\/strong\u003e: 66.0 mm (2.60 in).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight\u003c\/strong\u003e: 131 g (4.62 oz), typical.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eThis seismic transmitter is engineered to provide reliable and accurate vibration measurements, ensuring optimal performance in a wide range of industrial applications. Its durable construction and compliance with multiple safety standards make it a versatile and dependable choice.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":49039519547674,"sku":"177230-02-01-05","price":58.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/330500-02-00_3_4c1c0286-71f1-44c3-a6c7-6ff6ef206b25.jpg?v=1716981913"},{"product_id":"new-bently-nevada-seismic-transmitter-177230-02","title":"New Bently Nevada  Seismic Transmitter 177230-02","description":"\u003cp\u003e\u003cstrong\u003eProduct Information for Bently Nevada 177230-02 Seismic Transmitter\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e The Bently Nevada 177230-02 is a highly reliable seismic transmitter designed to measure and monitor vibration in a variety of industrial applications. It offers a broad frequency response range and robust environmental resistance, ensuring accurate and dependable performance in demanding conditions.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eModel and Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel\u003c\/strong\u003e: 177230-02\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Bently Nevada\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency Response Range\u003c\/strong\u003e: 2.5 Hz to 10 kHz (150 CPM to 600 KCPM) with a tolerance of ±10%.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLinearity Tolerance\u003c\/strong\u003e: ±1%.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Bias\u003c\/strong\u003e: Referenced to Pin B with a voltage of 2.5 V ± 0.1 V.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFull Scale Range\u003c\/strong\u003e:\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAcceleration\u003c\/strong\u003e: 147 m\/s² (15 g's) peak.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVelocity Range (Option AA)\u003c\/strong\u003e:\n\u003cul\u003e\n\u003cli\u003e0 – 12.7 mm\/s (0 – 0.5 in\/s)\u003c\/li\u003e\n\u003cli\u003e0 – 25.4 mm\/s (0 – 1.0 in\/s)\u003c\/li\u003e\n\u003cli\u003e0 – 50.8 mm\/s (0 – 2.0 in\/s)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounted Resonant Frequency\u003c\/strong\u003e: Greater than 12 kHz.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransverse Sensitivity\u003c\/strong\u003e: Less than 5% of sensitivity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensing Element Type\u003c\/strong\u003e: Ceramic \/ Shear.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eEnvironmental Limits\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e: -40°C to +85°C (-40°F to +185°F).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical Isolation\u003c\/strong\u003e: Greater than 10^8 ohms.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation Breakdown Voltage\u003c\/strong\u003e: 600 Vrms with less than 1 mA leakage current.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShock Survivability\u003c\/strong\u003e: Maximum drop test of 9.810 m\/s² (1,000 g peak).\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eSuffix Option\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e177230\u003c\/strong\u003e: Base model\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-02\u003c\/strong\u003e: Measurement Range is 0 – 50.8 mm\/s (0 – 2.0 in\/s).\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eDimensions and Weight\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiameter\u003c\/strong\u003e: 25.4 mm (1.00 in).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight\u003c\/strong\u003e: 66.0 mm (2.60 in).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight\u003c\/strong\u003e: 131 g (4.62 oz), typical.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eThis seismic transmitter is built for high performance and reliability, ensuring precise vibration monitoring in various industrial settings. Its robust construction and comprehensive specifications make it a versatile tool for maintaining operational efficiency and safety.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":49039540748570,"sku":"177230-02","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/177230-01-01-05_397fa192-927b-4133-9548-d1237a87b4bf.jpg?v=1716982478"},{"product_id":"177230-01-01-05-seismic-transmitter-bently-nevada","title":"177230-01-01-05 Seismic Transmitter Bently Nevada","description":"\u003cp\u003e\u003cstrong\u003eProduct Information for Bently Nevada 177230-01-01-05 Seismic Transmitter\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e The Bently Nevada 177230-01-01-05 is a high-precision seismic transmitter designed for accurate vibration measurement across a wide frequency range. Its robust design and extensive approvals make it ideal for industrial environments where reliable monitoring is essential.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eModel and Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel\u003c\/strong\u003e: 177230-01-01-05\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Bently Nevada\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency Response Range\u003c\/strong\u003e: 2.5 Hz to 10 kHz (150 CPM to 600 KCPM) with a tolerance of ±10%.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLinearity Tolerance\u003c\/strong\u003e: ±1%.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Bias\u003c\/strong\u003e: Referenced to Pin B with a voltage of 2.5 V ± 0.1 V.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFull Scale Range\u003c\/strong\u003e:\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAcceleration\u003c\/strong\u003e: 147 m\/s² (15 g's) peak.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVelocity Range (Option AA)\u003c\/strong\u003e:\n\u003cul\u003e\n\u003cli\u003e0 – 12.7 mm\/s (0 – 0.5 in\/s)\u003c\/li\u003e\n\u003cli\u003e0 – 25.4 mm\/s (0 – 1.0 in\/s)\u003c\/li\u003e\n\u003cli\u003e0 – 50.8 mm\/s (0 – 2.0 in\/s)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounted Resonant Frequency\u003c\/strong\u003e: Greater than 12 kHz.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransverse Sensitivity\u003c\/strong\u003e: Less than 5% of sensitivity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensing Element Type\u003c\/strong\u003e: Ceramic \/ Shear.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eEnvironmental Limits\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e: -40°C to +85°C (-40°F to +185°F).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical Isolation\u003c\/strong\u003e: Greater than 10^8 ohms.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation Breakdown Voltage\u003c\/strong\u003e: 600 Vrms with less than 1 mA leakage current.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShock Survivability\u003c\/strong\u003e: Maximum drop test of 9.810 m\/s² (1,000 g peak).\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eSuffix Options\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e177230\u003c\/strong\u003e: Base model\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-01\u003c\/strong\u003e: Measurement Range is 0 – 25.4 mm\/s (0 – 1.0 in\/s).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-01\u003c\/strong\u003e: Frequency range is 10 Hz to 1 kHz (600 to 60 KCMP) RMS.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-05\u003c\/strong\u003e: Multiple approvals including CSA\/NRTL\/C, ATEX\/IECEx.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eDimensions and Weight\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiameter\u003c\/strong\u003e: 25.4 mm (1.00 in).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight\u003c\/strong\u003e: 66.0 mm (2.60 in).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight\u003c\/strong\u003e: 131 g (4.62 oz), typical.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eThis seismic transmitter is built to deliver precise and reliable vibration measurements in industrial settings. Its extensive frequency response and robust design make it a dependable choice for monitoring and maintaining machinery health and safety.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":49039559065882,"sku":"177230-01-01-05","price":68.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/177230-01-01-05_1_e1b04425-184e-4837-86d0-f279e2d62866.jpg?v=1716982314"},{"product_id":"177230-01-01-cn-seismic-transmitter-bently-nevada","title":"177230-01-01-CN Seismic Transmitter Bently Nevada","description":"\u003cp\u003e\u003cstrong\u003eProduct Information for Bently Nevada 177230-01-01-CN Seismic Transmitter\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e The Bently Nevada 177230-01-01-CN is a highly precise seismic transmitter designed to deliver accurate vibration measurements. It is suitable for various industrial applications, featuring a broad frequency response range and robust environmental limits.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eModel and Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel\u003c\/strong\u003e: 177230-01-01-CN\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Bently Nevada\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency Response Range\u003c\/strong\u003e: 2.5 Hz to 10 kHz (150 CPM to 600 KCPM) with a tolerance of ±10%.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLinearity Tolerance\u003c\/strong\u003e: ±1%.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Bias\u003c\/strong\u003e: Referenced to Pin B with a voltage of 2.5 V ± 0.1 V.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFull Scale Range\u003c\/strong\u003e:\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAcceleration\u003c\/strong\u003e: 147 m\/s² (15 g's) peak.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVelocity Range (Option AA)\u003c\/strong\u003e:\n\u003cul\u003e\n\u003cli\u003e0 – 12.7 mm\/s (0 – 0.5 in\/s)\u003c\/li\u003e\n\u003cli\u003e0 – 25.4 mm\/s (0 – 1.0 in\/s)\u003c\/li\u003e\n\u003cli\u003e0 – 50.8 mm\/s (0 – 2.0 in\/s)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounted Resonant Frequency\u003c\/strong\u003e: Greater than 12 kHz.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransverse Sensitivity\u003c\/strong\u003e: Less than 5% of sensitivity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensing Element Type\u003c\/strong\u003e: Ceramic \/ Shear.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eEnvironmental Limits\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e: -40°C to +85°C (-40°F to +185°F).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical Isolation\u003c\/strong\u003e: Greater than 10^8 ohms.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation Breakdown Voltage\u003c\/strong\u003e: 600 Vrms with less than 1 mA leakage current.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShock Survivability\u003c\/strong\u003e: Maximum drop test of 9.810 m\/s² (1,000 g peak).\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eSuffix Options\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e177230\u003c\/strong\u003e: Base model\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-01\u003c\/strong\u003e: Measurement Range is 0 – 25.4 mm\/s (0 – 1.0 in\/s).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-01\u003c\/strong\u003e: Frequency range is 10 Hz to 1 kHz (600 to 60 KCMP) RMS.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-CN\u003c\/strong\u003e: Country-specific approvals.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eDimensions and Weight\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiameter\u003c\/strong\u003e: 25.4 mm (1.00 in).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight\u003c\/strong\u003e: 66.0 mm (2.60 in).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight\u003c\/strong\u003e: 131 g (4.62 oz), typical.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eThis seismic transmitter is designed to provide precise and reliable vibration monitoring, making it an essential tool for industrial applications. Its wide frequency response, high shock survivability, and specific country approvals ensure its suitability and compliance in various regions.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":49039593537818,"sku":"177230-01-01-CN","price":78.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/177230-01-01-CN_2_064d2b86-afc6-485b-be83-ce140024688c.jpg?v=1716982689"},{"product_id":"990-08-xx-01-cn-bently-nevada-two-wire-vibration-transmitter","title":"990-08-XX-01-CN Bently Nevada Two-wire Vibration Transmitter","description":"\u003cp\u003e\u003cstrong\u003eProduct Information for Bently Nevada 990-08-XX-01-CN Wire Vibration Transmitter\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e The Bently Nevada 990-08-XX-01-CN Wire Vibration Transmitter is an essential component for detecting vibration in cables and converting these signals into standard voltage\/current output. It is specifically designed for mechanical equipment condition monitoring and fault diagnosis, providing crucial insights into machinery health.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eModel and Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel\u003c\/strong\u003e: 990-08-XX-01-CN\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer\u003c\/strong\u003e: Bently Nevada\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eSuffix Code\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e990-\u003c\/strong\u003e: 990 Vibration Transmitter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-01\u003c\/strong\u003e: Mounting Option with DIN clips and screws\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-CN\u003c\/strong\u003e: Country-specific approvals\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVibration Detection\u003c\/strong\u003e: Detects vibration in cables, enabling proactive maintenance measures.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Conversion\u003c\/strong\u003e: Converts detected vibration signals into standard voltage\/current output for easy interpretation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCondition Monitoring\u003c\/strong\u003e: Used for monitoring mechanical equipment condition and diagnosing faults.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e: 24VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Signal\u003c\/strong\u003e: 4-20mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e: 0-50mm\/s\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy\u003c\/strong\u003e: ±3% full scale\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency Response\u003c\/strong\u003e: 10-1000Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransmitter Temperature\u003c\/strong\u003e:\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: -35°C to +85°C (-31°F to +185°F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e: -52°C to +100°C (-62°F to +212°F)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProbe Temperature\u003c\/strong\u003e:\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: -52°C to +177°C (-62°F to +351°F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e: -52°C to +177°C (-62°F to +351°F)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e: 100% condensing, non-submerged, with protection of coaxial connectors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection Level\u003c\/strong\u003e: IP65\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions\u003c\/strong\u003e: 100.1mm (Length) x 73.9mm (Width) x 53.3mm (Height)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight\u003c\/strong\u003e: Approximately 0.43kg\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eThe Bently Nevada 990-08-XX-01-CN Wire Vibration Transmitter offers reliable performance and precise measurements in harsh industrial environments. With its compact design and robust construction, it provides essential data for maintaining machinery health and preventing unexpected downtime.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":49040144466202,"sku":"990-08-XX-01-CN","price":1800.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/990-08-XX-01-CN2.jpg?v=1716987601"},{"product_id":"bently-nevada-990-vibration-transmitter-990-05-50-02-00","title":"Bently Nevada | 990 Vibration Transmitter | 990-05-50-02-00","description":"\u003cp\u003e\u003cstrong\u003eOrdering Information for 990-05-50-02-00\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOverview:\u003c\/strong\u003e The 990 Vibration Transmitter is a two-wire, loop-powered device designed to provide a simple 4 to 20 mA proportional vibration signal as input. This specific configuration, denoted by the code 990-05-50-02-00, is tailored to meet particular vibration monitoring requirements.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVibration Range:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\u003cli\u003eFull-scale range of 0-5 mils pp (0-125 μm pp), ensuring precise vibration detection.\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSystem Length:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\u003cli\u003eSystem length of 5.0 meters (16.4 feet), offering flexibility in installation.\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting Option:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\u003cli\u003eBulkhead screws provided as the mounting option, ensuring secure installation.\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAgency Approval:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\u003cli\u003eNo agency approval required, simplifying procurement processes.\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eElectrical Specification:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\u003cli\u003eAccepts 1 non-contacting 3300 NSv Proximity Probe and extension cable.\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\u003cli\u003eRequires +12 to +35 Vdc input at the transmitter terminal.\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e4 to 20 mA Signal Output:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\u003cli\u003eProvides a 4 to 20 mAdc signal over the specified full-scale range in a 2-wire configuration.\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLoop Accuracy:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\u003cli\u003eWithin ±1.5% over the specified full-scale range. Accuracy is rated from the TEST signal input to the voltage measured across a 250 Ω loop resistance. The ±1.5% error is in addition to the Prox Out Incremental Scale Factor.\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProbe Gap:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\u003cli\u003eProbe must be gapped between 0.5 and 1.75 mm (20 and 55 mils) from the target to ensure full-scale range.\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum Loop Resistance:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\u003cli\u003e1,000 Ω including cable at 35 Vdc.\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCurrent Limiting:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\u003cli\u003e23 mA typical.\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e0.43 kg (approximately)\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003eThis configuration of the 990 Vibration Transmitter offers precise vibration monitoring capabilities, making it suitable for various industrial applications. Its straightforward installation, accurate measurements, and reliable performance ensure effective integration into monitoring systems.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":49040186638618,"sku":"990-05-50-02-00","price":2600.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/990-08-XX-01-CN2_bc452872-e142-4b1e-a411-ce5c07c699fb.jpg?v=1716987898"},{"product_id":"990-10-xx-01-00-bently-nevada-vibration-transmitter","title":"990-10-XX-01-00 Bently Nevada Vibration Transmitter","description":"\u003cp\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eThe Bently Nevada Model 990-10-XX-01-00 Wire Vibration Transmitter is a high-performance device designed for mechanical equipment condition monitoring and fault diagnosis. This transmitter detects the vibration of cables and converts the detected vibration signals into standard voltage\/current outputs, making it an essential tool for maintaining the health and efficiency of mechanical systems.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVibration Detection\u003c\/strong\u003e: Accurately detects vibration in cables, providing crucial data for condition monitoring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Conversion\u003c\/strong\u003e: Converts vibration signals into a standard 4-20mA output, compatible with various monitoring systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCondition Monitoring\u003c\/strong\u003e: Ideal for mechanical equipment condition monitoring and fault diagnosis, ensuring timely maintenance and preventing unexpected breakdowns.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Option\u003c\/strong\u003e: Equipped with 35 mm DIN rail clips for easy installation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry-Specific Approvals\u003c\/strong\u003e: Meets specific regulatory standards based on the country of use.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e: 24VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Signal\u003c\/strong\u003e: 4-20mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e: 0-50mm\/s\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy\u003c\/strong\u003e: ±3% full scale\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency Response\u003c\/strong\u003e: 10-1000Hz\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eTransmitter Temperature\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: -35°C to +85°C (-31°F to +185°F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e: -52°C to +100°C (-62°F to +212°F)\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eProbe Temperature\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: -52°C to +177°C (-62°F to +351°F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e: -52°C to +177°C (-62°F to +351°F)\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eEnvironmental Conditions\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e: 100% condensing, non-submerged, with protection of coaxial connectors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection Level\u003c\/strong\u003e: IP65, ensuring the device is dust-tight and protected against water jets.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eDimensions and Weight\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions\u003c\/strong\u003e: 100.1mm (Length) x 73.9mm (Width) x 53.3mm (Height)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight\u003c\/strong\u003e: Approximately 0.43kg\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eThis robust and reliable wire vibration transmitter is engineered to operate in harsh environments, providing accurate and consistent performance across a wide range of temperatures and conditions. Its compact design and durable construction make it a versatile solution for various industrial applications.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":49051138294042,"sku":"990-10-XX-01-00","price":2800.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/990-10-XX-01-001.jpg?v=1717066327"},{"product_id":"990-04-xx-01-00-bently-nevada-vibration-transmitter","title":"990-04-XX-01-00 | Bently Nevada | Vibration Transmitter","description":"\u003cp\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eThe Bently Nevada Model 990-04-XX-01-00 Wire Vibration Transmitter is a precision instrument designed to monitor mechanical equipment condition and diagnose faults. This transmitter detects cable vibrations and converts these signals into standard voltage\/current outputs, ensuring effective monitoring and maintenance of mechanical systems.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVibration Detection\u003c\/strong\u003e: Efficiently detects cable vibrations, providing critical data for monitoring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Conversion\u003c\/strong\u003e: Transforms detected vibration signals into a standard 4-20mA output, compatible with a variety of monitoring systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCondition Monitoring\u003c\/strong\u003e: Essential for mechanical equipment condition monitoring and fault diagnosis, facilitating proactive maintenance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Option\u003c\/strong\u003e: Includes 35 mm DIN rail clips for straightforward installation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry-Specific Approvals\u003c\/strong\u003e: Complies with specific regulatory standards based on the country of application.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e: 24VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Signal\u003c\/strong\u003e: 4-20mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e: 0-50mm\/s\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy\u003c\/strong\u003e: ±3% full scale\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency Response\u003c\/strong\u003e: 10-1000Hz\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eTransmitter Temperature\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: -35°C to +85°C (-31°F to +185°F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e: -52°C to +100°C (-62°F to +212°F)\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eProbe Temperature\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: -52°C to +177°C (-62°F to +351°F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e: -52°C to +177°C (-62°F to +351°F)\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eEnvironmental Conditions\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e: 100% condensing, non-submerged, with protection for coaxial connectors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection Level\u003c\/strong\u003e: IP65, ensuring the device is dust-tight and protected against water jets.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eDimensions and Weight\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions\u003c\/strong\u003e: 100.1mm (Length) x 73.9mm (Width) x 53.3mm (Height)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight\u003c\/strong\u003e: Approximately 0.43kg\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eThe 990-04-XX-01-00 model is engineered for durability and high performance in harsh environments, providing accurate and reliable measurements across a wide temperature range. Its compact size and robust build make it an ideal solution for various industrial applications.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":49051189772570,"sku":"990-04-XX-01-00","price":2500.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/990-08-XX-01-CN3_4dd5911a-a2a9-4ffd-af71-0801fa81a2de.jpg?v=1717066416"},{"product_id":"ge-mark-vie-is220paich1a-analog-input-output-basic-module","title":"GE Mark VIe IS220PAICH1A Analog Input\/Output Basic Module","description":"\u003cp\u003e\u003cstrong\u003eIS220PAICH1A Technical Specifications\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eAmbient Temperature Range:\u003c\/strong\u003e -22 to 149°F\u003cbr\u003e\u003cstrong\u003eClass I, Div. 2, Groups A, B, C, D Standard:\u003c\/strong\u003e ANSI\/ISA - 12. 12.01-2015\u003cbr\u003e\u003cstrong\u003eFunctional Acronym\/Abbreviation:\u003c\/strong\u003e PAIC\u003cbr\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e General Electric Company USA, GE Industrial Systems\u003cbr\u003e\u003cstrong\u003eModel Type:\u003c\/strong\u003e Analog I\/O Pack\u003cbr\u003e\u003cstrong\u003eNon-Hazardous Certification:\u003c\/strong\u003e UL E207865\u003cbr\u003e\u003cstrong\u003ePart Number:\u003c\/strong\u003e IS220PAICH1A\u003cbr\u003e\u003cstrong\u003ePower Supply:\u003c\/strong\u003e Min. 27.4 VDC, Nominal 28.0 VDC, Max. 28.6 VDC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eThe \u003cstrong\u003eIS220PAICH1A\u003c\/strong\u003e is an Analog I\/O Pack designed for use in both hazardous and non-hazardous locations. It features four indicators on the front and an I\/O port at the bottom. The power supply range for the pack is between 27.4 VDC and 28.6 VDC.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eWith certifications for hazardous locations including Class I, Zone 2 Group IIC, Class I Division 2 Groups A, B, C, D, and ATEX Zone 2 Group IIC, as well as non-hazardous locations, the IS220PAICH1A is versatile. Certifications include UL E207685 and UL DEMKO 12 ATEX 1114875X.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCompatible Models\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eCompatible models include the IS200STAIH1A, IS200STAIH2A, and IS20TBAIH1C, all referred to as input-output terminal boards.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eTypical Usage\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eThe IS220PAICH1A is typically installed in either thirteen or twenty-one slot VME racks, often as part of a triple modular redundant architecture system, comprising an individual control module, I\/O net, and main processor card.\u003c\/p\u003e","brand":"GE","offers":[{"title":"Default Title","offer_id":49053199827226,"sku":"IS220PAICH1A","price":900.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/IS220PDOAH1A1_7bf7557e-8bb4-49e7-be2e-e45a9ef42f89.jpg?v=1717162283"},{"product_id":"ge-mark-vie-is220pprfh1b-profibus-master-gateway-i-o-module","title":"GE Mark VIe IS220PPRFH1B PROFIBUS Master Gateway I\/O Module","description":"\u003cp\u003e\u003cstrong\u003eIS220PPRFH1B Technical Specifications\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eAmbient Temperature Rating:\u003c\/strong\u003e -20 to +55°C (-4 to +131°F)\u003cbr\u003e\u003cstrong\u003eATEX Zone 2, Group IIC Certification:\u003c\/strong\u003e UL DEMKO 12 ATEX 1114875X\u003cbr\u003e\u003cstrong\u003eInput Current:\u003c\/strong\u003e Max 0.18 Adc\u003cbr\u003e\u003cstrong\u003eInput Voltage:\u003c\/strong\u003e Nominal 28Vdc\u003cbr\u003e\u003cstrong\u003eNon-Hazardous Certification:\u003c\/strong\u003e UL E207685\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eThe \u003cstrong\u003eIS220PPRFH1B\u003c\/strong\u003e is a Gas Turbine Control model from General Electric's Speedtronic Fanuc Mark VIe series, serving as a PROFIBUS DPM Master Gateway Input\/Output Module. Typically paired with the IS200SPIDG1A accessory ID terminal board, it facilitates attachment and mounting in ordinary or non-hazardous locations.\u003c\/p\u003e\u003cp\u003eThe unit operates with a power supply rated for a range of 27.4 - 28.6 V dc.\u003c\/p\u003e","brand":"GE","offers":[{"title":"Default Title","offer_id":49053388079386,"sku":"IS220PPRFH1B","price":1300.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/IS220PDOAH1A_3_c916f0ad-8c39-42a2-885b-15af6a4f9646.jpg?v=1717162514"},{"product_id":"ur-6th-ge-multilin-digital-i-o-module","title":"UR-6TH GE Multilin Digital I\/O Module","description":"\u003cp\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e General Electric Multilin\u003cbr\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e UR-6TH\u003cbr\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e 7\"x6\"x1.5\"\u003cbr\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e 2 lb, 9 oz\u003cbr\u003e\u003cstrong\u003eManufacturing Location:\u003c\/strong\u003e Markham, Ontario, Canada\u003cbr\u003e\u003cstrong\u003eSoftware:\u003c\/strong\u003e EnerVista UR\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eProduct Description:\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eThe UR-6TH module by General Electric Multilin is designed to provide digital inputs and outputs to the relay it integrates with. These inputs and outputs facilitate communication between the relay and various equipment within the power system, thereby enhancing overall system efficiency. This module variant specifically features 4 Form-A (non-monitored) outputs and 8 contact inputs. The UR series offers a range of modules with diverse functionalities, so users are advised to refer to the user manual for module selection.\u003c\/p\u003e\u003cp\u003eInstallation of the UR-6TH module is straightforward, thanks to the modular design of the Universal Relays series. This series is known for its scalability, allowing for the addition and adjustment of modules behind the faceplate to adapt to evolving power system management requirements. When upgrading the system, it's crucial to replace modules with counterparts of similar specifications.\u003c\/p\u003e\u003cp\u003eDigital I\/O modules like the UR-6TH facilitate swift and secure communication, reducing or eliminating the need for costly and time-consuming hardwiring. Notably, the Form-A digital outputs in this module version boast rapid activation speeds, typically less than 4 milliseconds.\u003c\/p\u003e","brand":"GE","offers":[{"title":"Default Title","offer_id":49054124474650,"sku":"UR-6TH","price":900.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/UR-6TH_4_c11f9c57-89e8-47f9-b152-8b0162e44d4e.jpg?v=1717157049"},{"product_id":"ic693alg223-ge-fanuc-16-channel-analog-voltage-input-module","title":"IC693ALG223 GE Fanuc 16-Channel Analog Voltage Input Module","description":"\u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eThe 16-Channel Analog Current Input module offers up to 16 single-ended input channels, each equipped to convert an analog input signal into a digital value suitable for various application needs. This module features three distinct input ranges:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e4 to 20 mA\u003c\/li\u003e\n\u003cli\u003e0 to 20 mA\u003c\/li\u003e\n\u003cli\u003e4 to 20 mA Enhanced\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eSpecifications for IC693ALG223 - 16-Channel Analog Current Input Module\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eNumber of Channels:\u003c\/strong\u003e 1 to 16 selectable; single ended\u003cbr\u003e\u003cstrong\u003eInput Current Ranges:\u003c\/strong\u003e 0 to 20 mA, 4 to 20 mA, and 4 to 20 mA Enhanced (selectable per channel)\u003cbr\u003e\u003cstrong\u003eCalibration:\u003c\/strong\u003e Factory calibrated to:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e4 µA per count on 4 to 20 mA range\u003c\/li\u003e\n\u003cli\u003e5 µA per count on 0 to 20 mA and 4 to 20 mA Enhanced range\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eUpdate Rate:\u003c\/strong\u003e 13 msec (all 16 channels)\u003cbr\u003e\u003cstrong\u003eResolution at 4-20 mA:\u003c\/strong\u003e 4 µA (4 µA\/bit)\u003cbr\u003e\u003cstrong\u003eResolution at 0-20 mA:\u003c\/strong\u003e 5 µA (5 µA\/bit)\u003cbr\u003e\u003cstrong\u003eResolution at 4-20 mA Enhanced:\u003c\/strong\u003e 5 µA (5 µA\/bit)\u003cbr\u003e\u003cstrong\u003eAbsolute Accuracy:\u003c\/strong\u003e ± 0.25% of full scale @ 25°C (77°F); ± 0.5% of full scale over specified operating temperature range\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eLinearity:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u0026lt; 1 LSB from 4 to 20 mA (4 to 20 mA range)\u003c\/li\u003e\n\u003cli\u003e\u0026lt; 1 LSB from 100 µA to 20 mA (0 to 20 mA and 4 to 20 mA Enhanced ranges)\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eIsolation:\u003c\/strong\u003e 1500 volts between field side and logic side\u003cbr\u003e\u003cstrong\u003eCommon Mode Voltage:\u003c\/strong\u003e 0 volts (single-ended channels)\u003cbr\u003e\u003cstrong\u003eCross-Channel Rejection:\u003c\/strong\u003e \u0026gt; 80 dB from DC to 1 kHz\u003cbr\u003e\u003cstrong\u003eInput Impedance:\u003c\/strong\u003e 250 ohms\u003cbr\u003e\u003cstrong\u003eInput Low Pass Filter Response:\u003c\/strong\u003e 19 Hz\u003cbr\u003e\u003cstrong\u003eExternal Supply Voltage Range:\u003c\/strong\u003e 20 to 30 VDC\u003cbr\u003e\u003cstrong\u003eExternal Supply Voltage Ripple:\u003c\/strong\u003e 10%\u003cbr\u003e\u003cstrong\u003eInternal Power Consumption:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e120 mA from the +5 volt bus on the backplane\u003c\/li\u003e\n\u003cli\u003e65 mA from 24 VDC external user supply (in addition to current loop currents)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE","offers":[{"title":"Default Title","offer_id":49054306271514,"sku":"IC693ALG223","price":900.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/IC693ALG223_3.jpg?v=1717241767"},{"product_id":"ic693mdl940-ge-fanuc-series-90-30-relay-output-module","title":"IC693MDL940 GE Fanuc Series 90-30 Relay Output Module","description":"\u003cp\u003e\u003cstrong\u003e\u003cem\u003eOverview: Series 90-30 and PACSystems\u003c\/em\u003e MDL940 2 Amp Relay Output Module**\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eThe Series 90*-30 and PACSystems* MDL940 2 Amp Relay Output module offers 16 normally-open relay circuits designed to control output loads. Each output has a switching capacity of 2 Amps. These outputs are organized into four groups, each consisting of four points, with a common power output terminal for each group.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003cp\u003e\u003cstrong\u003eVersatile Control:\u003c\/strong\u003e The relay outputs can manage a diverse range of load devices, including motor starters, solenoids, and indicators.\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003e\u003cstrong\u003ePower Source:\u003c\/strong\u003e Power for the internal relay circuits is sourced from the +24 volt DC bus on the backplane.\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003e\u003cstrong\u003eVisual Status Indication:\u003c\/strong\u003e Individual numbered LEDs provide clear ON\/OFF status indication for each output point, facilitating monitoring and troubleshooting.\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003e\u003cstrong\u003eHigh-Voltage Capability:\u003c\/strong\u003e Identified by red bands on the label, the MDL940 module is designated as a high-voltage module.\u003c\/p\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eInstallation and Compatibility:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003cp\u003e\u003cstrong\u003eSystem Compatibility:\u003c\/strong\u003e The module is compatible with both Series 90*-30 and RX3i systems, offering flexibility in system integration.\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003e\u003cstrong\u003eInstallation Flexibility:\u003c\/strong\u003e This module can be installed in any I\/O slot within the Series 90-30 or RX3i system, allowing for convenient placement based on system requirements.\u003c\/p\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003ePower Supply Requirements:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eUser Responsibility:\u003c\/strong\u003e While the module is powered by the +24 volt DC bus on the backplane, users are responsible for supplying AC or DC power to operate field devices connected to this module.\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Voltage:\u003c\/strong\u003e 24 volts DC, 120\/240 VAC (nominal - see the following table for exceptions)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Voltage:\u003c\/strong\u003e\u003cul\u003e\n\u003cli\u003e5 to 30 volts DC\u003c\/li\u003e\n\u003cli\u003e5 to 250 VAC, 50\/60 Hz\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutputs per Module:\u003c\/strong\u003e 16 (four groups of four outputs each)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation:\u003c\/strong\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eField to Backplane and to Frame:\u003c\/strong\u003e 250 VAC continuous; 1500 VAC for 1 minute\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGround Point to Point:\u003c\/strong\u003e 250 VAC continuous; 1500 VAC for 1 minute\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Load:\u003c\/strong\u003e\u003cul\u003e\n\u003cli\u003e2 Amps pilot duty maximum per output\u003c\/li\u003e\n\u003cli\u003e4 Amps maximum per common\u003c\/li\u003e\n\u003cli\u003e16 amps maximum per module\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMinimum Load:\u003c\/strong\u003e 10mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Inrush:\u003c\/strong\u003e 5 Amps\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOn Response Time:\u003c\/strong\u003e 15ms maximum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOff Response Time:\u003c\/strong\u003e 15ms maximum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Consumption, all outputs on:\u003c\/strong\u003e\u003cul\u003e\n\u003cli\u003e7mA from 5 volt bus on backplane\u003c\/li\u003e\n\u003cli\u003e135mA from relay 24V bus on backplane\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE","offers":[{"title":"Default Title","offer_id":49054706041114,"sku":"IC693MDL940","price":900.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/IC693MDL940.jpg?v=1717241200"},{"product_id":"ge-fanuc-ic697mdl740-series-90-70-discrete-output-module","title":"GE Fanuc IC697MDL740 Series 90-70 Discrete Output Module","description":"\u003cp\u003e\u003cstrong\u003eIC697MDL740 24\/48 Volt DC, 2-Amp, 16-Point Output Module\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e16 Output Points\u003c\/strong\u003e: Four isolated groups of four points each.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e3 Amps Capacity per Point\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Inrush Capacity\u003c\/strong\u003e: 10 times the rated current.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eFunctions\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eThe 24\/48 Volt DC 2 Amp Output Module offers 16 output points in four isolated groups, allowing flexibility in usage across different AC phases. Each group is individually fused for protection with a 10-amp fuse. The module accommodates high inrush currents, suitable for various inductive and incandescent loads, including size-4 contactors.\u003c\/p\u003e\u003cp\u003eLED indicators display the ON\/OFF status of each point, with corresponding circuit labeling provided on the module. An additional \"FUSE\" indicator illuminates if a fuse opens. The module is mechanically keyed for correct replacement.\u003c\/p\u003e\u003cp\u003eI\/O references are user-configurable through PLC programming software, eliminating the need for DIP switches or jumpers.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSpecifications for IC697MDL740\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Voltage:\u003c\/strong\u003e 24 or 48 volts DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutputs per Module:\u003c\/strong\u003e 16 (four groups of four outputs each)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation:\u003c\/strong\u003e\u003cul\u003e\n\u003cli\u003e1500 volts – any output to backplane\u003c\/li\u003e\n\u003cli\u003e500 volts between groups\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Voltage Range:\u003c\/strong\u003e 20 to 60 volts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Current:\u003c\/strong\u003e\u003cul\u003e\n\u003cli\u003e2 amps maximum per point\u003c\/li\u003e\n\u003cli\u003e4 amps maximum per group\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Characteristics:\u003c\/strong\u003e\u003cul\u003e\n\u003cli\u003eInrush Current: 20 amps maximum for 20 ms\u003c\/li\u003e\n\u003cli\u003eOutput Voltage Drop: 0.8 volt (0.4 ohm) maximum\u003c\/li\u003e\n\u003cli\u003eResponse Time–On: 2 ms maximum\u003c\/li\u003e\n\u003cli\u003eResponse Time–Off: 2 ms maximum\u003c\/li\u003e\n\u003cli\u003eOutput Leakage: 1 mA maximum\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Required from 5V Bus:\u003c\/strong\u003e 0.15 amp\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVME Compatibility:\u003c\/strong\u003e System designed to support the VME standard C.1\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE","offers":[{"title":"Default Title","offer_id":49055127044378,"sku":"IC697MDL740","price":800.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/IC697MDL740_9e6d8656-a7cf-47a7-b8aa-39daed9dca64.jpg?v=1717301215"},{"product_id":"honeywell-cc-paoh01-hart-analog-output-module","title":"Honeywell CC-PAOH01 HART Analog Output Module","description":"\u003cp\u003e\u003cstrong\u003eHoneywell CC-PAOH01 HART Analog Output Module\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e The Honeywell CC-PAOH01 is a HART analog output module designed for use in industrial automation and process control systems. This module is part of Honeywell's Experion Series-C I\/O system and is used to provide precise and reliable analog output signals to various field devices such as actuators, valves, and other control elements.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e16-Channel Output:\u003c\/strong\u003e The module supports 16 independent analog output channels, enabling simultaneous control of multiple process variables.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Accuracy:\u003c\/strong\u003e Delivers reliable 24VDC analog signals with high precision, ensuring accurate process control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHART Protocol:\u003c\/strong\u003e Integrates HART (Highway Addressable Remote Transducer) communication for real-time diagnostics and remote configuration, enhancing maintenance and troubleshooting capabilities.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExtensive Diagnostics:\u003c\/strong\u003e Equipped with extensive self-diagnostics to monitor and report the health status of the module, reducing downtime and maintenance efforts.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptional Redundancy:\u003c\/strong\u003e Supports redundancy to enhance reliability and ensure continuous operation in critical applications.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Range:\u003c\/strong\u003e 4-20mA with loop current monitoring\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannel Current:\u003c\/strong\u003e Up to 460mA per channel\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication Protocol:\u003c\/strong\u003e HART\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Dimensions:\u003c\/strong\u003e 263 mm x 58 mm x 28 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 540 g (shipping weight 2kg)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Specifications:\u003c\/strong\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -40 to 70°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e -40 to 85°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity:\u003c\/strong\u003e 5 to 95% non-condensing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertifications:\u003c\/strong\u003e CE, RoHS\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e The CC-PAOH01 module is used in a variety of industrial applications where precise control of analog outputs is required. Common applications include chemical processing, oil and gas, power generation, and manufacturing processes that rely on accurate actuation and control of field devices.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":49060169744666,"sku":"CC-PAOH01","price":700.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/CC-PAIN0151410069-175.jpg?v=1717154398"},{"product_id":"honeywell-cc-pdil01-digital-input-24v-module","title":"Honeywell CC-PDIL01 Digital Input 24V Module","description":"\u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e The Honeywell CC-PDIL01 is a digital input module designed for use in industrial automation and process control systems. It is a part of Honeywell's Experion Series C I\/O system, which integrates seamlessly with the C300 controller to provide reliable and accurate monitoring of digital signals from various field devices such as switches and sensors.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e32 Channels:\u003c\/strong\u003e Supports 32 digital input channels, allowing for extensive monitoring and control capabilities.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Accuracy:\u003c\/strong\u003e Offers a high accuracy of ±0.1% of full scale, ensuring precise signal processing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWide Input Range:\u003c\/strong\u003e Can handle input voltages ranging from 0 to 30 VDC, making it versatile for different applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Reliability:\u003c\/strong\u003e Designed for high reliability and long service life, resistant to dust, moisture, and vibration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact Design:\u003c\/strong\u003e Features a compact design that facilitates easy integration and installation within control cabinets.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Type:\u003c\/strong\u003e Digital (dry contact)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Range:\u003c\/strong\u003e 0 to 30 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Impedance:\u003c\/strong\u003e \u0026gt;10 MΩ\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy:\u003c\/strong\u003e ±0.1% of full scale\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply:\u003c\/strong\u003e 24 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Specifications:\u003c\/strong\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e 0 to 60°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e -40 to 85°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity:\u003c\/strong\u003e 5 to 95% non-condensing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 263 mm x 58 mm x 28 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 1 kg (shipping weight approximately 2 kg)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertifications:\u003c\/strong\u003e CE, RoHS\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cspan\u003e The CC-PDIL01 module is ideal for use in various industrial environments where monitoring and processing of digital signals are required. Typical applications include monitoring of switches, sensors, and other discrete devices in manufacturing plants, power generation facilities, and chemical processing plants.\u003c\/span\u003e\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":49060220272922,"sku":"CC-PDIL01","price":700.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/8C-PDILA1_4.jpg?v=1717154584"},{"product_id":"cc-paih02-honeywell-hart-analog-input-module","title":"CC-PAIH02 Honeywell HART Analog Input Module","description":"\u003cp\u003e\u003cstrong\u003eHoneywell HART Analog Input Module CC-PAIH02\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e The Honeywell CC-PAIH02 is a high-level analog input module designed to integrate with Honeywell's Experion Series-C I\/O system. It supports HART communication, allowing for the transmission of digital information alongside the analog signal, which is essential for configuring and monitoring smart field devices.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e16 High-Level Input Channels:\u003c\/strong\u003e Accommodates up to 16 analog input channels, facilitating the connection of multiple transmitters and sensors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHART Communication:\u003c\/strong\u003e Enables real-time diagnostics and remote configuration of HART-enabled devices, improving maintenance efficiency and system monitoring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNon-Incendive Field Power:\u003c\/strong\u003e Suitable for hazardous environments, providing safe power supply for field instruments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eComprehensive Self-Diagnostics:\u003c\/strong\u003e Advanced diagnostic capabilities to monitor module health and identify potential issues, ensuring high reliability.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptional Redundancy:\u003c\/strong\u003e Supports redundant configurations to enhance system reliability and availability.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInnovative Design:\u003c\/strong\u003e Features vertical mounting and detachable terminals for efficient installation and effective heat management within control cabinets.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Type:\u003c\/strong\u003e Current (2-wire or self-powered transmitters)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Range:\u003c\/strong\u003e 4-20 mA (through 200 Ω)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResolution:\u003c\/strong\u003e 16-bit A\/D converter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy:\u003c\/strong\u003e ± 0.075% of full-scale (at 23.5°C ± 2°C)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommon Mode Rejection Ratio:\u003c\/strong\u003e 70 dB\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNormal Mode Rejection Ratio:\u003c\/strong\u003e 19 dB\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Requirements:\u003c\/strong\u003e 24 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature Range:\u003c\/strong\u003e 0 to 60°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 263 mm x 138 mm x 88 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 1 kg\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e The CC-PAIH02 module is utilized in various industrial settings, including:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcess Control:\u003c\/strong\u003e Monitoring and controlling critical process parameters in industries such as chemical, oil and gas, and power generation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial Automation:\u003c\/strong\u003e Integrating with automation systems to connect and process analog signals from a wide range of industrial sensors and actuators.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilding Automation:\u003c\/strong\u003e Used for monitoring and controlling building systems like HVAC, lighting, and security.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":49060280860954,"sku":"CC-PAIH02","price":600.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/HoneywellCC-PAIH01.jpg?v=1717158658"},{"product_id":"fc-tdol-07120-honeywell-digital-output-module","title":"FC-TDOL-07120 Honeywell Digital Output Module","description":"\u003cp\u003e\u003cstrong\u003eIntroduction\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eThe \u003cstrong\u003eTDOL-07120 Field Termination Assembly Module\u003c\/strong\u003e serves as an interface for field loads requiring 120Vac or 120Vdc line-monitored digital outputs. It features 7 fused relay contact outputs with a maximum load of 240VA or 150W each.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eMain Functions and Usage\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eConnects to SDO-0824 output module and SDI-1624 input module via system interconnection cables.\u003c\/li\u003e\n\u003cli\u003eControls 7 output relays through channels 1 to 7 of the SDO-0824, with LED indication of relay states.\u003c\/li\u003e\n\u003cli\u003eLine-monitoring circuits on each output channel, controlled by channel 8 of the SDO-0824 and wired to channels 1 to 15 of the SDI-1624.\u003c\/li\u003e\n\u003cli\u003eDrives outputs and processes line monitoring results with special application logic.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eType Numbers:\u003c\/strong\u003e FS-TDOL-07120, FC-TDOL-07120\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals:\u003c\/strong\u003e CE, UL, CSA, TUV\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Channels:\u003c\/strong\u003e 7\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax. Output Current:\u003c\/strong\u003e 2A (at 120V AC)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Load:\u003c\/strong\u003e Resistive or inductive up to 240VA\/150W\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Supply Voltage:\u003c\/strong\u003e 120V AC or 120V DC +\/- 20%\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFuse Rating:\u003c\/strong\u003e 2A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax Switched Power:\u003c\/strong\u003e 1250VA \/ 60 Watts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExpected Life:\u003c\/strong\u003e 100,000 electrical switch operations, 30,000,000 mechanical switch operations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhysical Dimensions:\u003c\/strong\u003e 240 x 109 x 71 mm (L x W x H)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":49060731289882,"sku":"FC-TDOL-07120","price":600.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/FC-TSAI-1620M_2_bafaa4ac-af41-4673-8671-853e5c430407.jpg?v=1717307191"},{"product_id":"3501e-invensys-triconex-digital-input-module","title":"3501E Invensys Triconex Digital Input Module","description":"\u003cp\u003e\u003cstrong\u003eVoltage\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e115 VAC\/VDC\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003eOpto-Isolated, Non-Commoned\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003eTMR (Triple Modular Redundancy)\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e3501E\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003ePoints\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e32, non-commoned, isolated\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eAC Range\/DC Range\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e90-155 VAC\/VDC\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eFrequency Range\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003eDC or 47-63 Hz\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eMaximum Voltage\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e155 VAC\/VDC\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eSwitching Level\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOFF to ON:\u003c\/strong\u003e Greater than 86 VAC\/VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eON to OFF:\u003c\/strong\u003e Less than 28 VAC\/VDC\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eNominal Turn-On\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e6-9 mA\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eTypical Hysteresis\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e32 VAC\/VDC\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eInput Delay\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOFF to ON:\u003c\/strong\u003e Less than 8 ms\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eON to OFF:\u003c\/strong\u003e Less than 15 ms\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003ePoint Isolation\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e1500 VDC \/ 2500 VDC\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eNominal Input Impedance\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003eGreater than 8.5 KΩ\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eNominal Field Power Load\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003ePer ON Point:\u003c\/strong\u003e\u003cul\u003e\n\u003cli\u003eAt maximum field voltage: 1.5 watts\u003c\/li\u003e\n\u003cli\u003e2.9 watts\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eDiagnostic Indicators\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Status:\u003c\/strong\u003e 1 per point\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Status:\u003c\/strong\u003e PASS, FAULT, ACTIVE\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eStuck Test\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003eNot applicable\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eColor Code\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003eRed\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003eThe 3501E Triconex Model is a high-performance, opto-isolated module designed for critical industrial applications. With features such as non-commoned points, robust point isolation, and comprehensive diagnostic indicators, it ensures reliable and efficient operation in demanding environments.\u003c\/p\u003e","brand":"Triconex","offers":[{"title":"Default Title","offer_id":49066205643034,"sku":"3501E","price":900.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/4210_2.jpg?v=1717216898"},{"product_id":"3504e-invensys-triconex-high-density-digital-input-module","title":"3504E Invensys Triconex High Density Digital Input Module","description":"\u003cp\u003e\u003cstrong\u003eSpecifications and Features\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e\u003cstrong\u003e3504E\u003c\/strong\u003e\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003eTMR (Triple Modular Redundancy)\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eVoltage\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e24 or 48 VDC (selected using the TriStation software)\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003ePoints\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e64, commoned, DC coupled\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eDC Range\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e20-72 VDC\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eMaximum Voltage\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e72 VDC\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eSwitching Level\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli style=\"list-style-type: none;\"\u003e\u003cul\u003e\n\u003cli\u003e24 V:\n\u003cul\u003e\n\u003cli\u003eOFF to ON: Greater than 18 VDC\u003c\/li\u003e\n\u003cli\u003eON to OFF: Less than 6 VDC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e48 V:\n\u003cul\u003e\n\u003cli\u003eOFF to ON: Greater than 32 VDC\u003c\/li\u003e\n\u003cli\u003eON to OFF: Less than 11 VDC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eNominal Turn-On\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003eNegligible\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eTypical Hysteresis\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e4 VDC\/7 VDC\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eInput Delay\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli style=\"list-style-type: none;\"\u003e\u003cul\u003e\n\u003cli\u003eOFF to ON: Less than 10 ms\u003c\/li\u003e\n\u003cli\u003eON to OFF: Less than 10 ms\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eMinimum Point Isolation\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003eNot applicable\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eNominal Input Impedance\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003eGreater than 30 KΩ\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eNominal Field Power Load\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003eNegligible\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eDiagnostic Indicators\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli style=\"list-style-type: none;\"\u003e\u003cul\u003e\n\u003cli\u003eInput Status: 1 per point\u003c\/li\u003e\n\u003cli\u003eModule Status: PASS, FAULT, ACTIVE\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eStuck Test\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003eON and OFF\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eColor Code\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003eDark Red\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e 4.7 to 6.0 lbs. (2.1 kg. to 2.7 kg)\u003c\/p\u003e\u003cp\u003eThe 3504E models are advanced modules designed for industrial applications, offering robust performance with high diagnostic capabilities. The 3564 is a single module with a broad DC range and quick response times, while the 3504E is a TMR module providing enhanced redundancy and reliability, with voltage selection flexibility. Both models feature detailed diagnostic indicators and are color-coded dark red for easy identification.\u003c\/p\u003e","brand":"Triconex","offers":[{"title":"Default Title","offer_id":49066325475610,"sku":"3504E","price":700.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/4351B_1.jpg?v=1717216954"},{"product_id":"3703e-invensys-triconex-isolated-analog-input-module","title":"3703E Invensys Triconex Isolated Analog Input Module","description":"\u003cp\u003e\u003cstrong\u003eAnalog Input Modules Overview\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eIntroduction\u003c\/strong\u003e Analog Input (AI) Modules consist of three independent input channels. Each channel receives variable voltage signals, converts them to digital values, and transmits these values to the three Main Processor modules upon request. In Triple Modular Redundancy (TMR) mode, a mid-value selection algorithm ensures correct data for every scan. Each input point is sensed in a way that prevents a single channel failure from affecting other channels. Ongoing diagnostics for each channel detect failures, activating the module's Fault indicator and the chassis alarm signal. The Fault indicator signals a channel fault, not a module failure, allowing the module to operate with up to two faulty channels. AI Modules support hot-spare capability for online replacement of faulty modules. They require an external termination panel (ETP) and are mechanically keyed for proper installation in a Tricon chassis.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eModule Specifications\u003c\/strong\u003e\u003cstrong\u003eModel Numbers:\u003c\/strong\u003e 3703E\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eVoltage:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e3703E: 0-5V or 0-10V, + 6% (selectable using TriStation 1131)\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eType:\u003c\/strong\u003e TMR, AI\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eNumber of Input Points:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e3703E: 16, differential, isolated\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eIsolated Points:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e3703E: Yes\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eInput Update Rate:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e3703E: 50 ms\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eResolution:\u003c\/strong\u003e 12 bits\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eAccuracy:\u003c\/strong\u003e \u0026lt; .15% of Full Scale Range (FSR), from 0° to 60°C\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eInput Resistance (load):\u003c\/strong\u003e 30 MΩ (DC), minimum\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePower-Off Resistance:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e3703E: 30 MΩ (DC), minimum\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eCommon Mode Rejection:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e3703E: -90 dB @ 60Hz, minimum; -100 dB @ DC, minimum\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eCommon Mode Range:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e3703E: +200V peak\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eLeg-to-Leg Isolation:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e3703E: 20 KΩ, typical\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eNormal Mode Rejection:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eAt 8Hz: -3 dB\u003c\/li\u003e\n\u003cli\u003eAt 60Hz: -17 dB\u003c\/li\u003e\n\u003cli\u003eAt 120Hz: -23 dB\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eInput Overrange Protection:\u003c\/strong\u003e 150 VDC\/115 VAC continuous\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCurrent Range:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e3703E: 0-20 mA, 250 Ω shunt for 5V, 500 Ω shunt for 10V\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eDiagnostic Indicators:\u003c\/strong\u003e Pass, Fault, Active\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e3703E: Mustard yellow\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eConclusion\u003c\/strong\u003e Analog Input Modules are integral components designed for reliability and accuracy, featuring independent input channels, comprehensive diagnostics, and the ability to operate despite channel failures. They are equipped with various safety and operational features, making them suitable for critical applications.\u003c\/p\u003e","brand":"Triconex","offers":[{"title":"Default Title","offer_id":49066469720346,"sku":"3703E","price":800.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/3704E_1_1c59727e-e1bd-4089-864b-c476a85b1100.jpg?v=1717217459"},{"product_id":"invensys-triconex-3721-tmr-analog-input-module","title":"Invensys Triconex 3721 TMR Analog Input Module","description":"\u003cp\u003e\u003cstrong\u003eIntroduction: \u003c\/strong\u003eAnalog Input (AI) Modules are designed to receive variable voltage signals, convert them to digital values, and transmit these values to the Main Processor modules. These modules support Triple Modular Redundancy (TMR) mode, ensuring data accuracy through a mid-value selection algorithm. Each module conducts ongoing diagnostics and supports hot-spare capability for online replacement. They require an external termination panel (ETP) and are keyed for proper installation in a Tricon chassis.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eModule Specifications\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eModel Numbers:\u003c\/strong\u003e 3721\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eVoltage:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e3721: 0 to 5VDC or -5 to +5VDC, +6%\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eType:\u003c\/strong\u003e TMR, AI\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eNumber of Input Points:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e3721: 32 differential, DC-coupled\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eIsolated Points:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e3721: Yes\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eInput Update Rate:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e3721: 10 ms\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eResolution:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e3721: 12 bits or 14 bits programmable\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eAccuracy:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e3721: \u0026lt; 0.15% of FSR from 0° to 60°C\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eInput Resistance (load):\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e3721: 10 MΩ (DC), minimum\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003ePower-Off Resistance:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e3721: 140 kΩ (DC), typical\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eCommon Mode Rejection:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e3721: -85 dB (DC - 100 Hz)\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eCommon Mode Range:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e3721: -12V to +12V peak\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eLeg-to-Leg Isolation:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e3721: 420 kΩ, typical\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eNormal Mode Rejection:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e3721: -3 dB @ 23Hz, -8 dB @ 60Hz, -14 dB @ 120Hz\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eInput Overrange Protection:\u003c\/strong\u003e 150 VDC\/115 VAC continuous\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCurrent Range:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e3721: 0-20 mA with 250 Ω shunt resistor\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eDiagnostic Indicators:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e3721: PASS, FAULT, ACTIVE, FIELD\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e3721: Yellow\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e: 4.7 to 6.0 lbs. (2.1 kg. to 2.7 kg.)\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eConclusion\u003c\/strong\u003e Analog Input Modules, with their various specifications and diagnostic capabilities, are essential for ensuring accurate and reliable data transmission in critical applications. Their support for TMR mode, ongoing diagnostics, and hot-spare capability makes them suitable for robust and fault-tolerant systems.\u003c\/p\u003e","brand":"Triconex","offers":[{"title":"Default Title","offer_id":49066535649562,"sku":"3721","price":1050.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/3720_3.jpg?v=1717162327"},{"product_id":"invensys-triconex-3625-digital-24vdc-output-modules","title":"Invensys Triconex 3625 Digital 24VDC Output Modules","description":"\u003cp\u003e\u003cstrong\u003eIntroduction\u003c\/strong\u003e Supervised Digital Output (SDO) modules are designed for critical control programs where outputs may remain in a single state for extended periods. These modules receive output signals from the Main Processors across three channels, which are then voted on by a fault-tolerant quadruplicated output switch. This switch passes a single voted output signal to the field termination.\u003c\/p\u003e\u003cp\u003eSDO modules incorporate voltage and current loopback circuitry with online diagnostics to verify the operation of each output switch, the field circuit, and the presence of a load, ensuring complete fault coverage without influencing the output signal. They detect various field faults, including power loss, open or missing loads, field shorts, and shorted loads in the de-energized state. Fault detection triggers appropriate alarms, and these modules support hot-spare capability. An external termination panel (ETP) is required for these modules.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eModule Specifications\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eModel Numbers:\u003c\/strong\u003e 3625\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eNominal Voltage:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e24 VDC\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eType:\u003c\/strong\u003e TMR, Supervised\/Non-Supervised DO\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOutput Signals:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e32, commoned\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eVoltage Range:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e16-32 VDC\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eMaximum Voltage:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e36 VDC\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eVoltage Drop:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e\u0026lt; 2.8 VDC @ 1.7A, typical\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003ePower Module Load:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e\u0026lt; 13 watts\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eCurrent Ratings (Maximum):\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e1.7A per point, 7A surge per 10 ms\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eMinimum Required Load:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e10 mA\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eLoad Leakage:\u003c\/strong\u003e 4 mA maximum\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFuses (on Field Termination):\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003eN\/A—self-protecting\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003ePoint Isolation:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e1,500 VDC\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eDiagnostic Indicators:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOn or Off State:\u003c\/strong\u003e 1 per point\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Status:\u003c\/strong\u003e PASS, FAULT, ACTIVE\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField Alarm:\u003c\/strong\u003e POWER, LOAD (1 per point)\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003eDark blue\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e: 4.7 to 6.0 lbs. (2.1 kg. to 2.7 kg.)\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eConclusion\u003c\/strong\u003e Supervised Digital Output Modules provide robust and reliable output control for critical systems, featuring comprehensive fault detection and diagnostic capabilities. They support hot-spare functionality and are designed to handle extended periods of output stability, making them suitable for demanding industrial applications.\u003c\/p\u003e","brand":"Triconex","offers":[{"title":"Default Title","offer_id":49066631495962,"sku":"3625","price":800.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/3624_3.jpg?v=1717162364"},{"product_id":"3636r-invensys-triconex-relay-output-module","title":"3636R Invensys Triconex Relay Output Module","description":"\u003cp\u003e\u003cstrong\u003eIntroduction\u003c\/strong\u003e The Model 3636R Relay Output (RO) Modules are designed for non-critical points that are not compatible with \"high-side\" solid-state output switches, such as interfacing with annunciator panels. These modules receive output signals from the Main Processors across three channels, which are then voted upon to drive 32 individual relays.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eModule Specifications\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eModel Numbers:\u003c\/strong\u003e 3636R\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eType:\u003c\/strong\u003e Non-triplicated, RO\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePoints:\u003c\/strong\u003e 32, non-commoned\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eVoltage Range:\u003c\/strong\u003e 125 VAC\/VDC, maximum\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCurrent Load:\u003c\/strong\u003e 2A, maximum\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eMinimum Permissible Load:\u003c\/strong\u003e 10 mA, 5 VDC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSwitching Power, Resistive:\u003c\/strong\u003e 2,000 VA, 150 watts maximum\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePoint Isolation:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e1,500 VDC\u003cbr\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eFuses:\u003c\/strong\u003e 1 per output (2.5A fast-acting)\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDiagnostic Indicators:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Status:\u003c\/strong\u003e 1 per point\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Status:\u003c\/strong\u003e PASS, FAULT, ACTIVE\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eOutput Contact:\u003c\/strong\u003e Normally Open\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e Silver Blue\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWeight: \u003c\/strong\u003e4.7 to 6.0 lbs. (2.1 kg. to 2.7 kg.)\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eConclusion\u003c\/strong\u003e The Relay Output modules offer reliable control for non-critical points, featuring independent relay operation verified by loopback circuits and ongoing diagnostics. They support hot-spare functionality and are suitable for applications where solid-state output switches are not compatible.\u003c\/p\u003e","brand":"Triconex","offers":[{"title":"Default Title","offer_id":49066674061594,"sku":"3636R","price":900.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/3624_2_17077921-b791-4a99-b67f-8594306eb039.jpg?v=1717217273"},{"product_id":"3603e-triconex-dc-digital-output-module","title":"3603E Triconex DC Digital Output Module","description":"\u003cp\u003e\u003cstrong\u003eTMR Digital Output Modules Overview\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eIntroduction\u003c\/strong\u003e TMR Digital Output (DO) modules receive output signals from the Main Processors across three channels. These signals are then voted by special quadruplicated output circuitry, providing redundancy for critical signal paths. Each module incorporates a voltage-loopback circuit to verify the operation of each output switch independently. Ongoing diagnostics ensure channel and circuit integrity.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eModule Specifications\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003e16-Point Digital Output Module Specifications\u003c\/strong\u003e\u003cstrong\u003eModel Numbers:\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eNominal Voltage:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e120 VDC\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eType:\u003c\/strong\u003e TMR, DO\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOutput Signals:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e16, commoned (3603E\/T),\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eVoltage Range:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e90-150 VDC\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eVoltage Drop:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e\u0026lt; 1.5V, typical\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eCurrent Ratings, Maximum:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e0.8A per point, 4A surge\/10 ms \u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eLoad Leakage:\u003c\/strong\u003e 2 mA maximum @ 60 Hz\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFuses (on Field Termination):\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e1 per output, 1.0A fast-acting\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003ePoint Isolation:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e1,500 VDC\/ 2,500 VDC\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eDiagnostic Indicators:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOn or Off state:\u003c\/strong\u003e 1 per point\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Status:\u003c\/strong\u003e PASS, FAULT, ACTIVE\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField Alarm:\u003c\/strong\u003e LOAD\/FUSE\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e Blue\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eConclusion\u003c\/strong\u003e TMR Digital Output Modules ensure safe and reliable operation of critical systems by providing redundant output circuits and comprehensive diagnostics. They support hot-spare capability and are designed for compatibility with various voltage ranges and signal types.\u003c\/p\u003e","brand":"Triconex","offers":[{"title":"Default Title","offer_id":49066729406746,"sku":"3603E","price":950.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/3009_1_f5d0d83f-8858-4807-9310-83d05524c736.jpg?v=1717217049"},{"product_id":"honeywell-tk-iah061-analog-input-module-6-point-high-level","title":"Honeywell TK-IAH061 Analog Input Module 6-Point High Level","description":"\u003cp\u003e\u003cstrong\u003eSpecifications – Traditional I\/O Modules\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eTC-IAH061, TK-IAH061\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eTable 6-6 High Level Analog, 6-Input, Voltage and Current (10 V \u0026amp; 4-20 mA) Module\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eParameter Specification\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eNumber of Points\u003c\/strong\u003e 6 galvanically isolated channels\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eInput Voltage Range (Voltage)\u003c\/strong\u003e 10.50 VDC maximum\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eInput Current Range (Current)\u003c\/strong\u003e 0 to 21.0 mA (with 249Ω resistor)\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eVoltage Resolution\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003e16 bits across each range shown below\u003c\/strong\u003e\u003cul\u003e\n\u003cli\u003e±10.5 volt range: 343 μV typical (15 bits + sign)\u003c\/li\u003e\n\u003cli\u003e0 to 10.5 volt range: 171 μV typical\u003c\/li\u003e\n\u003cli\u003e0 to 5.25 volt range: 86 μV typical\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eCurrent Resolution\u003c\/strong\u003e 0.34 μA\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eInput Impedance\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage\u003c\/strong\u003e: Greater than 10 MΩ\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent\u003c\/strong\u003e: 249Ω\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eOpen Circuit Detection\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage\u003c\/strong\u003e: Upscale reading\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent\u003c\/strong\u003e: Zero scale reading\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eTypical Open Circuit Detection Time\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage\u003c\/strong\u003e: 5 seconds\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent\u003c\/strong\u003e: 1 second\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eNormal Mode Noise Rejection\u003c\/strong\u003e Greater than 60 dB @ 60 Hz\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCommon Mode Rejection\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e120 dB @ 60 Hz\u003c\/li\u003e\n\u003cli\u003e100 dB @ 50 Hz\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eChannel Bandwidth\u003c\/strong\u003e 0 to 15 Hz (-3 dB)\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSettling Time to 5% of Full Scale\u003c\/strong\u003e Less than 80 milliseconds\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCalibrated Accuracy @ 25°C\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage\u003c\/strong\u003e: Better than 0.1% of range\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent\u003c\/strong\u003e: Better than 0.15% of range including 0.05% sense resistor\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eModule Update Rate for All Channels\u003c\/strong\u003e 25 ms\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eRFI Immunity\u003c\/strong\u003e Error of less than 2.0% of range at 10 V\/m, 27 to 1000 MHz\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOvervoltage Capability\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage\u003c\/strong\u003e: 120 VAC\/VDC continuous at room temperature\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent\u003c\/strong\u003e: 8 VAC\/VDC with on-board current resistor\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eInput Offset Drift with Temperature\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage\u003c\/strong\u003e: 2 μV\/°C typical\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent\u003c\/strong\u003e: 8.0 μV\/°C typical\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eGain Drift with Temperature\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage\u003c\/strong\u003e: 35 ppm\/°C typical\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent\u003c\/strong\u003e: 45 ppm\/°C typical\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003ePower Dissipation\u003c\/strong\u003e 4.3 W max\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eBackplane Current\u003c\/strong\u003e See Module Power Consumption Data, page 46.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eIsolation Voltage\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannel to channel\u003c\/strong\u003e: 100% tested at 2546 VDC for 1 second\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUser to system\u003c\/strong\u003e: 100% tested at 2546 VDC for 1 second\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eConnection Terminal Blocks\u003c\/strong\u003e TC-TBNH, 20-position terminal block\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWeight :\u003c\/strong\u003e 0.25 kg\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":49070744076570,"sku":"TK-IAH061","price":700.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/TK-IAH061_1.jpg?v=1717242254"},{"product_id":"honeywell-tk-idd321-32-point-discrete-input-module","title":"Honeywell TK-IDD321 32-Point Discrete Input Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe TK-IDD321 is a 24 VDC, 32-Point Discrete Input Module designed for high-performance industrial automation systems. This module features 32 discrete inputs, grouped in 16 points per common, making it highly efficient for various input applications.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Input Capacity\u003c\/strong\u003e: Accommodates 32 discrete inputs, supporting a wide range of industrial input devices.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Range\u003c\/strong\u003e: Operates efficiently within a voltage range of 10-31.2 VDC at temperatures up to 60°C across all channels.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation\u003c\/strong\u003e: Ensures safety with 1500 VDC isolation tested between channels and from user to system.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Inputs\u003c\/strong\u003e: 32 (16 points\/common)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOn-stage Voltage Range\u003c\/strong\u003e: 10-31.2 VDC @ 60°C all channels\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNominal Input Voltage\u003c\/strong\u003e: 24 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOn-State Current (Minimum)\u003c\/strong\u003e: 2 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOff-State Voltage (Maximum)\u003c\/strong\u003e: 5 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOff-State Current (Maximum)\u003c\/strong\u003e: 1.5 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation Voltage\u003c\/strong\u003e:\n\u003cul\u003e\n\u003cli\u003eChannel to channel: 1500 VDC for 1 second\u003c\/li\u003e\n\u003cli\u003eUser to system: 1500 VDC for 1 second\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInput Delay Time\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOff to On\u003c\/strong\u003e:\n\u003cul\u003e\n\u003cli\u003eHardware delay: 1 ms maximum plus filter time\u003c\/li\u003e\n\u003cli\u003eProgrammable filter: 0 ms, 1 ms, or 2 ms\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOn to Off\u003c\/strong\u003e:\n\u003cul\u003e\n\u003cli\u003eHardware delay: 1 ms maximum plus filter time\u003c\/li\u003e\n\u003cli\u003eProgrammable filter: 0 ms, 1 ms, 2 ms, 9 ms, or 18 ms\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003ePower Dissipation\u003c\/h3\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eMaximum Power Dissipation\u003c\/strong\u003e: 6.1 W\u003c\/li\u003e\u003c\/ul\u003e\u003ch3\u003eShort\/Inrush Current\u003c\/h3\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003ePeak Short\/Inrush Current\u003c\/strong\u003e: 250 mA (decaying to \u0026lt;37% in 22 ms, without activation)\u003c\/li\u003e\u003c\/ul\u003e\u003ch3\u003eInput Compatibility\u003c\/h3\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eCompliance\u003c\/strong\u003e: IEC Type 1+\u003c\/li\u003e\u003c\/ul\u003e\u003ch3\u003eBackplane Current\u003c\/h3\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eReference\u003c\/strong\u003e: See Module Power Consumption Data, page 46.\u003c\/li\u003e\u003c\/ul\u003e\u003ch3\u003eConnection\u003c\/h3\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eTerminal Blocks\u003c\/strong\u003e: TC-TBCH, 36-position terminal block\u003c\/li\u003e\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":49070777598234,"sku":"TK-IDD321","price":900.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/TK-IOLI0151403427-17551309283-600_4.jpg?v=1717236294"},{"product_id":"honeywell-tc-odd321-experion-dc-output-module","title":"Honeywell TC-ODD321 Experion DC Output Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe 24 VDC, 32-Point Discrete Output Module is engineered for reliable performance in industrial automation systems. It offers a high-density output configuration with 32 outputs, organized in groups of 16 points per common, and ensures robust and efficient control for various output devices.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Output Capacity\u003c\/strong\u003e: Supports 32 discrete outputs, divided into 16 points per common, ideal for complex automation needs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWide Output Voltage Range\u003c\/strong\u003e: Operates within a 10-31.2 VDC range at 50°C with linear derating, ensuring flexibility and reliability in diverse conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfigurable Fault and Program States\u003c\/strong\u003e: Allows setting fault states and program mode states to Hold Last State, ON, or OFF for each point, providing enhanced control and safety.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Outputs\u003c\/strong\u003e: 32 (16 points\/common)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Voltage Range\u003c\/strong\u003e:\n\u003cul\u003e\n\u003cli\u003e10-31.2 VDC @ 50°C (Linear derating)\u003c\/li\u003e\n\u003cli\u003e10-28 VDC @ 60°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Current Rating\u003c\/strong\u003e:\n\u003cul\u003e\n\u003cli\u003ePer Point: 0.5A maximum @ 50°C (Linear derating), 0.35A maximum @ 60°C\u003c\/li\u003e\n\u003cli\u003ePer Module: 16A maximum @ 50°C (Linear derating), 10A maximum @ 60°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSurge Current\u003c\/strong\u003e: 1A for 10ms each, repeatable every 2s @ 60°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlash On Time\u003c\/strong\u003e: 100 µsec target, 150 µsec max\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOn-State Current Load (Minimum)\u003c\/strong\u003e: 3.0 mA per output\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOn-State Voltage Drop (Maximum)\u003c\/strong\u003e:\n\u003cul\u003e\n\u003cli\u003e1 VDC @ rated current per point\u003c\/li\u003e\n\u003cli\u003e3 VDC for IEC 1131-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOff-State Leakage Current (Maximum)\u003c\/strong\u003e:\n\u003cul\u003e\n\u003cli\u003e0.5 mA per point\u003c\/li\u003e\n\u003cli\u003e1 mA per point for IEC 1131-2 for 0.25 A output\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eConfigurable Settings\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFault States per Point\u003c\/strong\u003e: Configurable to Hold Last State, ON, or OFF (default OFF)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStates in Program Mode per Point\u003c\/strong\u003e: Configurable to Hold Last State, ON, or OFF (default OFF)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eProtection and Safety\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFusing\u003c\/strong\u003e: Not protected. It is recommended to use Fused IFM to protect outputs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReverse Polarity Protection\u003c\/strong\u003e: None. Incorrect wiring may damage outputs.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eOutput Delay Time\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOff to On\u003c\/strong\u003e: 1.0 ms maximum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOn to Off\u003c\/strong\u003e: 1.0 ms maximum\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003ePower Dissipation\u003c\/h3\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eMaximum Power Dissipation\u003c\/strong\u003e: 6.1 W\u003c\/li\u003e\u003c\/ul\u003e\u003ch3\u003eBackplane Current\u003c\/h3\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eReference\u003c\/strong\u003e: See Module Power Consumption Data, page 46.\u003c\/li\u003e\u003c\/ul\u003e\u003ch3\u003eIsolation Voltage\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGroup to Group\u003c\/strong\u003e: 100% tested at 2546V DC for 1 second (250V AC maximum continuous voltage between groups)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUser to System\u003c\/strong\u003e: 100% tested at 2546V DC for 1 second\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eConnection\u003c\/h3\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eTerminal Blocks\u003c\/strong\u003e: TC-TBCH, 36-position terminal block\u003c\/li\u003e\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":49070810136858,"sku":"TC-ODD321","price":600.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/TC-ODD321_1.jpg?v=1717235644"},{"product_id":"honeywell-fc-tsai-1620m-safety-analog-input-module","title":"Honeywell FC-TSAI-1620M Safety Analog Input Module","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\u003cp\u003eThe TSAI-1620m is a Safe 0-20 mA and 4-20 mA Analog Input Field Termination Assembly (FTA) module. It serves as a crucial interface between field components, such as sensors, and the high-density analog input module SAI-1620m in Safety Manager systems. This module is specifically designed for use in Class I, Division 2 hazardous locations, ensuring safe and reliable operation in challenging environments.\u003c\/p\u003e\u003ch3\u003eMain Functions\u003c\/h3\u003e\u003cp\u003eThe TSAI-1620m module performs three primary functions:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Conversion\u003c\/strong\u003e: Converts 0(4)-20 mA DC field signals to the signal levels required by the SAI-1620m module.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply Distribution\u003c\/strong\u003e: Distributes power to each transmitter with voltage-current limitation, ensuring compliance with hazardous area standards.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Monitoring\u003c\/strong\u003e: Monitors the external power connected to the FTA module.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ch4\u003eGeneral\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eType Numbers\u003c\/strong\u003e: FS-TSAI-1620m, FC-TSAI-1620m\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals\u003c\/strong\u003e: CE, TUV, UL, CSA, FM\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eInput\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Channels\u003c\/strong\u003e: 16 (2 groups of 8 channels with common 0 V)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Requirements\u003c\/strong\u003e: 30 V DC external, 3 mA (without input loop loads)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Current\u003c\/strong\u003e: 0-25 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Resistance\u003c\/strong\u003e: 250 Ω (± 1%)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eOutput\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTo Passive Transmitters (Vext)\u003c\/strong\u003e:\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Resistance\u003c\/strong\u003e: 270 Ω (± 5%)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIgniting Current per Channel\u003c\/strong\u003e: \u0026lt; 120 mA at 30 V DC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTo SAI-1620m Module\u003c\/strong\u003e:\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Voltage\u003c\/strong\u003e: 0-4 V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy\u003c\/strong\u003e: 0.10%\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eFuse\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRating\u003c\/strong\u003e: 315 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions\u003c\/strong\u003e: 5x20 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Rating AC\u003c\/strong\u003e: 125 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Output Current per Fuse\u003c\/strong\u003e: 220 mA\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003ePhysical\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Dimensions\u003c\/strong\u003e: 210 × 70 × 60 mm (8.26 × 2.76 × 2.36 in)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDIN EN Rails\u003c\/strong\u003e: TS32 \/ TS35 × 7.5\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUsed Rail Length\u003c\/strong\u003e: 211 mm (8.30 in)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 0.43kg\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eTermination\u003c\/h4\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eScrew Terminals\u003c\/strong\u003e:\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax. Wire Diameter\u003c\/strong\u003e: 2.5 mm² (AWG 14)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStrip Length\u003c\/strong\u003e: 7 mm (0.28 in)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTightening Torque\u003c\/strong\u003e: 0.5 Nm (0.37 ft-lb)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":49070888616218,"sku":"FC-TSAI-1620M","price":600.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/FC-TSAI-1620M_1_8f0aa3c5-393e-4830-a24c-60927247b348.jpg?v=1717238175"},{"product_id":"invensys-triconex-3481-ao3481-analog-output-module","title":"Invensys Triconex 3481 AO3481 Analog Output Module","description":"\u003ch4\u003eAnalog Output Modules\u003c\/h4\u003e\u003cp\u003eEach TMR Analog Output Module has three isolated sets of electronics, called channels, which independently accept data from the MP associated with each channel. The channels provide input to voter circuitry to select a single channel to drive the output. Special circuitry is used to ensure that the channels that are not driving the output are shunted so they cannot affect the output.\u003c\/p\u003e\u003cp\u003eAO Modules include complete, ongoing diagnostics for each channel. If the diagnostics detect a failure on any channel, the Fault indicator turns on and activates the system alarm. The Fault indicator identifies a channel fault, not a complete module failure. AO Modules are guaranteed to operate properly in the presence of a single fault and may continue to operate properly with multiple faults. AO Modules support a hot-spare module. Each AO Module is mechanically keyed to prevent improper installation in a configured baseplate.\u003c\/p\u003e\u003ch3\u003eModel 3481 AO Module Baseplate Compatibility\u003c\/h3\u003e\u003cp\u003eThe Model 3481 AO Module can be used with these baseplates:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel 2481\u003c\/strong\u003e: Used in typical applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel 2483\u003c\/strong\u003e: Enables communication between HART field devices and Configuration and Asset Management Software running on a PC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel 2483A\u003c\/strong\u003e: Used in hazardous locations and enables communication between HART field devices and Configuration and Asset Management Software running on a PC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDO External Termination Baseplate\u003c\/strong\u003e: Used with the Model 9863-610 External Termination Panel in hazardous locations. Note that “DO” is not a typo; the DO External Termination Baseplate is used with the 9863-610.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eModel 3481 Analog Output Module Specifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePoints\u003c\/strong\u003e: 4, commoned-return, DC-coupled\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolated Points\u003c\/strong\u003e: None\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Current Range\u003c\/strong\u003e:\n\u003cul\u003e\n\u003cli\u003e4–20 mA output, controlled\u003c\/li\u003e\n\u003cli\u003e0–22 mA over-range\u003c\/li\u003e\n\u003cli\u003e0 mA output capability (step function \u0026lt; 2 mA)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Accuracy\u003c\/strong\u003e: \u0026lt;0.25% (in range of 4–20 mA) of FSR (0–22 mA), from 32° F to 158° F (0° C to 70° C)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType\u003c\/strong\u003e: TMR\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResolution\u003c\/strong\u003e: 12 bits\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiagnostic\u003c\/strong\u003e: Forced-switch diagnostic (FSD)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExternal Loop Power\u003c\/strong\u003e:\n\u003cul\u003e\n\u003cli\u003eReverse voltage-protected\u003c\/li\u003e\n\u003cli\u003e32 VDC, maximum\u003c\/li\u003e\n\u003cli\u003e24 VDC, nominal\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Loop Power Requirements for Specified Load\u003c\/strong\u003e:\n\u003cul\u003e\n\u003cli\u003e300 Ω @ \u0026gt;16 VDC (1 A minimum)\u003c\/li\u003e\n\u003cli\u003e500 Ω @ \u0026gt;20 VDC (1 A minimum)\u003c\/li\u003e\n\u003cli\u003e700 Ω @ \u0026gt;24 VDC (1 A minimum)\u003c\/li\u003e\n\u003cli\u003e800 Ω @ \u0026gt;28 VDC (1 A minimum)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOver-Range Protection\u003c\/strong\u003e:\n\u003cul\u003e\n\u003cli\u003e36 VDC, continuous\u003c\/li\u003e\n\u003cli\u003e0 VDC, continuous\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitch Time on Leg Failure\u003c\/strong\u003e:\n\u003cul\u003e\n\u003cli\u003e1 ms, typical\u003c\/li\u003e\n\u003cli\u003e3 ms, maximum\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Triconex","offers":[{"title":"Default Title","offer_id":49073288872218,"sku":"AO3481","price":900.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/AO34813.jpg?v=1717235538"},{"product_id":"allen-bradley-1771-ow16-digital-i-o-relay-contact-output-modules","title":"Allen Bradley 1771-OW16 Digital I\/O Relay Contact Output Modules","description":"\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ch4\u003eDescription\u003c\/h4\u003e\u003cp\u003eThe Allen Bradley 1771 Output Module is a versatile and robust component designed for industrial automation systems. It provides reliable output capabilities with various voltage and current ratings, making it suitable for a wide range of applications. This module is designed for use in specific I\/O chassis models and offers efficient power and thermal dissipation characteristics.\u003c\/p\u003e\u003ch4\u003eFeatures\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutputs per Module\u003c\/strong\u003e: 16\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Location\u003c\/strong\u003e: Compatible with 1771-A1B through -A4B I\/O Chassis; 1771-AM1 or -AM2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Rating\u003c\/strong\u003e:\n\u003cul\u003e\n\u003cli\u003eAC: 24–250V rms, 47–63Hz\u003c\/li\u003e\n\u003cli\u003eDC: 24–150V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Rating\u003c\/strong\u003e:\n\u003cul\u003e\n\u003cli\u003eDC: 80 Watts per output (max); 1280 Watts per module (max)\u003c\/li\u003e\n\u003cli\u003eAC: 500 VA per output (max); 1440 VA per module (max)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ecos Φ\u003c\/strong\u003e: 0.4\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Rating (Maximum per Channel)\u003c\/strong\u003e: Refer to Table 2 on page 7\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Surge Current\u003c\/strong\u003e:\n\u003cul\u003e\n\u003cli\u003eDC: 2A maximum per output (at rated power)\u003c\/li\u003e\n\u003cli\u003eAC: Refer to Table 3 on page 7\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMinimum Contact Load\u003c\/strong\u003e: 10mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperate\/Release Time\u003c\/strong\u003e: 10ms maximum; 5ms (+1ms) typical\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBounce Time\u003c\/strong\u003e: Maximum 4ms\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitching Frequency\u003c\/strong\u003e: Maximum 1\/3Hz at maximum load\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExpected Life of Electrical Contacts\u003c\/strong\u003e: 300,000 operations at 25°C (cos Φ = 1)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Dissipation\u003c\/strong\u003e:\n\u003cul\u003e\n\u003cli\u003eAll relays off: 0.015 Watts\u003c\/li\u003e\n\u003cli\u003eAll relays on: 6.55 Watts\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal Dissipation\u003c\/strong\u003e:\n\u003cul\u003e\n\u003cli\u003eAll relays off: 0.05 BTU\/hr\u003c\/li\u003e\n\u003cli\u003eAll relays on: 22.24 BTU\/hr\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane Current\u003c\/strong\u003e: 1.3A maximum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Cable Length\u003c\/strong\u003e: 1000 ft (304.8 m)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation Voltage\u003c\/strong\u003e:\n\u003cul\u003e\n\u003cli\u003e1500V AC for 1s customer side to system side\u003c\/li\u003e\n\u003cli\u003eRelay rated 4000V coil to contact\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eConductors\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWire Size\u003c\/strong\u003e: 14 gauge stranded maximum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsulation\u003c\/strong\u003e: 3\/64 inch maximum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCategory\u003c\/strong\u003e: 14\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eEnvironmental Conditions\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperational Temperature\u003c\/strong\u003e: 0°C to 60°C (32°F to 140°F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e: -40°C to 85°C (-40°F to 185°F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e: 5 to 95% (without condensation)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eAdditional Information\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eKeying\u003c\/strong\u003e: Between 2 and 4; Between 32 and 34\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField Wiring Arm Catalog Number\u003c\/strong\u003e: 1771-WN\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring Arm Screw Torque\u003c\/strong\u003e: 7–9 inch-pounds\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eThe Allen Bradley 1771 Output Module is engineered for durability and reliable performance in demanding industrial environments, providing flexible connectivity and robust operational capabilities.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":49073976541466,"sku":"1771-OW16","price":800.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/1771-OW16_3.jpg?v=1717309578"},{"product_id":"mc-paih03-honeywell-high-level-analog-input-module","title":"MC-PAIH03 Honeywell High Level Analog Input Module","description":"\u003ch2\u003eHoneywell MC-PAIH03 Analog Processor - Precision 16-Channel Industrial Input\u003c\/h2\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: Honeywell | \u003cstrong\u003eModel\u003c\/strong\u003e: MC-PAIH03 (51304754-150)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Types\u003c\/strong\u003e: 0-5V, 1-5V, 0.4-2V, 4-20mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy\u003c\/strong\u003e: ±0.075% FS (room temp)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResolution\u003c\/strong\u003e: 16-bit A\/D converter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eScan Rate\u003c\/strong\u003e: 4 samples\/sec per channel\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Protection\u003c\/strong\u003e: ±30V damage-proof\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower\u003c\/strong\u003e: 24V DC | \u003cstrong\u003eWeight\u003c\/strong\u003e: 0.6kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemp Range\u003c\/strong\u003e: 0°C to 50°C operational\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eKey Advantages\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #1976d2;\"\u003e60dB crosstalk rejection\u003c\/strong\u003e between channels\u003c\/li\u003e\n\u003cli\u003e10MΩ input impedance for minimal loading\u003c\/li\u003e\n\u003cli\u003eANSI\/IEEE surge protection standard\u003c\/li\u003e\n\u003cli\u003eDifferential inputs reduce noise errors\u003c\/li\u003e\n\u003cli\u003eCompact design saves control panel space\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eEasy Installation\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eDIN-rail mounting (35mm standard)\u003c\/li\u003e\n\u003cli\u003eTool-free spring terminals\u003c\/li\u003e\n\u003cli\u003eHot-swappable during operation\u003c\/li\u003e\n\u003cli\u003ePre-wired FTA compatibility\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eMaintenance \u0026amp; Diagnostics\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eContinuous self-diagnostics\u003c\/li\u003e\n\u003cli\u003eLED status indicators\u003c\/li\u003e\n\u003cli\u003eAuto-calibration function\u003c\/li\u003e\n\u003cli\u003eMTBF: 150,000+ hours\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSystem Compatibility\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFTA Series: MU-TAIH02, TAIH12, TAIH52, etc.\u003c\/li\u003e\n\u003cli\u003eHoneywell Experion PKS\u003c\/li\u003e\n\u003cli\u003eModbus RTU\/TCP protocols\u003c\/li\u003e\n\u003cli\u003eLegacy DCS systems\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eCertifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eCE, UL, cULus\u003c\/li\u003e\n\u003cli\u003eIEC 61131-2 compliant\u003c\/li\u003e\n\u003cli\u003eRoHS compliant\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003ePackage Contents\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eMC-PAIH03 processor module\u003c\/li\u003e\n\u003cli\u003eInstallation guide\u003c\/li\u003e\n\u003cli\u003eDIN rail clip\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e12-month warranty\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eGlobal Shipping\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFedEx International Priority\u003c\/li\u003e\n\u003cli\u003eUPS Worldwide Express\u003c\/li\u003e\n\u003cli\u003eDHL Express 12:00\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Minimum detectable signal change?\u003c\/strong\u003e\u003cbr\u003eA: 0.0015% full scale resolution\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Maximum wire length?\u003c\/strong\u003e\u003cbr\u003eA: 100m shielded twisted pair\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Humidity tolerance?\u003c\/strong\u003e\u003cbr\u003eA: 5-95% non-condensing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Vibration resistance?\u003c\/strong\u003e\u003cbr\u003eA: 2g @ 10-500Hz (IEC 60068)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Software required?\u003c\/strong\u003e\u003cbr\u003eA: None - operates standalone\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":49074723160346,"sku":"MC-PAIH03","price":850.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/80363975-150MC-PDOY22_3.jpg?v=1717241896"},{"product_id":"07ac91-abb-07-ac-91-analog-i-o-module","title":"07AC91 ABB 07 AC 91 Analog I\/O module","description":"\u003ch3\u003e\u003cstrong\u003eTechnical Data for 07 AC 91 \u003cspan\u003eGJR5252300R0101\u003c\/span\u003e:\u003c\/strong\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePermissible Temperature Range During Operation:\u003c\/strong\u003e 0-55°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated Supply Voltage:\u003c\/strong\u003e 24 V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax. Current Consumption:\u003c\/strong\u003e 0.2 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax. Power Dissipation:\u003c\/strong\u003e 5 W\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection Against Reversed Polarity:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Binary Inputs:\u003c\/strong\u003e 1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Analog Input Channels:\u003c\/strong\u003e 8, up to 16\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Analog Output Channels:\u003c\/strong\u003e 8, up to 16\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical Isolation:\u003c\/strong\u003e CS31 system bus interface and 1 binary input\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAddress Setting and Configuration:\u003c\/strong\u003e Coding switch under cover\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMethod of Connections:\u003c\/strong\u003e Removable screw-type terminal blocks\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax. Length of Analog Cables:\u003c\/strong\u003e 100 m\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConversion Error of Analog Values:\u003c\/strong\u003e Typ. 0.5%, Max. 1%\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax. Permissible Potential Difference:\u003c\/strong\u003e ±1 V between terminals\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimension:\u003c\/strong\u003e 240x140x85 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 450g\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003e\u003cstrong\u003eDisplays and Operating Elements:\u003c\/strong\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e8 green LEDs for channel selection and diagnosis\u003c\/li\u003e\n\u003cli\u003e8 green LEDs for analog value display\u003c\/li\u003e\n\u003cli\u003eList of diagnosis information relating to LEDs\u003c\/li\u003e\n\u003cli\u003eRed LED for error messages\u003c\/li\u003e\n\u003cli\u003eTest button\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003e\u003cstrong\u003eElectrical Connection:\u003c\/strong\u003e\u003c\/h3\u003e\u003cp\u003eThe module can be installed on a DIN rail (15 mm high) or with screws. Electrical connections for input\/output module are detailed.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":49074975244570,"sku":"07-AC-91","price":800.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/07AC91_-1.jpg?v=1721109665"},{"product_id":"abb-ai810-3bse008516r1-analog-input-module","title":"ABB AI810 3BSE008516R1 Analog Input Module","description":"\u003cp\u003e\u003cstrong\u003eFeatures and Benefits\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e8 channels for 0...20 mA, 4...20 mA, 0...10 V, or 2...10 V d.c., single-ended unipolar inputs\u003c\/li\u003e\n\u003cli\u003e1 group of 8 channels isolated from ground\u003c\/li\u003e\n\u003cli\u003e12-bit resolution\u003c\/li\u003e\n\u003cli\u003eInput shunt resistors protected to 30 V by PTC resistor\u003c\/li\u003e\n\u003cli\u003eAnalog inputs are short circuit secured to ZP or +24 V\u003c\/li\u003e\n\u003cli\u003eThe input withstands HART communication.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eGeneral Information\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eArticle number: 3BSE008516R1\u003c\/li\u003e\n\u003cli\u003eType: Analog Input\u003c\/li\u003e\n\u003cli\u003eSignal specification: 0..20mA, 4..20mA, 0..10V, 2..10V\u003c\/li\u003e\n\u003cli\u003eNumber of channels: 8\u003c\/li\u003e\n\u003cli\u003eSignal type: Unipolar single-ended\u003c\/li\u003e\n\u003cli\u003eMechanics: S800\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eDetailed Data\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eResolution: 12 bit\u003c\/li\u003e\n\u003cli\u003eInput impedance: 290 kΩ (voltage input), 230 - 275 kΩ (current input)\u003c\/li\u003e\n\u003cli\u003eIsolation: Groupwise isolated from ground\u003c\/li\u003e\n\u003cli\u003eUnder\/over range: -5% \/ +15%\u003c\/li\u003e\n\u003cli\u003eError: Max. 0.1%\u003c\/li\u003e\n\u003cli\u003eTemperature drift: Voltage: Typ. 70 ppm\/°C Max. 100 ppm\/°C; Current: Typ. 50 ppm\/°C Max. 80 ppm\/°C\u003c\/li\u003e\n\u003cli\u003eInput filter (rise time 0-90%): 140 ms\u003c\/li\u003e\n\u003cli\u003eUpdate cycle time: 8 ms\u003c\/li\u003e\n\u003cli\u003eCurrent limiting: Transmitter power can be current-limited by the MTU\u003c\/li\u003e\n\u003cli\u003eMaximum field cable length: 600 meters (656 yards)\u003c\/li\u003e\n\u003cli\u003eMax input voltage (non-destructive): 30 V d.c.\u003c\/li\u003e\n\u003cli\u003eNMRR, 50Hz, 60Hz: \u0026gt; 40 dB\u003c\/li\u003e\n\u003cli\u003eRated insulation voltage: 50 V\u003c\/li\u003e\n\u003cli\u003eDielectric test voltage: 500 V a.c.\u003c\/li\u003e\n\u003cli\u003ePower dissipation: 1.5 W\u003c\/li\u003e\n\u003cli\u003eCurrent consumption:\n\u003cul\u003e\n\u003cli\u003e+5 V Modulebus: 70 mA\u003c\/li\u003e\n\u003cli\u003e+24 V Modulebus: 40 mA\u003c\/li\u003e\n\u003cli\u003e+24 V external: 0\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eDiagnostics\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eFront LED’s: F(ault), R(un), W(arning)\u003c\/li\u003e\n\u003cli\u003eSupervision: Internal power supply\u003c\/li\u003e\n\u003cli\u003eStatus indication of supervision: Module Error, Module Warning, Channel error\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eEnvironment and Certification\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eCE mark: Yes\u003c\/li\u003e\n\u003cli\u003eElectrical safety: EN 61010-1, UL 61010-1, EN 61010-2-201, UL 61010-2-201\u003c\/li\u003e\n\u003cli\u003eHazardous Location: C1 Div 2 cULus, C1 Zone 2 cULus, ATEX Zone 2\u003c\/li\u003e\n\u003cli\u003eMarine certification: ABS, BV, DNV, LR\u003c\/li\u003e\n\u003cli\u003eTemperature, Operating: 0 to +55 °C (+32 to +131 °F), approvals are issued for +5 to +55 °C\u003c\/li\u003e\n\u003cli\u003eTemperature, Storage: -40 to +70 °C (-40 to +158 °F)\u003c\/li\u003e\n\u003cli\u003ePollution degree: Degree 2, IEC 60664-1\u003c\/li\u003e\n\u003cli\u003eCorrosion protection: ISA-S71.04: G3\u003c\/li\u003e\n\u003cli\u003eRelative humidity: 5 to 95 %, non-condensing\u003c\/li\u003e\n\u003cli\u003eMax ambient temperature: 55 °C (131 °F), for vertical mounting in compact MTU 40 °C (104 °F)\u003c\/li\u003e\n\u003cli\u003eProtection class: IP20 according to IEC 60529\u003c\/li\u003e\n\u003cli\u003eMechanical operating conditions: IEC\/EN 61131-2\u003c\/li\u003e\n\u003cli\u003eEMC: EN 61000-6-4, EN 61000-6-2\u003c\/li\u003e\n\u003cli\u003eOvervoltage categories: IEC\/EN 60664-1, EN 50178\u003c\/li\u003e\n\u003cli\u003eEquipment class: Class I according to IEC 61140; (earth protected)\u003c\/li\u003e\n\u003cli\u003eRoHS compliance: DIRECTIVE\/2011\/65\/EU (EN 50581:2012)\u003c\/li\u003e\n\u003cli\u003eWEEE compliance: DIRECTIVE\/2012\/19\/EU\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eUse with MTU TU810, TU812, TU814, TU818, TU830, TU833, TU835, TU838, TU850\u003c\/li\u003e\n\u003cli\u003eKeying code: AE\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eWidth: 45 mm (1.77”)\u003c\/li\u003e\n\u003cli\u003eDepth: 102 mm (4.01”), 111 mm (4.37”) including connector\u003c\/li\u003e\n\u003cli\u003eHeight: 119 mm (4.7”)\u003c\/li\u003e\n\u003cli\u003eWeight: 0.2 kg (0.44 lbs.)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":49075025772826,"sku":"AI810","price":700.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/AI8103BSE008516R1_2.jpg?v=1717309294"},{"product_id":"6es7332-5hf00-0ab0-siemens-simatic-s7-300-analog-output-sm-332","title":"6ES7332-5HF00-0AB0 Siemens Simatic S7-300 Analog output SM 332","description":"\u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e The Siemens SIMATIC S7-300 Analog Output Module SM 332 is designed for industrial automation systems, providing reliable and accurate analog signal output. It features 8 analog outputs that can handle both voltage and current signals, ensuring compatibility with a wide range of industrial devices and applications. The module supports diagnostics and has high-resolution output for precise control.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolated Analog Outputs\u003c\/strong\u003e: Ensures safety and reliability by providing isolation between channels and the backplane bus.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiagnostics\u003c\/strong\u003e: Equipped with diagnostic functions that can be parameterized, including diagnostic alarms and readable diagnostic information.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShort-Circuit Protection\u003c\/strong\u003e: Voltage outputs are protected against short circuits, enhancing durability and reliability.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVersatile Output Ranges\u003c\/strong\u003e: Supports multiple voltage (0 to 10V, 1 to 5V, -10V to +10V) and current (0 to 20mA, -20mA to +20mA, 4 to 20mA) output ranges​.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eTechnical Parameters\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003cul\u003e\n\u003cli\u003eRated value (DC): 24V\u003c\/li\u003e\n\u003cli\u003eReverse polarity protection: Yes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Current\u003c\/strong\u003e\u003cul\u003e\n\u003cli\u003eFrom load voltage L+ (without load), max.: 340 mA\u003c\/li\u003e\n\u003cli\u003eFrom backplane bus 5V DC, max.: 100 mA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Loss\u003c\/strong\u003e\u003cul\u003e\u003cli\u003eTypical: 6 W\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAnalog Outputs\u003c\/strong\u003e\u003cul\u003e\n\u003cli\u003eNumber of analog outputs: 8\u003c\/li\u003e\n\u003cli\u003eVoltage output, short-circuit current, max.: 25 mA\u003c\/li\u003e\n\u003cli\u003eCurrent output, no-load voltage, max.: 18 V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Ranges\u003c\/strong\u003e\u003cul\u003e\n\u003cli\u003eVoltage: 0 to 10V, 1 to 5V, -10V to +10V\u003c\/li\u003e\n\u003cli\u003eCurrent: 0 to 20mA, -20mA to +20mA, 4 to 20mA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoad Impedance\u003c\/strong\u003e\u003cul\u003e\n\u003cli\u003eVoltage outputs, min.: 1 kΩ\u003c\/li\u003e\n\u003cli\u003eVoltage outputs, capacitive load, max.: 1 µF\u003c\/li\u003e\n\u003cli\u003eCurrent outputs, max.: 500 Ω\u003c\/li\u003e\n\u003cli\u003eCurrent outputs, inductive load, max.: 10 mH\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Length\u003c\/strong\u003e\u003cul\u003e\u003cli\u003eShielded, max.: 200 m\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eAnalog Value Generation for the Outputs\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegration and Conversion Time\/Resolution per Channel\u003c\/strong\u003e\u003cul\u003e\n\u003cli\u003eResolution with overrange (bit including sign), max.: 12 bit; ±10V, ±20mA, 4mA to 20mA, 1V to 5V: 11 bit + sign; 0V to 10V, 0mA to 20mA: 12 bit\u003c\/li\u003e\n\u003cli\u003eConversion time (per channel): 0.8 ms\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSettling Time\u003c\/strong\u003e\u003cul\u003e\n\u003cli\u003eFor resistive load: 0.2 ms\u003c\/li\u003e\n\u003cli\u003eFor capacitive load: 3.3 ms\u003c\/li\u003e\n\u003cli\u003eFor inductive load: 0.5 ms (1 mH), 3.3 ms (10 mH)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eErrors\/Accuracies\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperational Error Limit in Overall Temperature Range\u003c\/strong\u003e\u003cul\u003e\n\u003cli\u003eVoltage, relative to output range: +\/- 0.5%\u003c\/li\u003e\n\u003cli\u003eCurrent, relative to output range: +\/- 0.6%\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBasic Error Limit (Operational Limit at 25°C)\u003c\/strong\u003e\u003cul\u003e\n\u003cli\u003eVoltage, relative to output range: +\/- 0.4%\u003c\/li\u003e\n\u003cli\u003eCurrent, relative to output range: +\/- 0.5%\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eInterrupts\/Diagnostics\/Status Information\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiagnostics Function\u003c\/strong\u003e: Yes, parameterizable\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAlarms\u003c\/strong\u003e: Diagnostic alarm, parameterizable\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiagnostics Indication LED\u003c\/strong\u003e: Group error SF (red)\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003ePotential Separation\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBetween Channels and Backplane Bus\u003c\/strong\u003e: Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBetween Channels and Load Voltage L+\u003c\/strong\u003e: Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBetween Channels and Power Supply of Electronics\u003c\/strong\u003e: Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation\u003c\/strong\u003e: Tested with 500V DC\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eConnection Method\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eRequired Front Connector\u003c\/strong\u003e: 40-pin\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth\u003c\/strong\u003e: 40 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight\u003c\/strong\u003e: 125 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDepth\u003c\/strong\u003e: 117 mm\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eApprox.\u003c\/strong\u003e: 272 g\u003c\/li\u003e\u003c\/ul\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":49077525446938,"sku":"6ES7332-5HF00-0AB0","price":500.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/SIEMENS_29.jpg?v=1717320190"},{"product_id":"dio280-bachmann-digital-input-output-i-o-module","title":"DIO280 Bachmann Digital Input\/output (I\/O) module","description":"\u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e The Bachmann DIO248, DIO264, and DIO280 are versatile digital input\/output (I\/O) modules designed for controlling digital consumers such as contactors, relays, pneumatic and hydraulic valves. They are also suitable for reading signals from digital sensors, detectors, or switches. These modules feature configurable interrupt inputs and counters, making them ideal for various industrial automation applications.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDigital Channels\u003c\/strong\u003e: Available with 48\/64 or 80 digital channels.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfigurable Channels\u003c\/strong\u003e: 16 channels can be configured as either inputs or outputs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInterrupt Inputs\u003c\/strong\u003e: Equipped with 8 configurable interrupt inputs for rapid event response.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCounters\u003c\/strong\u003e: Up to four 32-bit counters for applications such as position detection and goods counting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePWM Output Mode\u003c\/strong\u003e: All outputs can operate in PWM mode for energy-saving operation of inductive loads, with a configurable hold time of up to 2 seconds.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eParallel Connection\u003c\/strong\u003e: Outputs can be connected in parallel if operated in the same mode.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStatus Display\u003c\/strong\u003e: Each channel has an LED status display for easy monitoring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply\u003c\/strong\u003e: Operates on a supply voltage of 18 to 34 VDC, with protection against reverse polarity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact Design\u003c\/strong\u003e: Cost-effective and space-saving design.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eTechnical Parameters\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eInputs\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuantity\u003c\/strong\u003e: 16 to 32 for DIO248, 24 to 40 for DIO264, and 32 to 48 for DIO280.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Range\u003c\/strong\u003e: High: 15 to 34 VDC, Low: 0 to 5 VDC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Delay\u003c\/strong\u003e: Standard 600 µs, adjustable from 10 µs to 270 ms.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInternal Resistance\u003c\/strong\u003e: 8 kΩ.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStatus Indication\u003c\/strong\u003e: Green LED.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInterrupt Inputs\u003c\/strong\u003e: 8, configurable as counter or interrupt inputs.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eCounters\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuantity\u003c\/strong\u003e: Up to 4.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResolution\u003c\/strong\u003e: 32-bit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Modes\u003c\/strong\u003e: Event counter, incremental encoder, gate measurement, cycle time, or frequency measurement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEncoder Types\u003c\/strong\u003e: Incremental encoder with A and B channels, and single-channel pulse encoder.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax Input Frequency\u003c\/strong\u003e: Single-channel: 50 kHz, Dual-channel (A\/B): 20 kHz.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eOutputs\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuantity\u003c\/strong\u003e: 16 to 32 for DIO248, 24 to 40 for DIO264, and 32 to 48 for DIO280.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Range\u003c\/strong\u003e: 18 to 34 VDC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent per Channel\u003c\/strong\u003e: Max. 0.5 A.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotal Current\u003c\/strong\u003e: 16 A for DIO248, 20 A for DIO264, and 24 A for DIO280.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStatus Indication\u003c\/strong\u003e: Green LED.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitching Frequency\u003c\/strong\u003e: Max. 1 kHz with ohmic load.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInductive Breaking Capacity\u003c\/strong\u003e: 1.15 H.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePWM\u003c\/strong\u003e: Configurable like outputs with 13-bit resolution, frequency from 1 Hz to 1 kHz, and holding time up to 2 seconds.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInternal Power Supply\u003c\/strong\u003e: 500 V galvanic isolation from the system.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReverse Polarity Protection\u003c\/strong\u003e: Yes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnergetic Recovery\u003c\/strong\u003e: Sensor energetic recovery when supply is switched off.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e: 24 VDC.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eEnvironmental Conditions\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: Standard: -30 to +60°C, Cold Climate: -40 to +60°C.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity\u003c\/strong\u003e: 5 to 95% without condensation (operation), 5 to 95% with condensation (storage).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePollution Degree\u003c\/strong\u003e: 2 according to IEC 60664-1.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGeneral\u003c\/strong\u003e: CE, cULus, CCC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMarine\u003c\/strong\u003e: DNV GL, LR, ABS, BV.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eIndustrial control systems.\u003c\/li\u003e\n\u003cli\u003eData acquisition systems.\u003c\/li\u003e\n\u003cli\u003eMachine control.\u003c\/li\u003e\n\u003cli\u003eProcess control.\u003c\/li\u003e\n\u003cli\u003eRobotics.\u003c\/li\u003e\n\u003cli\u003eTransportation.\u003c\/li\u003e\n\u003cli\u003eAerospace and defense.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003eW x H x D (mm) \u003c\/span\u003e\u003cspan\u003e110 x 119 x 61mm\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e385g\u003c\/span\u003e\u003c\/p\u003e","brand":"Bachmann","offers":[{"title":"Default Title","offer_id":49077739290906,"sku":"DIO280","price":500.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/DIO280_5.jpg?v=1717314713"},{"product_id":"yokogawa-adv151-e50-digital-input-module","title":"Yokogawa ADV151-E50 Digital Input Module","description":"\u003cp\u003e\u003cstrong\u003eGENERAL\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eThis General Specifications (GS) document outlines the hardware specifications of the Digital I\/O Modules (FIO) suitable for installation in the ESB Bus Node Unit (ANB10S, ANB10D), Optical ESB Bus Node Unit (ANB11S, ANB11D), and the Field Control Unit (AFV30S, AFV30D, AFV40S, AFV40D).\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSTANDARD SPECIFICATIONS\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cem\u003e\u003cstrong\u003eDigital Input Modules\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\u003cp\u003eThe Digital Input Modules are designed to receive 32-channel or 64-channel 24 V DC ON\/OFF signals. The ADV151 and ADV161 models support dual redundant configuration.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eItem Specifications\u003c\/strong\u003e\u003c\/p\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003eADV151-P\/ADV151-E (*1)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of input channels\u003c\/td\u003e\n\u003ctd\u003e32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated input voltage (*2)\u003c\/td\u003e\n\u003ctd\u003e24 V DC (sink\/source)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput ON voltage\u003c\/td\u003e\n\u003ctd\u003e18 to 26.4 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput OFF voltage\u003c\/td\u003e\n\u003ctd\u003e5.0 V DC or less\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput current (at rated input voltage)\u003c\/td\u003e\n\u003ctd\u003e4.1 mA±20% \/ channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum allowable input voltage\u003c\/td\u003e\n\u003ctd\u003e30.0 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWithstanding voltage\u003c\/td\u003e\n\u003ctd\u003eBetween input signal and system: 2 kV AC, For 1 minute \u0026lt;br\u0026gt; Between commons: 500 V AC, For 1 minute, common every 16-channel (*3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunctions\u003c\/td\u003e\n\u003ctd\u003eStatus input Function for detecting ON\/OFF status\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ePushbutton input Function for counting the pushbutton edges\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSOE input Function for capturing the SOE data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput response time\u003c\/td\u003e\n\u003ctd\u003e8 ms or less (for status input)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum ON detection time\u003c\/td\u003e\n\u003ctd\u003e20 ms (for pushbutton input)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum ON\/OFF cycle\u003c\/td\u003e\n\u003ctd\u003e25 Hz (for pushbutton input)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum current consumption\u003c\/td\u003e\n\u003ctd\u003e500 mA (5 V DC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 0.30 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal connection\u003c\/td\u003e\n\u003ctd\u003ePressure clamp terminal, Dedicated cable (AKB331), MIL connector cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003cp\u003e(*1) ADV151-P: Standard type with no explosion protection, ADV151-E: Standard type with explosion protection\u003c\/p\u003e\u003cp\u003e(*2) Sink\/source refers to whether the input is sinking current (when ON) or sourcing current (when OFF).\u003c\/p\u003e\u003cp\u003e(*3) Common refers to the shared connection point for multiple channels.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eMODELS AND SUFFIX CODES\u003c\/strong\u003e\u003cem\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\u003ctr\u003e\n\u003ctd\u003eADV151\u003c\/td\u003e\n\u003ctd\u003eDigital Input Module (32-channel, 24 V DC, Isolated)\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\u003cp\u003e\u003cstrong\u003eSuffix Codes\u003c\/strong\u003e\u003c\/p\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSuffix Code\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e-P\u003c\/td\u003e\n\u003ctd\u003eWith pushbutton input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e-E\u003c\/td\u003e\n\u003ctd\u003eWith SOE capture (*1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e     5\u003c\/td\u003e\n\u003ctd\u003eWithout status display; with no explosion protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e     6\u003c\/td\u003e\n\u003ctd\u003eWith status display; with no explosion protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e     E\u003c\/td\u003e\n\u003ctd\u003eWithout status display; with explosion protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e     F\u003c\/td\u003e\n\u003ctd\u003eWith status display; with explosion protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e        0\u003c\/td\u003e\n\u003ctd\u003eBasic type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e        3\u003c\/td\u003e\n\u003ctd\u003eWith ISA Standard G3 option and temperature (-20 to 70 °C) option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":49078266265882,"sku":"ADV151-E50","price":400.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/ADV151-P60_3.jpg?v=1717316348"},{"product_id":"f-6214-hima-analog-input-module-98-4621402","title":"F 6214 Hima Analog Input Module 98 4621402","description":"\u003cp\u003e\u003cstrong\u003eF 6214: Safety-Related 4-Fold Analog Input Module\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eModule Description:\u003c\/strong\u003e The F 6214 module is designed for safety-critical applications, specifically tailored for transmitters utilizing two-wire technique. It accommodates analog inputs within the range of 4 to 20 mA for transmitters, as well as voltage inputs spanning 0 to 1\/5\/10 V and current inputs ranging from 0 to 20 mA. With a resolution of 12 bits, it adheres to requirement class AK 1 to 6.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eInput Specifications:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eVoltage Range: 0 to 1.06 V (approximately 6% overflow)\u003c\/li\u003e\n\u003cli\u003eDigital Conversion: 0 mV corresponds to 0, while 1 V corresponds to 3840 digital values\u003c\/li\u003e\n\u003cli\u003eDelay After Test: 100 ms\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cem\u003eResistance Configuration (R):\u003c\/em\u003e*\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eShunt Configuration: Utilizes a shunt with a resistance of 50 Ohm\u003c\/li\u003e\n\u003cli\u003ePrecision: 0.05%\u003c\/li\u003e\n\u003cli\u003ePower Rating: 0.125 W\u003c\/li\u003e\n\u003cli\u003eInput Type: Current Input\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e 2.5 cm x 12.7 cm x 20.3 cm\u003cbr\u003e\u003cstrong\u003eWeight: \u003c\/strong\u003e0.1 KG\u003cbr\u003e\u003c\/p\u003e","brand":"HIMA","offers":[{"title":"Default Title","offer_id":49078628909338,"sku":"F-6214","price":500.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/62100_3.jpg?v=1717315814"},{"product_id":"f-3331-hima-8-channel-safety-related-output-module","title":"F 3331 HIMA 8 Channel Safety-Related Output Module","description":"\u003cp\u003e\u003cstrong\u003eModule Description:\u003c\/strong\u003e The F 3331 module is engineered to provide reliable outputs for safety-critical applications. It supports resistive loads or inductive loads up to 500 mA (12 W), as well as lamp connections up to 4 W. Equipped with integrated safety shutdown and safe isolation features, along with line monitoring capabilities, it ensures dependable operation. It conforms to requirement class AK 1 to 6.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eAutomatic Test Routines:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eReading Back of Output Signals: The 0 signal's operating point during readback is ≤ 6.5 V. Up to this value, the 0 signal's level may increase in the event of a fault without detection.\u003c\/li\u003e\n\u003cli\u003eSwitching Capability and Cross-Talking: Ensures proper functionality of test signals and minimizes cross-talk (walking-bittest).\u003c\/li\u003e\n\u003cli\u003eLine Monitoring: Monitors output lines for abnormalities.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eOutput Specifications:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eMaximum Output: 500 mA, short circuit proof\u003c\/li\u003e\n\u003cli\u003eInternal Voltage Drop: Maximum of 2 V at 500 mA load\u003c\/li\u003e\n\u003cli\u003eAdmissible Line Resistance (Input + Output): Maximum of 11 Ohm\u003c\/li\u003e\n\u003cli\u003eUndervoltage Tripping: Occurs at ≤ 16 V\u003c\/li\u003e\n\u003cli\u003eOperating Points (Component Tolerances Effects Value Difference):\n\u003cul\u003e\n\u003cli\u003eShort Circuit Current: 0.75 to 1.5 A\u003c\/li\u003e\n\u003cli\u003eLine Break: 0.5 to 9.5 mA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eOutput Leakage Current: Maximum of 350 µA\u003c\/li\u003e\n\u003cli\u003eOutput Voltage if Output is Reset: Maximum of 1.5 V\u003c\/li\u003e\n\u003cli\u003eCurrent Input for Watchdog (WD): Maximum of 30 mA\u003c\/li\u003e\n\u003cli\u003eDuration of Test Signal: Maximum of 200 µs\u003c\/li\u003e\n\u003cli\u003eSpace Requirement: 4 TE\u003c\/li\u003e\n\u003cli\u003eOperating Data:\n\u003cul\u003e\n\u003cli\u003e5 V DC: 130 mA\u003c\/li\u003e\n\u003cli\u003e24 V DC: 180 mA in additional load\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"HIMA","offers":[{"title":"Default Title","offer_id":49078645031194,"sku":"F-3331","price":600.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/F3331_3.jpg?v=1717315900"},{"product_id":"original-hima-f-3349-digital-output-module","title":"Original Hima F 3349 Digital Output Module","description":"\u003ch3\u003e\u003cstrong\u003eHIMA F 3349 Digital Output Module Description\u003c\/strong\u003e\u003c\/h3\u003e\u003cp\u003eThe HIMA F 3349 Digital Output Module is a highly reliable and efficient component designed for industrial automation and safety applications. It integrates seamlessly into safety-critical systems, providing robust digital output capabilities that ensure consistent and secure operation.\u003c\/p\u003e\u003ch3\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eHigh Reliability and Safety:\u003c\/strong\u003e The HIMA F 3349 is engineered to meet stringent safety standards, making it ideal for use in environments where safety and reliability are paramount. It offers fault tolerance and redundancy features to maintain system integrity even in the event of component failures.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eRobust Design:\u003c\/strong\u003e The module's rugged construction ensures durability and long-term performance in harsh industrial environments. It is built to withstand extreme temperatures, vibrations, and electrical interference.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eVersatile Output Options:\u003c\/strong\u003e This digital output module provides a range of output options to suit various applications. It supports multiple output configurations, allowing for flexible integration into different system architectures.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eEasy Integration:\u003c\/strong\u003e The HIMA F 3349 is designed for easy integration into existing systems. It supports standard communication protocols and interfaces, simplifying the process of connecting with other devices and control systems.\u003c\/p\u003e\u003ch3\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Channels:\u003c\/strong\u003e 16 digital outputs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Voltage:\u003c\/strong\u003e 24 V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Current:\u003c\/strong\u003e 0.5 A per channel\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitching Capacity:\u003c\/strong\u003e 12 W per channel\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse Time:\u003c\/strong\u003e \u0026lt; 10 ms\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiagnostic Functions:\u003c\/strong\u003e Integrated diagnostic capabilities for monitoring and troubleshooting\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003e\u003cstrong\u003eWeight and Dimensions\u003c\/strong\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 300 grams (0.66 lbs)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 150 mm x 50 mm x 100 mm (5.9 in x 2.0 in x 3.9 in)\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eThe HIMA F 3349 Digital Output Module combines advanced safety features with robust performance, making it an ideal choice for critical automation and control applications.\u003c\/p\u003e","brand":"HIMA","offers":[{"title":"Default Title","offer_id":49079523574042,"sku":"F-3349","price":600.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/F3349_6.jpg?v=1717322325"},{"product_id":"07di92-gjr5252400r0101-abb-digital-i-o-module","title":"07 DI 92 GJR5252400R0101 ABB 07DI92 Digital I\/O module","description":"\u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eThe ABB 07DI92 is a digital I\/O module designed for the AC31 series. It features 32 digital inputs (DI) and operates at 24V DC. This module is ideal for use in various industrial automation applications, providing reliable and efficient digital input handling. The 07DI92 module is equipped with a CS31 slave fieldbus interface and is designed for easy installation on DIN rails according to IEC 60715 standards.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e32 Digital Inputs:\u003c\/strong\u003e Provides 32 channels for digital input, suitable for various monitoring and control tasks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e24V DC Operation:\u003c\/strong\u003e Designed to operate with a 24V DC power supply.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCS31 Slave Fieldbus Interface:\u003c\/strong\u003e Ensures compatibility with CS31 bus systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eScrew Terminals:\u003c\/strong\u003e Features pluggable screw terminals for secure and easy wiring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIP20 Protection:\u003c\/strong\u003e Rated with IP20 protection, suitable for typical industrial environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature Range:\u003c\/strong\u003e Can operate in temperatures from 0 to +55 °C, making it suitable for various industrial conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEasy Installation:\u003c\/strong\u003e Can be mounted on TH35-15 (35 x 15 mm) or TH35-7.5 (35 x 7.5 mm) DIN rails according to IEC 60715.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e PLC-AC31-90\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Name:\u003c\/strong\u003e Distributed Automation I\/O\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrimary Voltage:\u003c\/strong\u003e 24V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Digital Inputs:\u003c\/strong\u003e 32\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFieldbus Interface Type:\u003c\/strong\u003e CS31 Slave\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSerial Port Type:\u003c\/strong\u003e RS-485, CS31\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Cross-Section:\u003c\/strong\u003e 0.08 ... 1.5 mm²\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDegree of Protection:\u003c\/strong\u003e IP20\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Operating Altitude:\u003c\/strong\u003e 2000 m\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient Air Temperature (Operation):\u003c\/strong\u003e 0 ... +55 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient Air Temperature (Storage):\u003c\/strong\u003e -25 ... +75 °C\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eDimensions and Weight\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth:\u003c\/strong\u003e 120 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight:\u003c\/strong\u003e 140 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDepth:\u003c\/strong\u003e 85 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 0.59 kg (1.30 lbs)\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eThe ABB 07DI92 digital I\/O module combines robust features and reliable performance, making it a versatile choice for industrial automation systems. Its compact design and ease of installation further enhance its suitability for a wide range of applications.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":49079668179226,"sku":"07DI92","price":500.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/07DI92_3.jpg?v=1717325740"}],"url":"https:\/\/www.ubestplc.com\/collections\/chemical.oembed?page=73","provider":"Ubest Automation Limited","version":"1.0","type":"link"}