{"title":"Honeywell","description":"\u003cp\u003eHoneywell is a leading global provider of industrial automation solutions, with products widely used in various industries such as power, oil and gas, chemicals, water treatment, and building automation. Based on their product functions and application areas, Honeywell industrial automation modules can be classified into the following categories:\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eExperion PKS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eExperion PKS is Honeywell's flagship process control system (PCS) designed for large, complex process control applications. It offers powerful functionality and scalability to meet the needs of various industries.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.ubestplc.com\/collections\/honeywell-experion-pks-c200\"\u003e\u003cstrong\u003eExperion PKS C200\u003c\/strong\u003e\u003c\/a\u003e: For medium and small process control applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.ubestplc.com\/collections\/honeywell-experion-pks-c300\"\u003e\u003cstrong\u003eExperion PKS C300\u003c\/strong\u003e\u003c\/a\u003e: For large and complex process control applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.ubestplc.com\/collections\/honeywell-fcs\"\u003e\u003cstrong\u003eFSC (Field Service Controller)\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003eFSC is Honeywell's field controller for small and distributed process control applications, providing an economical and easy-to-use solution.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.ubestplc.com\/collections\/honeywell-fta\"\u003e\u003cstrong\u003eFTA (Fault Tolerant Architecture)\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003eFTA is Honeywell's fault-tolerant system designed to ensure the reliability of critical process control applications. It provides redundant hardware and software to prevent system crashes caused by single points of failure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.ubestplc.com\/collections\/honeywell-ucn\"\u003e\u003cstrong\u003eUCN (Universal Control Network)\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003eUCN is Honeywell's fieldbus for connecting field devices and controllers, offering high-speed and reliable data transmission.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.ubestplc.com\/collections\/honeywell-sensor\"\u003e\u003cstrong\u003eSensors\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003eHoneywell offers a wide variety of sensors for measuring various physical parameters such as pressure, temperature, flow, and level.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.ubestplc.com\/collections\/honeywell-other-series\"\u003e\u003cstrong\u003eOther Series\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003eHoneywell also provides other series of industrial automation modules, including safety modules, diagnostic modules, and communication modules.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003c!----\u003e","products":[{"product_id":"tk-iah161-honeywell-analog-input-module","title":"TK-IAH161 Honeywell Analog Input Module","description":"\u003cp\u003e\u003cstrong\u003eTK-IAH161 Parameter Specification\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eNumber of Points\u003c\/strong\u003e\u003cbr\u003e16 channels\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eInput Voltage Range (Voltage)\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e±10.25 volts\u003c\/li\u003e\n\u003cli\u003e0 to 10.25 volts\u003c\/li\u003e\n\u003cli\u003e0 to 5.125 volts\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eInput Current Range (Current)\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e0 to 20.5 mA (internal 250 Ω resistor)\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eVoltage Resolution\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e±10.5 volt range: 320 μV\u003c\/li\u003e\n\u003cli\u003e0 to 10.5 volt range: 160 μV\u003c\/li\u003e\n\u003cli\u003e0 to 5 volt range: 80 μV\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eCurrent Resolution\u003c\/strong\u003e\u003cbr\u003e16 bits across each range shown below\u003c\/p\u003e\u003cul\u003e\u003cli\u003e320 nA\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eModule Publish Rate\u003c\/strong\u003e\u003cbr\u003e250 msec\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eInput Impedance\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eVoltage: Greater than 1.0 MΩ\u003c\/li\u003e\n\u003cli\u003eCurrent: 249 Ω nominal\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eOpen Circuit Detection\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003eTypical OC Detection Time: Less than 5 seconds\n\u003cul\u003e\n\u003cli\u003eVoltage:\n\u003cul\u003e\n\u003cli\u003eEven channels: Positive Full scale reading\u003c\/li\u003e\n\u003cli\u003eOdd channels: Negative Full scale reading\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eCurrent:\n\u003cul\u003e\u003cli\u003eNegative Full scale reading\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eNormal Mode Noise Rejection\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003eGreater than 33 dB @ 50 Hz\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eCommon Mode Rejection\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eGreater than 60 dB @ 60 Hz\u003c\/li\u003e\n\u003cli\u003e100 dB @ 50\/60 Hz\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eChannel Bandwidth\u003c\/strong\u003e\u003cbr\u003e20 Hz (-3dB)\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCalibrated Accuracy @ 25°C\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eVoltage: Better than 0.05% of range\u003c\/li\u003e\n\u003cli\u003eCurrent: Better than 0.15% of range including sense resistor\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eRFI Immunity\u003c\/strong\u003e\u003cbr\u003eError of less than 2.0% of range at 10 V\/m, 27 to 1000 MHz\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOvervoltage Capability\u003c\/strong\u003e\u003cbr\u003eContinuous at room temperature (both)\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eVoltage: 30 VDC\u003c\/li\u003e\n\u003cli\u003eCurrent: 8 VDC\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":49003026514202,"sku":"TK-IAH161","price":650.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/TK-IAH161_1.jpg?v=1717155147"},{"product_id":"honeywell-cc-paoh01-hart-analog-output-module","title":"Honeywell CC-PAOH01 HART Analog Output Module","description":"\u003cp\u003e\u003cstrong\u003eHoneywell CC-PAOH01 HART Analog Output Module\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e The Honeywell CC-PAOH01 is a HART analog output module designed for use in industrial automation and process control systems. This module is part of Honeywell's Experion Series-C I\/O system and is used to provide precise and reliable analog output signals to various field devices such as actuators, valves, and other control elements.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e16-Channel Output:\u003c\/strong\u003e The module supports 16 independent analog output channels, enabling simultaneous control of multiple process variables.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Accuracy:\u003c\/strong\u003e Delivers reliable 24VDC analog signals with high precision, ensuring accurate process control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHART Protocol:\u003c\/strong\u003e Integrates HART (Highway Addressable Remote Transducer) communication for real-time diagnostics and remote configuration, enhancing maintenance and troubleshooting capabilities.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExtensive Diagnostics:\u003c\/strong\u003e Equipped with extensive self-diagnostics to monitor and report the health status of the module, reducing downtime and maintenance efforts.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptional Redundancy:\u003c\/strong\u003e Supports redundancy to enhance reliability and ensure continuous operation in critical applications.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Range:\u003c\/strong\u003e 4-20mA with loop current monitoring\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannel Current:\u003c\/strong\u003e Up to 460mA per channel\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication Protocol:\u003c\/strong\u003e HART\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Dimensions:\u003c\/strong\u003e 263 mm x 58 mm x 28 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 540 g (shipping weight 2kg)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Specifications:\u003c\/strong\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -40 to 70°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e -40 to 85°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity:\u003c\/strong\u003e 5 to 95% non-condensing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertifications:\u003c\/strong\u003e CE, RoHS\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e The CC-PAOH01 module is used in a variety of industrial applications where precise control of analog outputs is required. Common applications include chemical processing, oil and gas, power generation, and manufacturing processes that rely on accurate actuation and control of field devices.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":49060169744666,"sku":"CC-PAOH01","price":700.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/CC-PAIN0151410069-175.jpg?v=1717154398"},{"product_id":"honeywell-cc-pdil01-digital-input-24v-module","title":"Honeywell CC-PDIL01 Digital Input 24V Module","description":"\u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e The Honeywell CC-PDIL01 is a digital input module designed for use in industrial automation and process control systems. It is a part of Honeywell's Experion Series C I\/O system, which integrates seamlessly with the C300 controller to provide reliable and accurate monitoring of digital signals from various field devices such as switches and sensors.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e32 Channels:\u003c\/strong\u003e Supports 32 digital input channels, allowing for extensive monitoring and control capabilities.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Accuracy:\u003c\/strong\u003e Offers a high accuracy of ±0.1% of full scale, ensuring precise signal processing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWide Input Range:\u003c\/strong\u003e Can handle input voltages ranging from 0 to 30 VDC, making it versatile for different applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Reliability:\u003c\/strong\u003e Designed for high reliability and long service life, resistant to dust, moisture, and vibration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact Design:\u003c\/strong\u003e Features a compact design that facilitates easy integration and installation within control cabinets.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Type:\u003c\/strong\u003e Digital (dry contact)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Range:\u003c\/strong\u003e 0 to 30 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Impedance:\u003c\/strong\u003e \u0026gt;10 MΩ\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy:\u003c\/strong\u003e ±0.1% of full scale\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply:\u003c\/strong\u003e 24 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Specifications:\u003c\/strong\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e 0 to 60°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e -40 to 85°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity:\u003c\/strong\u003e 5 to 95% non-condensing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 263 mm x 58 mm x 28 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 1 kg (shipping weight approximately 2 kg)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertifications:\u003c\/strong\u003e CE, RoHS\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cspan\u003e The CC-PDIL01 module is ideal for use in various industrial environments where monitoring and processing of digital signals are required. Typical applications include monitoring of switches, sensors, and other discrete devices in manufacturing plants, power generation facilities, and chemical processing plants.\u003c\/span\u003e\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":49060220272922,"sku":"CC-PDIL01","price":700.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/8C-PDILA1_4.jpg?v=1717154584"},{"product_id":"cc-paih02-honeywell-hart-analog-input-module","title":"CC-PAIH02 Honeywell HART Analog Input Module","description":"\u003cp\u003e\u003cstrong\u003eHoneywell HART Analog Input Module CC-PAIH02\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e The Honeywell CC-PAIH02 is a high-level analog input module designed to integrate with Honeywell's Experion Series-C I\/O system. It supports HART communication, allowing for the transmission of digital information alongside the analog signal, which is essential for configuring and monitoring smart field devices.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e16 High-Level Input Channels:\u003c\/strong\u003e Accommodates up to 16 analog input channels, facilitating the connection of multiple transmitters and sensors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHART Communication:\u003c\/strong\u003e Enables real-time diagnostics and remote configuration of HART-enabled devices, improving maintenance efficiency and system monitoring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNon-Incendive Field Power:\u003c\/strong\u003e Suitable for hazardous environments, providing safe power supply for field instruments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eComprehensive Self-Diagnostics:\u003c\/strong\u003e Advanced diagnostic capabilities to monitor module health and identify potential issues, ensuring high reliability.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptional Redundancy:\u003c\/strong\u003e Supports redundant configurations to enhance system reliability and availability.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInnovative Design:\u003c\/strong\u003e Features vertical mounting and detachable terminals for efficient installation and effective heat management within control cabinets.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Type:\u003c\/strong\u003e Current (2-wire or self-powered transmitters)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Range:\u003c\/strong\u003e 4-20 mA (through 200 Ω)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResolution:\u003c\/strong\u003e 16-bit A\/D converter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy:\u003c\/strong\u003e ± 0.075% of full-scale (at 23.5°C ± 2°C)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommon Mode Rejection Ratio:\u003c\/strong\u003e 70 dB\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNormal Mode Rejection Ratio:\u003c\/strong\u003e 19 dB\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Requirements:\u003c\/strong\u003e 24 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature Range:\u003c\/strong\u003e 0 to 60°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 263 mm x 138 mm x 88 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 1 kg\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e The CC-PAIH02 module is utilized in various industrial settings, including:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcess Control:\u003c\/strong\u003e Monitoring and controlling critical process parameters in industries such as chemical, oil and gas, and power generation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial Automation:\u003c\/strong\u003e Integrating with automation systems to connect and process analog signals from a wide range of industrial sensors and actuators.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilding Automation:\u003c\/strong\u003e Used for monitoring and controlling building systems like HVAC, lighting, and security.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":49060280860954,"sku":"CC-PAIH02","price":600.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/HoneywellCC-PAIH01.jpg?v=1717158658"},{"product_id":"fc-fanwr-24r-honeywell-fan-assembly-kit","title":"FC-FANWR-24R Honeywell Fan Assembly Kit","description":"\u003cp\u003e\u003cstrong\u003eIntroduction\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eThe \u003cstrong\u003eFS-FANWR-24R\u003c\/strong\u003e is a 24 V DC fan unit comprising two fans and a PCB 07209 mounted on a plate. It features:\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eComponent Composition\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eConsists of two fans and a printed circuit board (PCB) 07209 on a mounting plate.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePower and Wiring\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eExternal 24 V DC power and readback contact wiring terminate on a 4-pole connector that slots into the fan unit.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFan Status Indication\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eElectronics generate signals to indicate fan status. A green LED illuminates next to a fan if its speed is above the minimum. If both fans exceed minimum speed, the readback contact closes.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSafety Features\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eFinger guards are installed on both sides of the fans.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eAirflow Direction\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eThe layout diagram depicts the direction of airflow, providing a bottom and side view of the fan unit.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eGeneral Type\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFS-FANWR-24R\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eApprovals\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eCE; UL; FM\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFan Details\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eMake:\u003c\/strong\u003e Papst\u003cbr\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e 4184N\/17X (ball bearing)\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFinger Guard Details\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eMake:\u003c\/strong\u003e Papst\u003cbr\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e LZ30\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePower Requirements\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage:\u003c\/strong\u003e 24 V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower:\u003c\/strong\u003e 9.5 W\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Range:\u003c\/strong\u003e 12-29 V DC\u003c\/li\u003e\n\u003cli\u003eNo reverse polarity protection\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003ePerformance\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAir Flow:\u003c\/strong\u003e 360 m³\/hr., 211.8 CFM (for the complete unit)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNoise:\u003c\/strong\u003e 52 dB (for the complete unit)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNominal Fan Speed:\u003c\/strong\u003e 3,200 RPM\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMinimum Speed:\u003c\/strong\u003e 1,500 ± 100 RPM (to close readback contact)\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eLife Cycle\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e85,000 hrs at 40°C (104°F)\u003c\/li\u003e\n\u003cli\u003e37,500 hrs at 75°C (167°F)\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eIngress Protection:\u003c\/strong\u003e IP20\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eTemperature Range:\u003c\/strong\u003e -30°C to +75°C (-22°F to +167°F)\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eReadback Contact Details\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax. Switched Voltage:\u003c\/strong\u003e 300 V DC \/ 240 V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax Switched Current:\u003c\/strong\u003e 0.5 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax. Switched Power:\u003c\/strong\u003e 10 W\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector:\u003c\/strong\u003e\u003cul\u003e\n\u003cli\u003eWire stripping length: 7 mm\u003c\/li\u003e\n\u003cli\u003eTightening torque: 0.4-0.5 Nm\u003c\/li\u003e\n\u003cli\u003eType of screwdriver: SD 0.6 X 3.5 -DIN 5264\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003ePhysical Dimensions\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e391x142x51 mm (LxWxD)\u003c\/li\u003e\n\u003cli\u003e15.4x5.59x2.01 in (LxWxD)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 1.7 kg\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":49060679844122,"sku":"FC-FANWR-24R","price":900.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/FC-FANWR-24R--7.jpg?v=1717307932"},{"product_id":"honeywell-fc-mcar-01-sm-rio-36-inch-carrier","title":"Honeywell FC-MCAR-01 SM RIO 36 inch Carrier","description":"\u003cp\u003e\u003cstrong\u003eIntroduction\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eThe \u003cstrong\u003eMCAR-01\u003c\/strong\u003e is a carrier that can be screwed onto any flat surface. It can accommodate one IOTA-R24 assembly. Below are its features and technical specifications:\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eComponent Composition\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eA metal profile\u003c\/li\u003e\n\u003cli\u003eA plastic cover plate\u003c\/li\u003e\n\u003cli\u003eA ground rail with 16 ground connection screws\u003c\/li\u003e\n\u003cli\u003eTwo power rails with M5 holes (+24V and 0V)\u003c\/li\u003e\n\u003cli\u003eFour mounting holes (6.35 mm diameter)\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGeneral Type number:\u003c\/strong\u003e FC-MCAR-01\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating temperature:\u003c\/strong\u003e -40 to +70°C (-40 to +158°F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage temperature:\u003c\/strong\u003e -40 to +85°C (-40 to +185°F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRelative humidity:\u003c\/strong\u003e 10 to 95% (non-condensing)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePollution:\u003c\/strong\u003e Pollution degree 2 or better\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals:\u003c\/strong\u003e CE; UL\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage:\u003c\/strong\u003e 24 V DC, range -15% to +30%\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupply current:\u003c\/strong\u003e none\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupply rail current:\u003c\/strong\u003e maximum 40 A\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eConnections\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e24V supply:\u003c\/strong\u003e 2 x M5\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGround:\u003c\/strong\u003e 16 x M5\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003ePhysical Data\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (H x W x D):\u003c\/strong\u003e 32 x 145.6 x 478 mm, or 2.52 x 5.73 x 18.8 in\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 1.1 kg or 2.4 lbs\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":49060702060826,"sku":"FC-MCAR-01","price":700.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/FC-TRO-0824_1.jpg?v=1717237015"},{"product_id":"fc-tdol-07120-honeywell-digital-output-module","title":"FC-TDOL-07120 Honeywell Digital Output Module","description":"\u003cp\u003e\u003cstrong\u003eIntroduction\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eThe \u003cstrong\u003eTDOL-07120 Field Termination Assembly Module\u003c\/strong\u003e serves as an interface for field loads requiring 120Vac or 120Vdc line-monitored digital outputs. It features 7 fused relay contact outputs with a maximum load of 240VA or 150W each.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eMain Functions and Usage\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eConnects to SDO-0824 output module and SDI-1624 input module via system interconnection cables.\u003c\/li\u003e\n\u003cli\u003eControls 7 output relays through channels 1 to 7 of the SDO-0824, with LED indication of relay states.\u003c\/li\u003e\n\u003cli\u003eLine-monitoring circuits on each output channel, controlled by channel 8 of the SDO-0824 and wired to channels 1 to 15 of the SDI-1624.\u003c\/li\u003e\n\u003cli\u003eDrives outputs and processes line monitoring results with special application logic.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eType Numbers:\u003c\/strong\u003e FS-TDOL-07120, FC-TDOL-07120\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals:\u003c\/strong\u003e CE, UL, CSA, TUV\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Channels:\u003c\/strong\u003e 7\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax. Output Current:\u003c\/strong\u003e 2A (at 120V AC)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Load:\u003c\/strong\u003e Resistive or inductive up to 240VA\/150W\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Supply Voltage:\u003c\/strong\u003e 120V AC or 120V DC +\/- 20%\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFuse Rating:\u003c\/strong\u003e 2A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax Switched Power:\u003c\/strong\u003e 1250VA \/ 60 Watts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExpected Life:\u003c\/strong\u003e 100,000 electrical switch operations, 30,000,000 mechanical switch operations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhysical Dimensions:\u003c\/strong\u003e 240 x 109 x 71 mm (L x W x H)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":49060731289882,"sku":"FC-TDOL-07120","price":600.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/FC-TSAI-1620M_2_bafaa4ac-af41-4673-8671-853e5c430407.jpg?v=1717307191"},{"product_id":"honeywell-tk-iah061-analog-input-module-6-point-high-level","title":"Honeywell TK-IAH061 Analog Input Module 6-Point High Level","description":"\u003cp\u003e\u003cstrong\u003eSpecifications – Traditional I\/O Modules\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eTC-IAH061, TK-IAH061\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eTable 6-6 High Level Analog, 6-Input, Voltage and Current (10 V \u0026amp; 4-20 mA) Module\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eParameter Specification\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eNumber of Points\u003c\/strong\u003e 6 galvanically isolated channels\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eInput Voltage Range (Voltage)\u003c\/strong\u003e 10.50 VDC maximum\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eInput Current Range (Current)\u003c\/strong\u003e 0 to 21.0 mA (with 249Ω resistor)\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eVoltage Resolution\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003e16 bits across each range shown below\u003c\/strong\u003e\u003cul\u003e\n\u003cli\u003e±10.5 volt range: 343 μV typical (15 bits + sign)\u003c\/li\u003e\n\u003cli\u003e0 to 10.5 volt range: 171 μV typical\u003c\/li\u003e\n\u003cli\u003e0 to 5.25 volt range: 86 μV typical\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eCurrent Resolution\u003c\/strong\u003e 0.34 μA\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eInput Impedance\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage\u003c\/strong\u003e: Greater than 10 MΩ\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent\u003c\/strong\u003e: 249Ω\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eOpen Circuit Detection\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage\u003c\/strong\u003e: Upscale reading\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent\u003c\/strong\u003e: Zero scale reading\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eTypical Open Circuit Detection Time\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage\u003c\/strong\u003e: 5 seconds\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent\u003c\/strong\u003e: 1 second\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eNormal Mode Noise Rejection\u003c\/strong\u003e Greater than 60 dB @ 60 Hz\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCommon Mode Rejection\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e120 dB @ 60 Hz\u003c\/li\u003e\n\u003cli\u003e100 dB @ 50 Hz\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eChannel Bandwidth\u003c\/strong\u003e 0 to 15 Hz (-3 dB)\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSettling Time to 5% of Full Scale\u003c\/strong\u003e Less than 80 milliseconds\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCalibrated Accuracy @ 25°C\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage\u003c\/strong\u003e: Better than 0.1% of range\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent\u003c\/strong\u003e: Better than 0.15% of range including 0.05% sense resistor\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eModule Update Rate for All Channels\u003c\/strong\u003e 25 ms\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eRFI Immunity\u003c\/strong\u003e Error of less than 2.0% of range at 10 V\/m, 27 to 1000 MHz\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOvervoltage Capability\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage\u003c\/strong\u003e: 120 VAC\/VDC continuous at room temperature\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent\u003c\/strong\u003e: 8 VAC\/VDC with on-board current resistor\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eInput Offset Drift with Temperature\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage\u003c\/strong\u003e: 2 μV\/°C typical\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent\u003c\/strong\u003e: 8.0 μV\/°C typical\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eGain Drift with Temperature\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage\u003c\/strong\u003e: 35 ppm\/°C typical\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent\u003c\/strong\u003e: 45 ppm\/°C typical\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003ePower Dissipation\u003c\/strong\u003e 4.3 W max\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eBackplane Current\u003c\/strong\u003e See Module Power Consumption Data, page 46.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eIsolation Voltage\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannel to channel\u003c\/strong\u003e: 100% tested at 2546 VDC for 1 second\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUser to system\u003c\/strong\u003e: 100% tested at 2546 VDC for 1 second\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eConnection Terminal Blocks\u003c\/strong\u003e TC-TBNH, 20-position terminal block\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWeight :\u003c\/strong\u003e 0.25 kg\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":49070744076570,"sku":"TK-IAH061","price":700.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/TK-IAH061_1.jpg?v=1717242254"},{"product_id":"honeywell-tk-idd321-32-point-discrete-input-module","title":"Honeywell TK-IDD321 32-Point Discrete Input Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe TK-IDD321 is a 24 VDC, 32-Point Discrete Input Module designed for high-performance industrial automation systems. This module features 32 discrete inputs, grouped in 16 points per common, making it highly efficient for various input applications.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Input Capacity\u003c\/strong\u003e: Accommodates 32 discrete inputs, supporting a wide range of industrial input devices.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Range\u003c\/strong\u003e: Operates efficiently within a voltage range of 10-31.2 VDC at temperatures up to 60°C across all channels.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation\u003c\/strong\u003e: Ensures safety with 1500 VDC isolation tested between channels and from user to system.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Inputs\u003c\/strong\u003e: 32 (16 points\/common)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOn-stage Voltage Range\u003c\/strong\u003e: 10-31.2 VDC @ 60°C all channels\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNominal Input Voltage\u003c\/strong\u003e: 24 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOn-State Current (Minimum)\u003c\/strong\u003e: 2 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOff-State Voltage (Maximum)\u003c\/strong\u003e: 5 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOff-State Current (Maximum)\u003c\/strong\u003e: 1.5 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation Voltage\u003c\/strong\u003e:\n\u003cul\u003e\n\u003cli\u003eChannel to channel: 1500 VDC for 1 second\u003c\/li\u003e\n\u003cli\u003eUser to system: 1500 VDC for 1 second\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInput Delay Time\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOff to On\u003c\/strong\u003e:\n\u003cul\u003e\n\u003cli\u003eHardware delay: 1 ms maximum plus filter time\u003c\/li\u003e\n\u003cli\u003eProgrammable filter: 0 ms, 1 ms, or 2 ms\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOn to Off\u003c\/strong\u003e:\n\u003cul\u003e\n\u003cli\u003eHardware delay: 1 ms maximum plus filter time\u003c\/li\u003e\n\u003cli\u003eProgrammable filter: 0 ms, 1 ms, 2 ms, 9 ms, or 18 ms\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003ePower Dissipation\u003c\/h3\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eMaximum Power Dissipation\u003c\/strong\u003e: 6.1 W\u003c\/li\u003e\u003c\/ul\u003e\u003ch3\u003eShort\/Inrush Current\u003c\/h3\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003ePeak Short\/Inrush Current\u003c\/strong\u003e: 250 mA (decaying to \u0026lt;37% in 22 ms, without activation)\u003c\/li\u003e\u003c\/ul\u003e\u003ch3\u003eInput Compatibility\u003c\/h3\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eCompliance\u003c\/strong\u003e: IEC Type 1+\u003c\/li\u003e\u003c\/ul\u003e\u003ch3\u003eBackplane Current\u003c\/h3\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eReference\u003c\/strong\u003e: See Module Power Consumption Data, page 46.\u003c\/li\u003e\u003c\/ul\u003e\u003ch3\u003eConnection\u003c\/h3\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eTerminal Blocks\u003c\/strong\u003e: TC-TBCH, 36-position terminal block\u003c\/li\u003e\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":49070777598234,"sku":"TK-IDD321","price":900.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/TK-IOLI0151403427-17551309283-600_4.jpg?v=1717236294"},{"product_id":"honeywell-tc-odd321-experion-dc-output-module","title":"Honeywell TC-ODD321 Experion DC Output Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe 24 VDC, 32-Point Discrete Output Module is engineered for reliable performance in industrial automation systems. It offers a high-density output configuration with 32 outputs, organized in groups of 16 points per common, and ensures robust and efficient control for various output devices.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Output Capacity\u003c\/strong\u003e: Supports 32 discrete outputs, divided into 16 points per common, ideal for complex automation needs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWide Output Voltage Range\u003c\/strong\u003e: Operates within a 10-31.2 VDC range at 50°C with linear derating, ensuring flexibility and reliability in diverse conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfigurable Fault and Program States\u003c\/strong\u003e: Allows setting fault states and program mode states to Hold Last State, ON, or OFF for each point, providing enhanced control and safety.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Outputs\u003c\/strong\u003e: 32 (16 points\/common)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Voltage Range\u003c\/strong\u003e:\n\u003cul\u003e\n\u003cli\u003e10-31.2 VDC @ 50°C (Linear derating)\u003c\/li\u003e\n\u003cli\u003e10-28 VDC @ 60°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Current Rating\u003c\/strong\u003e:\n\u003cul\u003e\n\u003cli\u003ePer Point: 0.5A maximum @ 50°C (Linear derating), 0.35A maximum @ 60°C\u003c\/li\u003e\n\u003cli\u003ePer Module: 16A maximum @ 50°C (Linear derating), 10A maximum @ 60°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSurge Current\u003c\/strong\u003e: 1A for 10ms each, repeatable every 2s @ 60°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlash On Time\u003c\/strong\u003e: 100 µsec target, 150 µsec max\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOn-State Current Load (Minimum)\u003c\/strong\u003e: 3.0 mA per output\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOn-State Voltage Drop (Maximum)\u003c\/strong\u003e:\n\u003cul\u003e\n\u003cli\u003e1 VDC @ rated current per point\u003c\/li\u003e\n\u003cli\u003e3 VDC for IEC 1131-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOff-State Leakage Current (Maximum)\u003c\/strong\u003e:\n\u003cul\u003e\n\u003cli\u003e0.5 mA per point\u003c\/li\u003e\n\u003cli\u003e1 mA per point for IEC 1131-2 for 0.25 A output\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eConfigurable Settings\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFault States per Point\u003c\/strong\u003e: Configurable to Hold Last State, ON, or OFF (default OFF)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStates in Program Mode per Point\u003c\/strong\u003e: Configurable to Hold Last State, ON, or OFF (default OFF)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eProtection and Safety\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFusing\u003c\/strong\u003e: Not protected. It is recommended to use Fused IFM to protect outputs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReverse Polarity Protection\u003c\/strong\u003e: None. Incorrect wiring may damage outputs.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eOutput Delay Time\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOff to On\u003c\/strong\u003e: 1.0 ms maximum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOn to Off\u003c\/strong\u003e: 1.0 ms maximum\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003ePower Dissipation\u003c\/h3\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eMaximum Power Dissipation\u003c\/strong\u003e: 6.1 W\u003c\/li\u003e\u003c\/ul\u003e\u003ch3\u003eBackplane Current\u003c\/h3\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eReference\u003c\/strong\u003e: See Module Power Consumption Data, page 46.\u003c\/li\u003e\u003c\/ul\u003e\u003ch3\u003eIsolation Voltage\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGroup to Group\u003c\/strong\u003e: 100% tested at 2546V DC for 1 second (250V AC maximum continuous voltage between groups)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUser to System\u003c\/strong\u003e: 100% tested at 2546V DC for 1 second\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eConnection\u003c\/h3\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eTerminal Blocks\u003c\/strong\u003e: TC-TBCH, 36-position terminal block\u003c\/li\u003e\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":49070810136858,"sku":"TC-ODD321","price":600.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/TC-ODD321_1.jpg?v=1717235644"},{"product_id":"honeywell-tc-fpcxx2-ac-power-supply-module","title":"Honeywell TC-FPCXX2 AC Power Supply Module","description":"\u003cp\u003e\u003cstrong\u003ePower Supply Specifications\u003c\/strong\u003e\u003c\/p\u003e\u003ch3\u003eModel\u003c\/h3\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eUncoated\u003c\/strong\u003e: TC-FPCXX2\u003c\/li\u003e\u003c\/ul\u003e\u003ch3\u003eInput Specifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Voltage Range\u003c\/strong\u003e:\n\u003cul\u003e\u003cli\u003e85-132 VAC or 170-265 VAC (selectable)\u003cbr\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Power\u003c\/strong\u003e:\n\u003cul\u003e\u003cli\u003e150 VA, 92 W\u003cbr\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Inrush Current\u003c\/strong\u003e:\n\u003cul\u003e\u003cli\u003e15 A\u003cbr\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency Range\u003c\/strong\u003e:\n\u003cul\u003e\u003cli\u003e47-63 Hz\u003cbr\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eOutput Specifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotal Power Output Maximum\u003c\/strong\u003e: 70 W @ 60°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane Output Current, Maximum\u003c\/strong\u003e:\n\u003cul\u003e\n\u003cli\u003e1.5 A @ 1.2 V\u003c\/li\u003e\n\u003cli\u003e4 A @ 3.3 V\u003c\/li\u003e\n\u003cli\u003e10 A @ 5.1 V\u003c\/li\u003e\n\u003cli\u003e2.8 A @ 24.0 V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eProtection\u003c\/h3\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eFuse Protection\u003c\/strong\u003e: Non-replaceable fuse is soldered in place. This fuse is intended to guard against fire hazards due to short circuit conditions and may not protect the power supply from damage under overload conditions.\u003c\/li\u003e\u003c\/ul\u003e\u003ch3\u003eWiring\u003c\/h3\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eWire Gauge\u003c\/strong\u003e: #14 AWG (1.4 mm)\u003c\/li\u003e\u003c\/ul\u003e\u003ch3\u003ePhysical Dimensions\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (L x D x H)\u003c\/strong\u003e: 11.2 x 14.5 x 14.0 cm (4.41 x 5.71 x 5.51 in)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight\u003c\/strong\u003e: Approximate 1.1 kg (2.5 lb.)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation\u003c\/h3\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eLocation\u003c\/strong\u003e: Left side of chassis (does not consume a slot)\u003c\/li\u003e\u003c\/ul\u003e\u003ch3\u003eNotes\u003c\/h3\u003e\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Voltage Drop\u003c\/strong\u003e: Input may drop to 16 V for a maximum of 2 minutes each hour for motor starting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEarlier Models Ratings\u003c\/strong\u003e:\n\u003cul\u003e\n\u003cli\u003eTC-FPCXX1: 55 W @ 60°C; 70 W @ 45°C\u003c\/li\u003e\n\u003cli\u003eTC-FPDXX1: 50 W @ 60°C; 70 W @ 40°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Output Limitation\u003c\/strong\u003e: The combination of all output power (5 V backplane, 24 V backplane, 3.3 V backplane, and 1.2 V backplane) cannot exceed 70 W.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":49070831960346,"sku":"TC-FPCXX2","price":900.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/TC-FPCXX2_1__png.jpg?v=1717236181"},{"product_id":"new-fc-sdil-1608-honeywell-safety-manager-system-module","title":"New FC-SDIL-1608 Honeywell Safety Manager System Module","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\u003cp\u003eThe SDIL-1608 Safe Loop-Monitored Digital Input Module is designed to provide sixteen channels for loop-monitored loops or status signals derived from proximity switches, adhering to DIN (NAMUR) standards. This module is ideal for safety-critical applications, offering robust monitoring and diagnostic features to ensure system integrity.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Channels\u003c\/strong\u003e: Sixteen channels for loop-monitored loops or proximity switch signals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEarth Fault Monitoring\u003c\/strong\u003e: Supports monitoring of earth faults within the sixteen loops, ensuring system integrity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Compliance\u003c\/strong\u003e: Suitable for applications up to SIL 3, meeting IEC 61508 standards for safety.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOn-Board DC\/DC Converter\u003c\/strong\u003e: Supplies power for connected field devices via a common converter for all sixteen channels, ensuring reliable operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLED Indicators\u003c\/strong\u003e: Front-panel LEDs provide status indications for channels, loops, and module diagnostics, facilitating easy monitoring and troubleshooting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Conversion\u003c\/strong\u003e: Requires signal converter modules BN-1608 or BSN-1608 for converting proximity switch signals to a suitable level for the module.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eLED Indicators\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannel LEDs\u003c\/strong\u003e:\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGreen LED\u003c\/strong\u003e: Indicates channel status (ON for high, OFF for low).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRed LED\u003c\/strong\u003e: Indicates faults such as lead breakage or short circuits.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEarth LED\u003c\/strong\u003e: Indicates earth connection test status (green for OK, red for false, OFF for disabled).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStatus LED\u003c\/strong\u003e: Indicates module status (green for OK, red for faulty\/not running).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eType Numbers\u003c\/strong\u003e: FS-SDIL-1608, FC-SDIL-1608, FA-SDIL-1608, meeting international safety standards.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals\u003c\/strong\u003e: CE, TUV, UL, CSA, FM, ensuring regulatory compliance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpace Requirements\u003c\/strong\u003e: 4 TE, 3 HE (= 4 HP, 3U), offering a compact form factor for efficient installation.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003ePower Requirements\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e5V DC\u003c\/strong\u003e: 160 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e24V DC\u003c\/strong\u003e: 110 mA\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInput Specifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Channels\u003c\/strong\u003e: 16\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Type\u003c\/strong\u003e: According to DIN (NAMUR) standards\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitch Level\u003c\/strong\u003e: 1.4-1.9 mA with 0.2 mA ± 0.05 mA hysteresis\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Filter\u003c\/strong\u003e: First-order, low pass with 100 Hz cutoff\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Load Capacitance\u003c\/strong\u003e: 100 nF\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEarth Connection Monitor\u003c\/strong\u003e: Ensures proper earth connection with a test current of typically 0.5 mA and output voltage of typically 0.5 V DC.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":49070867022106,"sku":"FC-SDIL-1608","price":600.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/FC-SDI-1624_2.jpg?v=1717234290"},{"product_id":"honeywell-fc-tsai-1620m-safety-analog-input-module","title":"Honeywell FC-TSAI-1620M Safety Analog Input Module","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\u003cp\u003eThe TSAI-1620m is a Safe 0-20 mA and 4-20 mA Analog Input Field Termination Assembly (FTA) module. It serves as a crucial interface between field components, such as sensors, and the high-density analog input module SAI-1620m in Safety Manager systems. This module is specifically designed for use in Class I, Division 2 hazardous locations, ensuring safe and reliable operation in challenging environments.\u003c\/p\u003e\u003ch3\u003eMain Functions\u003c\/h3\u003e\u003cp\u003eThe TSAI-1620m module performs three primary functions:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Conversion\u003c\/strong\u003e: Converts 0(4)-20 mA DC field signals to the signal levels required by the SAI-1620m module.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply Distribution\u003c\/strong\u003e: Distributes power to each transmitter with voltage-current limitation, ensuring compliance with hazardous area standards.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Monitoring\u003c\/strong\u003e: Monitors the external power connected to the FTA module.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ch4\u003eGeneral\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eType Numbers\u003c\/strong\u003e: FS-TSAI-1620m, FC-TSAI-1620m\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals\u003c\/strong\u003e: CE, TUV, UL, CSA, FM\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eInput\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Channels\u003c\/strong\u003e: 16 (2 groups of 8 channels with common 0 V)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Requirements\u003c\/strong\u003e: 30 V DC external, 3 mA (without input loop loads)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Current\u003c\/strong\u003e: 0-25 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Resistance\u003c\/strong\u003e: 250 Ω (± 1%)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eOutput\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTo Passive Transmitters (Vext)\u003c\/strong\u003e:\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Resistance\u003c\/strong\u003e: 270 Ω (± 5%)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIgniting Current per Channel\u003c\/strong\u003e: \u0026lt; 120 mA at 30 V DC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTo SAI-1620m Module\u003c\/strong\u003e:\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Voltage\u003c\/strong\u003e: 0-4 V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy\u003c\/strong\u003e: 0.10%\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eFuse\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRating\u003c\/strong\u003e: 315 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions\u003c\/strong\u003e: 5x20 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Rating AC\u003c\/strong\u003e: 125 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Output Current per Fuse\u003c\/strong\u003e: 220 mA\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003ePhysical\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Dimensions\u003c\/strong\u003e: 210 × 70 × 60 mm (8.26 × 2.76 × 2.36 in)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDIN EN Rails\u003c\/strong\u003e: TS32 \/ TS35 × 7.5\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUsed Rail Length\u003c\/strong\u003e: 211 mm (8.30 in)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 0.43kg\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eTermination\u003c\/h4\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eScrew Terminals\u003c\/strong\u003e:\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax. Wire Diameter\u003c\/strong\u003e: 2.5 mm² (AWG 14)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStrip Length\u003c\/strong\u003e: 7 mm (0.28 in)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTightening Torque\u003c\/strong\u003e: 0.5 Nm (0.37 ft-lb)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":49070888616218,"sku":"FC-TSAI-1620M","price":600.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/FC-TSAI-1620M_1_8f0aa3c5-393e-4830-a24c-60927247b348.jpg?v=1717238175"},{"product_id":"mc-paih03-honeywell-high-level-analog-input-module","title":"MC-PAIH03 Honeywell High Level Analog Input Module","description":"\u003ch2\u003eHoneywell MC-PAIH03 Analog Processor - Precision 16-Channel Industrial Input\u003c\/h2\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: Honeywell | \u003cstrong\u003eModel\u003c\/strong\u003e: MC-PAIH03 (51304754-150)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Types\u003c\/strong\u003e: 0-5V, 1-5V, 0.4-2V, 4-20mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy\u003c\/strong\u003e: ±0.075% FS (room temp)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResolution\u003c\/strong\u003e: 16-bit A\/D converter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eScan Rate\u003c\/strong\u003e: 4 samples\/sec per channel\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Protection\u003c\/strong\u003e: ±30V damage-proof\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower\u003c\/strong\u003e: 24V DC | \u003cstrong\u003eWeight\u003c\/strong\u003e: 0.6kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemp Range\u003c\/strong\u003e: 0°C to 50°C operational\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eKey Advantages\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #1976d2;\"\u003e60dB crosstalk rejection\u003c\/strong\u003e between channels\u003c\/li\u003e\n\u003cli\u003e10MΩ input impedance for minimal loading\u003c\/li\u003e\n\u003cli\u003eANSI\/IEEE surge protection standard\u003c\/li\u003e\n\u003cli\u003eDifferential inputs reduce noise errors\u003c\/li\u003e\n\u003cli\u003eCompact design saves control panel space\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eEasy Installation\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eDIN-rail mounting (35mm standard)\u003c\/li\u003e\n\u003cli\u003eTool-free spring terminals\u003c\/li\u003e\n\u003cli\u003eHot-swappable during operation\u003c\/li\u003e\n\u003cli\u003ePre-wired FTA compatibility\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eMaintenance \u0026amp; Diagnostics\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eContinuous self-diagnostics\u003c\/li\u003e\n\u003cli\u003eLED status indicators\u003c\/li\u003e\n\u003cli\u003eAuto-calibration function\u003c\/li\u003e\n\u003cli\u003eMTBF: 150,000+ hours\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSystem Compatibility\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFTA Series: MU-TAIH02, TAIH12, TAIH52, etc.\u003c\/li\u003e\n\u003cli\u003eHoneywell Experion PKS\u003c\/li\u003e\n\u003cli\u003eModbus RTU\/TCP protocols\u003c\/li\u003e\n\u003cli\u003eLegacy DCS systems\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eCertifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eCE, UL, cULus\u003c\/li\u003e\n\u003cli\u003eIEC 61131-2 compliant\u003c\/li\u003e\n\u003cli\u003eRoHS compliant\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003ePackage Contents\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eMC-PAIH03 processor module\u003c\/li\u003e\n\u003cli\u003eInstallation guide\u003c\/li\u003e\n\u003cli\u003eDIN rail clip\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e12-month warranty\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eGlobal Shipping\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFedEx International Priority\u003c\/li\u003e\n\u003cli\u003eUPS Worldwide Express\u003c\/li\u003e\n\u003cli\u003eDHL Express 12:00\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Minimum detectable signal change?\u003c\/strong\u003e\u003cbr\u003eA: 0.0015% full scale resolution\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Maximum wire length?\u003c\/strong\u003e\u003cbr\u003eA: 100m shielded twisted pair\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Humidity tolerance?\u003c\/strong\u003e\u003cbr\u003eA: 5-95% non-condensing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Vibration resistance?\u003c\/strong\u003e\u003cbr\u003eA: 2g @ 10-500Hz (IEC 60068)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Software required?\u003c\/strong\u003e\u003cbr\u003eA: None - operates standalone\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":49074723160346,"sku":"MC-PAIH03","price":850.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/80363975-150MC-PDOY22_3.jpg?v=1717241896"},{"product_id":"51400955-100-honeywell-pni-processor-control-board","title":"51400955-100 Honeywell PNI Processor Control Board","description":"\u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e The Honeywell 51400955-100 Process Network Interface Board serves as a vital component for processor control within Distributed Control Systems (DCS). With its multi input\/output capabilities, this board is engineered to facilitate seamless communication within the process network interface. Suitable for panel mount installations, it ensures efficient operation in various industrial settings.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFull Description:\u003c\/strong\u003e The Honeywell 51400955-100 Process Network Interface Board, also referred to as the PNI Board Assembly, is meticulously designed to streamline communication within DCS environments, particularly compatible with TDC3000 systems. Equipped with EPNI\/NGI functionalities, this board offers robust performance and reliability in process control applications.\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eInstallation Instructions:\u003c\/strong\u003e\u003c\/p\u003e\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eAssembling I\/O Boards:\u003c\/strong\u003e Install (6) I\/O boards onto the rear chassis, ensuring connectors remain undamaged, and securely fasten board retainers. Verify that the I\/O boards align with the primary boards. Reconnect cables to replaced boards, if applicable.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInserting Power Supply:\u003c\/strong\u003e Place the power supply (4) into the chassis and secure retainers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstalling Fan Assembly:\u003c\/strong\u003e Insert the fan assembly (5) into the chassis and securely fasten bail-headed screws.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInserting Boards:\u003c\/strong\u003e Install (2) boards into the chassis and secure retainers. Reconnect ribbon cables to replaced boards, if necessary.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAssembling Front Panel:\u003c\/strong\u003e Attach the front panel (1) to the chassis and secure it with quarter-turn fasteners.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":49074795577626,"sku":"51400955-100","price":850.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/51400955-100_5.jpg?v=1717308525"},{"product_id":"lg1093aa44-honeywell-lg-uv-flame-detector","title":"LG1093AA44 Honeywell LG UV Flame Detector","description":"\u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e The Honeywell LG\/EG flame monitoring system is adept at detecting UV radiation emitted by hydrocarbon flames, providing clear indications of flame or no-flame conditions. This system boasts a track record of over 35 years of reliable performance on General Electric (and GE licensee) gas turbines.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eUtilizes a Geiger Mueller-type sensor phototube to detect UV radiation in the 180-260nm range, making it solar-blind and tolerant to black body radiation.\u003c\/li\u003e\n\u003cli\u003eOffers a shelf-life of two years and a mean time between failures (MTBF) of 10,000 hours, with over one billion operating hours.\u003c\/li\u003e\n\u003cli\u003eSuitable for gas turbines used in power generation and compressors, with a temperature range of -40 to 176°C.\u003c\/li\u003e\n\u003cli\u003eHardware outputs available for EG1033 amplifier modules, including transistor open collector (EG1033AA) and relay contacts (EG1033AB and EG1033AC).\u003c\/li\u003e\n\u003cli\u003eFast Flame Present Response Time of 0.1 sec typical, and Flame Loss Response Time of 0.2 sec max.\u003c\/li\u003e\n\u003cli\u003eAmplifiers support multiple voltage requirements: 28 Vdc, 20-35 Vdc, and 115 Vac.\u003c\/li\u003e\n\u003cli\u003eOperates at distances of up to 330m (1000ft) between sensor and amplifier.\u003c\/li\u003e\n\u003cli\u003eQualified component on General Electric turbines.\u003c\/li\u003e\n\u003cli\u003eHolds European Directive CE mark for EMC 89\/336\/EEC, LVD 73\/23\/EEC, and ATEX Explosive Atmosphere 94\/9\/EC (EEx d IIA T3 or EEX d IIC T3, Zone 1 and 2).\u003c\/li\u003e\n\u003cli\u003eApproved by Factory Mutual for explosive atmospheres (Class I, Div 1 and 2, Groups B, C, and D).\u003c\/li\u003e\n\u003cli\u003eNote: May not perform as expected on GE\/NP DLE gas turbines (Low-NOx) without pre-selected LG1093 models not available via Honeywell.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eFlame Sensor Details:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eMounting: 3\/4\" internal NPT\u003c\/li\u003e\n\u003cli\u003eCable Length: 16ft (4.9m)\u003c\/li\u003e\n\u003cli\u003eViewing Window: Rated for 10bar (150psi)\u003c\/li\u003e\n\u003cli\u003eSupply Voltage: Not specified\u003c\/li\u003e\n\u003cli\u003eApprovals: CE\/ATEX (EEx d IIC T3)\u003c\/li\u003e\n\u003cli\u003eShipping Weight: 3 Kg\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":49074847580442,"sku":"LG1093AA44","price":750.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/LG1093AA44_3.jpg?v=1717242783"},{"product_id":"620-0083-honeywell-processor-power-supply-module","title":"620-0083 Honeywell Processor Power Supply Module","description":"\u003cp\u003e\u003cstrong\u003eModel No. 620-0083 Processor Power Supply\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eThe \u003cstrong\u003e620-0083 Processor Power Supply\u003c\/strong\u003e is designed for use with the \u003cstrong\u003e620-06 Processor\u003c\/strong\u003e. It is intended to be installed in a full processor rack, occupying slot I. The front panel of the module features terminals labeled A (line or Ll), B (Common or L2), and a ground symbol for connecting AC power wiring.\u003c\/p\u003e\u003ch3\u003e\u003cstrong\u003eInput Power Selection\u003c\/strong\u003e\u003c\/h3\u003e\u003cp\u003eThe input power for the 620-0083 is selectable for either \u003cstrong\u003e85-132 VAC\u003c\/strong\u003e or \u003cstrong\u003e170-250 VAC\u003c\/strong\u003e. This flexibility allows the power supply to operate in various voltage environments by simply toggling a switch under the module's component cover. The unit is factory set to \u003cstrong\u003e115 VAC\u003c\/strong\u003e.\u003c\/p\u003e\u003ch3\u003e\u003cstrong\u003ePower Output\u003c\/strong\u003e\u003c\/h3\u003e\u003cp\u003eThe 620-0083 provides up to \u003cstrong\u003e15 amps of +5VDC\u003c\/strong\u003e power to the rack. Additionally, it can supply up to \u003cstrong\u003e1.16 amps of ±15 VDC\u003c\/strong\u003e power. In analog configurations, the power supply offers \u003cstrong\u003e10 amps of +5VDC\u003c\/strong\u003e and \u003cstrong\u003e1.3 amps of ±15 VDC\u003c\/strong\u003e maximum. The total output power is limited to \u003cstrong\u003e90 watts\u003c\/strong\u003e.\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\u003ch3\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/h3\u003e\u003cp\u003eThe 620-0083 has a maximum normal power consumption of \u003cstrong\u003e110VA\u003c\/strong\u003e. A cold start requires a maximum of \u003cstrong\u003e20 amps for one cycle\u003c\/strong\u003e. This specification is crucial for ensuring the power supply starts reliably under load.\u003c\/p\u003e\u003ch3\u003e\u003cstrong\u003eSafety and Indicators\u003c\/strong\u003e\u003c\/h3\u003e\u003cp\u003eThe fuse holder, accessible from the front of the module, is shipped with a \u003cstrong\u003eSlo-Blo fuse\u003c\/strong\u003e for 115 VAC. A green LED on the front panel indicates the presence of \u003cstrong\u003e5VDC\u003c\/strong\u003e power.\u003c\/p\u003e\u003ch3\u003e\u003cstrong\u003eSpecifications and Weight\u003c\/strong\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Range:\u003c\/strong\u003e 85-132 VAC or 170-250 VAC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Power:\u003c\/strong\u003e Up to 15 amps of +5VDC, 1.16 amps of ±15 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotal Output Power:\u003c\/strong\u003e 90 watts maximum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Consumption:\u003c\/strong\u003e 110VA normal, 20 amps for cold start cycle\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFactory Setting:\u003c\/strong\u003e 115 VAC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFuse:\u003c\/strong\u003e Slo-Blo for 115 VAC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLED Indicator:\u003c\/strong\u003e Green for 5VDC presence\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":49098999595290,"sku":"620-0083","price":300.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/620-0083_4.jpg?v=1717507649"},{"product_id":"honeywell-cc-pcf901-9-port-fte-control-firewall-module","title":"Honeywell CC-PCF901 9 Port FTE Control Firewall Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe \u003cstrong\u003eHoneywell CC-PCF901 Control Firewall Module\u003c\/strong\u003e is a robust and advanced device designed to enhance network security for industrial control systems. It provides efficient distribution of FTE (Fault Tolerant Ethernet) cables to multiple Series C Fieldbus Interface Modules (FIMs) and mounts on the CF9 Input\/Output Termination Assembly (IOTA). This module is critical for securing communication within Honeywell Experion PKS and Experion LX systems, ensuring a secure and reliable connection between the control system and field devices.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNetwork Security\u003c\/strong\u003e: The CC-PCF901 protects critical control systems from cyber threats such as viruses, malware, and unauthorized access. It features packet filtering, stateful inspection, and intrusion detection and prevention capabilities.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEfficient Distribution\u003c\/strong\u003e: Provides FTE distribution to in-cabinet network nodes, optimizing the connectivity and communication within the control network.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEasy Installation\u003c\/strong\u003e: The module is designed for easy installation and maintenance, fitting seamlessly into existing systems without requiring significant modifications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReal-Time Monitoring\u003c\/strong\u003e: Monitors network traffic for suspicious activity and logs all network events to ensure the integrity and security of the control system.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions\u003c\/strong\u003e: 190 mm x 69 mm x 23 mm (7.5 in x 2.7 in x 0.9 in)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight\u003c\/strong\u003e: 0.45 kg (1 lb)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Consumption\u003c\/strong\u003e: 10 W\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: -40 to 85 °C (-40 to 185 °F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e: -40 to 85 °C (-40 to 185 °F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity\u003c\/strong\u003e: 5% to 95% non-condensing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVibration\u003c\/strong\u003e: 5 g peak at 20 to 500 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShock\u003c\/strong\u003e: 30 g peak for 11 ms\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupply Rating\u003c\/strong\u003e: 0.112A @ 24VDC\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":49117671850266,"sku":"CC-PCF901","price":660.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/CC-PCF901Honeywell.jpg?v=1717677002"},{"product_id":"honeywell-cc-paix02-high-level-analog-input-module","title":"Honeywell CC-PAIX02 High Level Analog Input Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe \u003cstrong\u003eHoneywell CC-PAIX01 Analog Input Modules\u003c\/strong\u003e are essential components within Honeywell's control systems, designed to accept high-level current or voltage inputs from various transmitters and sensing devices. These modules expand the system's analog input capabilities, providing reliable and accurate data acquisition for industrial applications.\u003c\/p\u003e\u003ch3\u003eFunction\u003c\/h3\u003e\u003cp\u003eThe \u003cstrong\u003eAnalog Input Module\u003c\/strong\u003e accepts high-level current or voltage inputs from transmitters and sensing devices. It is designed to interface seamlessly with Honeywell’s Experion® Series C I\/O and C300 controllers, ensuring efficient data collection and processing.\u003c\/p\u003e\u003ch3\u003eNotable Features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eExtensive Self-Diagnostics\u003c\/strong\u003e: The module is equipped with advanced diagnostics to monitor and report operational status, ensuring reliability and ease of maintenance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptional Redundancy\u003c\/strong\u003e: Supports redundant configurations to enhance system reliability and availability.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupplies Non-Incendive Field Power\u003c\/strong\u003e: Provides non-incendive power to field devices, reducing the risk of ignition in hazardous environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFast Loop Scan\u003c\/strong\u003e: Enables rapid data collection, ensuring timely updates and accurate control.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eDetail Specifications – Analog Input\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput \/ Output Model\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eCC-PAIX02 - High-Level Analog Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIOTA Models\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eNon-Redundant: CC-TAIX01, CC-GAIX21, CC-TAID01\u0026lt;br\u0026gt;Redundant: CC-TAIX11, CC-GAIX11, CC-TAID11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eVoltage, current (2-wire or self-powered transmitters)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e16 Channels (12 Single Ended \/ 4 Differential)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommon Mode Rejection Ratio\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e70 dB (dc to 60 Hz, 500 Ω source imbalance)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommon Mode Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e-6 to +5 V peak (dc to 60 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eA\/D Converter Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e16 bits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e0 to 5 V, 1 to 5 V, 0.4 to 2 V, 4-20 mA (through 250 Ω)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNormal Mode Rejection Ratio\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e19 dB (at 60 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNormal Mode Filter Response\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eSingle-pole RC, -3 dB @ 6.5 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Normal Mode Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e± 30 Volts (differential inputs, no damage)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCrosstalk\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e-60 dB (channel-to-channel, dc to 60 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Impedance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u0026gt; 10 MΩ (voltage inputs, powered)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Scan Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e50 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHardware Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003e± 0.075% of full-scale (23.5°± 2°C)\u0026lt;br\u0026gt;± 0.15% of full-scale (0 to 60°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTransmitter Field Power Conditioning\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eIndividually Protected Current Limiting Circuits for Class 1, Div 2 non-incendive interfacing. No fusing required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":49117718380826,"sku":"CC-PAIX02","price":400.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/8c.jpg?v=1717677725"},{"product_id":"cc-paon01-honeywell-analog-output-module-51410070-175","title":"CC-PAON01 Honeywell - Analog Output Module 51410070-175","description":"\u003ch2\u003eAnalog Output – CC-PAON01\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eFunction:\u003c\/strong\u003e The Analog Output (AO) Module delivers high-level constant current to actuators and recording\/indicating devices, ensuring precise and reliable performance.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eNotable Features:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eExtensive Self-Diagnostics:\u003c\/strong\u003e Provides continuous monitoring for optimal performance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptional Redundancy:\u003c\/strong\u003e Ensures continuous operation and enhances reliability.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfigurable Safe-State (FAILOPT) Behaviors per Channel:\u003c\/strong\u003e Each channel can either HOLD LAST VALUE or SHED to a SAFE VALUE in case of IOM device electronics failure, with output defaulting to zero.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Read-Back and Alarm on Discrepancy:\u003c\/strong\u003e Ensures accurate monitoring and immediate issue notification.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNon-Incendive Output:\u003c\/strong\u003e Enables safe operation in hazardous environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOpen-Wire Detection:\u003c\/strong\u003e Detects and indicates open field wires with a Channel Soft Failure indication.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eDetail Specifications – High-Level Analog Output:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput \/ Output Model:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eCC-PAON01:\u003c\/strong\u003e High-Level Analog Output\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIOTA Models:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCC-TAON01:\u003c\/strong\u003e Non-Redundant 6”\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCC-TAON11:\u003c\/strong\u003e Redundant 12”\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Type:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\u003cli\u003e\u003cstrong\u003e4-20 mA\u003c\/strong\u003e\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Channels:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\u003cli\u003e\u003cstrong\u003e16\u003c\/strong\u003e\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Ripple:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003e\u0026lt; 100 mV peak-to-peak\u003c\/strong\u003e at power line frequency, across 250 Ω load\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Temperature Drift:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\u003cli\u003e\u003cstrong\u003e0.005% of Full Scale\/°C\u003c\/strong\u003e\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Readback Accuracy:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\u003cli\u003e\u003cstrong\u003e±4% of Full Scale\u003c\/strong\u003e\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Current Linearity:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\u003cli\u003e\u003cstrong\u003e± 0.05% of Full Scale nominal\u003c\/strong\u003e\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eResolution:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\u003cli\u003e\u003cstrong\u003e± 0.05% of Full Scale\u003c\/strong\u003e\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCalibrated Accuracy:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\u003cli\u003e\u003cstrong\u003e± 0.35% of Full Scale (25°C) including linearity\u003c\/strong\u003e\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDirectly Settable Output Current Range:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\u003cli\u003e\u003cstrong\u003e0 mA, 2.9 mA to 21.1 mA\u003c\/strong\u003e\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum Resistive Load:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\u003cli\u003e\u003cstrong\u003e800 ohms (24 V supply = 22 VDC through 28 VDC)\u003c\/strong\u003e\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum Output Compliant Voltage:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\u003cli\u003e\u003cstrong\u003e16 V (24 V supply = 22 VDC through 28 VDC)\u003c\/strong\u003e\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum Open Circuit Voltage:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\u003cli\u003e\u003cstrong\u003e22 V\u003c\/strong\u003e\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eResponse Time (DAC Input Code to Output):\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\u003cli\u003e\u003cstrong\u003eSettles to within 1% of final value within 80 ms\u003c\/strong\u003e\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGap (0 mA) of Output to Field on Switchover:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003e10 ms maximum\u003c\/strong\u003e (applies to Redundancy only)\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e\u003cstrong\u003e0.35 kg\u003c\/strong\u003e\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003eThis comprehensive set of features and specifications ensures that the CC-PAON01 module meets the demands of high-precision analog output applications while maintaining reliability and safety.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":49141050835226,"sku":"CC-PAON01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/CC-PUIO31.jpg?v=1718008278"},{"product_id":"cc-pdob01-51405043-175-honeywell-digital-output-24v-module","title":"CC-PDOB01 51405043-175 Honeywell - Digital Output 24V Module","description":"\u003ch2\u003eDigital Output - Bussed 24VDC – CC-PDOB01\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eFunction:\u003c\/strong\u003e The Digital Output Bussed 24VDC (DO24V) module delivers dependable 24V digital output signals, facilitating the control of process equipment, solenoid valves, and interposing relays with precision. Its support for high-energy outputs reduces the need for external components in the output loop.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eNotable Features:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eExtensive Internal Diagnostics:\u003c\/strong\u003e Ensures data integrity through continuous monitoring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptional Redundancy:\u003c\/strong\u003e Enhances reliability through redundant configurations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDirect\/Reverse Output Support:\u003c\/strong\u003e Provides flexibility in output configuration for various applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafe-state (FAILOPT) Behaviors:\u003c\/strong\u003e Configurable on a per-channel basis to HOLD THE LAST VALUE or SHED to a SAFE VALUE.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\"Fuse-less\" Short Circuit Protection:\u003c\/strong\u003e Detects and handles short circuits without blowing fuses, ensuring uninterrupted operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLatched, Pulsed, or Pulse-width Modulated Output (Per Channel):\u003c\/strong\u003e Offers versatile output modes to suit different requirements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGalvanic Isolation:\u003c\/strong\u003e Provides electrical isolation for safety and system integrity.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eBussed 24VDC DO:\u003c\/strong\u003e The Digital Output Bussed 24VDC supports both internal and external field power excitation. All outputs share a common return (ground), drawing power from either the system power supply or an externally connected 24V power supply. When utilizing an external source, outputs can be galvanically isolated from the Series C power system.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFuse-less Short Circuit Protection:\u003c\/strong\u003e This feature allows short circuits to exist without blowing any fuses. Internal circuits detect a short on a channel, removing power to the field connection. The channel remains de-energized until the short circuit is resolved.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFAILOPT:\u003c\/strong\u003e The Series C DO module supports the FAILOPT parameter on a per-channel basis, enabling users to configure output behavior according to their needs.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDetail Specifications - Bussed 24VDC DO:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput \/ Output Model:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eCC-PDOB01:\u003c\/strong\u003e 24Volt Digital Output, Field Isolated, Bussed output\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIOTA Model Numbers:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCC-TDOB01:\u003c\/strong\u003e Non-Redundant 9”\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCC-TDOB11:\u003c\/strong\u003e Redundant 12”\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Channels:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\u003cli\u003e\u003cstrong\u003e32\u003c\/strong\u003e\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Type:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\u003cli\u003e\u003cstrong\u003eSource\u003c\/strong\u003e\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLoad Voltage:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\u003cli\u003e\u003cstrong\u003e15-30 VDC Maximum\u003c\/strong\u003e\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLoad Current:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003ePer Channel: 0.5A\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003ePer 8 Channels: 4A\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003ePer Module: 6A\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGalvanic Isolation:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\u003cli\u003e\u003cstrong\u003e1500 VAC RMS or ±1500 VDC\u003c\/strong\u003e\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOn-State Voltage:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\u003cli\u003e\u003cstrong\u003e24 V (typ), load current @ 0.5A\u003c\/strong\u003e\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOff-State Voltage:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\u003cli\u003e\u003cstrong\u003e0V VDC (max) (3.3VDC max under no-load condition)\u003c\/strong\u003e\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOff-State Leak Current:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\u003cli\u003e\u003cstrong\u003e5.0 µA (max)\u003c\/strong\u003e\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTurn-On\/Turn-Off Time:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\u003cli\u003e\u003cstrong\u003e10 ms (max)\u003c\/strong\u003e\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGap (0 current) of Output to Field on Switchover:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eNone (0ms)\u003c\/strong\u003e (applies to Redundancy only)\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Voltage Variation:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\u003cli\u003e\u003cstrong\u003eSource Voltage – 150mV maximum\u003c\/strong\u003e\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e\u003cstrong\u003e0.35 kg\u003c\/strong\u003e\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth\u003c\/strong\u003e: 45 mm (1.77 in)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight\u003c\/strong\u003e: 121 mm (4.76 in)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDepth\u003c\/strong\u003e: 120 mm (4.72 in)\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eThis digital output module offers robust performance and a comprehensive set of features suitable for various industrial applications, ensuring precise control and system reliability.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":49141195276570,"sku":"CC-PDOB01","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/CC-PDOB01_3.jpg?v=1718010958"},{"product_id":"hart-analog-output-module-honeywell-cc-paox01","title":"HART Analog Output Module | Honeywell | CC-PAOX01","description":"\u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003cp\u003e\u003c\/p\u003e\u003ch2\u003eAnalog Output – CC-PAOX01\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eFunction:\u003c\/strong\u003e The Analog Output (AO) Module delivers constant current to actuators and recording\/indicating devices, ensuring precise control and monitoring in industrial processes.\u003c\/p\u003e\u003ch3\u003e\u003cstrong\u003eNotable Features:\u003c\/strong\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eExtensive Self-Diagnostics:\u003c\/strong\u003e Continuous monitoring for optimal performance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptional Redundancy:\u003c\/strong\u003e Ensures continuous operation and system reliability.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfigurable Safe-state (FAILOPT) Behaviors per Channel:\u003c\/strong\u003e Each channel can be set to HOLD LAST VALUE or SHED to a SAFE VALUE in case of device electronics failure, defaulting to zero, the safe state.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Read-Back and Alarm on Discrepancy:\u003c\/strong\u003e Enables accurate monitoring and immediate issue notification.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNon-Incendive Output:\u003c\/strong\u003e Safe operation in hazardous environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOpen-Wire Detection:\u003c\/strong\u003e Detects and indicates open field wires with a Channel Soft Failure indication.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003e\u003cstrong\u003eDetail Specifications – High-Level Analog Output:\u003c\/strong\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput \/ Output Model:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eCC-PAOX01:\u003c\/strong\u003e High-Level Analog Output\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIOTA Models:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCC-TAOX01:\u003c\/strong\u003e Non-Redundant 6”\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCC-TAOX11:\u003c\/strong\u003e Redundant 12”\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCC-GAOX11:\u003c\/strong\u003e Redundant 12”\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCC-GAOX21:\u003c\/strong\u003e Non-Redundant 6”\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Type:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\u003cli\u003e\u003cstrong\u003e4-20 mA\u003c\/strong\u003e\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Channels:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\u003cli\u003e\u003cstrong\u003e16\u003c\/strong\u003e\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Ripple:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003e\u0026lt; 100 mV peak-to-peak\u003c\/strong\u003e at power line frequency, across 250 Ω load\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Temperature Drift:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\u003cli\u003e\u003cstrong\u003e0.005% of Full Scale\/°C\u003c\/strong\u003e\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Readback Accuracy:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\u003cli\u003e\u003cstrong\u003e±4% of Full Scale\u003c\/strong\u003e\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Current Linearity:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\u003cli\u003e\u003cstrong\u003e± 0.05% of Full Scale nominal\u003c\/strong\u003e\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eResolution:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\u003cli\u003e\u003cstrong\u003e± 0.05% of Full Scale\u003c\/strong\u003e\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCalibrated Accuracy:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\u003cli\u003e\u003cstrong\u003e± 0.35% of Full Scale (25°C) including linearity\u003c\/strong\u003e\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDirectly Settable Output Current Range:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\u003cli\u003e\u003cstrong\u003e0 mA, 2.9 mA to 21.1 mA\u003c\/strong\u003e\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum Resistive Load:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\u003cli\u003e\u003cstrong\u003e800 ohms (24 V supply = 22 VDC through 28 VDC)\u003c\/strong\u003e\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum Output Compliant Voltage:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\u003cli\u003e\u003cstrong\u003e16 V (24 V supply = 22 VDC through 28 VDC)\u003c\/strong\u003e\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum Open Circuit Voltage:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\u003cli\u003e\u003cstrong\u003e22 V\u003c\/strong\u003e\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eResponse Time (DAC input code to output):\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\u003cli\u003e\u003cstrong\u003eSettles to within 1% of final value within 80 ms\u003c\/strong\u003e\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGap (0 mA) of Output to Field on Switchover:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003e10 ms maximum\u003c\/strong\u003e (applies to Redundancy only)\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e\u003c\/h3\u003e\u003cul\u003e\u003cli\u003e\u003cstrong\u003e0.35 kg\u003c\/strong\u003e\u003c\/li\u003e\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":49141251244314,"sku":"CC-PAOX01","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/CC-PAOX01_5.jpg?v=1718011953"},{"product_id":"honeywell-analog-input-module-cc-pain01-51410069-175","title":"Honeywell Analog Input Module CC-PAIN01 51410069-175","description":"\u003ch2\u003eAnalog Input – CC-PAIN01\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eFunction:\u003c\/strong\u003e The Analog Input Module is designed to accept high-level current input from sensing devices, ensuring accurate data acquisition and monitoring in industrial processes.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eNotable Features:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eExtensive Self-Diagnostics:\u003c\/strong\u003e Continuous monitoring for optimal performance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptional Redundancy:\u003c\/strong\u003e Enhances system reliability through redundant configurations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupplies Non-Incendive Field Power:\u003c\/strong\u003e Safe operation in hazardous environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFast Loop Scan:\u003c\/strong\u003e Efficiently scans input channels for rapid data acquisition.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNon-Incendive Power:\u003c\/strong\u003e Ensures safety in potentially explosive atmospheres.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eDetail Specifications – Analog Input:\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eParameter Specification\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eInput \/ Output Model:\u003c\/strong\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eCC-PAIN01:\u003c\/strong\u003e High-Level Analog Input\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eIOTA Models:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003cp\u003e\u003cstrong\u003eNon Redundant 6”:\u003c\/strong\u003e CC-TAIN01\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003e\u003cstrong\u003eRedundant 12”:\u003c\/strong\u003e CC-TAIN11\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003e\u003cstrong\u003eInput Type:\u003c\/strong\u003e Current (2-wire or self-powered transmitters)\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003e\u003cstrong\u003eInput Channels:\u003c\/strong\u003e 16 Channels (16 Single Ended)\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003e\u003cstrong\u003eCommon Mode Rejection Ratio, dc to 60 Hz (500 Ω source imbalance):\u003c\/strong\u003e 70 dB\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003e\u003cstrong\u003eA\/D Converter Resolution:\u003c\/strong\u003e 16 bits\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003e\u003cstrong\u003eInput Range:\u003c\/strong\u003e 4-20 mA (through 200 Ω)\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003e\u003cstrong\u003eNormal Mode Rejection Ratio, at 60 Hz:\u003c\/strong\u003e 20 dB\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003e\u003cstrong\u003eNormal Mode Filter Response:\u003c\/strong\u003e Single-pole RC, -3 dB @ 6.0 Hz\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003e\u003cstrong\u003eMaximum Normal Mode Input:\u003c\/strong\u003e ± 30 Volts\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003e\u003cstrong\u003eCrosstalk, dc to 60 Hz (channel-to-channel):\u003c\/strong\u003e -60 dB\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003e\u003cstrong\u003eInput Scan Rate:\u003c\/strong\u003e 50 ms\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHardware Accuracy (@ CMV = 0 V):\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e± 0.075% of full-scale (23.5°C ± 2°C)\u003c\/li\u003e\n\u003cli\u003e± 0.15% of full-scale (0 to 60°C)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003e\u003cstrong\u003eTransmitter Field Power Conditioning:\u003c\/strong\u003e Individually Protected Current Limiting Circuits for Class 1, Div 2 non-incendive interfacing. No fusing required\u003c\/p\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e\u003cstrong\u003e0.35 kg\u003c\/strong\u003e\u003c\/li\u003e\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":49141409480986,"sku":"CC-PAIN01","price":180.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/CC-PAIN01_1.jpg?v=1718015489"},{"product_id":"honeywell-cc-pdis01-51405042-175-digital-input-module","title":"Honeywell CC-PDIS01 51405042-175 Digital Input Module","description":"\u003ch3\u003e\u003cstrong\u003eParameter Specification:\u003c\/strong\u003e\u003c\/h3\u003e\u003cul\u003e\u003c\/ul\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Channel Scanning (PV):\u003c\/strong\u003e Normal = 20ms ; Fast = 5ms\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eInput Channels: 32\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDigital Input Resolution for Sequence of Events (SOE):\u003c\/strong\u003e 1ms\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGalvanic Isolation (any input terminal voltage referenced to common):\u003c\/strong\u003e 1500 VAC RMS or ±1500 VDC, Isolation Technique Optical (in IOM)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDI Power Voltage Range:\u003c\/strong\u003e 18 to 30 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eON Sense Voltage\/Current:\u003c\/strong\u003e 13 VDC (min) or 3 mA (min)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOFF Sense Voltage\/Current:\u003c\/strong\u003e 5 VDC (max) or 1.2 mA (max)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Impedance:\u003c\/strong\u003e 4.2 kΩ\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAbsolute Delay Across Input Filter and Isolation:\u003c\/strong\u003e 5 ms ± 20%\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField Resistance for Guaranteed ON Condition:\u003c\/strong\u003e 300 Ω max @ 15 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField Resistance for Guaranteed OFF Condition:\u003c\/strong\u003e 30 kΩ min @ 30 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"font-size: 0.875rem;\"\u003eWeight: \u003c\/strong\u003e\u003cspan style=\"font-size: 0.875rem;\"\u003e0.35 kg\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":49141450047770,"sku":"CC-PDIS01","price":110.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/CC-PDIS01_2.jpg?v=1718016578"},{"product_id":"cc-paoh51-honeywell-hart-analog-output-module-in-stock","title":"CC-PAOH51 Honeywell HART Analog Output Module In Stock","description":"\u003ch3\u003e\u003cstrong\u003eCC-PAOH51 Honeywell 51410070-275 Specification:\u003c\/strong\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Channels:\u003c\/strong\u003e 16\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Signals:\u003c\/strong\u003e 4-20mA, 0-20mA, 0-10V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHART Support:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation:\u003c\/strong\u003e\u003cul\u003e\n\u003cli\u003eChannel-to-channel: 500V\u003c\/li\u003e\n\u003cli\u003eChannel-to-system: 1500V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy:\u003c\/strong\u003e ±0.1% of full scale\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResolution:\u003c\/strong\u003e 16-bit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse Time:\u003c\/strong\u003e \u0026lt;20ms\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply:\u003c\/strong\u003e 24VDC (18-30VDC)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Consumption:\u003c\/strong\u003e 4W max\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Ripple:\u003c\/strong\u003e \u0026lt; 100 mV peak-to-peak at power line frequency, across 250 Ω load\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Temperature Drift:\u003c\/strong\u003e 0.005% of Full Scale\/°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Readback Accuracy:\u003c\/strong\u003e ±4% of Full Scale\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Current Linearity:\u003c\/strong\u003e ±0.05% of Full Scale nominal\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCalibrated Accuracy:\u003c\/strong\u003e ±0.35% of Full Scale (25°C) including linearity\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDirectly Settable Output Current Range:\u003c\/strong\u003e 0 mA, 2.9 mA to 21.1 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Resistive Load (24 V supply = 22 VDC through 28 VDC):\u003c\/strong\u003e 800 ohms\u003cspan\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 0.35 kg\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":49141478359322,"sku":"CC-PAOH51","price":140.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/CC-PAOH51.jpg?v=1718017076"},{"product_id":"cc-pdil51-51454405-175-honeywell-digital-input-24v-module","title":"CC-PDIL51 51454405-175 Honeywell Digital Input 24V Module","description":"\u003ch2 style=\"color: #2c3e50;\"\u003e\u003cstrong\u003eHoneywell CC-PDIL51 - 32-Channel Digital Input Module\u003c\/strong\u003e\u003c\/h2\u003e\u003ch3 style=\"color: #2c3e50;\"\u003e\u003cstrong\u003eIndustrial-Grade Signal Monitoring\u003c\/strong\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #e74c3c;\"\u003e\u003cstrong\u003e32-channel\u003c\/strong\u003e\u003c\/span\u003e 24VDC digital input\u003c\/li\u003e\n\u003cli\u003eAdvanced \u003cstrong\u003ediagnostic monitoring\u003c\/strong\u003e for reliability\u003c\/li\u003e\n\u003cli\u003eFlexible \u003cspan style=\"color: #e74c3c;\"\u003e\u003cstrong\u003epower options\u003c\/strong\u003e\u003c\/span\u003e (internal\/external)\u003c\/li\u003e\n\u003cli\u003e1000VAC galvanic isolation\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3 style=\"color: #2c3e50;\"\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e CC-PDIL51\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Voltage:\u003c\/strong\u003e 18-30VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eON Threshold:\u003c\/strong\u003e 13VDC (min) \/ 3mA (min)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOFF Threshold:\u003c\/strong\u003e 5VDC (max) \/ 1.2mA (max)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse Time:\u003c\/strong\u003e 5ms ±20%\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation:\u003c\/strong\u003e 1000VAC optical isolation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 0.35kg\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3 style=\"color: #2c3e50;\"\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eOn-board excitation power (no external marshalling needed)\u003c\/li\u003e\n\u003cli\u003eNon-incendive field power for hazardous areas\u003c\/li\u003e\n\u003cli\u003eDirect\/reverse input status indication\u003c\/li\u003e\n\u003cli\u003eOptional redundant configurations available\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3 style=\"color: #2c3e50;\"\u003e\u003cstrong\u003ePackage Contents\u003c\/strong\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eCC-PDIL51 digital input module\u003c\/li\u003e\n\u003cli\u003eInstallation documentation\u003c\/li\u003e\n\u003cli\u003eMounting hardware\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e12-month warranty\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3 style=\"color: #2c3e50;\"\u003e\u003cstrong\u003eShipping Options\u003c\/strong\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFedEx International Priority (2-3 days)\u003c\/li\u003e\n\u003cli\u003eUPS Worldwide Express\u003c\/li\u003e\n\u003cli\u003eDHL Global Mail\u003c\/li\u003e\n\u003cli\u003eReal-time package tracking\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3 style=\"color: #2c3e50;\"\u003e\u003cstrong\u003eIndustrial Applications\u003c\/strong\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProcess control monitoring\u003c\/li\u003e\n\u003cli\u003eEquipment status detection\u003c\/li\u003e\n\u003cli\u003eSafety interlock systems\u003c\/li\u003e\n\u003cli\u003eFactory automation\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3 style=\"color: #2c3e50;\"\u003e\u003cstrong\u003eTechnical FAQ\u003c\/strong\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What's the maximum wire length?\u003c\/strong\u003e\u003cbr\u003eA: Supports up to 300m with proper shielding\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Can it handle noisy environments?\u003c\/strong\u003e\u003cbr\u003eA: Yes, designed for industrial EMI conditions\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Is open wire detection available?\u003c\/strong\u003e\u003cbr\u003eA: No, this model doesn't include open wire detection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What's the power consumption?\u003c\/strong\u003e\u003cbr\u003eA\u0026gt; Approximately 5W typical operation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Are redundant models available?\u003c\/strong\u003e\u003cbr\u003eA: Yes, see CC-TDIL61 for redundant version\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp style=\"color: #2c3e50;\"\u003e\u003cstrong\u003eUpgrade your control system with the Honeywell CC-PDIL51 - reliable digital input monitoring for industrial applications!\u003c\/strong\u003e\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":49141527609626,"sku":"CC-PDIL51","price":80.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/CC-PDIL51.jpg?v=1718018019"},{"product_id":"cc-pdih01-honeywell-c300-digital-input-module","title":"CC-PDIH01 Honeywell C300 Digital Input Module","description":"\u003ch3\u003e\u003cstrong\u003eInput \/ Output Model: CC-PDIH01 51405041-175– Digital Input High Voltage\u003c\/strong\u003e\u003c\/h3\u003e\u003ch3\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Voltage:\u003c\/strong\u003e 24 VDC, 120 VAC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Current:\u003c\/strong\u003e 5 mA (24 VDC), 2 mA (120 VAC)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Impedance:\u003c\/strong\u003e 4.7 kΩ (24 VDC), 56 kΩ (120 VAC)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Input Frequency:\u003c\/strong\u003e 10 kHz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation Voltage:\u003c\/strong\u003e 1500 VAC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e 0 to 60°C (32 to 140°F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e -40 to 85°C (-40 to 185°F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRelative Humidity:\u003c\/strong\u003e 5 to 95% non-condensing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 45 x 120 x 120 mm (1.77 x 4.72 x 4.72 in)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 0.5 kg (1.1 lb)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":49141549629722,"sku":"CC-PDIH01","price":200.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/CC-PDIH01_1.jpg?v=1718018904"},{"product_id":"cc-paih51-honeywell-c300-hart-analog-input-module","title":"CC-PAIH51 Honeywell C300 Hart Analog Input Module","description":"\u003ch2\u003e\u003cstrong\u003eCC-PAIH51 51410069-276 Analog Input Module\u003c\/strong\u003e\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003e16-channel universal input module\u003c\/strong\u003e with 16-bit resolution for precision process monitoring. New factory-sealed with 12-month warranty.\u003c\/p\u003e\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eBrand:\u003c\/strong\u003e Honeywell\u003cbr\u003e\u003cstrong\u003ePart Number:\u003c\/strong\u003e CC-PAIH51 51410069-276\u003cbr\u003e\u003cstrong\u003eChannels:\u003c\/strong\u003e 16 single-ended\u003cbr\u003e\u003cstrong\u003eResolution:\u003c\/strong\u003e 16-bit\u003cbr\u003e\u003cstrong\u003eAccuracy:\u003c\/strong\u003e ±0.1% FS\u003cbr\u003e\u003cstrong\u003eSampling Rate:\u003c\/strong\u003e 250 S\/s\u003cbr\u003e\u003cstrong\u003eInput Impedance:\u003c\/strong\u003e \u0026gt;1MΩ (voltage), 250Ω (current)\u003cbr\u003e\u003cstrong\u003ePower:\u003c\/strong\u003e 24VDC (18-32VDC)\u003cbr\u003e\u003cstrong\u003eOperating Temp:\u003c\/strong\u003e 0-60°C\u003cbr\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e 63.5 x 124.46 x 307.34 mm\u003cbr\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e 300g\u003cbr\u003e\u003cstrong\u003eIsolation:\u003c\/strong\u003e Channel-to-channel 500V AC\u003c\/p\u003e\u003ch3\u003e\u003cstrong\u003eSignal Compatibility\u003c\/strong\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage:\u003c\/strong\u003e\u003cul\u003e\n\u003cli\u003e0-10V\u003c\/li\u003e\n\u003cli\u003e0-5V\u003c\/li\u003e\n\u003cli\u003e±10V\u003c\/li\u003e\n\u003cli\u003e±5V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent:\u003c\/strong\u003e\u003cul\u003e\n\u003cli\u003e0-20mA\u003c\/li\u003e\n\u003cli\u003e4-20mA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRTD:\u003c\/strong\u003e\u003cul\u003e\n\u003cli\u003ePt100\u003c\/li\u003e\n\u003cli\u003ePt1000\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermocouples:\u003c\/strong\u003e\u003cul\u003e\u003cli\u003eJ, K, T, E, R, S, B, N\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003e\u003cstrong\u003eComparison with Similar Modules\u003c\/strong\u003e\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eCC-PAIH51\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"https:\/\/www.powergearx.com\/products\/cc-pdih01-honeywell-digital-input-module-32-channel\/\" target=\"_blank\"\u003eCC-PDIH01\u003c\/a\u003e\u003c\/th\u003e\n\u003cth\u003e\u003ca href=\"https:\/\/plcdcshub.com\/product\/cc-paih01-honeywell-analog-input-module-51405038-175\/\" target=\"_blank\"\u003eCC-PAIH01\u003c\/a\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Type\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong style=\"color: #cc0000;\"\u003eUniversal Analog\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDigital\u003c\/td\u003e\n\u003ctd\u003eAnalog\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e16\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e32\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e16-bit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1-bit\u003c\/td\u003e\n\u003ctd\u003e12-bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSampling Rate\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e250 S\/s\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003ctd\u003e50 S\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Types\u003c\/td\u003e\n\u003ctd\u003eTC, RTD, V, I\u003c\/td\u003e\n\u003ctd\u003e24V DC\u003c\/td\u003e\n\u003ctd\u003eVoltage\/Current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003e\u003cstrong\u003eTechnical Parameters\u003c\/strong\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOvervoltage Protection:\u003c\/strong\u003e ±30V continuous\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommon Mode Rejection:\u003c\/strong\u003e \u0026gt;120 dB @ 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNoise Rejection:\u003c\/strong\u003e 50\/60 Hz @ 60 dB min\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUpdate Rate:\u003c\/strong\u003e 4ms per channel\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBurnout Detection:\u003c\/strong\u003e Current sources for TC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDielectric Strength:\u003c\/strong\u003e 1500V AC channel-to-bus\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003e\u003cstrong\u003eInstallation Guide\u003c\/strong\u003e\u003c\/h3\u003e\u003col\u003e\n\u003cli\u003eMount on compatible Honeywell rack\u003c\/li\u003e\n\u003cli\u003eConnect 24VDC power (18-32V range)\u003c\/li\u003e\n\u003cli\u003eWire signals respecting polarity\u003c\/li\u003e\n\u003cli\u003eVerify LED status indicators\u003c\/li\u003e\n\u003cli\u003eConfigure in control system software\u003c\/li\u003e\n\u003c\/ol\u003e\u003ch3\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/h3\u003e\u003cp\u003eDesigned for:\u003cbr\u003e• Honeywell Experion PKS\u003cbr\u003e• C300 Controller systems\u003cbr\u003e• Series C I\/O subsystems\u003c\/p\u003e\u003ch3\u003e\u003cstrong\u003ePackage Contents\u003c\/strong\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eCC-PAIH51 module\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eInstallation documentation\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003e\u003cstrong\u003eWarranty \u0026amp; Shipping\u003c\/strong\u003e\u003c\/h3\u003e\u003cp\u003e\u003cstrong style=\"color: #008000;\"\u003e12-month manufacturer warranty\u003c\/strong\u003e\u003cbr\u003eFedEx, UPS, DHL global shipping\u003cbr\u003eESD-protected packaging\u003c\/p\u003e\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eQ: Can it measure 4-20mA and thermocouples simultaneously?\u003c\/strong\u003e\u003cbr\u003eA: Yes, per-channel configuration allows mixed signals\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eQ: What's the advantage of 16-bit resolution?\u003c\/strong\u003e\u003cbr\u003eA: Enables precise measurement (0.0015% resolution)\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eQ: Is isolation between channels?\u003c\/strong\u003e\u003cbr\u003eA: Yes, 500V AC channel-to-channel isolation\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eQ: Compatible with older Honeywell systems?\u003c\/strong\u003e\u003cbr\u003eA: Works with C Series I\/O since 2003\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eQ: How are thermocouples compensated?\u003c\/strong\u003e\u003cbr\u003eA: Automatic cold junction compensation\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":49141572763930,"sku":"CC-PAIH51","price":150.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/CC-PAIH51_2.jpg?v=1718019799"},{"product_id":"cc-pail51-analog-input-module-honeywell","title":"CC-PAIL51 Analog Input Module - Honeywell","description":"\u003cp\u003e\u003cstrong\u003eLow Level Analog (Temperature) Input – CC-PAIL51\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFunction:\u003c\/strong\u003e The Low Level IOP module supports up to 16 channels of temperature inputs, with each channel configurable for either Thermocouple (TC) or Resistance Temperature Device (RTD) inputs. Unlike the LLMUX (CC-PAIM01), this module supports 16 channels directly on the Series-C IOTA, eliminating the need for an external Process Manager FTA.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eNotable Features:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTC and RTD Operation\u003c\/strong\u003e: Each channel can be configured for either thermocouple or RTD inputs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCold Junction Compensation\u003c\/strong\u003e: Ensures accurate temperature readings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e1 Second PV Scanning\u003c\/strong\u003e: Provides up-to-date temperature readings every second.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOTD Protection\u003c\/strong\u003e: Offers configurable Open Thermocouple Detection protection.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eDetailed Specifications:\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eInput \/ Output Model:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e CC-PAIL51\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIOTA (16pt) Model:\u003c\/strong\u003e CC-TAIL51 9”\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eInput Type:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eThermocouple or RTD:\u003c\/strong\u003e Configurable per channel\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eTemperature:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -40 to +70 ℃\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e -40 to +85 ℃\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eInput Channels:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation:\u003c\/strong\u003e Fully isolated Channel to Channel and Channel to Power System\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eScan Rate:\u003c\/strong\u003e 1 Second\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannel Bandwidth:\u003c\/strong\u003e 0 to 4.7 Hz (-3 dB)\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eNominal Input Range (TC only):\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eRange:\u003c\/strong\u003e -20 to +100 millivolts\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eMaximum Normal Mode Continuous Input:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermocouple:\u003c\/strong\u003e -10 to +10 volts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRTD:\u003c\/strong\u003e -1 to +2 Volts @ 100 milliamps\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eAccuracy and Stability:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGain Error:\u003c\/strong\u003e 0.050% full scale max\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature Stability (TC, Millivolt inputs):\u003c\/strong\u003e +\/-20 ppm per max\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRTD Inputs:\u003c\/strong\u003e +\/-20 ppm per max\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLong Term Drift:\u003c\/strong\u003e 500 ppm\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eInput Impedance (TC only):\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eImpedance:\u003c\/strong\u003e 1 megohm at dc\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eCommon Mode Voltage (CMV):\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eRespect to Power System common, dc to 60 Hz:\u003c\/strong\u003e +\/-250 VDC or VAC RMS\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eCommon Mode Rejection Ratio (CMRR):\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003e50 or 60 Hz (with 1000 ohms source impedance max.):\u003c\/strong\u003e 120 dB min\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eChannel Isolation:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eVoltage, Channel-to-Channel, dc to 60 Hz:\u003c\/strong\u003e +\/-250 VDC or VAC RMS\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eCrosstalk:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003edc to 60 Hz:\u003c\/strong\u003e 80 dB (120 dB at 50 and 60 Hz)\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eNoise Rejection:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eNMRR at 50\/60 Hz:\u003c\/strong\u003e 60 dB min\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eLine Frequency Integration:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eSelection:\u003c\/strong\u003e Fixed selection of 50 Hz or 60 Hz\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eRTD Sensor Excitation Current:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eCurrent:\u003c\/strong\u003e 1 milliamp\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eCold Junction Compensation:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eRange:\u003c\/strong\u003e -20 to +60 ℃ (+\/-0.5 ℃ typical)\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eTC Linearization Accuracy:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eAccuracy:\u003c\/strong\u003e ± 0.05 Ω \/ ℃\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eOpen Thermocouple Detection (OTD):\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eDetection:\u003c\/strong\u003e Each conversion qualified, ≤ 1000 Ω = guaranteed no-trip, ≥ 1500 Ω guaranteed trip.\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eRTD Max Lead Resistance:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eResistance:\u003c\/strong\u003e 15 Ω\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eSupported RTD Types:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePt: 100 ohm DIN 4376:\u003c\/strong\u003e -180 to +800 ℃\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePt: 100 ohm JIS C-1604:\u003c\/strong\u003e -180 to +650 ℃\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNi: 120 ohm ED #7:\u003c\/strong\u003e -45 to +315 ℃\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCu: 10 ohm SEER:\u003c\/strong\u003e -20 to +250 ℃\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCu: 50 ohm SEER:\u003c\/strong\u003e -50 to +150 ℃\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eSupported Thermocouple Types:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eANSI specification J:\u003c\/strong\u003e -200 to +1200 ℃\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eANSI specification K:\u003c\/strong\u003e -100 to +1370 ℃\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eANSI specification E:\u003c\/strong\u003e -200 to +1000 ℃\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eANSI specification T:\u003c\/strong\u003e -230 to +400 ℃\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eANSI specification B:\u003c\/strong\u003e +100 to +1820 ℃\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eANSI specification S:\u003c\/strong\u003e 0 to +1700 ℃\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eANSI specification R:\u003c\/strong\u003e 0 to +1700 ℃\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eSupported Millivolt Types:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eRange:\u003c\/strong\u003e -20 to +100 millivolts\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eModule Weight:\u003c\/strong\u003e 0.35 kg\u003c\/li\u003e\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":49146407354650,"sku":"CC-PAIL51","price":150.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/CC-PAIL51_3.jpg?v=1718084615"},{"product_id":"cc-pdod51-honeywell-digital-output-module","title":"CC-PDOD51 Honeywell Digital Output Module","description":"\u003cp\u003e\u003cstrong\u003eDigital Output – SINK TYPE 24VDC – CC-PDOD51\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFunction:\u003c\/strong\u003e The Digital Output bussed 24VDC (DO24V) module reliably switches 24V digital output signals to control process equipment, solenoid valves, and interposing relays.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eNotable Features:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eExtensive Internal Diagnostics:\u003c\/strong\u003e Ensures data integrity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptional Redundancy:\u003c\/strong\u003e Enhances reliability.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectronic Overcurrent Protection:\u003c\/strong\u003e Prevents damage from excess current.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfigurable Safe-state (FAILOPT):\u003c\/strong\u003e Allows setting outputs to a safe state upon failure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLatched, Pulsed, or Pulse-width Modulated Output:\u003c\/strong\u003e Configurable per channel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBussed 24VDC DO:\u003c\/strong\u003e Supports both internal and external field power excitation. Outputs share a common ground and can be isolated from the Series C power system when using an external source.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eFAILOPT:\u003c\/strong\u003e The Series C DO module supports the FAILOPT parameter on a per-channel basis. Output behavior can be configured to either hold the last value or shed to a user-defined safe value.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDetailed Specifications:\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eInput \/ Output Model:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e CC-PDOD51 - 24 Volt Digital Output, Field Isolated, Bussed Output, Coated\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eIOTA Model Numbers:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNon-Redundant:\u003c\/strong\u003e CC-TDOD51 (9”)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRedundant:\u003c\/strong\u003e CC-TDOD61 (12”)\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eOutput Channels:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eChannels:\u003c\/strong\u003e 32\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eOutput Type:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e SINK (Open Drain)\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eLoad Voltage:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eVoltage:\u003c\/strong\u003e 15-30 VDC Maximum\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eLoad Current:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eCurrent:\u003c\/strong\u003e 0.1 A per channel (Max)\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eGalvanic Isolation:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eIsolation:\u003c\/strong\u003e 1000 VAC RMS for System-to-Field isolation (user-supplied field power)\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eOn-State Voltage:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eVoltage:\u003c\/strong\u003e 0V VDC (load current @ 0.1A max)\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eOff-State Voltage:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eVoltage:\u003c\/strong\u003e 24 V (typical)\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eOff-State Leak Current:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eCurrent:\u003c\/strong\u003e 100 µA (max)\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eTurn-On\/Turn-Off Time:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eTime:\u003c\/strong\u003e 10 ms (max)\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eGap (0 current) of Output to Field on Switchover:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eSwitchover:\u003c\/strong\u003e None (0ms) (applies to redundancy only)\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eModule Weight:\u003c\/strong\u003e 0.35 kg\u003c\/li\u003e\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":49146461028634,"sku":"CC-PDOD51","price":120.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/CC-PUIO31.jpg?v=1718008278"},{"product_id":"cc-ppix01-honeywell-analog-input-module","title":"CC-PPIX01 Honeywell Analog Input Module","description":"\u003cp\u003e\u003cstrong\u003ePulse Input – CC-PPIX01\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFunction:\u003c\/strong\u003e The Pulse Input Module (PIM) enables the Experion C300 controller to monitor various pulse input field values. It processes signals from pulse-generating devices, providing calculated rates and accumulated totals. The module includes a \"fast cutoff\" feature to halt dosing operations when a threshold is reached. Its high accuracy and repeatability make it ideal for metering and custody transfer applications, including compliance with ISO-6551 for dual pulse inputs.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eNotable Features:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eExtensive Self-Diagnostics:\u003c\/strong\u003e Ensures reliable operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptional Redundancy:\u003c\/strong\u003e Increases system reliability.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Accuracy Measurements:\u003c\/strong\u003e Measures frequency, period, and pulse width with high precision.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupport for MeterSuite Application:\u003c\/strong\u003e Ideal for metering applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eISO 6551 Fidelity:\u003c\/strong\u003e Complies with ISO standards for dual pulse inputs.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eDetailed Specifications:\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eInput \/ Output Model:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e CC-PPIX01 - Pulse Input\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eIOTA Model:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e CC-TPIX11 - Redundant 12”\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eNumber of Inputs:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInputs:\u003c\/strong\u003e 8 (Single) or 4 (Dual)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupport:\u003c\/strong\u003e Mixed combination of Single\/Dual Input Channels\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eNumber of Outputs:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eOutputs:\u003c\/strong\u003e 2\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eInput Type:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e High-impedance, differential voltage, optically isolated (1000 VDC)\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eFrequency Range:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle Channel:\u003c\/strong\u003e 0 - 100 KHz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Pulse Channel:\u003c\/strong\u003e 0 – 10 KHz\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eFrequency Accuracy:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eAccuracy:\u003c\/strong\u003e +\/- 0.001% of Reading (0.5 Hz – 100 KHz)\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eInput Voltage:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eRange:\u003c\/strong\u003e 0 to 35 VDC\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eInput Voltage Trip Points:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Setting:\u003c\/strong\u003e\u003cul\u003e\n\u003cli\u003eLow to High: 8.4V\u003c\/li\u003e\n\u003cli\u003eHigh to Low: 7.7V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLow Setting:\u003c\/strong\u003e\u003cul\u003e\n\u003cli\u003eLow to High: 2.8V\u003c\/li\u003e\n\u003cli\u003eHigh to Low: 2.0V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eInput Edge Selection:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eConfigurable:\u003c\/strong\u003e Rising Edge (Default) or Falling Edge\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eChannel Input Impedance:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eImpedance:\u003c\/strong\u003e Greater than 70 K Ohms\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eInput Channel Function:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eFunctions:\u003c\/strong\u003e Frequency (PV), Accumulated Value (AV), Pulse Width High, Pulse Width Low, Period\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eIsolated \/ Bussed Input Jumper Option:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eConfiguration:\u003c\/strong\u003e Isolated or bussed selection per channel\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eInternal \/ External Excitation Power:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eSupport:\u003c\/strong\u003e Internal 24V operation or external excitation voltage +5 to +30VDC\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eMinimum Pulse Width:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePulse Width Rejection Off:\u003c\/strong\u003e 3us\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePulse Width Rejection On:\u003c\/strong\u003e 20us\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eFast Cutoff Output Type (Channels 7 and 8 only):\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e Optically isolated (1500 Vrms) solid-state relay with integral user-replaceable fuse (2.5 A)\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eFast Cutoff Latency:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eLatency:\u003c\/strong\u003e 1ms (max)\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eFast Cutoff Relay Output Characteristics:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage:\u003c\/strong\u003e 5V to 60VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent:\u003c\/strong\u003e 0.001A to 2A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOff State Leakage Current:\u003c\/strong\u003e 100uA max at 60VDC\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eMeterSuite Specifications:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupport:\u003c\/strong\u003e Supported\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProver Pulse Output Function:\u003c\/strong\u003e Provides “Good Pulses” from selected dual channel pair to support Prover applications. Supports up to 5 Pulse IOTAs bussed together.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProver Electrical Characteristics:\u003c\/strong\u003e Open Emitter source driver – Referenced to System Ground, Open Circuit Voltage: 22V, Short Circuit Current Limit: 35mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePulse Data Fidelity Compliance:\u003c\/strong\u003e Level A Fidelity per ISO 6551:1995\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eModule Weight:\u003c\/strong\u003e 0.35 kg\u003c\/li\u003e\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":49146498711834,"sku":"CC-PPIX01","price":80.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/c-_13_28c2fd64-1621-41ab-ba5b-2293b2afd70f.jpg?v=1718086030"},{"product_id":"honeywell-quad-processor-fc-qpp-0002","title":"Honeywell Quad Processor FC-QPP-0002","description":"\u003ch2\u003e\u003cstrong\u003eHoneywell QPP-0002: High-Availability Quad Processor for Critical Control\u003c\/strong\u003e\u003c\/h2\u003e\u003cp\u003eThe \u003cb\u003eQPP-0002\u003c\/b\u003e ensures uninterrupted industrial automation. This processor combines dual synchronous operation with 1oo2D redundancy for mission-critical systems.\u003c\/p\u003e\u003ch3\u003e\u003cstrong\u003eCore Capabilities\u003c\/strong\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eDual synchronous processors\u003c\/b\u003e for parallel task execution\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e1oo2D redundancy\u003c\/b\u003e meets SIL3 safety requirements\u003c\/li\u003e\n\u003cli\u003eBattery-backed RAM (\u003cb\u003eBKM-0001\u003c\/b\u003e) prevents data loss\u003c\/li\u003e\n\u003cli\u003eFour \u003cb\u003eIObus drivers\u003c\/b\u003e for expanded device connectivity\u003c\/li\u003e\n\u003cli\u003eBuilt-in \u003cb\u003ewatchdog timer\u003c\/b\u003e monitors system health\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eModel:\u003c\/b\u003e QPP-0002 (FC-QPP-0002)\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eOperating Temp:\u003c\/b\u003e -5°C to +85°C internal\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003ePower Input:\u003c\/b\u003e 24V DC (-15%\/+30% range)\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eEmergency Input:\u003c\/b\u003e 24V shutdown signal\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eOutput Current:\u003c\/b\u003e 750mA per channel\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eDimensions:\u003c\/b\u003e 176 × 88.5 × 212 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eCertifications:\u003c\/b\u003e CE, UL, CSA, TÜV, FM\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003e\u003cstrong\u003eReliability Features\u003c\/strong\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eContinuous voltage monitoring (5V\/24V)\u003c\/li\u003e\n\u003cli\u003eData comparators verify processor synchronization\u003c\/li\u003e\n\u003cli\u003eDiagnostic display for real-time troubleshooting\u003c\/li\u003e\n\u003cli\u003eReverse polarity protection on all inputs\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003e\u003cstrong\u003eInstallation \u0026amp; Safety\u003c\/strong\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eKey-locked STOP position for safe maintenance\u003c\/li\u003e\n\u003cli\u003eDIN rail or panel mounting options\u003c\/li\u003e\n\u003cli\u003eHumidity resistant (10-95% non-condensing)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003e\u003cstrong\u003eWarranty \u0026amp; Logistics\u003c\/strong\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e12-month manufacturer warranty\u003c\/li\u003e\n\u003cli\u003eGlobal shipping via FedEx\/UPS\/DHL\u003c\/li\u003e\n\u003cli\u003e1.3kg compact industrial design\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eQ: What battery module is required?\u003c\/b\u003e\u003cbr\u003eA: BKM-0001 provides RAM backup power.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eQ: Maximum IObus device connections?\u003c\/b\u003e\u003cbr\u003eA: Four external devices via IObus drivers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eQ: Redundancy configuration time?\u003c\/b\u003e\u003cbr\u003eA: Automatic failover under 100ms.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eQ: Suitable for hazardous areas?\u003c\/b\u003e\u003cbr\u003eA: FM approval for Class I Div 2.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eQ: Replacement procedure?\u003c\/b\u003e\u003cbr\u003eA: Only in STOP position per safety protocol.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":49146649379098,"sku":"FC-QPP-0002","price":60.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/FC-QPP-0002_2.jpg?v=1718087297"},{"product_id":"fs-tsdo-0824-digital-output-fta-honeywell","title":"FS-TSDO-0824 Digital Output FTA Honeywell","description":"\u003cp\u003e\u003cstrong\u003eTSDO-0824 Safe Digital Output FTA (24 V DC, 8 Channels)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOverview:\u003c\/strong\u003e The TSDO-0824 serves as a field termination assembly (FTA) module, linking the system interconnection cable SICC-0001\/Lx with external field wiring via screw terminals. It facilitates the connection of up to eight channels from redundant pairs of SDO-0824 modules through the system interconnection cable.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInterface:\u003c\/strong\u003e Connects the system interconnection cable (SICC-0001\/Lx) to external field wiring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannel Support:\u003c\/strong\u003e Supports eight channels from redundant pairs of SDO-0824 modules.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Features a universal snap-in provision for standard DIN EN rails, ensuring easy and secure installation.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eGeneral:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eType Numbers:\u003c\/strong\u003e FS-TSDO-0824, FC-TSDO-0824\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals:\u003c\/strong\u003e CE, TUV, UL, CSA, FM\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003ePower:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Channels:\u003c\/strong\u003e 8\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Voltage:\u003c\/strong\u003e 36 V DC (IEC 1010 - 1990)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOvervoltage Category:\u003c\/strong\u003e 3 (Table D.12)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Continuous Current per Channel:\u003c\/strong\u003e 1.5 A\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003ePhysical Dimensions:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Dimensions:\u003c\/strong\u003e 60 × 70 × 58 mm (L × W × H), 2.36 × 2.76 × 2.28 in\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDIN EN Rails:\u003c\/strong\u003e TS32 \/ TS35 × 7.5\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUsed Rail Length:\u003c\/strong\u003e 61 mm (2.40 in)\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eTermination:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eScrew Terminals\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax. Wire Diameter:\u003c\/strong\u003e 2.5 mm² (AWG 14)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStrip Length:\u003c\/strong\u003e 7 mm (0.28 in)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTightening Torque:\u003c\/strong\u003e 0.5 Nm (0.37 ft-lb)\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eModule Weight:\u003c\/strong\u003e 0.2 kg\u003c\/li\u003e\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":49146709279002,"sku":"FS-TSDO-0824","price":280.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/FS-TSDO-0824_2.jpg?v=1718088133"},{"product_id":"fs-sdol-0424-honeywell-digital-output-module","title":"FS-SDOL-0424 Honeywell Digital Output Module","description":"\u003cp\u003e\u003cstrong\u003eFC-SDOL-0424 Safe Loop-Monitored Digital Output Module\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOverview:\u003c\/strong\u003e The FC-SDOL-0424 is a safe loop-monitored digital output module designed with four 24 V DC, 1 A loop-monitored output channels. This module is capable of driving loads up to 24 W, making it ideal for various industrial applications.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Channels:\u003c\/strong\u003e Four 24 V DC output channels suitable for driving resistive or inductive loads.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSuppression Diodes:\u003c\/strong\u003e Each output includes a suppression diode for inductive loads, ensuring safe operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoop Monitoring:\u003c\/strong\u003e Features loop monitoring for added safety, including lead breakage detection and short-circuit detection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLED Indicators:\u003c\/strong\u003e Each channel is equipped with an LED indicator for status monitoring, providing visual feedback during testing and operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFully Tested:\u003c\/strong\u003e Outputs, including suppression diodes and monitoring functions, are fully tested and suitable for safe applications.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eLED Indicator Functionality:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOff Channel:\u003c\/strong\u003e LED gives short intermittent flashes indicating lead breakage tests.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOn Channel (Non-Redundant Configuration):\u003c\/strong\u003e LED gives very short periodic flashes during internal switch-off self-tests.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOn Channel (Redundant Configuration):\u003c\/strong\u003e LED appears to flash intermittently due to self-test synchronization between Control Processors.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eGeneral:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eType Numbers:\u003c\/strong\u003e FS-SDOL-0424, FC-SDOL-0424\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompliance:\u003c\/strong\u003e CE, TUV, UL, CSA, FM\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eSpace Requirements:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 4 TE, 3 HE (= 4 HP, 3U)\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003ePower:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupply Voltage:\u003c\/strong\u003e 5 V DC, 24 V DC (internal and external)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Requirements:\u003c\/strong\u003e\u003cul\u003e\n\u003cli\u003e5V DC: 15 mA\u003c\/li\u003e\n\u003cli\u003e24V DC Internal: 50 mA\u003c\/li\u003e\n\u003cli\u003e24V DC External: 15 mA (without output load)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eOutput:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Channels:\u003c\/strong\u003e 4\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Specification:\u003c\/strong\u003e 24 V DC solid-state source, short-circuit proof\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Channel Current:\u003c\/strong\u003e 1 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Total Module Load:\u003c\/strong\u003e 3.6 A (module dissipation limit)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Load Inductance:\u003c\/strong\u003e 0.5 H\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Load Capacitance:\u003c\/strong\u003e 1 μF\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Drop:\u003c\/strong\u003e \u0026lt; 1.3 V at 1 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOff Current:\u003c\/strong\u003e \u0026lt; 0.1 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Sense Voltage Drop:\u003c\/strong\u003e \u0026lt; 1 V at 1 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWDG Input Current:\u003c\/strong\u003e 4 mA\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eModule Weight:\u003c\/strong\u003e 0.2 kg\u003c\/li\u003e\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":49146798801178,"sku":"FS-SDOL-0424","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/FS-SDOL-0424_4.jpg?v=1718089297"},{"product_id":"fc-bkm-0001-honeywell-battery-and-key-switch-module","title":"FC-BKM-0001 Honeywell - Battery and Key Switch Module","description":"\u003cp\u003e\u003cstrong\u003eBKM-0001 Battery and Key Switch Module\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOverview:\u003c\/strong\u003e The Battery and Key Switch Module (BKM-0001) is a crucial component within the Controller chassis, designed to ensure continuous power supply and provide essential safety functions for system operation.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFeatures and Components:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBatteries:\u003c\/strong\u003e Contains two batteries, one for each Control Processor, ensuring continuous power supply for system operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eForce Enable Key Switch:\u003c\/strong\u003e Allows authorized personnel to enable system operation securely.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReset Key Switch:\u003c\/strong\u003e Enables system reset functionality for maintenance or troubleshooting purposes.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOperating Conditions:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -5°C to +70°C (+23°F to +158°F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e -40°C to +85°C (-40°F to +185°F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRelative Humidity:\u003c\/strong\u003e 10-95% (non-condensing)\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eApprovals:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003eCE, TUV, UL, CSA, FM\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003ePower Supply:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage:\u003c\/strong\u003e 24V DC with a tolerance of -15% to +30%\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupply Current:\u003c\/strong\u003e Maximum 20 mA for each 24V DC, typically 7 mA shared load\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e5V Supply Voltage:\u003c\/strong\u003e 5V DC with a tolerance of ±10%\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e5V Supply Current:\u003c\/strong\u003e Maximum 10 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e+24V_red Output Supply Voltage:\u003c\/strong\u003e 14-31V DC, with short circuit-proof design\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eBattery Specifications:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e SAFT LS14500CFG batteries, lithium Thionyl Chloride type\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNominal Voltage:\u003c\/strong\u003e 3.6V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCapacity:\u003c\/strong\u003e Greater than 2 Ah\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003ePhysical Specifications:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 176 x 35.2 x 224 mm (H x W x D)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 660 g\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":49146853949722,"sku":"FC-BKM-0001","price":130.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/FC-BKM-0001_1.jpg?v=1718089499"},{"product_id":"fc-io-0001-i-o-extender-module-honeywell","title":"FC-IO-0001  I\/O Extender Module - Honeywell","description":"\u003cp\u003e\u003cstrong\u003eIO Extender Module\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOverview:\u003c\/strong\u003e The IO extender module facilitates communication between the Control Processor and IO modules within an IO chassis. Its specifications and placement details differ based on whether the chassis is non-redundant or redundant.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePlacement Details:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNon-redundant IO Chassis (IOCHAS-0001S):\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eContains one IO-0001 module.\u003c\/li\u003e\n\u003cli\u003eLocated in slot 21.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRedundant IO Chassis (IOCHAS-0001R):\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eContains two IO-0001 modules.\u003c\/li\u003e\n\u003cli\u003eLocated in slots 20 and 21.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eType Numbers:\u003c\/strong\u003e FS-IO-0001, FC-IO-0001\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals:\u003c\/strong\u003e CE, TUV, UL, CSA, FM\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eSpace Requirements:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e4 TE, 3 HE (4 HP, 3U)\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003ePower Requirements:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage:\u003c\/strong\u003e 5 V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent:\u003c\/strong\u003e 35 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRipple Content:\u003c\/strong\u003e \u0026lt; 50 mV p-p\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eConnector Code:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule:\u003c\/strong\u003e Holes A5, A7\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChassis:\u003c\/strong\u003e Large pins A5, A7\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003ePhysical Specifications:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 0.2 kg\u003c\/li\u003e\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":49147033157914,"sku":"FC-IO-0001","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/FC-IO-0001_2.jpg?v=1718090450"},{"product_id":"honeywell-power-supply-unit-fc-psu-uni2450u","title":"Honeywell | Power Supply Unit | FC-PSU-UNI2450U","description":"\u003cp\u003e\u003cstrong\u003eHoneywell FC-PSU-UNI2450U Power Supply\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOverview:\u003c\/strong\u003e The Honeywell FC-PSU-UNI2450U is a UL508 approved switched-mode DC power supply engineered for high efficiency and reliability across diverse industrial applications. With an efficiency exceeding 85% at 187 V AC and over 80% at 93.5 V AC, this power supply unit offers exceptional performance. It offers dual output options of either 25 V DC at 48 A or 28 V DC at 43 A, catering to varied power requirements.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eMain Features:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Over-Voltage Protection:\u003c\/strong\u003e Complies with IEC 61508 functional safety requirements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eON\/OFF Switch:\u003c\/strong\u003e Allows online replacement in live systems with isolated AC and DC connectors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Limit Feature:\u003c\/strong\u003e Restricts maximum output power to 1200 W.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnder-Voltage Alarm:\u003c\/strong\u003e Signals if voltage drops below 22 V.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Diode:\u003c\/strong\u003e Supports parallel operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature Range:\u003c\/strong\u003e\u003cul\u003e\n\u003cli\u003eFC-PSU-UNI2450U: -5°C to 70°C\u003c\/li\u003e\n\u003cli\u003eFA-PSU-UNI2450U: -40°C to 70°C (Hazloc Certified)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOverload and Short-Circuit Protection:\u003c\/strong\u003e Ensures optimal safety.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e100ms Hold-Up Time:\u003c\/strong\u003e Maintains stability during brief interruptions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFAN Alarm:\u003c\/strong\u003e Monitors fan status.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertification:\u003c\/strong\u003e UL 508, EN 61558-2-16 compliant; FA-Version is also ATEX, IECEx, and CSA approved.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Voltage:\u003c\/strong\u003e 110-240 V AC (operating limits: 93-253 V AC)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Frequency Range:\u003c\/strong\u003e 47-63 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Consumption at No Load:\u003c\/strong\u003e 13 W\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Factor:\u003c\/strong\u003e Close to 1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 420.5 × 140 × 90 mm (16.57 × 5.51 × 3.54 in)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 5.7 kg (12.5 lb)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e -25°C to +85°C (-13°F to +185°F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -5°C to +70°C (23°F to +158°F)\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eOutput:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage:\u003c\/strong\u003e 25 V DC or 28 V DC with dual overvoltage protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRipple and Noise:\u003c\/strong\u003e \u0026lt; 40 mVpp\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Current:\u003c\/strong\u003e\u003cul\u003e\n\u003cli\u003e25 V DC: 48 A at -5°C to +50°C (23°F to +122°F)\u003c\/li\u003e\n\u003cli\u003e28 V DC: 43 A at -5°C to +50°C (23°F to +122°F)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEfficiency:\u003c\/strong\u003e \u0026gt;85% at 220-240 V AC; \u0026gt;80% at 110-120 V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation:\u003c\/strong\u003e\u003cul\u003e\n\u003cli\u003eInput to output: 3750 Vrms\u003c\/li\u003e\n\u003cli\u003eInput to case: 2500 Vrms\u003c\/li\u003e\n\u003cli\u003eOutput to case: 500 V DC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eConnectors:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC Input:\u003c\/strong\u003e IEC 60320 C20 inlet type socket, 16 A with retaining clip\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDC Output:\u003c\/strong\u003e Phoenix PCV6-16\/2-G1F-10,163 with locking screws\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAlarm Contact:\u003c\/strong\u003e Phoenix MC 1,5\/3-G-3,81, with contact rating 100 mA \/ 30 V\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eAdditional Features:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Limit:\u003c\/strong\u003e Independent regulation circuits for output voltage limitation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUndervoltage Alarm Contact:\u003c\/strong\u003e Relay de-energizes when output voltage drops below 22 V DC.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":49147075625242,"sku":"FC-PSU-UNI2450U","price":145.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/FC-PSU-UNI2450U_1.jpg?v=1718090946"},{"product_id":"fc-sai-1620m-honeywell-analog-input-module","title":"FC-SAI-1620M Honeywell - Analog Input Module","description":"\u003cp\u003e\u003cstrong\u003eSAI-1620m Safe High-Density Analog Input Module\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOverview:\u003c\/strong\u003e The SAI-1620m analog input module is designed to offer sixteen safe analog input channels (0-4 V) compliant with SIL3 safety class as per IEC 61508 standards. It is ideal for applications requiring high-density and high-safety analog input solutions.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAnalog Input Channels:\u003c\/strong\u003e Sixteen channels with a 0-4 V input range, supporting various analog signals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolated Analog 0 V:\u003c\/strong\u003e All sixteen channels share a common isolated analog 0 V.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField Signal Conversion:\u003c\/strong\u003e Capable of converting 0-20 mA signals using field termination assembly modules or dedicated analog input conversion modules.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSelf-Test Functionality:\u003c\/strong\u003e Controlled by the Safety Manager Controller, it performs self-tests to ensure absolute accuracy, correct conversion over the full range, checks for crosstalk between inputs, channel input filters, and internal supply voltages.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eType Numbers:\u003c\/strong\u003e FS-SAI-1620m, FC-SAI-1620m, FA-SAI-1620m\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals:\u003c\/strong\u003e CE, TUV, UL, CSA, FM\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpace Requirements:\u003c\/strong\u003e 4 TE, 3 HE (= 4 HP, 3U)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Requirements:\u003c\/strong\u003e\u003cul\u003e\n\u003cli\u003e5V DC: 35 mA\u003c\/li\u003e\n\u003cli\u003e24V DC: 35 mA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput:\u003c\/strong\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Channels:\u003c\/strong\u003e 16\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Range:\u003c\/strong\u003e 0-4.1 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Resistance:\u003c\/strong\u003e \u0026gt; 1 MΩ\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Load Capacitance:\u003c\/strong\u003e 100 nF\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eA\/D Converter:\u003c\/strong\u003e 12-bit with ± 1 LSB inaccuracy\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAbsolute Max. Input Signal:\u003c\/strong\u003e ± 36 V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCrosstalk Between Channels:\u003c\/strong\u003e \u0026gt; 60 dB\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExternal Voltage Read Back:\u003c\/strong\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRange:\u003c\/strong\u003e 0-4.1 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Resistance:\u003c\/strong\u003e Typically 1 MΩ\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKey Coding:\u003c\/strong\u003e Utilizes key coding for module and chassis connectors, ensuring proper integration.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003ePhysical Specifications:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 4 TE, 3 HE (4 HP, 3U)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 0.2 kg\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eThe SAI-1620m module is a reliable and safe solution for high-density analog input needs in safety-critical systems, equipped with comprehensive self-test functionality to ensure continuous monitoring and system integrity.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":49147195654426,"sku":"FC-SAI-1620M","price":78.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/FC-SAI-1620m_1.jpg?v=1718091631"},{"product_id":"fc-tsdi-1624-honeywell-safe-digital-input-fta","title":"FC-TSDI-1624  Honeywell - Safe digital input FTA","description":"\u003cp\u003e\u003cstrong\u003eTSDI-1624 Safe Digital Input FTA (24 V DC, 16 Channels)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOverview:\u003c\/strong\u003e The TSDI-1624 module is a field termination assembly (FTA) designed for safe digital input conversion in industrial control systems. It serves as an interface between the system interconnection cable (SICC-0001\/Lx) and external field wiring via screw terminals.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInterface Compatibility:\u003c\/strong\u003e Connects with a redundant pair of SDI-1624 modules.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHazardous Locations:\u003c\/strong\u003e Suitable for use in 'Class I, Division 2 Hazardous Locations'.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShort Circuit Protection:\u003c\/strong\u003e Includes a Positive Temperature Coefficient (PTC) resistor to handle short circuits to 0 Volt, preventing loss of all 16 channels in case of a single short circuit.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eTechnical Data:\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eGeneral:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eType Numbers:\u003c\/strong\u003e FS-TSDI-1624, FC-TSDI-1624\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals:\u003c\/strong\u003e CE, TUV, UL, CSA, FM\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eInput:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Input Channels:\u003c\/strong\u003e 16\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Voltage:\u003c\/strong\u003e 24 V DC, -15% to +30%\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Current:\u003c\/strong\u003e ≤ 15mA at 24 V DC (with a redundant pair of SDI-1624 modules as load)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePTC Resistance:\u003c\/strong\u003e 260Ω ±25% at 25°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePTC (Steady) Current:\u003c\/strong\u003e Typically 45 mA ±35% at 24 V DC\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003ePhysical:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Dimensions:\u003c\/strong\u003e 90 × 70 × 58 mm (3.54 × 2.76 × 2.28 in)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDIN EN Rails:\u003c\/strong\u003e TS32 \/ TS35 × 7.5\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUsed Rail Length:\u003c\/strong\u003e 91 mm (3.58 in)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 0.2 kg\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eTermination:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eScrew Terminals:\u003c\/strong\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax. Wire Diameter:\u003c\/strong\u003e 2.5 mm² (AWG 14)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStrip Length:\u003c\/strong\u003e 7 mm (0.28 in)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTightening Torque:\u003c\/strong\u003e 0.5 Nm (0.37 ft-lb)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003eThe TSDI-1624 is a versatile FTA module offering 16 channels for safe digital input conversion, compatible with hazardous locations and featuring robust short circuit protection.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":49147281408282,"sku":"FC-TSDI-1624","price":110.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/FC-TSDI-1624_2.jpg?v=1718092138"},{"product_id":"power-distribution-board-fc-pdb-0824p-honeywell","title":"Power Distribution Board FC-PDB-0824P Honeywell","description":"\u003cp\u003e\u003cstrong\u003ePDB-0824P Power Distribution Board (24 V DC, 2 A, 8 Channels)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOverview:\u003c\/strong\u003e The PDB-0824P power distribution board is designed to efficiently distribute 24 V DC from the main power rail to individual 24 V DC devices within a cabinet enclosure, such as fan units and FTAs.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle 24 V DC Entry Connector:\u003c\/strong\u003e Connects to the main bus bar for power input.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEight Fused 24 V DC Field Connectors:\u003c\/strong\u003e Distributes power to up to eight 24 V DC devices, each with a 2 A fuse.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Distribution Cable:\u003c\/strong\u003e Utilizes the 24 V DC power distribution cable (refer to datasheet PDC-MB24-y) for connecting the main power bar to the In connector.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eTechnical Data:\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eGeneral:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eType Number:\u003c\/strong\u003e FC-PDB-0824P\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals:\u003c\/strong\u003e CE; UL, TUV, CSA pending\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eFuse:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRating:\u003c\/strong\u003e 2 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 5x20 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Rating AC:\u003c\/strong\u003e 250 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Rating DC:\u003c\/strong\u003e 300 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Schurter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer Part Number:\u003c\/strong\u003e 0001.2507\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDerating Curve:\u003c\/strong\u003e Linear from 2 A at 25°C to 1.4 A at 70°C module ambient\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eConnectors:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIn (Power Input):\u003c\/strong\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e 2 pole header with keying\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMake and Type:\u003c\/strong\u003e Weidmuller BVZ 7.62HP\/02F SN (connector), Weidmuller BV\/SV7.62HP KO (keys)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField (Power Output):\u003c\/strong\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e 2 pole socket block\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMake and Type:\u003c\/strong\u003e Weidmuller BLZ 5.08\/2F SN SW\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003ePhysical:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 94 x 109 x 71 mm (3.7 x 4.3 x 2.8 in)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDIN EN Rails:\u003c\/strong\u003e TS32 \/ TS35 × 7.5\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUsed Rail Length:\u003c\/strong\u003e 95 mm (3.74 in)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 0.2 kg\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eThe PDB-0824P is an essential component for reliable and efficient power distribution in industrial control systems, ensuring secure connections and consistent power delivery to multiple devices.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":49147372044570,"sku":"FC-PDB-0824P","price":140.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/FC-PDB-0824P_1_e2b6d5bf-2229-4d77-aef8-db3125bcb3d5.jpg?v=1718093271"},{"product_id":"fc-rusio-3224-universal-safe-io-module-honeywell","title":"FC-RUSIO-3224 Universal Safe IO Module Honeywell","description":"\u003ch2\u003e\u003cstrong\u003eFC-RUSIO-3224 Universal Safe IO Device\u003c\/strong\u003e\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eOverview:\u003c\/strong\u003e The FC-RUSIO-3224 module is a universal safe IO device featuring 32 channels operating at 24 V DC, configurable for various functions through Safety Builder. It complies with SIL 3 safety requirements according to IEC 61508\/61511 standards, making it ideal for critical applications.\u003c\/p\u003e\u003ch3\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eUniversal IO Channels:\u003c\/strong\u003e 32 configurable channels for digital input, digital output, analog input, or analog output.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRedundant Configuration:\u003c\/strong\u003e Requires two modules for redundancy, ensuring reliability.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEthernet Communication:\u003c\/strong\u003e Supports two 100Mbaud Ethernet links for communication with a Safety Manager Controller.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePatented Design:\u003c\/strong\u003e Uses Honeywell’s patented Series C design, mountable on an IO Termination Assembly (IOTA).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSIL 3 Compliance:\u003c\/strong\u003e Adheres to SIL 3 safety requirements with a proven-in-use redundant processor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eESD Functionality:\u003c\/strong\u003e Configurable ESD function via channel 32 for dedicated safety-related functions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWatchdog Function:\u003c\/strong\u003e Monitors cycle time, supply voltage, handles ESD function, and memory errors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLED Indicators:\u003c\/strong\u003e Front-facing LEDs indicate power and health status.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReal-Time Clock:\u003c\/strong\u003e Provides Sequence Of Event (SOE) time stamping with 1 msec resolution.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003e\u003cstrong\u003eFunctionality:\u003c\/strong\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eExecutes input scan of process variables and hardware functional tests.\u003c\/li\u003e\n\u003cli\u003eFacilitates data exchange with partner module and Safety Manager Controller.\u003c\/li\u003e\n\u003cli\u003eControls outputs and updates the process.\u003c\/li\u003e\n\u003cli\u003eFunctions as part of the Safety Manager universal IO module within the Safety Manager concept.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eOperating Conditions:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutside Module Temperature:\u003c\/strong\u003e -40°C to +70°C (-40°F to +158°F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInside Module Temperature:\u003c\/strong\u003e -40°C to +90°C (-40°F to +194°F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e -40°C to +85°C (-40°F to +185°F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRelative Humidity:\u003c\/strong\u003e 10% to 95% (non-condensing)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePollution:\u003c\/strong\u003e Pollution degree 2 or better\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals:\u003c\/strong\u003e CE, UL, TÜV\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003ePower:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupply Voltage:\u003c\/strong\u003e 24 V DC (-15% to +30%)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupply Current:\u003c\/strong\u003e Max 300 mA (without field load)\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eIO Channels:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e32 channels, configurable as digital input, ESD input, analog input, digital output, with or without line monitoring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Combined Load:\u003c\/strong\u003e 9 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Field Capacitance:\u003c\/strong\u003e 100 nF (for AI\/DI\/AO channels), 1 μF (for DO channels)\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003ePhysical Specifications:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 145 x 165.1 x 72.4 mm (H x W x D)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 0.66 kg (1.45 lbs)\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eThe FC-RUSIO-3224 offers a robust and flexible solution for universal IO applications in safety-critical environments, ensuring reliability and compliance with international safety standards.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":49147485618458,"sku":"FC-RUSIO-3224","price":140.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/FC-RUSIO-3224_6.jpg?v=1718094595"},{"product_id":"honeywell-digital-input-module-fc-sdi-1624","title":"Honeywell - Digital Input Module FC-SDI-1624","description":"\u003cp\u003e\u003cstrong\u003eSDI-1624 Safe Digital Input Module\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOverview:\u003c\/strong\u003e The SDI-1624 safe digital input module is designed to provide reliable digital input signals for safety-critical applications. It incorporates advanced fail-safe features and self-testing functionalities to ensure continuous monitoring and integrity of the system.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFail-to-Safe Input Stage:\u003c\/strong\u003e In the event of a component failure, the input signal to the processor is de-energized, ensuring the system defaults to a safe condition.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSelf-Test Functions:\u003c\/strong\u003e The remaining logic circuitry undergoes self-tests within the configured Diagnostic Test Interval, continuously monitoring system integrity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiagnostic Tests:\u003c\/strong\u003e Tests include the ability to receive logic level '0' and '1' signals and checking for crosstalk between inputs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Limited Output:\u003c\/strong\u003e The 24V DC out pin serves as a current-limited output for energizing redundant inputs via a field contact.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eType Numbers:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eFS-SDI-1624\u003c\/li\u003e\n\u003cli\u003eFC-SDI-1624\u003c\/li\u003e\n\u003cli\u003eComplies with international standards for safety and quality.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eApprovals:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003eCE, TUV, UL, CSA, FM, ensuring compliance with regulatory requirements.\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eSpace Requirements:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e4 TE, 3 HE (= 4 HP, 3U), providing compact dimensions for efficient installation.\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003ePower Requirements:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e5V DC:\u003c\/strong\u003e 8 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e24V DC Internal:\u003c\/strong\u003e 110 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e24V DC External (Input Currents):\u003c\/strong\u003e 110 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRipple Content:\u003c\/strong\u003e \u0026lt; 0.5 Vp-p (0-360 Hz) on 5V DC, ensuring stable power supply.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eInput:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Channels:\u003c\/strong\u003e 16\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Input Voltage:\u003c\/strong\u003e 36V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Current:\u003c\/strong\u003e 7 mA at 24V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Load Capacitance:\u003c\/strong\u003e 100 nF\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput HIGH:\u003c\/strong\u003e \u0026gt; 15V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput LOW:\u003c\/strong\u003e \u0026lt; 9V DC (I \u0026lt; 2 mA)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Delay:\u003c\/strong\u003e Typically 10 ms\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eOutput:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e 24V DC solid state, short circuit proof\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Current:\u003c\/strong\u003e 450 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax. Load Capacitance:\u003c\/strong\u003e 32 µF\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Drop:\u003c\/strong\u003e \u0026lt; 1.5V at 450 mA\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eKey Coding:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003eUtilizes key coding for module and chassis connectors, ensuring proper integration.\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e0.2 kg\u003c\/li\u003e\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":49147538899226,"sku":"FC-SDI-1624","price":130.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/FC-SDI-1624_2_4cab848d-8180-4f6f-87ef-89d287d9f2be.jpg?v=1718095168"},{"product_id":"fc-tpsu-2430-honeywell-dc-dc-converter-module","title":"FC-TPSU-2430  Honeywell DC\/DC Converter Module","description":"\u003cp\u003e\u003cstrong\u003eTPSU-2430 DC\/DC Converter Module\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOverview:\u003c\/strong\u003e The TPSU-2430 is a high-efficiency DC\/DC converter designed to deliver an isolated 30V DC \/ 1A output to field termination assemblies (FTAs) such as the TSAI-1620m and TSHART-1620m. This module includes voltage monitoring with LED indication and alarm functions via a read-back relay contact, ensuring reliable and safe operation.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolated Output:\u003c\/strong\u003e Provides a stable 30V DC \/ 1A output.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Monitoring:\u003c\/strong\u003e LED indication for real-time voltage status.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAlarm Functions:\u003c\/strong\u003e Equipped with overvoltage protection and undervoltage detection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Compliance:\u003c\/strong\u003e Meets SIL3 safety class requirements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlexible Mounting:\u003c\/strong\u003e Suitable for horizontal or vertical installation on DIN rails.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eType Numbers:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eFS-TPSU-2430\u003c\/li\u003e\n\u003cli\u003eFC-TPSU-2430\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eApprovals:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003eCE, TUV, UL, CSA, FM\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eInput:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNominal Voltage:\u003c\/strong\u003e 24V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Range:\u003c\/strong\u003e 18–36V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInrush Current:\u003c\/strong\u003e ≤ 4A\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eOutput:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage:\u003c\/strong\u003e 30V DC (± 0.25V)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent:\u003c\/strong\u003e 1A (short-circuit proof)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRipple:\u003c\/strong\u003e \u0026lt; 0.1 Vrms (0—30 MHz)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRegulation:\u003c\/strong\u003e \u0026lt; 1% (load + line)\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003ePhysical:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 150 × 70 × 62.3 mm (L × W × H)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 3 kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDIN EN Rails:\u003c\/strong\u003e TS32 \/ TS35 × 7.5\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFuse Rating:\u003c\/strong\u003e 3.15A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFuse Dimensions:\u003c\/strong\u003e 5x20 mm\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Schurter\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer PN:\u003c\/strong\u003e 0001.2509\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTermination:\u003c\/strong\u003e Screw terminals, max. wire size 2.5 mm² (AWG 14), strip length 7 mm, tightening torque 0.5 Nm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring Classification:\u003c\/strong\u003e 80°C min.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eIsolation Voltage:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput to Output:\u003c\/strong\u003e 2000V AC (1 min.)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput to Relay Contact:\u003c\/strong\u003e 2000V AC (1 min.)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput to Relay Contact:\u003c\/strong\u003e 2000V AC (1 min.)\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eEnvironmental:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -5°C – +70°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e -40°C – +85°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCooling:\u003c\/strong\u003e Natural convection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAltitude:\u003c\/strong\u003e ≤2000m\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eAlarm Functions:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOvervoltage Protection:\u003c\/strong\u003e Dual, two-fault-tolerant\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUndervoltage Detector:\u003c\/strong\u003e LED indicates voltage status; read-back relay contact closes if voltage is OK\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eMounting:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003eDIN rail mounted, suitable for horizontal or vertical installation\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eReadback Relay Contact Rating:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e36V DC \/ 40 mA\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e30V AC \/ 40 mA\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":49148605661466,"sku":"FC-TPSU-2430","price":120.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/FC-TPSU-2430_3.jpg?v=1718096599"},{"product_id":"fc-cpchas-0001-honeywell-controller-chassis","title":"FC-CPCHAS-0001 Honeywell Controller Chassis","description":"\u003cp\u003e\u003cstrong\u003eCPCHAS-0001 Chassis for Redundant or Non-Redundant Controller (Safety Manager)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOverview:\u003c\/strong\u003e The CPCHAS-0001 Controller chassis is designed to house Control Processor modules for Safety Manager systems. It is typically positioned at the top of the cabinet, with IO chassis below it. The chassis ensures organized placement and secure operation of the Control Processor modules, essential for maintaining system reliability and safety.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eController Housing:\u003c\/strong\u003e 19\" open-front housing with a magnetically locked back cover plate.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Installation:\u003c\/strong\u003e Front insertion with module guides and quarter-turn fasteners for secure placement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Management:\u003c\/strong\u003e Three horizontal bars at the back for tie-wrapping cables:\n\u003cul\u003e\n\u003cli\u003eTop bar: 24V-supply and 24V-signal wires\/cables.\u003c\/li\u003e\n\u003cli\u003eMiddle bar: Communication cables.\u003c\/li\u003e\n\u003cli\u003eBottom bar: 5V and Watchdog cables (WdPx and 5V-x).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane Connectivity:\u003c\/strong\u003e Front connectors for Control Processor modules and back connectors for signal input\/output. Keying pins ensure grounding.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eGeneral:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eType Number:\u003c\/strong\u003e FS-CPCHAS-0001\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals:\u003c\/strong\u003e CE, UL, CSA, TUV, FM\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003ePower Consumption:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e5V-1:\u003c\/strong\u003e 0.05 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e5V-2:\u003c\/strong\u003e 0.05 A\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight:\u003c\/strong\u003e 4 HE (177 mm, 7 in)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth:\u003c\/strong\u003e 482.6 mm (19 in)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDepth:\u003c\/strong\u003e 280 mm (11 in)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 5.8 kg (12.8 lb)\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eThe CPCHAS-0001 chassis is a robust and well-designed solution for housing Control Processor modules in Safety Manager systems, ensuring secure installation and effective cable management.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":49150014161178,"sku":"FC-CPCHAS-0001","price":80.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/FC-CPCHAS-0001.jpg?v=1718100551"},{"product_id":"10310-2-1-earth-leakage-detector-eld-honeywell","title":"10310\/2\/1 Earth Leakage Detector (ELD) Honeywell","description":"\u003cp\u003e\u003cstrong\u003e10310\/2\/1 Earth Leakage Detector (ELD)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOverview:\u003c\/strong\u003e The 10310\/2\/1 module is an Earth Leakage Detector (ELD) designed for monitoring and detecting earth faults in 24 V DC systems. It features a manual self-test function and earth connection monitoring for ensuring system integrity and safety.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEarth Leakage Detection:\u003c\/strong\u003e Capable of monitoring earth faults in 24 V DC, 48 V DC, 60 V DC, or 110 V DC systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEarth Connection Monitoring:\u003c\/strong\u003e Offers continuous or intermittent monitoring of the earth connection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSelf-Test Functionality:\u003c\/strong\u003e Can be manually activated or triggered via input signals (Rst24, Rst110).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReset Options:\u003c\/strong\u003e Supports manual resetting or high-level signal application to Rst24 or Rst110 inputs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest Capability:\u003c\/strong\u003e Tests the module and earth connection using a 1.5 kOhm resistor or a resistor connected to the Earth2 pin.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLED Indicator:\u003c\/strong\u003e Displays the selected connection frequency when operating in intermittent mode.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePower:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupply Voltage:\u003c\/strong\u003e 24 V DC (max. 30 V DC)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupply Current:\u003c\/strong\u003e Max. 60 mA\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eInput Voltage:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRst24:\u003c\/strong\u003e 18 to 70 V DC\n\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eInput Current:\u003c\/strong\u003e 1.1 mA at 24 V DC\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRst110:\u003c\/strong\u003e 40 to 130 V DC\n\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eInput Current:\u003c\/strong\u003e 2.5 mA at 110 V DC\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eEarth:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEarth Voltage:\u003c\/strong\u003e -12 V DC (no earth fault)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEarth Fault Threshold:\u003c\/strong\u003e -30 to +125 V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax. Earth Current:\u003c\/strong\u003e\u003cul\u003e\n\u003cli\u003e5.5 mA (± 1 mA)\u003c\/li\u003e\n\u003cli\u003e25.0 mA (± 5 mA)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eOutput Contact:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax. Output Voltage:\u003c\/strong\u003e 115 V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax. Output Current:\u003c\/strong\u003e 2 A\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eRelay Contacts:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInitial Contact Resistance:\u003c\/strong\u003e 30 mOhm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax. Current:\u003c\/strong\u003e 5A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax. Switched Voltage:\u003c\/strong\u003e 250 V DC \/ 250 V AC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax. Switched Load:\u003c\/strong\u003e 100 W \/ 1000 VA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExpected Electrical Life:\u003c\/strong\u003e 100,000 switch operations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExpected Mechanical Life:\u003c\/strong\u003e 200,000,000 switch operations\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eInstallation:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Code:\u003c\/strong\u003e Holes A5, A11\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRack Code:\u003c\/strong\u003e Large pins A5, A11\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 0.2 kg\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003eThe 10310\/2\/1 ELD offers robust earth fault detection and monitoring capabilities, providing critical safety functions for various DC systems.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":49150159651098,"sku":"10310\/2\/1","price":140.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/10310-2-1.jpg?v=1718100990"},{"product_id":"honeywell-termination-module-10313-1-1","title":"Honeywell Termination Module 10313\/1\/1","description":"\u003ch2\u003e\n\u003cstrong\u003e10313\/1\/1 Module: FSC System Power Distribution and Watchdog Signal Unit\u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\n\u003c\/h2\u003e\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e\u003cstrong style=\"color: #2e86c1;\"\u003e10313\/1\/1\u003c\/strong\u003e 207011\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e Power Distribution Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals:\u003c\/strong\u003e CE, TÜV (UL pending)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax Current Faston Pin:\u003c\/strong\u003e 4A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMax Current I\/O Pin:\u003c\/strong\u003e 2A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 240x87x60 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 0.3 kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRail Type:\u003c\/strong\u003e TS32 \/ TS35 x 7.5\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRail Length:\u003c\/strong\u003e 241 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage:\u003c\/strong\u003e 5V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temp:\u003c\/strong\u003e 0°C to 60°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temp:\u003c\/strong\u003e -40°C to 85°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity:\u003c\/strong\u003e 5-95% non-condensing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVibration:\u003c\/strong\u003e 2g @ 10-500Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShock:\u003c\/strong\u003e 15g peak\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC:\u003c\/strong\u003e 10V\/m immunity\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003e\u003cstrong\u003ePackage \u0026amp; Shipping\u003c\/strong\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eIncludes one \u003cstrong style=\"color: #2e86c1;\"\u003e10313\/1\/1\u003c\/strong\u003e module\u003c\/li\u003e\n\u003cli\u003eMounting hardware included\u003c\/li\u003e\n\u003cli\u003eInstallation guide provided\u003c\/li\u003e\n\u003cli\u003e12-month warranty\u003c\/li\u003e\n\u003cli\u003eShipping via FedEx, UPS, or DHL\u003c\/li\u003e\n\u003cli\u003eExpress delivery available\u003c\/li\u003e\n\u003cli\u003eWorldwide shipping support\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eQ: What is the maximum power capacity?\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eA: 4A per Faston pin, 2A per I\/O pin\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eQ: Does it support redundant systems?\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eA: Yes, both redundant and non-redundant\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eQ: What is the operating voltage?\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eA: 5V DC power distribution\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eQ: Can I connect multiple cabinets?\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eA: Yes, with additional linking connectors\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eQ: What safety approvals does it have?\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eA: CE and TÜV certified, UL pending\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003e\u003cstrong\u003eCompatibility Information\u003c\/strong\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eWorks with FSC101 and FSC102 systems\u003c\/li\u003e\n\u003cli\u003eCompatible with 10315\/1\/1 backplanes\u003c\/li\u003e\n\u003cli\u003eSupports 10314\/1\/1 backplanes\u003c\/li\u003e\n\u003cli\u003eIntegrates with watchdog repeaters\u003c\/li\u003e\n\u003cli\u003eWorks with horizontal bus systems\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":49150382113050,"sku":"10313\/1\/1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/Honeywell10313-1-1FSC_JPG.jpg?v=1718101787"},{"product_id":"10302-2-1-honeywell-watchdog-repeater-module","title":"10302\/2\/1 Honeywell Watchdog repeater Module","description":"\u003cp\u003e\u003cstrong\u003e10302\/2\/1 Watchdog Repeater\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOverview:\u003c\/strong\u003e The 10302\/2\/1 Watchdog Repeater is designed to monitor 5 Vdc and 24 Vdc power supplies and is integral for connecting to output modules for monitoring purposes in diverse system setups.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eMonitors 5 Vdc and 24 Vdc power supplies for system reliability.\u003c\/li\u003e\n\u003cli\u003eConnects to output modules to monitor their power supply status.\u003c\/li\u003e\n\u003cli\u003eEssential in multiple-PSU configurations, certain power supply types, setups with redundant and non-redundant I\/O, and configurations with redundant Central Parts and non-redundant I\/O with safety-related output modules.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eInstallation:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eRequires horizontal bus connection in I\/O racks.\u003c\/li\u003e\n\u003cli\u003ePositioning must align with the output modules it monitors.\u003c\/li\u003e\n\u003cli\u003ePlacement within the same I\/O section as the monitored output modules.\u003c\/li\u003e\n\u003cli\u003eInstallation specifics outlined in I\/O backplane datasheets.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eExchange:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003eCan be exchanged with the power supply switched on, with potential Central Part shutdown in specific configurations.\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eGeneral:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eType Number:\u003c\/strong\u003e 10302\/2\/1 12600\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals:\u003c\/strong\u003e CE, TUV, UL\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSoftware Versions:\u003c\/strong\u003e ≥ 3.00\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpace Requirements:\u003c\/strong\u003e TE, 3 HE (= 4 HP, 3U)\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003ePower:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003ePower Requirements:\u003c\/strong\u003e\u003cul\u003e\n\u003cli\u003eVdc: 35 mA (without WDROUT output current)\u003c\/li\u003e\n\u003cli\u003e24 Vdc: 25 mA\u003c\/li\u003e\n\u003cli\u003eWDG1 + WDG2 input current: 0.1 mA\u003c\/li\u003e\n\u003cli\u003eWDR OUT Max. output current: 900 mA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eKey Coding:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Code:\u003c\/strong\u003e Holes: A5, A9\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRack Code:\u003c\/strong\u003e Large pins: A5, A9\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e0.3 kg\u003c\/li\u003e\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":49150394401050,"sku":"10302\/2\/1","price":120.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/10302-2-1HoneywellFSC_JPG.jpg?v=1718104722"},{"product_id":"fc-sao-0220m-honeywell-safe-analog-output-module","title":"FC-SAO-0220M Honeywell - Safe Analog Output Module","description":"\u003cp\u003e\u003cstrong\u003eSAO-0220m Safe Analog Output Module\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOverview:\u003c\/strong\u003e The SAO-0220m safe analog output module furnishes two channels of 0(4)-20 mA output, catering to analog control requirements. It boasts galvanic isolation from the 24 V DC and 5 V DC supplies for enhanced safety.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Channels:\u003c\/strong\u003e Two channels of 0(4)-20 mA output, compatible with resistive or capacitive loads.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGalvanic Isolation:\u003c\/strong\u003e Ensures outputs are insulated from supply voltages, guaranteeing safety and preventing interference.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSecondary Means of De-energizing (SMOD):\u003c\/strong\u003e Each output incorporates a secondary means of de-energizing, enabling independent deactivation by the watchdog and processor irrespective of application status.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiagnostic Testing:\u003c\/strong\u003e Regular testing of analog outputs for correct output value, de-energization capability, and crosstalk between channels.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eType Numbers:\u003c\/strong\u003e FS-SAO-0220m, FC-SAO-0220m, compliant with international safety standards.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals:\u003c\/strong\u003e CE, TUV, UL, CSA, FM, indicating compliance with regulatory requirements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpace Requirements:\u003c\/strong\u003e 4 TE, 3 HE (= 4 HP, 3U), providing a compact installation footprint.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003ePower Requirements:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e5V DC:\u003c\/strong\u003e 30 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e24V DC:\u003c\/strong\u003e 65 mA +30 mA for each active output\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eOutput:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Channels:\u003c\/strong\u003e 2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Specification:\u003c\/strong\u003e Active or passive, 0-20 \/ 4-20 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eD\/A Converter:\u003c\/strong\u003e 12-bit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOff Current:\u003c\/strong\u003e \u0026lt; 0.05 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Load Capacitance:\u003c\/strong\u003e 100 nF\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoop Powering (Active):\u003c\/strong\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Loop Resistance:\u003c\/strong\u003e 600 Ω\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Output Voltage:\u003c\/strong\u003e 30 V DC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExternal Powering (Passive):\u003c\/strong\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Voltage:\u003c\/strong\u003e 40 V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMinimum Voltage Drop:\u003c\/strong\u003e ≤ 7.5 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWDG Input Current:\u003c\/strong\u003e 0.5 mA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":49150427922714,"sku":"FC-SAO-0220M","price":130.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/FC-SDO-0824_1.jpg?v=1718105283"},{"product_id":"fc-teld-0001-earth-leakage-detector-honeywell","title":"FC-TELD-0001 Earth Leakage Detector Honeywell","description":"\u003cp\u003e\u003cstrong\u003eFC-TELD-0001 Earth Leakage Detector Terminal (TELD)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOverview:\u003c\/strong\u003e The FC-TELD-0001 is an Earth Fault Monitor engineered to identify earth faults within connected circuits in a power supply group. It elevates earth voltage to approximately +4Vdc, relative to the monitored power supply group's 0Vdc. The drawn current (0-20mA) offers insights into the nature of the earth fault present. In normal conditions, it consumes around 10mA, varying in the presence of an earth fault based on its magnitude and polarity. The module can be deactivated by the control system, isolating it from the earth pin and effectively eliminating the earth fault current.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eTechnical Data:\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eGeneral:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eType Number:\u003c\/strong\u003e FC-TELD-0001\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature:\u003c\/strong\u003e -40°C to +75°C (-40°F to +167°F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals:\u003c\/strong\u003e CE, TUV\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhysical Module Dimensions:\u003c\/strong\u003e\u003cul\u003e\n\u003cli\u003e80 x 20 x 70 mm (L x W x H)\u003c\/li\u003e\n\u003cli\u003eDIN EN Rails: TS32 \/ TS35 x 7.5\u003c\/li\u003e\n\u003cli\u003eUsed Rail Length: 21 mm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eAnalog:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Voltage:\u003c\/strong\u003e 24 VDC +30\/-15% (with ~250 Ohm series impedance)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Current:\u003c\/strong\u003e 10 mA (no earth fault present), max 25 mA (limited by power source)\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eEarth:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage:\u003c\/strong\u003e Typically +4.1 VDC (referenced to monitored 0 V)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResistor (R):\u003c\/strong\u003e ~2.8 kOhm\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eEarth Fault Detection:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eThreshold:\u003c\/strong\u003e ~0.6 mA (flowing into FC-TELD-0001), ~0.2 mA (coming from FC-TELD-0001)\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eTermination:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eScrew Terminals:\u003c\/strong\u003e Wire size 0.2 mm2 - 4 mm2 (solid), 0.2 mm2 - 2.5mm2 (stranded), strip length 8 mm\u003c\/li\u003e\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":49150462755098,"sku":"FC-TELD-0001","price":130.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/FC-TSAI-1620M_3_bba05529-b9e6-426e-adae-99cd6846ed42.jpg?v=1718106176"},{"product_id":"fc-mcar-02-honeywell-sm-rio-carrier","title":"FC-MCAR-02 Honeywell SM RIO Carrier","description":"\u003cp\u003e\u003cstrong\u003eFC-MCAR-02: Carrier for Two IOTA-R24 Assemblies\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOverview:\u003c\/strong\u003e The FC-MCAR-02 is a carrier designed to accommodate two IOTA-R24 assemblies, offering structural support and electrical connections. It consists of a Cable Carrier Assembly (CCA), metal profile, plastic cover plates, ground rail with 32 ground connection screws, and two power rails with M5 holes for +24V and 0V.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eComponents:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eCable Carrier Assembly (CCA)\u003c\/li\u003e\n\u003cli\u003eMetal Profile\u003c\/li\u003e\n\u003cli\u003eTwo Plastic Cover Plates\u003c\/li\u003e\n\u003cli\u003eGround Rail with 32 Ground Connection Screws\u003c\/li\u003e\n\u003cli\u003eTwo Power Rails with M5 Holes for +24V and 0V\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eMounting:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eFour Mounting Holes suitable for screws with a diameter \u0026lt;5.5 mm.\u003c\/li\u003e\n\u003cli\u003ePower rails of two MCAR-02 carriers can be coupled by using two M5 screws to connect the power rails of the top and bottom carriers through 5 mm holes.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eFunctionality:\u003c\/strong\u003e Provides structural support and electrical connections for two IOTA-R24 assemblies.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDimensions and Appearance:\u003c\/strong\u003e Physical appearance depicted in the figure with coordinates for the mounting holes.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eTechnical Data:\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eGeneral:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eType Number:\u003c\/strong\u003e FC-MCAR-02\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -40°C to +70°C (-40°F to +158°F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e -40°C to +85°C (-40°F to +185°F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRelative Humidity:\u003c\/strong\u003e 10% to 95% (non-condensing)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePollution:\u003c\/strong\u003e Pollution Degree 2 or better\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals:\u003c\/strong\u003e CE; UL\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003ePower:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupply Voltage:\u003c\/strong\u003e 24 V DC, ranging from -15% to +30%\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupply Current:\u003c\/strong\u003e None\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupply Rail Current:\u003c\/strong\u003e Maximum 40 A\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eConnections:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e24V Supply:\u003c\/strong\u003e 2 x M5\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e2 x 5mm Holes for Coupling of Carriers\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGround:\u003c\/strong\u003e 32 x M5\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003ePhysical Data:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (H x W x D):\u003c\/strong\u003e 105.4 x 222.3 x 931.8 mm \/ 4.15 x 8.75 x 36.7 in\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 6.1 kg \/ 13.4 lbs\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":49150498144538,"sku":"FC-MCAR-02","price":180.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/FC-MCAR-02.jpg?v=1718106365"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/collections\/Honeywell.jpg?v=1717143964","url":"https:\/\/www.ubestplc.com\/collections\/honeywell.oembed?page=23","provider":"Ubest Automation Limited","version":"1.0","type":"link"}