{"title":"Triconex","description":"\u003cp\u003eTriconex industrial automation modules are critical components of redundant fault-tolerant systems used in safety-critical applications. They ensure continued safe operation even in the event of a single module failure. Triconex modules include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.ubestplc.com\/collections\/tricon-power-modules\"\u003e\u003cstrong\u003eTriconex Power Supply Modules\u003c\/strong\u003e\u003c\/a\u003e: Provide power to the Triconex system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.ubestplc.com\/collections\/main-processor-module\"\u003e\u003cstrong\u003eMain Processor Modules\u003c\/strong\u003e\u003c\/a\u003e: Execute the safety logic of the Triconex system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.ubestplc.com\/collections\/triconex-input-module\"\u003e\u003cstrong\u003eInput Modules \u0026amp; Output Modules\u003c\/strong\u003e\u003c\/a\u003e: Receive signals from field devices.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.ubestplc.com\/collections\/triconex-cables\"\u003e\u003cstrong\u003eTCM Cables\u003c\/strong\u003e\u003c\/a\u003e: Used to connect Triconex modules.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"collection-hero__title\"\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/www.ubestplc.com\/collections\/triconex-chasis\" title=\"Triconex Chasis\"\u003eTriconex Chasis\u003c\/a\u003e\u003ca href=\"https:\/\/www.ubestplc.com\/collections\/triconex-chasis\"\u003e: \u003c\/a\u003e\u003c\/strong\u003eA Triconex chassis is a rack-mounted enclosure that houses Triconex safety logic solvers, I\/O modules, and other system components.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/www.ubestplc.com\/collections\/triconex-other-series\"\u003eOther Series\u003c\/a\u003e\u003c\/strong\u003e: Includes communication modules, diagnostic modules, and I\/O subsystems among other modules.\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!----\u003e","products":[{"product_id":"triconex-3006-main-processor-module","title":"Triconex 3006 Main Processor Module","description":"\u003cp\u003e\u003cstrong\u003eTriconex 3006 Main Processor Module\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e The Triconex 3006 Main Processor Module is an integral component of the Triconex T3000 safety instrumented system (SIS). It is designed to provide high reliability and robust performance for critical control applications in various industries such as nuclear power, oil refining, petrochemical, and chemical processing.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcessor:\u003c\/strong\u003e Utilizes a Motorola 68040 CPU, ensuring efficient processing capabilities.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMemory:\u003c\/strong\u003e Equipped with 2MB SRAM for adequate storage and quick data access.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnectivity:\u003c\/strong\u003e Includes 2 serial ports and 1 Ethernet port for versatile communication options.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Integrity Protection:\u003c\/strong\u003e Features built-in diagnostics and High Integrity Pressure Protection System (HIPPS) for enhanced safety.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiagnostic Capabilities:\u003c\/strong\u003e The module offers optically isolated RS-232 interfaces for diagnostic analysis.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBus Speed:\u003c\/strong\u003e 33 MHz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eI\/O Ports:\u003c\/strong\u003e 2 serial ports, 1 Ethernet port\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 15 x 11 x 4 cm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e 0 to 60 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e -40 to 85 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 4 kg\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e The Triconex 3006 is widely used in safety-critical control systems to ensure safe operation and protection against hazardous conditions. It supports systems like fire and gas protection, burner management, turbine control, and key process control.\u003c\/p\u003e","brand":"Triconex","offers":[{"title":"Default Title","offer_id":49059935748378,"sku":"3006","price":900.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/3008_2_9f682dba-ca65-46b1-b245-99b1112d5341.jpg?v=1717154083"},{"product_id":"mp3101-invensys-triconex-main-processor","title":"MP3101 Invensys Triconex Main Processor","description":"\u003cp\u003e\u003cstrong\u003eInvensys Triconex MP3101 TMR Main Processor\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e The Invensys Triconex MP3101 TMR Main Processor is a crucial component of the Triconex safety instrumented system (SIS). It utilizes triple-modular redundancy (TMR) technology to ensure high reliability and safety for critical industrial applications such as nuclear power plants, chemical plants, and oil and gas facilities. This processor module is designed to meet stringent safety standards and provide fault-tolerant operation in demanding environments.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTriple-Modular Redundant (TMR) Architecture:\u003c\/strong\u003e Ensures high reliability by employing three parallel processors that continuously check each other to detect and correct faults.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Performance:\u003c\/strong\u003e Equipped with dual PowerPC 750FX processors to handle complex computations and control tasks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMemory Capacity:\u003c\/strong\u003e Features 512 MB of RAM and 2 MB of non-volatile RAM for robust performance and data retention.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication:\u003c\/strong\u003e Includes dual redundant Ethernet ports and dual redundant RS-485 ports for reliable and versatile connectivity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Robustness:\u003c\/strong\u003e Designed to operate in harsh conditions with a wide operating temperature range and high resistance to vibration and shock.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcessor:\u003c\/strong\u003e Dual PowerPC 750FX processors\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMemory:\u003c\/strong\u003e 512 MB RAM, 2 MB non-volatile RAM\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication Ports:\u003c\/strong\u003e 2x Ethernet, 2x RS-485\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -40 to 70°C (-40 to 158°F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e -40 to 85°C (-40 to 185°F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity:\u003c\/strong\u003e 5 to 95% non-condensing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVibration:\u003c\/strong\u003e 5 to 50 Hz, 0.035 in peak-to-peak\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShock:\u003c\/strong\u003e 15 g, 11 ms half-sine\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertifications:\u003c\/strong\u003e IEC 61508 SIL 3, FM, CSA\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eWeight and Dimensions:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 4 kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 16 cm x 16 cm x 12 cm\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eThe MP3101 TMR Main Processor module ensures the highest level of safety and reliability for critical process control and automation applications. Its advanced features and robust design make it an essential component for maintaining safe and efficient operations in various industrial settings.\u003c\/p\u003e","brand":"Triconex","offers":[{"title":"Default Title","offer_id":49059996205338,"sku":"MP3101","price":700.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/MP3101_1.jpg?v=1717155409"},{"product_id":"triconex-3008-invensys-main-processor-module","title":"Triconex 3008 Invensys Main Processor Module","description":"\u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e The Triconex 3008 Main Processor is a high-performance module designed for critical safety applications in various industrial settings, including process industries, power generation, and manufacturing. It is part of the Triconex safety instrumented system (SIS) and is certified for use up to Safety Integrity Level (SIL) 3 according to IEC 61508 standards. This module ensures reliable and fault-tolerant operation, making it essential for environments requiring stringent safety measures.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcessor:\u003c\/strong\u003e Equipped with a Motorola MPC860, 32-bit, 50 MHz microprocessor, providing robust processing capabilities.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMemory:\u003c\/strong\u003e The module includes 16 MB DRAM (non-battery backed-up), 32 KB SRAM (battery backed-up), and 6 MB Flash PROM, ensuring efficient data handling and storage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication:\u003c\/strong\u003e Features a TriBus communication rate of 25 megabits per second with 32-bit CRC protection and fully isolated 32-bit DMA, along with optically isolated RS-232 interface for diagnostic analysis.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiagnostics:\u003c\/strong\u003e Advanced diagnostics for the health of each MP, I\/O module, and communication channel, supporting hot replacement of errant modules for seamless system operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFunctionality:\u003c\/strong\u003e Implements Sequence of Events (SOE) functionality for precise event logging and time synchronization.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMicroprocessor:\u003c\/strong\u003e Motorola MPC860, 32-bit, 50 MHz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMemory:\u003c\/strong\u003e\u003cul\u003e\n\u003cli\u003e16 MB DRAM (non-battery backed-up)\u003c\/li\u003e\n\u003cli\u003e32 KB SRAM (battery backed-up)\u003c\/li\u003e\n\u003cli\u003e6 MB Flash PROM\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication Rate:\u003c\/strong\u003e 25 megabits per second, 32-bit CRC-protected, 32-bit DMA, fully isolated\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Specifications:\u003c\/strong\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -40 to 70°C (-40 to 158°F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e -40 to 85°C (-40 to 185°F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity:\u003c\/strong\u003e 5 to 95% non-condensing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 4 kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 30 cm x 20 cm x 20 cm\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e The Triconex 3008 Main Processor is used in safety-critical applications where reliable and fault-tolerant control systems are required. It is ideal for industries such as oil and gas, power generation, chemical processing, and other process industries where safety and performance are paramount.\u003c\/p\u003e","brand":"Triconex","offers":[{"title":"Default Title","offer_id":49060027891994,"sku":"3008","price":1050.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/3008_1.jpg?v=1717154116"},{"product_id":"invensys-triconex-emp-ii-3005-processor-module","title":"Invensys Triconex Emp II 3005 Processor Module","description":"\u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e The Invensys Triconex 3005 Processor Module is a crucial component of the Triconex safety instrumented system (SIS), designed to provide high reliability and fault tolerance in critical industrial applications. It ensures the safe and efficient operation of processes in environments such as chemical plants, nuclear facilities, and oil and gas installations.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcessor:\u003c\/strong\u003e Utilizes a Motorola MPC860, 32-bit microprocessor operating at 50 MHz.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMemory:\u003c\/strong\u003e Equipped with 16 MB DRAM (non-battery backed-up), 32 KB SRAM (battery backed-up), and 6 MB Flash PROM for robust data handling and storage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication:\u003c\/strong\u003e Features a TriBus communication rate of 25 megabits per second with 32-bit CRC protection and fully isolated 32-bit DMA.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiagnostics:\u003c\/strong\u003e Includes advanced diagnostics for the health of the module, I\/O subsystem, and communication channels. It supports hot replacement of modules, ensuring continuous operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSerial Port:\u003c\/strong\u003e Provides an optically isolated RS-232 interface for diagnostic analysis, with 500 VDC isolation.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMicroprocessor:\u003c\/strong\u003e Motorola MPC860, 32-bit, 50 MHz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMemory Configuration:\u003c\/strong\u003e\u003cul\u003e\n\u003cli\u003e16 MB DRAM (non-battery backed-up)\u003c\/li\u003e\n\u003cli\u003e32 KB SRAM (battery backed-up)\u003c\/li\u003e\n\u003cli\u003e6 MB Flash PROM\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication Rate:\u003c\/strong\u003e 25 megabits per second, 32-bit CRC-protected, fully isolated 32-bit DMA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Specifications:\u003c\/strong\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -40 to 70°C (-40 to 158°F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e -40 to 85°C (-40 to 185°F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity:\u003c\/strong\u003e 5 to 95% non-condensing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 4 kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 30 cm x 20 cm x 20 cm\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e The Triconex 3005 Processor Module is used in safety-critical applications where reliability and fault tolerance are paramount. It is suitable for emergency shutdown systems, fire and gas protection, burner management systems, high integrity pressure protection systems, and turbine control.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eKey Advantages:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eProvides high-level protection for personnel and equipment.\u003c\/li\u003e\n\u003cli\u003eEnsures continuous safe operation and maximized equipment availability.\u003c\/li\u003e\n\u003cli\u003eSupports full life cycle performance, reducing operational risks and maximizing ownership value.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Triconex","offers":[{"title":"Default Title","offer_id":49060084678938,"sku":"3005","price":900.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/3008_4_983b0f09-265f-4efb-a6ea-9f056c562899.jpg?v=1717155514"},{"product_id":"invensys-triconex-8110-high-density-main-chassis","title":"Invensys Triconex 8110 High Density Main Chassis","description":"\u003cp\u003e\u003cstrong\u003eTricon System Overview\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eA Tricon system consists of a main chassis and up to 14 expansion or remote expansion (RXM) chassis. The system can support a maximum of 15 chassis, accommodating a total of 118 I\/O modules and communication modules. These modules interface with OPC clients, Modbus devices, other Tricons, and external host applications on Ethernet (802.3) networks, as well as Foxboro and Honeywell distributed control systems (DCS).\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eChassis Layout\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eEach chassis contains two power supplies on the left side, one positioned above the other. In the main chassis, three main processors are situated immediately to the right of the power supplies. The chassis is then divided into six logical slots for I\/O and communication modules, and one COM slot without a hot-spare position. Each logical slot has two physical spaces for modules: one for the active module and one for an optional hot-spare module.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eExpansion Chassis Configuration\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eThe layout of an expansion chassis mirrors that of the main chassis, except it offers eight logical slots for I\/O modules. The slots occupied by the main processors and the COM slot in the main chassis are available for other uses in the expansion chassis. Main and expansion chassis are connected via triplicated I\/O bus cables. The standard maximum length for these cables is 100 feet (30 meters), extendable to 1,000 feet (300 meters) in restricted applications. Consultation with a Triconex Customer Support representative is advised for configurations exceeding 30 meters.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eRemote Expansion (RXM) Chassis\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eRXM chassis are employed when the total cable distance between the first and last chassis exceeds the supported distance for copper cables. Each RXM chassis includes a set of three RXM modules placed in the same position as the main processors in the main chassis. Additionally, RXM chassis have six logical slots available for use and one blank (unused) slot.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOverall Dimensions\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e19 inches wide by 22.75 inches high by 17.75 inches deep (48.3 cm by 57.8 cm by 45.1 cm)\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eChassis Fabrication\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003eBlack zinc-plated and welded cold-rolled steel\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eApproximate Weights\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003eMain or Expansion Chassis: 54.0 lbs (24.5 kg)\u003c\/li\u003e\u003c\/ul\u003e","brand":"Triconex","offers":[{"title":"Default Title","offer_id":49060396073242,"sku":"8110","price":700.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/8110.jpg?v=1717155270"},{"product_id":"8310-invensys-triconex-power-module","title":"8310 Invensys Triconex Power Module","description":"\u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e The 8310 Triconex Power Module is a high-quality, robust component designed for industrial automation and safety systems. It provides reliable power to Triconex controllers, ensuring uninterrupted operation in critical applications. This module is engineered to deliver optimal performance and durability, making it a vital part of any Triconex control system.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Reliability:\u003c\/strong\u003e Designed to offer maximum reliability, minimizing downtime and ensuring continuous operation of safety systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRobust Construction:\u003c\/strong\u003e Built with durable materials to withstand harsh industrial environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEasy Integration:\u003c\/strong\u003e Compatible with various Triconex controllers, allowing for seamless integration into existing systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEfficient Power Supply:\u003c\/strong\u003e Provides stable and efficient power to ensure the proper functioning of connected controllers and devices.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Compliance:\u003c\/strong\u003e Meets industry safety standards, ensuring it can be used in safety-critical applications.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Voltage:\u003c\/strong\u003e 120\/240 VAC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Voltage:\u003c\/strong\u003e 24 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput VAC @ 47-63 Hz\u003c\/strong\u003e : 85–140\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Rating:\u003c\/strong\u003e 150W\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature Range:\u003c\/strong\u003e 0°C to 60°C (32°F to 140°F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature Range:\u003c\/strong\u003e -40°C to 85°C (-40°F to 185°F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity:\u003c\/strong\u003e 5% to 95% non-condensing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertifications:\u003c\/strong\u003e CE, UL, CSA\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eModule Weight:\u003c\/strong\u003e 3.8kg\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003eThe 8310 Triconex Power Module is an essential component for maintaining the integrity and efficiency of industrial safety systems. With its advanced features and robust specifications, it provides a reliable power source, ensuring the stability and performance of Triconex controllers.\u003c\/p\u003e","brand":"Triconex","offers":[{"title":"Default Title","offer_id":49066038919450,"sku":"8310","price":850.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/8310_1.jpg?v=1717218857"},{"product_id":"8311-triconex-power-supply-high-density-module","title":"8311 Triconex Power Supply High Density Module","description":"\u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e The 8310 Triconex Power Module is a high-quality, robust component designed for industrial automation and safety systems. It provides reliable power to Triconex controllers, ensuring uninterrupted operation in critical applications. This module is engineered to deliver optimal performance and durability, making it a vital part of any Triconex control system.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Reliability:\u003c\/strong\u003e Designed to offer maximum reliability, minimizing downtime and ensuring continuous operation of safety systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRobust Construction:\u003c\/strong\u003e Built with durable materials to withstand harsh industrial environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEasy Integration:\u003c\/strong\u003e Compatible with various Triconex controllers, allowing for seamless integration into existing systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEfficient Power Supply:\u003c\/strong\u003e Provides stable and efficient power to ensure the proper functioning of connected controllers and devices.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Compliance:\u003c\/strong\u003e Meets industry safety standards, ensuring it can be used in safety-critical applications.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Voltage:\u003c\/strong\u003e 120\/240 VAC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Voltage:\u003c\/strong\u003e 24 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Rating:\u003c\/strong\u003e 150W\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature Range:\u003c\/strong\u003e 0°C to 60°C (32°F to 140°F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature Range:\u003c\/strong\u003e -40°C to 85°C (-40°F to 185°F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity:\u003c\/strong\u003e 5% to 95% non-condensing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertifications:\u003c\/strong\u003e CE, UL, CSA\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eModule Weight:\u003c\/strong\u003e 3 kg\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003eThe 8310 Triconex Power Module is an essential component for maintaining the integrity and efficiency of industrial safety systems. With its advanced features and robust specifications, it provides a reliable power source, ensuring the stability and performance of Triconex controllers.\u003c\/p\u003e","brand":"Triconex","offers":[{"title":"Default Title","offer_id":49066059432218,"sku":"8311","price":800.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/8312.jpg?v=1717160377"},{"product_id":"invensys-triconex-8312-power-supply-module","title":"Invensys Triconex 8312 Power Supply Module","description":"\u003cp\u003e\u003cstrong\u003eChassis Type\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003eMain\/Expansion\/RXM\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e230 VAC\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eInput VAC @ 47-63 Hz\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e185–285\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eInput VDC\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003eNot applicable\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eFuse Rating and Type\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e2.5 amps, time-delay\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eOutput Hold Time (Nominal to 0 Volts)\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e20 ms minimum\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eDiagnostic Indicators\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003ePASS, FAULT, ALARM, TEMP, BAT LOW\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003ePower Modules\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e\u003cstrong\u003e230 VAC – 175-Watt Power Module\u003c\/strong\u003e\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003ePower Module Specifications\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation:\u003c\/strong\u003e Greater than 1,000 VAC or 1,500 VDC, Input to Output\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Terminations:\u003c\/strong\u003e Protected by safety cover, accepts three 12-gauge wires (3.310 mm²): neutral, hot, and protective earth (chassis ground)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOver-Temperature Sensor:\u003c\/strong\u003e Temperature warning monitor that trips when internal temperature exceeds 181°F (83°C); typically occurs at ambient temperature 140°F (60°C) or higher\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAlarm Contacts:\u003c\/strong\u003e Normally open, normally closed, and common; each contact supports 120 VAC @ 1 amp, accepts 12-gauge (3.310 mm²) wire, and is protected by a safety cover\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Power Required:\u003c\/strong\u003e 240 watts minimum per Power Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Power:\u003c\/strong\u003e 175 watts at 140°F (60°C)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Voltage:\u003c\/strong\u003e 6.5 VDC, ±1% under all operating conditions\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Current:\u003c\/strong\u003e 27 amps maximum at 140°F (60°C) ambient\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eOverall Dimensions: \u003c\/strong\u003e19 in wide by 22.75 in high by 17.75 in deep\u003cbr\u003e(48.3 cm by 57.8 cm by 45.1 cm)\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWeight: \u003c\/strong\u003e7.2 lbs. (3.3 kg.)\u003c\/p\u003e","brand":"Triconex","offers":[{"title":"Default Title","offer_id":49066098131226,"sku":"8312","price":500.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/8312_d084ae3a-2026-48a0-bfaa-369abf1ea79f.jpg?v=1717160499"},{"product_id":"3501e-invensys-triconex-digital-input-module","title":"3501E Invensys Triconex Digital Input Module","description":"\u003cp\u003e\u003cstrong\u003eVoltage\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e115 VAC\/VDC\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003eOpto-Isolated, Non-Commoned\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003eTMR (Triple Modular Redundancy)\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e3501E\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003ePoints\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e32, non-commoned, isolated\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eAC Range\/DC Range\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e90-155 VAC\/VDC\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eFrequency Range\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003eDC or 47-63 Hz\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eMaximum Voltage\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e155 VAC\/VDC\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eSwitching Level\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOFF to ON:\u003c\/strong\u003e Greater than 86 VAC\/VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eON to OFF:\u003c\/strong\u003e Less than 28 VAC\/VDC\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eNominal Turn-On\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e6-9 mA\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eTypical Hysteresis\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e32 VAC\/VDC\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eInput Delay\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOFF to ON:\u003c\/strong\u003e Less than 8 ms\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eON to OFF:\u003c\/strong\u003e Less than 15 ms\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003ePoint Isolation\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e1500 VDC \/ 2500 VDC\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eNominal Input Impedance\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003eGreater than 8.5 KΩ\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eNominal Field Power Load\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003ePer ON Point:\u003c\/strong\u003e\u003cul\u003e\n\u003cli\u003eAt maximum field voltage: 1.5 watts\u003c\/li\u003e\n\u003cli\u003e2.9 watts\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eDiagnostic Indicators\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Status:\u003c\/strong\u003e 1 per point\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Status:\u003c\/strong\u003e PASS, FAULT, ACTIVE\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eStuck Test\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003eNot applicable\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eColor Code\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003eRed\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003eThe 3501E Triconex Model is a high-performance, opto-isolated module designed for critical industrial applications. With features such as non-commoned points, robust point isolation, and comprehensive diagnostic indicators, it ensures reliable and efficient operation in demanding environments.\u003c\/p\u003e","brand":"Triconex","offers":[{"title":"Default Title","offer_id":49066205643034,"sku":"3501E","price":900.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/4210_2.jpg?v=1717216898"},{"product_id":"3504e-invensys-triconex-high-density-digital-input-module","title":"3504E Invensys Triconex High Density Digital Input Module","description":"\u003cp\u003e\u003cstrong\u003eSpecifications and Features\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e\u003cstrong\u003e3504E\u003c\/strong\u003e\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003eTMR (Triple Modular Redundancy)\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eVoltage\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e24 or 48 VDC (selected using the TriStation software)\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003ePoints\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e64, commoned, DC coupled\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eDC Range\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e20-72 VDC\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eMaximum Voltage\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e72 VDC\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eSwitching Level\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli style=\"list-style-type: none;\"\u003e\u003cul\u003e\n\u003cli\u003e24 V:\n\u003cul\u003e\n\u003cli\u003eOFF to ON: Greater than 18 VDC\u003c\/li\u003e\n\u003cli\u003eON to OFF: Less than 6 VDC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e48 V:\n\u003cul\u003e\n\u003cli\u003eOFF to ON: Greater than 32 VDC\u003c\/li\u003e\n\u003cli\u003eON to OFF: Less than 11 VDC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eNominal Turn-On\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003eNegligible\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eTypical Hysteresis\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e4 VDC\/7 VDC\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eInput Delay\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli style=\"list-style-type: none;\"\u003e\u003cul\u003e\n\u003cli\u003eOFF to ON: Less than 10 ms\u003c\/li\u003e\n\u003cli\u003eON to OFF: Less than 10 ms\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eMinimum Point Isolation\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003eNot applicable\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eNominal Input Impedance\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003eGreater than 30 KΩ\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eNominal Field Power Load\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003eNegligible\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eDiagnostic Indicators\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli style=\"list-style-type: none;\"\u003e\u003cul\u003e\n\u003cli\u003eInput Status: 1 per point\u003c\/li\u003e\n\u003cli\u003eModule Status: PASS, FAULT, ACTIVE\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eStuck Test\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003eON and OFF\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eColor Code\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003eDark Red\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e 4.7 to 6.0 lbs. (2.1 kg. to 2.7 kg)\u003c\/p\u003e\u003cp\u003eThe 3504E models are advanced modules designed for industrial applications, offering robust performance with high diagnostic capabilities. The 3564 is a single module with a broad DC range and quick response times, while the 3504E is a TMR module providing enhanced redundancy and reliability, with voltage selection flexibility. Both models feature detailed diagnostic indicators and are color-coded dark red for easy identification.\u003c\/p\u003e","brand":"Triconex","offers":[{"title":"Default Title","offer_id":49066325475610,"sku":"3504E","price":700.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/4351B_1.jpg?v=1717216954"},{"product_id":"3703e-invensys-triconex-isolated-analog-input-module","title":"3703E Invensys Triconex Isolated Analog Input Module","description":"\u003cp\u003e\u003cstrong\u003eAnalog Input Modules Overview\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eIntroduction\u003c\/strong\u003e Analog Input (AI) Modules consist of three independent input channels. Each channel receives variable voltage signals, converts them to digital values, and transmits these values to the three Main Processor modules upon request. In Triple Modular Redundancy (TMR) mode, a mid-value selection algorithm ensures correct data for every scan. Each input point is sensed in a way that prevents a single channel failure from affecting other channels. Ongoing diagnostics for each channel detect failures, activating the module's Fault indicator and the chassis alarm signal. The Fault indicator signals a channel fault, not a module failure, allowing the module to operate with up to two faulty channels. AI Modules support hot-spare capability for online replacement of faulty modules. They require an external termination panel (ETP) and are mechanically keyed for proper installation in a Tricon chassis.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eModule Specifications\u003c\/strong\u003e\u003cstrong\u003eModel Numbers:\u003c\/strong\u003e 3703E\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eVoltage:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e3703E: 0-5V or 0-10V, + 6% (selectable using TriStation 1131)\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eType:\u003c\/strong\u003e TMR, AI\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eNumber of Input Points:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e3703E: 16, differential, isolated\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eIsolated Points:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e3703E: Yes\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eInput Update Rate:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e3703E: 50 ms\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eResolution:\u003c\/strong\u003e 12 bits\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eAccuracy:\u003c\/strong\u003e \u0026lt; .15% of Full Scale Range (FSR), from 0° to 60°C\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eInput Resistance (load):\u003c\/strong\u003e 30 MΩ (DC), minimum\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePower-Off Resistance:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e3703E: 30 MΩ (DC), minimum\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eCommon Mode Rejection:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e3703E: -90 dB @ 60Hz, minimum; -100 dB @ DC, minimum\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eCommon Mode Range:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e3703E: +200V peak\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eLeg-to-Leg Isolation:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e3703E: 20 KΩ, typical\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eNormal Mode Rejection:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eAt 8Hz: -3 dB\u003c\/li\u003e\n\u003cli\u003eAt 60Hz: -17 dB\u003c\/li\u003e\n\u003cli\u003eAt 120Hz: -23 dB\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eInput Overrange Protection:\u003c\/strong\u003e 150 VDC\/115 VAC continuous\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCurrent Range:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e3703E: 0-20 mA, 250 Ω shunt for 5V, 500 Ω shunt for 10V\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eDiagnostic Indicators:\u003c\/strong\u003e Pass, Fault, Active\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e3703E: Mustard yellow\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eConclusion\u003c\/strong\u003e Analog Input Modules are integral components designed for reliability and accuracy, featuring independent input channels, comprehensive diagnostics, and the ability to operate despite channel failures. They are equipped with various safety and operational features, making them suitable for critical applications.\u003c\/p\u003e","brand":"Triconex","offers":[{"title":"Default Title","offer_id":49066469720346,"sku":"3703E","price":800.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/3704E_1_1c59727e-e1bd-4089-864b-c476a85b1100.jpg?v=1717217459"},{"product_id":"invensys-triconex-3721-tmr-analog-input-module","title":"Invensys Triconex 3721 TMR Analog Input Module","description":"\u003cp\u003e\u003cstrong\u003eIntroduction: \u003c\/strong\u003eAnalog Input (AI) Modules are designed to receive variable voltage signals, convert them to digital values, and transmit these values to the Main Processor modules. These modules support Triple Modular Redundancy (TMR) mode, ensuring data accuracy through a mid-value selection algorithm. Each module conducts ongoing diagnostics and supports hot-spare capability for online replacement. They require an external termination panel (ETP) and are keyed for proper installation in a Tricon chassis.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eModule Specifications\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eModel Numbers:\u003c\/strong\u003e 3721\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eVoltage:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e3721: 0 to 5VDC or -5 to +5VDC, +6%\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eType:\u003c\/strong\u003e TMR, AI\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eNumber of Input Points:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e3721: 32 differential, DC-coupled\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eIsolated Points:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e3721: Yes\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eInput Update Rate:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e3721: 10 ms\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eResolution:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e3721: 12 bits or 14 bits programmable\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eAccuracy:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e3721: \u0026lt; 0.15% of FSR from 0° to 60°C\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eInput Resistance (load):\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e3721: 10 MΩ (DC), minimum\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003ePower-Off Resistance:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e3721: 140 kΩ (DC), typical\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eCommon Mode Rejection:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e3721: -85 dB (DC - 100 Hz)\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eCommon Mode Range:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e3721: -12V to +12V peak\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eLeg-to-Leg Isolation:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e3721: 420 kΩ, typical\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eNormal Mode Rejection:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e3721: -3 dB @ 23Hz, -8 dB @ 60Hz, -14 dB @ 120Hz\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eInput Overrange Protection:\u003c\/strong\u003e 150 VDC\/115 VAC continuous\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCurrent Range:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e3721: 0-20 mA with 250 Ω shunt resistor\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eDiagnostic Indicators:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e3721: PASS, FAULT, ACTIVE, FIELD\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e3721: Yellow\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e: 4.7 to 6.0 lbs. (2.1 kg. to 2.7 kg.)\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eConclusion\u003c\/strong\u003e Analog Input Modules, with their various specifications and diagnostic capabilities, are essential for ensuring accurate and reliable data transmission in critical applications. Their support for TMR mode, ongoing diagnostics, and hot-spare capability makes them suitable for robust and fault-tolerant systems.\u003c\/p\u003e","brand":"Triconex","offers":[{"title":"Default Title","offer_id":49066535649562,"sku":"3721","price":1050.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/3720_3.jpg?v=1717162327"},{"product_id":"invensys-triconex-3625-digital-24vdc-output-modules","title":"Invensys Triconex 3625 Digital 24VDC Output Modules","description":"\u003cp\u003e\u003cstrong\u003eIntroduction\u003c\/strong\u003e Supervised Digital Output (SDO) modules are designed for critical control programs where outputs may remain in a single state for extended periods. These modules receive output signals from the Main Processors across three channels, which are then voted on by a fault-tolerant quadruplicated output switch. This switch passes a single voted output signal to the field termination.\u003c\/p\u003e\u003cp\u003eSDO modules incorporate voltage and current loopback circuitry with online diagnostics to verify the operation of each output switch, the field circuit, and the presence of a load, ensuring complete fault coverage without influencing the output signal. They detect various field faults, including power loss, open or missing loads, field shorts, and shorted loads in the de-energized state. Fault detection triggers appropriate alarms, and these modules support hot-spare capability. An external termination panel (ETP) is required for these modules.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eModule Specifications\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eModel Numbers:\u003c\/strong\u003e 3625\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eNominal Voltage:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e24 VDC\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eType:\u003c\/strong\u003e TMR, Supervised\/Non-Supervised DO\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOutput Signals:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e32, commoned\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eVoltage Range:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e16-32 VDC\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eMaximum Voltage:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e36 VDC\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eVoltage Drop:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e\u0026lt; 2.8 VDC @ 1.7A, typical\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003ePower Module Load:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e\u0026lt; 13 watts\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eCurrent Ratings (Maximum):\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e1.7A per point, 7A surge per 10 ms\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eMinimum Required Load:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e10 mA\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eLoad Leakage:\u003c\/strong\u003e 4 mA maximum\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFuses (on Field Termination):\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003eN\/A—self-protecting\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003ePoint Isolation:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e1,500 VDC\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eDiagnostic Indicators:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOn or Off State:\u003c\/strong\u003e 1 per point\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Status:\u003c\/strong\u003e PASS, FAULT, ACTIVE\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField Alarm:\u003c\/strong\u003e POWER, LOAD (1 per point)\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003eDark blue\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e: 4.7 to 6.0 lbs. (2.1 kg. to 2.7 kg.)\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eConclusion\u003c\/strong\u003e Supervised Digital Output Modules provide robust and reliable output control for critical systems, featuring comprehensive fault detection and diagnostic capabilities. They support hot-spare functionality and are designed to handle extended periods of output stability, making them suitable for demanding industrial applications.\u003c\/p\u003e","brand":"Triconex","offers":[{"title":"Default Title","offer_id":49066631495962,"sku":"3625","price":800.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/3624_3.jpg?v=1717162364"},{"product_id":"3636r-invensys-triconex-relay-output-module","title":"3636R Invensys Triconex Relay Output Module","description":"\u003cp\u003e\u003cstrong\u003eIntroduction\u003c\/strong\u003e The Model 3636R Relay Output (RO) Modules are designed for non-critical points that are not compatible with \"high-side\" solid-state output switches, such as interfacing with annunciator panels. These modules receive output signals from the Main Processors across three channels, which are then voted upon to drive 32 individual relays.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eModule Specifications\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eModel Numbers:\u003c\/strong\u003e 3636R\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eType:\u003c\/strong\u003e Non-triplicated, RO\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePoints:\u003c\/strong\u003e 32, non-commoned\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eVoltage Range:\u003c\/strong\u003e 125 VAC\/VDC, maximum\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCurrent Load:\u003c\/strong\u003e 2A, maximum\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eMinimum Permissible Load:\u003c\/strong\u003e 10 mA, 5 VDC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSwitching Power, Resistive:\u003c\/strong\u003e 2,000 VA, 150 watts maximum\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePoint Isolation:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e1,500 VDC\u003cbr\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eFuses:\u003c\/strong\u003e 1 per output (2.5A fast-acting)\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDiagnostic Indicators:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Status:\u003c\/strong\u003e 1 per point\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Status:\u003c\/strong\u003e PASS, FAULT, ACTIVE\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eOutput Contact:\u003c\/strong\u003e Normally Open\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e Silver Blue\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWeight: \u003c\/strong\u003e4.7 to 6.0 lbs. (2.1 kg. to 2.7 kg.)\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eConclusion\u003c\/strong\u003e The Relay Output modules offer reliable control for non-critical points, featuring independent relay operation verified by loopback circuits and ongoing diagnostics. They support hot-spare functionality and are suitable for applications where solid-state output switches are not compatible.\u003c\/p\u003e","brand":"Triconex","offers":[{"title":"Default Title","offer_id":49066674061594,"sku":"3636R","price":900.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/3624_2_17077921-b791-4a99-b67f-8594306eb039.jpg?v=1717217273"},{"product_id":"3603e-triconex-dc-digital-output-module","title":"3603E Triconex DC Digital Output Module","description":"\u003cp\u003e\u003cstrong\u003eTMR Digital Output Modules Overview\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eIntroduction\u003c\/strong\u003e TMR Digital Output (DO) modules receive output signals from the Main Processors across three channels. These signals are then voted by special quadruplicated output circuitry, providing redundancy for critical signal paths. Each module incorporates a voltage-loopback circuit to verify the operation of each output switch independently. Ongoing diagnostics ensure channel and circuit integrity.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eModule Specifications\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003e16-Point Digital Output Module Specifications\u003c\/strong\u003e\u003cstrong\u003eModel Numbers:\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eNominal Voltage:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e120 VDC\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eType:\u003c\/strong\u003e TMR, DO\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOutput Signals:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e16, commoned (3603E\/T),\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eVoltage Range:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e90-150 VDC\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eVoltage Drop:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e\u0026lt; 1.5V, typical\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eCurrent Ratings, Maximum:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e0.8A per point, 4A surge\/10 ms \u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eLoad Leakage:\u003c\/strong\u003e 2 mA maximum @ 60 Hz\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFuses (on Field Termination):\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e1 per output, 1.0A fast-acting\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003ePoint Isolation:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e1,500 VDC\/ 2,500 VDC\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eDiagnostic Indicators:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOn or Off state:\u003c\/strong\u003e 1 per point\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Status:\u003c\/strong\u003e PASS, FAULT, ACTIVE\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField Alarm:\u003c\/strong\u003e LOAD\/FUSE\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e Blue\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eConclusion\u003c\/strong\u003e TMR Digital Output Modules ensure safe and reliable operation of critical systems by providing redundant output circuits and comprehensive diagnostics. They support hot-spare capability and are designed for compatibility with various voltage ranges and signal types.\u003c\/p\u003e","brand":"Triconex","offers":[{"title":"Default Title","offer_id":49066729406746,"sku":"3603E","price":950.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/3009_1_f5d0d83f-8858-4807-9310-83d05524c736.jpg?v=1717217049"},{"product_id":"4351b-triconex-tricon-communication-module","title":"4351B Triconex Tricon Communication Module","description":"\u003ch2\u003e\u003cstrong\u003eTriconex 435X Series: Industrial Network Interface Solutions\u003c\/strong\u003e\u003c\/h2\u003e\u003cp\u003eThe \u003cb\u003e435X series\u003c\/b\u003e provides robust network connectivity for industrial control systems. Choose copper RJ-45 or fiber MT-RJ versions for different installation needs.\u003c\/p\u003e\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eDual-port design\u003c\/b\u003e: Copper (10\/100BaseT) or fiber (100Mbps)\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003e500VDC galvanic isolation\u003c\/b\u003e for noise immunity\u003c\/li\u003e\n\u003cli\u003eSupports \u003cb\u003eModbus, SNTP, OPC Server\u003c\/b\u003e protocols\u003c\/li\u003e\n\u003cli\u003ePeer-to-peer communication for \u003cb\u003e31 nodes\u003c\/b\u003e\n\u003c\/li\u003e\n\u003cli\u003eVisual \u003cb\u003estatus indicators\u003c\/b\u003e for quick diagnostics\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eCopper Models:\u003c\/b\u003e 4351\/4351A\/4351B\/4353 (RJ-45)\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eFiber Models:\u003c\/b\u003e 4352\/4352A\/4352B\/4354 (MT-RJ)\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eCable Length:\u003c\/b\u003e 100m max (Cat5 STP copper)\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eFiber Type:\u003c\/b\u003e 62.5\/125μm multimode\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eProtocols:\u003c\/b\u003e TCP\/IP, UDP\/IP, ICMP, DLC\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eIsolation:\u003c\/b\u003e 500VDC port-to-system\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003e\u003cstrong\u003eCommunication Capabilities\u003c\/strong\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eTime synchronization via SNTP\/GPS\u003c\/li\u003e\n\u003cli\u003eTriStation engineering tool integration\u003c\/li\u003e\n\u003cli\u003eEmbedded OPC Server (4353\/4354 models)\u003c\/li\u003e\n\u003cli\u003eTSAA multicast support\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003e\u003cstrong\u003eInstallation \u0026amp; Monitoring\u003c\/strong\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFront-panel accessible ports\u003c\/li\u003e\n\u003cli\u003eLED indicators for TX\/RX activity\u003c\/li\u003e\n\u003cli\u003eModule status: Pass\/Fault\/Active\u003c\/li\u003e\n\u003cli\u003eDIN rail mounting compatible\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003e\u003cstrong\u003eWarranty \u0026amp; Shipping\u003c\/strong\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e12-month warranty\u003c\/li\u003e\n\u003cli\u003eGlobal express delivery options\u003c\/li\u003e\n\u003cli\u003eFedEx\/UPS\/DHL available\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eQ: Difference between 4351 and 4353 models?\u003c\/b\u003e\u003cbr\u003eA: 4353 adds OPC Server and 100Mbps NET2 port.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eQ: Maximum fiber cable distance?\u003c\/b\u003e\u003cbr\u003eA: 2km with OM1 multimode fiber.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eQ: Supported OPC version?\u003c\/b\u003e\u003cbr\u003eA: OPC DA 2.05a specification.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eQ: Can copper and fiber models interconnect?\u003c\/b\u003e\u003cbr\u003eA: Requires media converters.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eQ: Firmware upgrade process?\u003c\/b\u003e\u003cbr\u003eA: Via TriStation software tools.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Triconex","offers":[{"title":"Default Title","offer_id":49066787111194,"sku":"4351B","price":900.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/4351B_1_f656d1b1-8039-404d-9f87-4b2bb59a3cff.jpg?v=1717217318"},{"product_id":"invensys-triconex-cm-3201-communication-module","title":"CM3201 Invensys Triconex CM 3201 Communication Module","description":"\u003ch2\u003e\u003cstrong\u003eTriconex CM3201 Communication Module: Industrial-Grade Connectivity Solution\u003c\/strong\u003e\u003c\/h2\u003e\u003ch3\u003e\u003cstrong\u003eProduct Introduction\u003c\/strong\u003e\u003c\/h3\u003e\u003cp\u003eThe \u003cstrong style=\"color: #0066cc;\"\u003eTriconex Trident CM3201\u003c\/strong\u003e enables robust communication between control systems and external devices. This industrial-grade interface supports critical automation connections. Use one module for standard operation or two for \u003cstrong\u003eredundant reliability\u003c\/strong\u003e.\u003c\/p\u003e\u003ch3\u003e\u003cstrong\u003eCore Features\u003c\/strong\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTriple isolated serial ports\u003c\/strong\u003e (RS-232\/RS-485)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Ethernet ports\u003c\/strong\u003e (10Mbps + 100Mbps)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRedundancy support\u003c\/strong\u003e for fail-safe operation\u003c\/li\u003e\n\u003cli\u003eOptical isolation against electrical noise\u003c\/li\u003e\n\u003cli\u003eHot-swappable in critical systems\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: \u003cspan style=\"color: #0066cc;\"\u003eTriconex\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel\u003c\/strong\u003e: \u003cspan style=\"color: #0066cc;\"\u003eTrident v2 CM\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSerial Ports\u003c\/strong\u003e: 3x configurable (115kbps max)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNetwork Ports\u003c\/strong\u003e: 10Mbps + 100Mbps\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtocol Support\u003c\/strong\u003e: Modbus, TSAA, TriStation, SNTP\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature Range\u003c\/strong\u003e: -40°C to 85°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation Protection\u003c\/strong\u003e: 2500V optical isolation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC Compliance\u003c\/strong\u003e: Industrial EMI\/RFI standards\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight\u003c\/strong\u003e: 5.0 lbs (2.3 kg)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003e\u003cstrong\u003eInstallation \u0026amp; Maintenance\u003c\/strong\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eTool-free DIN rail mounting\u003c\/li\u003e\n\u003cli\u003eColor-coded terminal blocks\u003c\/li\u003e\n\u003cli\u003eHot-swap capable in redundant setups\u003c\/li\u003e\n\u003cli\u003eStatus LEDs for instant diagnostics\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTrident v2\u003c\/strong\u003e systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTricon v9-v10\u003c\/strong\u003e controllers\u003c\/li\u003e\n\u003cli\u003eModbus-enabled devices\u003c\/li\u003e\n\u003cli\u003eDCS and SCADA networks\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003e\u003cstrong\u003eCertifications \u0026amp; Warranty\u003c\/strong\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eIndustrial EMI certified\u003c\/li\u003e\n\u003cli\u003e\u003cstrong style=\"color: #009900;\"\u003e12-month warranty\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eRoHS compliant\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003e\u003cstrong\u003ePackaging \u0026amp; Shipping\u003c\/strong\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e1x Communication Module\u003c\/li\u003e\n\u003cli\u003eMounting hardware kit\u003c\/li\u003e\n\u003cli\u003eQuick-start guide\u003c\/li\u003e\n\u003cli\u003eGlobal shipping: FedEx\/UPS\/DHL\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003e\u003cstrong\u003eDiagnostics Capabilities\u003c\/strong\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eReal-time port status monitoring\u003c\/li\u003e\n\u003cli\u003eProtocol error logging\u003c\/li\u003e\n\u003cli\u003eNetwork health indicators\u003c\/li\u003e\n\u003cli\u003eAutomatic failover alerts\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan both serial and Ethernet ports work together?\u003c\/strong\u003e\u003cbr\u003eYes. All ports operate simultaneously.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow does redundancy work?\u003c\/strong\u003e\u003cbr\u003eBackup module activates within milliseconds.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat cables are included?\u003c\/strong\u003e\u003cbr\u003eStandard industrial cables sold separately.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Triconex","offers":[{"title":"Default Title","offer_id":49066836787482,"sku":"CM-3201","price":860.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/CM3201_4.jpg?v=1717247018"},{"product_id":"invensys-triconex-3481-ao3481-analog-output-module","title":"Invensys Triconex 3481 AO3481 Analog Output Module","description":"\u003ch4\u003eAnalog Output Modules\u003c\/h4\u003e\u003cp\u003eEach TMR Analog Output Module has three isolated sets of electronics, called channels, which independently accept data from the MP associated with each channel. The channels provide input to voter circuitry to select a single channel to drive the output. Special circuitry is used to ensure that the channels that are not driving the output are shunted so they cannot affect the output.\u003c\/p\u003e\u003cp\u003eAO Modules include complete, ongoing diagnostics for each channel. If the diagnostics detect a failure on any channel, the Fault indicator turns on and activates the system alarm. The Fault indicator identifies a channel fault, not a complete module failure. AO Modules are guaranteed to operate properly in the presence of a single fault and may continue to operate properly with multiple faults. AO Modules support a hot-spare module. Each AO Module is mechanically keyed to prevent improper installation in a configured baseplate.\u003c\/p\u003e\u003ch3\u003eModel 3481 AO Module Baseplate Compatibility\u003c\/h3\u003e\u003cp\u003eThe Model 3481 AO Module can be used with these baseplates:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel 2481\u003c\/strong\u003e: Used in typical applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel 2483\u003c\/strong\u003e: Enables communication between HART field devices and Configuration and Asset Management Software running on a PC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel 2483A\u003c\/strong\u003e: Used in hazardous locations and enables communication between HART field devices and Configuration and Asset Management Software running on a PC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDO External Termination Baseplate\u003c\/strong\u003e: Used with the Model 9863-610 External Termination Panel in hazardous locations. Note that “DO” is not a typo; the DO External Termination Baseplate is used with the 9863-610.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eModel 3481 Analog Output Module Specifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePoints\u003c\/strong\u003e: 4, commoned-return, DC-coupled\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolated Points\u003c\/strong\u003e: None\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Current Range\u003c\/strong\u003e:\n\u003cul\u003e\n\u003cli\u003e4–20 mA output, controlled\u003c\/li\u003e\n\u003cli\u003e0–22 mA over-range\u003c\/li\u003e\n\u003cli\u003e0 mA output capability (step function \u0026lt; 2 mA)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Accuracy\u003c\/strong\u003e: \u0026lt;0.25% (in range of 4–20 mA) of FSR (0–22 mA), from 32° F to 158° F (0° C to 70° C)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType\u003c\/strong\u003e: TMR\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResolution\u003c\/strong\u003e: 12 bits\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiagnostic\u003c\/strong\u003e: Forced-switch diagnostic (FSD)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExternal Loop Power\u003c\/strong\u003e:\n\u003cul\u003e\n\u003cli\u003eReverse voltage-protected\u003c\/li\u003e\n\u003cli\u003e32 VDC, maximum\u003c\/li\u003e\n\u003cli\u003e24 VDC, nominal\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Loop Power Requirements for Specified Load\u003c\/strong\u003e:\n\u003cul\u003e\n\u003cli\u003e300 Ω @ \u0026gt;16 VDC (1 A minimum)\u003c\/li\u003e\n\u003cli\u003e500 Ω @ \u0026gt;20 VDC (1 A minimum)\u003c\/li\u003e\n\u003cli\u003e700 Ω @ \u0026gt;24 VDC (1 A minimum)\u003c\/li\u003e\n\u003cli\u003e800 Ω @ \u0026gt;28 VDC (1 A minimum)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOver-Range Protection\u003c\/strong\u003e:\n\u003cul\u003e\n\u003cli\u003e36 VDC, continuous\u003c\/li\u003e\n\u003cli\u003e0 VDC, continuous\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitch Time on Leg Failure\u003c\/strong\u003e:\n\u003cul\u003e\n\u003cli\u003e1 ms, typical\u003c\/li\u003e\n\u003cli\u003e3 ms, maximum\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Triconex","offers":[{"title":"Default Title","offer_id":49073288872218,"sku":"AO3481","price":900.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/AO34813.jpg?v=1717235538"},{"product_id":"invensys-triconex-4000094-310-input-terminal-cable-assembly","title":"Invensys Triconex 4000094-310 Input Terminal Cable Assembly","description":"\u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan\u003eThe TRICONEX 4000094-310 Input Terminal Cable Assembly is an essential component designed to connect various electronic equipment systems or subsystems. This cable assembly features insulated wires, shielded wires, and electrical connectors, ensuring a reliable connection in complex electrical environments. Its primary function is to maintain electrical stability, durability, and resistance to environmental factors.\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Precision\u003c\/strong\u003e: Utilizes advanced manufacturing processes to ensure high precision and reliability.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection Types\u003c\/strong\u003e: Supports direct welding, crimping, and clamping connection methods to suit different installation requirements​.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDurability\u003c\/strong\u003e\u003cspan\u003e: Built to withstand frequent use and harsh environmental conditions, extending the service life of the cable assembly.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eechnical Parameters\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage\u003c\/strong\u003e: Designed for systems requiring 24 VDC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: Can function effectively in temperatures ranging from -40°C to +70°C.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMemory\u003c\/strong\u003e: Equipped with 512 KB RAM for efficient data handling.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication Ports\u003c\/strong\u003e: Includes Ethernet, RS-232, RS-485, and USB ports for versatile connectivity options.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLength\u003c\/strong\u003e: Standard length of 10 feet (approximately 3 meters).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight\u003c\/strong\u003e: The cable assembly weighs approximately 1 kg.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Triconex","offers":[{"title":"Default Title","offer_id":49077396799770,"sku":"4000094-310","price":200.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/4000103-510_3.jpg?v=1717298077"},{"product_id":"triconex-9753-110-voltage-input-termination-board","title":"Triconex 9753-110 Voltage Input Termination Board","description":"\u003cp\u003eThe Termination Panel 9753-110 is versatile and compatible with both pulse input modules and pulse totalizer input modules. It provides a reliable interface for various input signal types and is designed for easy integration and robust performance in industrial applications.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eTermination Panel 9753-110 Overview\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eThe 9753-110 termination panel supports multiple configurations depending on the type of input module used. When paired with pulse input modules, it offers 8 differential-input signal terminals (IN+ and IN–). When used with pulse totalizer input modules, it supports 16 input signal terminals (IN+ and IN–), requiring two termination panels per pulse totalizer input module due to the 32 points on the modules.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSpecifications for Term Panel 9753-110\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePanel Type:\u003c\/strong\u003e Basic\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePoints:\u003c\/strong\u003e\u003cul\u003e\n\u003cli\u003e8 when used with pulse input modules\u003c\/li\u003e\n\u003cli\u003e16 when used with pulse totalizer input modules\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eCompatible Modules\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003ePulse Input Modules:\u003c\/strong\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e3510:\u003c\/strong\u003e 8 points, 20 Hz to 20 KHz pulse input, non-commoned, AC-coupled, 50 ms typical input update rate\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e3511:\u003c\/strong\u003e 8 points, 20 Hz to 20 KHz pulse input, non-commoned, AC-coupled, 25 ms typical input update rate\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e3515:\u003c\/strong\u003e 32 points, 0 to 1 kHz pulse totalizer input, non-commoned\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eVoltage Input Term Panels\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eThe 9753-110 is also compatible with 0 to 5 VDC, -5 to +5 VDC, or 0 to 10 VDC analog input modules. It includes 16 voltage input terminals (IN+ and IN–) with commoned return terminals (RTN). For 32-point modules, two term panels are required per module, and the panels come with two sets of labels: 1-16 and 17-32.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSpecifications for Voltage Input Term Panel 9753-110\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePanel Type:\u003c\/strong\u003e Voltage input, basic\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePoints:\u003c\/strong\u003e 16\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eCompatible Analog Input Modules\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e3700:\u003c\/strong\u003e 32 points, 0–5 VDC, non-commoned, differential, DC-coupled, TMR\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e3700A:\u003c\/strong\u003e 32 points, 0–5 VDC, non-commoned, differential, DC-coupled, TMR\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e3701:\u003c\/strong\u003e 32 points, 0–10 VDC, non-commoned, differential, DC-coupled, TMR\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e3703E:\u003c\/strong\u003e 16 points, 0–5 VDC or 0–10 VDC (configurable via TriStation), non-commoned, differential, isolated, TMR\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e3721:\u003c\/strong\u003e 32 points, 0 to 5 VDC or –5 to +5 VDC (configurable via TriStation), differential, DC-coupled, TMR\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth:\u003c\/strong\u003e 3 inches (7.62 cm)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight:\u003c\/strong\u003e 5 inches (12.7 cm)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDepth:\u003c\/strong\u003e 4.25 inches (10.795 cm)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Triconex","offers":[{"title":"Default Title","offer_id":49098886742298,"sku":"9753-110","price":200.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/9753-110_1.jpg?v=1717507162"},{"product_id":"triconex-invensys-3624-24vdc-digital-output-module","title":"Triconex Invensys 3624 24VDC Digital Output Module","description":"\u003ch3\u003eTriconex Invensys 3624 16-Point Supervised Digital Output Modules\u003c\/h3\u003e\u003ch4\u003eDescription\u003c\/h4\u003e\u003cp\u003eDesigned for the most critical control programs, the supervised digital output (SDO) modules are ideal for systems where outputs remain in a single state for extended periods, sometimes years. Each SDO module receives output signals from the main processors on three channels. The signals are voted upon by a fully fault-tolerant quadruplicated output switch with power transistors, producing a single voted output signal passed to the field termination.\u003c\/p\u003e\u003cp\u003eThe SDO modules feature voltage and current loopback circuitry, along with sophisticated online diagnostics, verifying the operation of each output switch, the field circuit, and the presence of a load. This comprehensive fault coverage does not interfere with the output signal. The \"supervised\" designation indicates the module's ability to detect potential field problems, including:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eLoss of power or blown fuse\u003c\/li\u003e\n\u003cli\u003eOpen or missing load\u003c\/li\u003e\n\u003cli\u003eField short causing unintended load energization\u003c\/li\u003e\n\u003cli\u003eShorted load in the de-energized state\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eField voltage detection failure on any output point triggers the power alarm indicator, while load presence detection failure triggers the load alarm indicator. All SDO modules support hot-spare modules and require a separate external termination panel (ETP) with a cable interface to the Tricon backplane.\u003c\/p\u003e\u003ch3\u003eKey Features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCritical Control Programs\u003c\/strong\u003e: Ideal for systems with extended output states.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFault-Tolerant Design\u003c\/strong\u003e: Fully fault-tolerant quadruplicated output switch ensures reliable operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eComprehensive Diagnostics\u003c\/strong\u003e: Voltage and current loopback circuitry with online diagnostics.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField Supervision\u003c\/strong\u003e: Detects various field faults, including power loss, open or missing load, field short, and shorted load.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHot-Spare Support\u003c\/strong\u003e: All modules support hot-spare replacements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExternal Termination Panel\u003c\/strong\u003e: Requires a separate ETP with a cable interface to the Tricon backplane.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eModels: 3624\u003c\/h3\u003e\u003ctable style=\"width: 100%; height: 352.688px;\"\u003e\n\u003cthead\u003e\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth style=\"width: 33.3948%; height: 19.5938px;\"\u003eFeature\u003c\/th\u003e\n\u003cth style=\"width: 66.2362%; height: 19.5938px;\"\u003eModel 3624\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 33.3948%; height: 19.5938px;\"\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.2362%; height: 19.5938px;\"\u003e                                        24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 33.3948%; height: 19.5938px;\"\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.2362%; height: 19.5938px;\"\u003e                                   TMR, Supervised\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 33.3948%; height: 19.5938px;\"\u003e\u003cstrong\u003eOutput Signals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.2362%; height: 19.5938px;\"\u003e                                     16, commoned\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 33.3948%; height: 19.5938px;\"\u003e\u003cstrong\u003eVoltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.2362%; height: 19.5938px;\"\u003e                                       16-30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 33.3948%; height: 19.5938px;\"\u003e\u003cstrong\u003eMaximum Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.2362%; height: 19.5938px;\"\u003e                                         36 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 33.3948%; height: 19.5938px;\"\u003e\u003cstrong\u003eVoltage Drop\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.2362%; height: 19.5938px;\"\u003e                                   \u0026lt; 1.5 VDC, typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 33.3948%; height: 19.5938px;\"\u003e\u003cstrong\u003ePower Module Load\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.2362%; height: 19.5938px;\"\u003e                                        \u0026lt; 10 watts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 33.3948%; height: 39.1875px;\"\u003e\u003cstrong\u003eCurrent Ratings, Maximum\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.2362%; height: 39.1875px;\"\u003e                        0.7A per point, 4.8A surge per 10 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 33.3948%; height: 19.5938px;\"\u003e\u003cstrong\u003eMinimum Required Load\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.2362%; height: 19.5938px;\"\u003e                                         30 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 33.3948%; height: 19.5938px;\"\u003e\u003cstrong\u003eLoad Leakage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.2362%; height: 19.5938px;\"\u003e                                    4 mA maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 33.3948%; height: 39.1875px;\"\u003e\u003cstrong\u003eFuses (on Field Termination)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.2362%; height: 39.1875px;\"\u003e                                 n\/a—self-protecting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 33.3948%; height: 19.5938px;\"\u003e\u003cstrong\u003ePoint Isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.2362%; height: 19.5938px;\"\u003e                                      1500 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 33.3948%; height: 39.1875px;\"\u003e\u003cstrong\u003eDiagnostic Indicators\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.2362%; text-align: center; height: 39.1875px;\"\u003e                    1 per point, PASS, FAULT, ACTIVE, POWER, LOAD (1 per point)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 33.3948%; height: 19.5938px;\"\u003e\u003cstrong\u003eColor Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 66.2362%; height: 19.5938px; text-align: center;\"\u003e    Turquoise Green\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003cp\u003e\u003c\/p\u003e","brand":"Triconex","offers":[{"title":"Default Title","offer_id":49117520363802,"sku":"3624","price":700.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/3624_2_ff5afb76-e765-42b2-a367-53f0083f4af6.jpg?v=1717674857"},{"product_id":"triconex-3503e-tmr-digital-input-module","title":"Triconex 3503E TMR Digital Input Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Model 3503E is a Triple Modular Redundant (TMR) digital input module designed to ensure high reliability and safety for industrial applications. It is specifically designed to detect stuck-ON conditions where the circuitry cannot tell whether a point has gone to the OFF state, which is crucial for safety systems that operate with a de-energize-to-trip capability.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eThree isolated input channels\u003c\/strong\u003e: Each channel processes data independently.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptical isolation\u003c\/strong\u003e: Provides isolation between the field and the Tricon.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSelf-testing capability\u003c\/strong\u003e: Detects stuck-ON conditions and ensures accurate OFF state detection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHot-spare capability\u003c\/strong\u003e: Allows for on-the-fly replacement without system shutdown.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOngoing diagnostics\u003c\/strong\u003e: Constant monitoring of each channel with fault indicators for rapid issue identification.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeparate external termination panel (ETP)\u003c\/strong\u003e: Facilitates cable interface to the Tricon backplane.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical keying\u003c\/strong\u003e: Prevents improper installation in a configured chassis.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eType\u003c\/strong\u003e: TMR with Self-Test\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage\u003c\/strong\u003e: 24 VAC\/VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePoints\u003c\/strong\u003e: 32, commoned in groups of 8\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC Range\u003c\/strong\u003e: 20-42.5 VAC\/VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency Range\u003c\/strong\u003e: DC or 47-63 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Voltage\u003c\/strong\u003e: 42.5 VAC\/VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan _mstmutation=\"1\"\u003e\u003cstrong _mstmutation=\"1\"\u003eSwitching Level\u003c\/strong\u003e:\u003c\/span\u003e\u003cul\u003e\n\u003cli\u003eOFF to ON: \u0026gt; 18 VAC\/VDC\u003c\/li\u003e\n\u003cli\u003eON to OFF: \u0026lt; 6 VAC\/VDC\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplication\u003c\/h3\u003e\u003cp\u003e\u003cspan _mstmutation=\"1\"\u003eThe 3503E module is suitable for applications requiring high safety and reliability, such as those in the petrochemical, power generation, and manufacturing industries. It ensures that critical input signals are accurately processed and maintained even in the presence of faults, thus providing a robust solution for safety-critical systems​\u003c\/span\u003e\u003cspan _mstmutation=\"1\"\u003e​.\u003c\/span\u003e\u003c\/p\u003e","brand":"Triconex","offers":[{"title":"Default Title","offer_id":49232129949978,"sku":"3503E","price":200.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/TRICONEX4409_2.jpg?v=1719279098"},{"product_id":"3700a-tmr-analog-input-module-invensys-triconex","title":"3700A TMR Analog Input Module Invensys Triconex","description":"\u003cp\u003e\u003cstrong\u003e3700 Analog Input Specifications\u003c\/strong\u003e\u003c\/p\u003e\u003ctable height=\"613\" style=\"width: 100.547%; height: 483px;\"\u003e\n\u003cthead\u003e\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth style=\"width: 45.0185%; height: 19.5938px;\"\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth style=\"width: 54.6125%; height: 19.5938px;\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 21.0781px;\"\u003e\n\u003ctd style=\"width: 45.0185%; height: 21.0781px;\"\u003e\u003cstrong\u003eColor code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 54.6125%; height: 21.0781px;\"\u003eYellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21.0781px;\"\u003e\n\u003ctd style=\"width: 45.0185%; height: 21.0781px;\"\u003e\u003cstrong\u003eNumber of input signals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 54.6125%; height: 21.0781px;\"\u003e32 differential, DC-coupled\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21.0781px;\"\u003e\n\u003ctd style=\"width: 45.0185%; height: 21.0781px;\"\u003e\u003cstrong\u003eInput update rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 54.6125%; height: 21.0781px;\"\u003e55 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21.0781px;\"\u003e\n\u003ctd style=\"width: 45.0185%; height: 21.0781px;\"\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 54.6125%; height: 21.0781px;\"\u003e12 bits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21.0781px;\"\u003e\n\u003ctd style=\"width: 45.0185%; height: 21.0781px;\"\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 54.6125%; height: 21.0781px;\"\u003e\u0026lt; 0.15% of FSR, from 0° to 60° C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21.0781px;\"\u003e\n\u003ctd style=\"width: 45.0185%; height: 21.0781px;\"\u003e\u003cstrong\u003eInput resistance (load)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 54.6125%; height: 21.0781px;\"\u003e30 MΩ (DC), minimum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21.0781px;\"\u003e\n\u003ctd style=\"width: 45.0185%; height: 21.0781px;\"\u003e\u003cstrong\u003eInput resistance @ power off\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 54.6125%; height: 21.0781px;\"\u003e30 kΩ (DC), typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21.0781px;\"\u003e\n\u003ctd style=\"width: 45.0185%; height: 21.0781px;\"\u003e\u003cstrong\u003eCommon mode rejection (typical)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 54.6125%; height: 21.0781px;\"\u003e-80 dB (DC - 100 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21.0781px;\"\u003e\n\u003ctd style=\"width: 45.0185%; height: 21.0781px;\"\u003e\u003cstrong\u003eCommon mode range (See Warning)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 54.6125%; height: 21.0781px;\"\u003e-12V to +12V peak\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21.0781px;\"\u003e\n\u003ctd style=\"width: 45.0185%; height: 21.0781px;\"\u003e\u003cstrong\u003eChannel-to-channel isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 54.6125%; height: 21.0781px;\"\u003e200 kΩ, typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 41.9062px;\"\u003e\n\u003ctd style=\"width: 45.0185%; height: 41.9062px;\"\u003e\u003cstrong\u003eNormal mode rejection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 54.6125%; height: 41.9062px;\"\u003e-3 dB @ 8 Hz, -17 dB @ 60 Hz, -23 dB @ 120 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21.0781px;\"\u003e\n\u003ctd style=\"width: 45.0185%; height: 21.0781px;\"\u003e\u003cstrong\u003eInput voltage range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 54.6125%; height: 21.0781px;\"\u003e0 to 5V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 41.9062px;\"\u003e\n\u003ctd style=\"width: 45.0185%; height: 41.9062px;\"\u003e\u003cstrong\u003eInput over-range measurement (3700A)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 54.6125%; height: 41.9062px;\"\u003e+6%, 0 to 5.3 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21.0781px;\"\u003e\n\u003ctd style=\"width: 45.0185%; height: 21.0781px;\"\u003e\u003cstrong\u003eLogic power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 54.6125%; height: 21.0781px;\"\u003e\u0026lt; 10 watts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21.0781px;\"\u003e\n\u003ctd style=\"width: 45.0185%; height: 21.0781px;\"\u003e\u003cstrong\u003eInput over-range protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 54.6125%; height: 21.0781px;\"\u003e150 VDC continuous, 115 VAC continuous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21.0781px;\"\u003e\n\u003ctd style=\"width: 45.0185%; height: 21.0781px;\"\u003e\u003cstrong\u003eInput current range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 54.6125%; height: 21.0781px;\"\u003e0 to 20 mA with 250 Ω shunt resistor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21.0781px;\"\u003e\n\u003ctd style=\"width: 45.0185%; height: 21.0781px;\"\u003e\u003cstrong\u003eModule status indicators\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 54.6125%; height: 21.0781px;\"\u003ePass, Fault, Active\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21.0781px;\"\u003e\n\u003ctd style=\"width: 45.0185%; height: 21.0781px;\"\u003e\u003cstrong\u003eInput diagnostic fault coverage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 54.6125%; height: 21.0781px;\"\u003e2% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21.0781px;\"\u003e\n\u003ctd style=\"width: 45.0185%; height: 21.0781px;\"\u003e\u003cstrong\u003eInput change sample period\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 54.6125%; height: 21.0781px;\"\u003e1 scan or 200 ms, whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 21.2656px;\"\u003e\n\u003ctd style=\"width: 45.0185%; height: 21.2656px;\"\u003e\u003cstrong\u003eMinimum period of mis-compares\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 54.6125%; height: 21.2656px;\"\u003e40 samples\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Triconex","offers":[{"title":"Default Title","offer_id":49232133062938,"sku":"3700A","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/3720_1_a07974ca-eb6a-443c-a8ae-7419e668e81d.jpg?v=1719279245"},{"product_id":"3700-invensys-triconex-analog-input-module","title":"3700 Invensys Triconex Analog Input Module","description":"\u003ch3\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eColor Code\u003c\/strong\u003e: Yellow\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Input Signals\u003c\/strong\u003e: 32 differential, DC-coupled\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Update Rate\u003c\/strong\u003e: 55 ms\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResolution\u003c\/strong\u003e: 12 bits\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy\u003c\/strong\u003e: \u0026lt; 0.15% of FSR, from 0° to 60° C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Resistance\u003c\/strong\u003e\u003cul\u003e\n\u003cli\u003eLoad: 30 MΩ (DC), minimum\u003c\/li\u003e\n\u003cli\u003e@ Power Off: 30 kΩ (DC), typical\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommon Mode Rejection (Typical)\u003c\/strong\u003e: -80 dB (DC - 100 Hz)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommon Mode Range\u003c\/strong\u003e (See Warning): -12V to +12V peak\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannel-to-Channel Isolation\u003c\/strong\u003e: 200 kΩ, typical\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNormal Mode Rejection\u003c\/strong\u003e\u003cul\u003e\n\u003cli\u003e-3 dB @ 8 Hz\u003c\/li\u003e\n\u003cli\u003e-17 dB @ 60 Hz\u003c\/li\u003e\n\u003cli\u003e-23 dB @ 120 Hz\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Voltage Range\u003c\/strong\u003e: 0 to 5V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Over-Range Measurement\u003c\/strong\u003e (only for 3700A): +6%, 0 to 5.3 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLogic Power\u003c\/strong\u003e: \u0026lt; 10 watts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Over-Range Protection\u003c\/strong\u003e: 150 VDC continuous, 115 VAC continuous\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Current Range\u003c\/strong\u003e: 0 to 20 mA with 250 Ω shunt resistor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Status Indicators\u003c\/strong\u003e: Pass, Fault, Active\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Diagnostic Fault Coverage\u003c\/strong\u003e:\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMinimum Input Change\u003c\/strong\u003e: 2% of full scale\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Change Sample Period\u003c\/strong\u003e: 1 scan or 200 ms, whichever is greater\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMinimum Period of Mis-Compares\u003c\/strong\u003e: 40 samples\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Triconex","offers":[{"title":"Default Title","offer_id":49232931782938,"sku":"3700","price":200.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/3704E_2_2ca29685-5ede-4a1f-aa85-8cd29d4d4fde.jpg?v=1719279246"},{"product_id":"3623-triconex-120vdc-digital-output-module","title":"3623 Triconex 120vdc Digital Output Module","description":"\u003ch3\u003e\u003cstrong\u003eTechnical Specification:\u003c\/strong\u003e\u003c\/h3\u003e\u003ctable style=\"width: 101.095%; height: 318px;\"\u003e\n\u003cthead\u003e\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth style=\"width: 40.9594%; height: 19.5938px;\"\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth style=\"width: 58.6716%; height: 19.5938px;\"\u003e\u003cstrong\u003e3623\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.8906px;\"\u003e\n\u003ctd style=\"width: 40.9594%; height: 19.8906px;\"\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.6716%; height: 19.8906px;\"\u003e3623\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.8906px;\"\u003e\n\u003ctd style=\"width: 40.9594%; height: 19.8906px;\"\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.6716%; height: 19.8906px;\"\u003e120 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.8906px;\"\u003e\n\u003ctd style=\"width: 40.9594%; height: 19.8906px;\"\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.6716%; height: 19.8906px;\"\u003eTMR, Supervised DO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.8906px;\"\u003e\n\u003ctd style=\"width: 40.9594%; height: 19.8906px;\"\u003e\u003cstrong\u003eOutput Signals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.6716%; height: 19.8906px;\"\u003e16, commoned\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.8906px;\"\u003e\n\u003ctd style=\"width: 40.9594%; height: 19.8906px;\"\u003e\u003cstrong\u003eVoltage Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.6716%; height: 19.8906px;\"\u003e90-150 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.8906px;\"\u003e\n\u003ctd style=\"width: 40.9594%; height: 19.8906px;\"\u003e\u003cstrong\u003eMaximum Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.6716%; height: 19.8906px;\"\u003e160 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.8906px;\"\u003e\n\u003ctd style=\"width: 40.9594%; height: 19.8906px;\"\u003e\u003cstrong\u003eVoltage Drop\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.6716%; height: 19.8906px;\"\u003e\u0026lt; 1.5 VDC, typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.8906px;\"\u003e\n\u003ctd style=\"width: 40.9594%; height: 19.8906px;\"\u003e\u003cstrong\u003ePower Module Load\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.6716%; height: 19.8906px;\"\u003e\u0026lt; 10 watts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.8906px;\"\u003e\n\u003ctd style=\"width: 40.9594%; height: 19.8906px;\"\u003e\u003cstrong\u003eCurrent Ratings\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.6716%; height: 19.8906px;\"\u003e0.8A per point, 4A surge per 10 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.8906px;\"\u003e\n\u003ctd style=\"width: 40.9594%; height: 19.8906px;\"\u003e\u003cstrong\u003eMinimum Required Load\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.6716%; height: 19.8906px;\"\u003e30 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.8906px;\"\u003e\n\u003ctd style=\"width: 40.9594%; height: 19.8906px;\"\u003e\u003cstrong\u003eLoad Leakage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.6716%; height: 19.8906px;\"\u003e4 mA maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.8906px;\"\u003e\n\u003ctd style=\"width: 40.9594%; height: 19.8906px;\"\u003e\u003cstrong\u003eFuses (on Field Termination)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.6716%; height: 19.8906px;\"\u003e1A fast-acting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.8906px;\"\u003e\n\u003ctd style=\"width: 40.9594%; height: 19.8906px;\"\u003e\u003cstrong\u003ePoint Isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.6716%; height: 19.8906px;\"\u003e1,500 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.8906px;\"\u003e\n\u003ctd style=\"width: 40.9594%; height: 19.8906px;\"\u003e\u003cstrong\u003eDiagnostic Indicators\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.6716%; height: 19.8906px;\"\u003eOn or Off State, Module Status, Field Alarm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.9375px;\"\u003e\n\u003ctd style=\"width: 40.9594%; height: 19.9375px;\"\u003e\u003cstrong\u003eColor Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 58.6716%; height: 19.9375px;\"\u003eSteel blue\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Triconex","offers":[{"title":"Default Title","offer_id":49238776283418,"sku":"3623","price":200.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/3008_3_7d4bfbf7-a5cf-4093-9bc2-29cbed70e2eb.jpg?v=1719318559"},{"product_id":"triconex-1600071-001-trisen-turbosentry","title":"Triconex 1600071-001 Trisen TurboSentry","description":"\u003ch3\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003c\/h3\u003e\u003cp\u003eThe Triconex 1600071-001 Trisen TurboSentry is a robust safety PLC designed specifically for critical applications where safety and reliability are paramount. Part of Triconex's Trisen family, known for its high performance and dependability, the TurboSentry features a fault-tolerant architecture ensuring continuous operation even in the event of component failures. Its modular design allows flexible scalability to accommodate diverse application requirements.\u003c\/p\u003e\u003ch3\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eFault-tolerant architecture\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eModular design for scalability\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eSIL 3 certified by TÜV Rheinland\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eCompliant with IEC 61508 international safety standard\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eIdeal for various safety applications\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 16.0\" x 3.0\" x 6.0\" (40.6 cm x 7.6 cm x 15.2 cm)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 4 lbs 11.2 oz (2.1 kg)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Triconex","offers":[{"title":"Default Title","offer_id":49244170715418,"sku":"1600071-001","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/1600071-001_1.jpg?v=1719380067"},{"product_id":"3805e-invensys-triconex-analog-output-module","title":"3805E Invensys Triconex Analog Output Module","description":"\u003ch3\u003e\u003cstrong\u003eCommon Specifications:\u003c\/strong\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eColor Code:\u003c\/strong\u003e Pea green\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Output Points:\u003c\/strong\u003e 8, DC-coupled outputs with commoned return\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResolution:\u003c\/strong\u003e 12 bits\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Current Range:\u003c\/strong\u003e 4–20 mA (+6% over-range)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Over-Range Capability:\u003c\/strong\u003e 2–21.2 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Accuracy:\u003c\/strong\u003e Less than 0.25% of Full Scale Range (FSR) (0–21.2 mA), from 0°C to 60°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExternal Loop Power:\u003c\/strong\u003e\u003cul\u003e\n\u003cli\u003eMaximum: +42.5 VDC\u003c\/li\u003e\n\u003cli\u003eNominal: +24 VDC (reverse voltage protected)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Loop Power Requirement:\u003c\/strong\u003e\u003cul\u003e\n\u003cli\u003e250 Ω load: \u0026gt; 20V (1 A minimum)\u003c\/li\u003e\n\u003cli\u003e500 Ω load: \u0026gt; 25V (1 A minimum)\u003c\/li\u003e\n\u003cli\u003e750 Ω load: \u0026gt; 30V (1 A minimum)\u003c\/li\u003e\n\u003cli\u003e1000 Ω load: \u0026gt; 35V (1 A minimum)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Over-Range Protection:\u003c\/strong\u003e +42.5 VDC continuous, 0 VDC continuous\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitch Time on Channel Failure:\u003c\/strong\u003e 10 ms (typical), 20 ms (maximum)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStatus Indicator:\u003c\/strong\u003e\u003cul\u003e\n\u003cli\u003eModule Status: Pass, Fault, Active, Load\u003c\/li\u003e\n\u003cli\u003eLoop Power Status (Pwr1, Pwr2): Detects loop power presence (\u0026gt; 20 VDC), not the adequacy for the attached load\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Triconex","offers":[{"title":"Default Title","offer_id":49244189688090,"sku":"3805E","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/4351B_1_79fe1cba-8db0-4055-95d0-abccfb4ace88.jpg?v=1719380565"},{"product_id":"do3401-tricone-do-3401-digital-output-module","title":"DO3401 Tricone DO 3401 Digital Output Module","description":"\u003ch3\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Outputs\u003c\/strong\u003e: 16\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Type\u003c\/strong\u003e: Solid-state, MOSFET\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Rating\u003c\/strong\u003e: 2A @ 30VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Voltage Range\u003c\/strong\u003e: 0-30VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput On-State Resistance\u003c\/strong\u003e: 0.3Ω\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Off-State Leakage\u003c\/strong\u003e: 100µA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse Time\u003c\/strong\u003e: \u0026lt;10ms\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation\u003c\/strong\u003e: 500VDC channel-to-channel, 1500VDC channel-to-chassis\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Consumption\u003c\/strong\u003e: 6W\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: 0°C to 60°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e: -40°C to 85°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity\u003c\/strong\u003e: 10-95% non-condensing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions\u003c\/strong\u003e: 10.16 x 27.94 x 27.94 cm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight\u003c\/strong\u003e: 3.5 kg\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Triconex","offers":[{"title":"Default Title","offer_id":49257869934874,"sku":"DO3401","price":39.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/DO3401_5.jpg?v=1719497101"},{"product_id":"4211-invensys-triconex-remote-extender-module","title":"4211 | Invensys Triconex Remote Extender Module","description":"\u003ch3\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply\u003c\/strong\u003e: 24 VDC (18-32 VDC range)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions\u003c\/strong\u003e: 10.40\" x 11.40\" x 4.00\" (264 mm x 290 mm x 102 mm)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight\u003c\/strong\u003e: 6.6 lbs (3 kg)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: 0°C to 60°C (32°F to 140°F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e: -40°C to 85°C (-40°F to 185°F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e: 5% to 95%, non-condensing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting\u003c\/strong\u003e: DIN rail or panel mounting\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eI\/O Modules Supported\u003c\/strong\u003e: Analog, Digital, Specialty (e.g., RTD, Thermocouple, etc.)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication\u003c\/strong\u003e: Triconex proprietary protocol, Modbus TCP\/IP\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Triconex","offers":[{"title":"Default Title","offer_id":49257889923354,"sku":"4211","price":48.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/4210_2_1d92bd4a-6663-4fd6-b3b9-021644424c25.jpg?v=1719497269"},{"product_id":"3604e-triconex-digital-output-module","title":"3604E | Triconex | Digital Output Module","description":"\u003ch3\u003e\u003cstrong\u003eOverview of Triconex 3604E\u003c\/strong\u003e\u003c\/h3\u003e\u003cp\u003eThe \u003cstrong\u003eTriconex 3604E\u003c\/strong\u003e is a high-performance, high-reliability digital output module developed by Invensys\/Consolidated Controls. This module employs Triple Modular Redundancy (TMR) technology, offering industry-leading reliability. The Triconex 3604E is widely used in industrial automation systems requiring high reliability and redundancy, such as oil and gas, chemical processing, and nuclear power plants.\u003c\/p\u003e\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eType:\u003c\/strong\u003e Digital Output Module\u003cbr\u003e\u003cstrong\u003eNumber of Channels:\u003c\/strong\u003e 16\u003cbr\u003e\u003cstrong\u003eVoltage:\u003c\/strong\u003e 24VDC\u003cbr\u003e\u003cstrong\u003eCurrent:\u003c\/strong\u003e 2A\u003cbr\u003e\u003cstrong\u003eIsolation:\u003c\/strong\u003e Optical Isolation\u003cbr\u003e\u003cstrong\u003eResponse Time:\u003c\/strong\u003e \u0026lt; 1ms\u003cbr\u003e\u003cstrong\u003eCertifications:\u003c\/strong\u003e CE, ATEX, IECEx\u003cbr\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e 19-inch rack-mountable\u003c\/p\u003e\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eTriple Modular Redundancy (TMR) Technology:\u003c\/strong\u003e Provides 99.9999% reliability.\u003cbr\u003e\u003cstrong\u003eHot-Swappable Design:\u003c\/strong\u003e Allows maintenance without interrupting operations.\u003cbr\u003e\u003cstrong\u003eMultiple Communication Interfaces Supported:\u003c\/strong\u003e Including Modbus, DNP3, and OPC.\u003cbr\u003e\u003cstrong\u003eReal-Time Monitoring and Diagnostic Functions\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eCompliance with Various Industry Standards\u003c\/strong\u003e\u003c\/p\u003e\u003ch3\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eOil and Gas\u003c\/li\u003e\n\u003cli\u003eChemical Processing\u003c\/li\u003e\n\u003cli\u003ePower Generation\u003c\/li\u003e\n\u003cli\u003eNuclear Power\u003c\/li\u003e\n\u003cli\u003eWater Treatment\u003c\/li\u003e\n\u003cli\u003eRail Transportation\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003e\u003cstrong\u003eAdvantages\u003c\/strong\u003e\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eHigh Reliability:\u003c\/strong\u003e\u003cbr\u003eThe Triconex 3604E employs TMR technology to offer industry-leading reliability. This technology ensures normal system operation by using three identical channels, so even if one channel fails, the other two can maintain system functionality.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eHigh Availability:\u003c\/strong\u003e\u003cbr\u003eThe Triconex 3604E's hot-swappable design allows maintenance without interrupting operations, enabling the system to run 24\/7 without downtime.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eEase of Integration:\u003c\/strong\u003e\u003cbr\u003eSupporting multiple communication interfaces, including Modbus, DNP3, and OPC, the Triconex 3604E can be easily integrated with other devices and systems.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eEase of Maintenance:\u003c\/strong\u003e\u003cbr\u003eWith real-time monitoring and diagnostic functions, users can quickly understand the module's operational status, identify, and resolve issues promptly.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCompliance with Standards:\u003c\/strong\u003e\u003cbr\u003eThe Triconex 3604E complies with various industry standards, including CE, ATEX, and IECEx.\u003c\/p\u003e","brand":"Triconex","offers":[{"title":"Default Title","offer_id":49257907978522,"sku":"3604E","price":89.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/3008_1_8b617f1a-0d83-4598-9b50-21019c5df3c4.jpg?v=1719497400"},{"product_id":"4119a-invensys-triconex-enhanced-intelligent-module","title":"4119A Invensys Triconex Enhanced Intelligent Module","description":"\u003ch3\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcessor\u003c\/strong\u003e: 32-bit microcontroller\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMemory\u003c\/strong\u003e:\n\u003cul\u003e\n\u003cli\u003eProgram Memory: 256 kB\u003c\/li\u003e\n\u003cli\u003eData Memory: 128 kB\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eI\/O Capacity\u003c\/strong\u003e: Up to 64 I\/O points per module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication Interfaces\u003c\/strong\u003e: Modbus RTU, Ethernet\/IP, Profibus-DP\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply\u003c\/strong\u003e: 24 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: -40°C to 70°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions\u003c\/strong\u003e: 280 mm x 233 mm x 104 mm\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Triconex","offers":[{"title":"Default Title","offer_id":49257923346714,"sku":"4119A","price":89.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/4351B_3_7a79653f-67cb-414d-8e6f-e7d4be04af6e.jpg?v=1719497502"},{"product_id":"triconex-4352b-tricon-communication-module","title":"Triconex 4352B Tricon Communication Module","description":"\u003ch3\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/h3\u003e\u003cp\u003eThe Triconex Model 4352B is a communication module used in Triconex safety systems. It is designed to facilitate reliable communication between the Tricon system and various external devices and networks. This module features two fiber-optic Ethernet ports and supports a range of communication protocols, making it suitable for integration into complex safety instrumented systems.\u003c\/p\u003e\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eModel Number:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e4352B\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eSerial Ports:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e4 RS-232\/RS-485 ports\u003c\/li\u003e\n\u003cli\u003eDB-9 connectors\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eNetwork Ports:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e2 fiber-optic Ethernet ports\u003c\/li\u003e\n\u003cli\u003eMT-RJ connectors with 62.5\/125 µm fiber cables\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003ePort Isolation:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e500 VDC\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eSupported Protocols:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eTriStation\u003c\/li\u003e\n\u003cli\u003eModbus\u003c\/li\u003e\n\u003cli\u003eTCP\/IP\u003c\/li\u003e\n\u003cli\u003eICMP\u003c\/li\u003e\n\u003cli\u003eSNTP\u003c\/li\u003e\n\u003cli\u003eTSAA (with support for IP Multicast)\u003c\/li\u003e\n\u003cli\u003eTrimble GPS\u003c\/li\u003e\n\u003cli\u003eEmbedded OPC Server\u003c\/li\u003e\n\u003cli\u003ePeer-to-Peer (UDP\/IP)\u003c\/li\u003e\n\u003cli\u003ePeer-to-Peer Time Synchronization\u003c\/li\u003e\n\u003cli\u003eJet Direct (network printing)\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eModbus Functions Supported:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e01 — Read Coil Status\u003c\/li\u003e\n\u003cli\u003e02 — Read Input Status\u003c\/li\u003e\n\u003cli\u003e03 — Read Holding Registers\u003c\/li\u003e\n\u003cli\u003e04 — Read Input Registers\u003c\/li\u003e\n\u003cli\u003e05 — Modify Coil Status\u003c\/li\u003e\n\u003cli\u003e06 — Modify Register Content\u003c\/li\u003e\n\u003cli\u003e07 — Read Exception Status\u003c\/li\u003e\n\u003cli\u003e08 — Loopback Diagnostic Test\u003c\/li\u003e\n\u003cli\u003e15 — Force Multiple Coils\u003c\/li\u003e\n\u003cli\u003e16 — Preset Multiple Registers\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eCommunication Speed:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eCopper Ethernet ports: 10\/100 Mbps\u003c\/li\u003e\n\u003cli\u003eFiber Ethernet ports: 100 Mbps\u003c\/li\u003e\n\u003cli\u003eSerial ports: up to 115.2 Kbps per port\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eStatus Indicators:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003ePASS\u003c\/li\u003e\n\u003cli\u003eFAULT\u003c\/li\u003e\n\u003cli\u003eACTIVE\u003c\/li\u003e\n\u003cli\u003eFIRM\u003c\/li\u003e\n\u003cli\u003eLINK (1 per network port)\u003c\/li\u003e\n\u003cli\u003eTX (Transmit) — 1 per port\u003c\/li\u003e\n\u003cli\u003eRX (Receive) — 1 per port\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eModule Layout:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eNET 1 (Copper or Fiber Ethernet)\u003c\/li\u003e\n\u003cli\u003eNET 2 (Copper or Fiber Ethernet)\u003c\/li\u003e\n\u003cli\u003eSerial Port #1 (for GPS or Modbus interface)\u003c\/li\u003e\n\u003cli\u003eSerial Port #2 (for Modbus interface)\u003c\/li\u003e\n\u003cli\u003eSerial Port #3 (for Modbus interface)\u003c\/li\u003e\n\u003cli\u003eSerial Port #4 (for TriStation 1131 or Modbus interface)\u003c\/li\u003e\n\u003cli\u003eDebug Port (for Triconex use)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Triconex","offers":[{"title":"Default Title","offer_id":49263909208346,"sku":"4352B","price":30.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/3720_3_e50c9d5a-937c-44f3-942d-1a08848def1b.jpg?v=1719567445"},{"product_id":"triconex-3674-digital-output-module","title":"Triconex 3674 Digital Output Module","description":"\u003ch3\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/h3\u003e\u003cp\u003eThe Triconex 3674 module is a digital output module that produces discrete output signals of 24 VDC. It is designed to be used in high-reliability applications where safety and performance are critical. This module is part of the Tricon family, which is known for its robust and fault-tolerant control systems.\u003c\/p\u003e\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eModel Number:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e3674\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eOutput Characteristics:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eVoltage: 24 VDC\u003c\/li\u003e\n\u003cli\u003eCurrent: Standard load capability with diagnostic coverage\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eEnvironmental and EMC Specifications:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eThe Triconex 3674 module must be housed in an appropriate NEMA-rated enclosure to protect against dust, corrosive atmospheres, or falling debris.\u003c\/li\u003e\n\u003cli\u003eThe module is designed to operate within a wide range of environmental conditions, making it suitable for various industrial applications.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eDiagnostics:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003eThe module includes extensive diagnostic coverage of the field circuit and load device to ensure operational integrity and reliability.\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eMechanical Keying:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003eEach slot in the Tricon system is mechanically keyed to correspond with a specific type of module, preventing improper installation.\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003ePower Supply Requirements:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003eThe module is compatible with the power modules that provide logic power to the main, expansion, or RXM chassis. Power supply models include 24 VDC, 115 VAC, and 230 VAC versions, with a power rating of 175 watts at 60°C.\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eMounting and Enclosures:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003eTriconex offers various industry-standard enclosures for mounting Tricon chassis. These enclosures provide necessary protection and support for the modules.\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eCommunication Interfaces:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003eThe module supports communication via several interfaces, including RS-232, RS-485, Ethernet (802.3), and protocols such as Modbus TCP and OPC. This ensures seamless integration with other systems and devices.\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eReliability Features:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003eThe Triconex 3674 module is designed for high-reliability applications, incorporating features like online replacement capability and system diagnostic indicators to ensure continuous operation.\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eDiagnostic Indicators:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003ePASS\u003c\/li\u003e\n\u003cli\u003eFAULT\u003c\/li\u003e\n\u003cli\u003eALARM\u003c\/li\u003e\n\u003cli\u003eTEMP\u003c\/li\u003e\n\u003cli\u003eBAT LOW\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eThese indicators provide real-time status information and alert operators to any issues that may arise, ensuring prompt maintenance and troubleshooting.\u003c\/p\u003e","brand":"Triconex","offers":[{"title":"Default Title","offer_id":49268483916058,"sku":"3674","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/3624_4fd6d502-3b82-4f6f-9a42-5507fbb22123.jpg?v=1719651048"},{"product_id":"triconex-3664-digital-output-module","title":"Triconex 3664 Digital Output Module","description":"\u003ch2\u003eTriconex 3664 Digital Output Modules 24 VDC Opto-Isolated, Commoned Dual 3664 32\u003c\/h2\u003e\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e: 3664\/3674\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e: 24 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType\u003c\/strong\u003e: Dual, serial (recommended for de-energize-to-trip control programs)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Signals\u003c\/strong\u003e: 32, commoned\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Range\u003c\/strong\u003e: 16-30 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Voltage\u003c\/strong\u003e: 36 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Drop\u003c\/strong\u003e: \u0026lt; 1.5 VDC, typical\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Module Load\u003c\/strong\u003e: \u0026lt; 10 watts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Ratings, Maximum\u003c\/strong\u003e:\n\u003cul\u003e\n\u003cli\u003e2A per point\u003c\/li\u003e\n\u003cli\u003e10A surge per 10 ms\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoad Leakage\u003c\/strong\u003e: 2 mA maximum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFuses (on Field Termination)\u003c\/strong\u003e: n\/a—self-protecting\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePoint Isolation\u003c\/strong\u003e: 1500 VDC minimum\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eDiagnostic Indicators\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\u003cp\u003e\u003cstrong\u003eON or OFF State\u003c\/strong\u003e\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003e\u003cstrong\u003eModule Status\u003c\/strong\u003e\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eField Alarm\u003c\/strong\u003e:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e1 per point\u003c\/li\u003e\n\u003cli\u003ePASS, FAULT, ACTIVE\u003c\/li\u003e\n\u003cli\u003eLOAD\/FUSE\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003e\u003cstrong\u003eLoad Alarm\u003c\/strong\u003e: output stuck-ON 3664 — Stuck-ON point, all others commanded state - ON or OFF\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003e\u003cstrong\u003eColor Code\u003c\/strong\u003e: Dark Blue\u003c\/p\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eField Termination Options\u003c\/h3\u003e\u003cp\u003eMatch your I\/O module number in the first column with termination options on the right. An I\/O module can be wired to a maximum of two termination panels, which may be of two different types—for example, commoned and non-commoned.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eModule Part #\u003c\/strong\u003e: 3664\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Description\u003c\/strong\u003e: Dual DO, 24 VDC, self-protected, 32 pts.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommoned Term Panels\u003c\/strong\u003e: 9662-610\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNon-Common. Term Panels\u003c\/strong\u003e: n\/a\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBasic Term Panels\u003c\/strong\u003e: 9653-610\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNonincendive Term Panels\u003c\/strong\u003e: 9671-610\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFanned-out Cables\u003c\/strong\u003e: 9101-010\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBypass Panels\u003c\/strong\u003e: n\/a\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eERT Loop-Back Cables\/Panels\u003c\/strong\u003e: 9671-810\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eField Termination Options Dimensions\u003c\/h4\u003e\u003cp\u003e\u003cstrong\u003ePanel Model\u003c\/strong\u003e: 9662-610\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth (across DIN rail)\u003c\/strong\u003e: 4.5 in (11.43 cm)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLength (along DIN rail)\u003c\/strong\u003e: 5 in (12.7 cm)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight (out from DIN rail)\u003c\/strong\u003e: 4.25 in (10.795 cm)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003ePart Number Cross-Reference\u003c\/h4\u003e\u003cp\u003eThis table identifies the ETA part number and cable part number for each termination panel model.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eModel #\u003c\/strong\u003e: 9662-610\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eETA\u003c\/strong\u003e: 3000520-390\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable\u003c\/strong\u003e: 4000094-310\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Triconex","offers":[{"title":"Default Title","offer_id":49268491616538,"sku":"3664","price":77.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/3624_87a46354-707c-41ee-a163-dc1f390f5db9.jpg?v=1719651191"},{"product_id":"triconex-3706-analog-input-module","title":"Triconex 3706 Analog input Module","description":"\u003ch2\u003e\u003cstrong\u003eTriconex 3706 Thermocouple Input Module - Triple-Redundant Safety Solution for Hazardous Environments\u003c\/strong\u003e\u003c\/h2\u003e\u003ch3\u003e\u003cstrong\u003eCritical Safety Protection\u003c\/strong\u003e\u003c\/h3\u003e\u003cp\u003eThe \u003cstrong\u003eTriconex 3706\u003c\/strong\u003e analog input module provides \u003cstrong\u003etriple-redundant\u003c\/strong\u003e temperature monitoring for Safety Instrumented Systems (SIS). Perfect for oil\/gas, chemical, and power plants where \u003cstrong\u003efailure is not an option\u003c\/strong\u003e.\u003c\/p\u003e\u003ch3\u003e\u003cstrong\u003eKey Safety Features\u003c\/strong\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTriple-redundant\u003c\/strong\u003e architecture for maximum reliability\u003c\/li\u003e\n\u003cli\u003eAutomatic \u003cstrong\u003efault detection\u003c\/strong\u003e (open\/short circuits, voltage issues)\u003c\/li\u003e\n\u003cli\u003eBuilt-in \u003cstrong\u003ecold junction compensation\u003c\/strong\u003e (0-50°C range)\u003c\/li\u003e\n\u003cli\u003eAdvanced \u003cstrong\u003esignal filtering\u003c\/strong\u003e for noise reduction\u003c\/li\u003e\n\u003cli\u003eSupports \u003cstrong\u003e8 thermocouple types\u003c\/strong\u003e (J,K,T,E,C,R,S,B)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003e\u003cstrong\u003ePrecision Performance\u003c\/strong\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWide measurement range:\u003c\/strong\u003e -200°C to +1800°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh accuracy:\u003c\/strong\u003e ±0.1% of full scale\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCrisp resolution:\u003c\/strong\u003e 0.1°C increments\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFast response:\u003c\/strong\u003e 2 second update rate\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProgrammable filtering\u003c\/strong\u003e for process optimization\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003e\u003cstrong\u003eTechnical Details\u003c\/strong\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e Triconex 3706\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Type:\u003c\/strong\u003e Thermocouple (TC)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCold Junction Range:\u003c\/strong\u003e 0°C to 50°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFault Detection:\u003c\/strong\u003e Open circuit, short circuit, over\/under voltage\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArchitecture:\u003c\/strong\u003e Triple modular redundant (TMR)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertifications:\u003c\/strong\u003e SIL-rated for safety systems\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003e\u003cstrong\u003eWhy Professionals Choose Triconex 3706\u003c\/strong\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eProven reliability\u003c\/strong\u003e in explosive environments\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSimplifies compliance\u003c\/strong\u003e with safety standards\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReduces downtime\u003c\/strong\u003e with instant fault alerts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFuture-proof\u003c\/strong\u003e with multiple TC support\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003e\u003cstrong\u003eSafety FAQs\u003c\/strong\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What safety certification does it have?\u003c\/strong\u003e\u003cbr\u003eA: SIL-rated for use in safety instrumented systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: How many thermocouples per module?\u003c\/strong\u003e\u003cbr\u003eA: Typically 8-16 channels per rack module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Can it detect broken thermocouples?\u003c\/strong\u003e\u003cbr\u003eA: Yes, instant open-circuit detection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Is calibration required?\u003c\/strong\u003e\u003cbr\u003eA: Factory calibrated, but field verification recommended\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What's the module lifespan?\u003c\/strong\u003e\u003cbr\u003eA: 10+ years typical in industrial environments\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Triconex","offers":[{"title":"Default Title","offer_id":49269967618330,"sku":"3706","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/3624_3_4fa5b968-1da0-482f-b7db-e367c872ab28.jpg?v=1719675027"},{"product_id":"3603b-invensys-triconex-digital-output-module","title":"3603B Invensys Triconex Digital Output Module","description":"\u003ch3\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Voltage:\u003c\/strong\u003e 120 VDC nominal (90-150 VDC range)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Voltage:\u003c\/strong\u003e 120 VDC nominal\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Signals:\u003c\/strong\u003e 16 non-commoned\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Range:\u003c\/strong\u003e 90-150 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Current:\u003c\/strong\u003e 2A per output, 10A total\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Current Ratings:\u003c\/strong\u003e 0.8A per point, 4A surge\/10 ms\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEfficiency:\u003c\/strong\u003e Typical 85%\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e 0°C to 60°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e -40°C to 85°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (W x H x D):\u003c\/strong\u003e 48.3 cm x 57.8 cm x 45.1 cm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 2.5 kg\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Triconex","offers":[{"title":"Default Title","offer_id":49274551206170,"sku":"3603B","price":200.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/TRICONEX3664_2.jpg?v=1719756503"},{"product_id":"3351-invensys-triconex-ai3351-analog-input-module","title":"3351 Invensys Triconex AI3351 Analog Input Module","description":"\u003ch3\u003e\u003cstrong\u003eFeature Specifications:\u003c\/strong\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePoints:\u003c\/strong\u003e 32, commoned\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNominal Input Current:\u003c\/strong\u003e 4–20 mA DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperational Current Range:\u003c\/strong\u003e 2–22 mA DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAbsolute Maximum Field Voltage:\u003c\/strong\u003e 33 V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAbsolute Maximum Reverse Field Voltage:\u003c\/strong\u003e –0.6 V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAbsolute Maximum Input Current:\u003c\/strong\u003e 50 mA DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Bandwidth (3dB):\u003c\/strong\u003e 16 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSource Impedance:\u003c\/strong\u003e 180 Ω\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Impedance (with baseplate):\u003c\/strong\u003e 250 Ω\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eI to V Resistor:\u003c\/strong\u003e 100 Ω, ±0.01%\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResolution:\u003c\/strong\u003e 12 bits\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAbsolute Error:\u003c\/strong\u003e 0.15% of full scale (20 mA)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiagnostic:\u003c\/strong\u003e Force-to-value diagnostic (FVD)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eScan Time:\u003c\/strong\u003e \u0026lt;1 ms for all 32 points\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFunctional-to-Protective-Earth Isolation:\u003c\/strong\u003e 500 V DC, minimum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFunctional-to-Functional-Earth (Logic) Isolation:\u003c\/strong\u003e 800 V DC, minimum\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Triconex","offers":[{"title":"Default Title","offer_id":49274767900954,"sku":"AI3351","price":122.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/AI3351.jpg?v=1719758197"},{"product_id":"3301-triconex-di3301-digital-input-module","title":"3301 Triconex DI3301 Digital Input Module","description":"\u003ch3\u003e\u003cstrong\u003eFeature Specifications:\u003c\/strong\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePoints:\u003c\/strong\u003e 32, commoned\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNominal Input Voltage:\u003c\/strong\u003e 24 V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperational Voltage Range:\u003c\/strong\u003e 15–30 V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAbsolute Maximum Input Voltage:\u003c\/strong\u003e 33 V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAbsolute Maximum Reverse Input Voltage:\u003c\/strong\u003e –0.6 V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Delay:\u003c\/strong\u003e \u0026lt;10 ms, On to Off or Off to On\n\u003cul\u003e\u003cli\u003eTC = 6.4 ms, –3dB @ 25 Hz\u003cbr\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Power:\u003c\/strong\u003e\u003cul\u003e\n\u003cli\u003e0.2 W\/pt @ 24 V DC\u003c\/li\u003e\n\u003cli\u003e0.5 W\/pt @ 33 V DC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Threshold:\u003c\/strong\u003e\u003cul\u003e\n\u003cli\u003e0–5 V DC = Off region\u003c\/li\u003e\n\u003cli\u003e6–14 V DC = transition region\u003c\/li\u003e\n\u003cli\u003e15–30 V DC = On region\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiagnostic (Loss of View):\u003c\/strong\u003e Force-to-value diagnostic (FVD), \u0026lt;2 ms\/test\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Input Toggle Rate to Maintain Diagnostic Fault Coverage:\u003c\/strong\u003e \u0026lt;20\/sec\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFVD Off-State Glitch:\u003c\/strong\u003e\u003cul\u003e\n\u003cli\u003eDuration: \u0026lt;2 ms\u003c\/li\u003e\n\u003cli\u003eMagnitude: ≈36% test voltage\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Impedance (0–5 V DC):\u003c\/strong\u003e ≈100 kΩ\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eADC Scan Time:\u003c\/strong\u003e \u0026lt;1 ms for all 32 points\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFunctional-to-Protective-Earth Isolation:\u003c\/strong\u003e 500 V DC, minimum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFunctional-to-Functional-Earth (Logic) Isolation:\u003c\/strong\u003e 800 V DC, minimum\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Triconex","offers":[{"title":"Default Title","offer_id":49274798768410,"sku":"DI3301","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/DI3301.jpg?v=1719758424"},{"product_id":"3381-triconex-pi3381-pulse-input-module","title":"3381 Triconex PI3381 Pulse Input Module","description":"\u003ch3\u003e\u003cstrong\u003eFeature Specifications:\u003c\/strong\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePoints:\u003c\/strong\u003e 6, channel-isolated, commoned ground\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Type:\u003c\/strong\u003e Differential\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor Compatibility:\u003c\/strong\u003e Magnetic, active, open collector\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Operating Voltage:\u003c\/strong\u003e ±33 V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMinimum Operating Voltage:\u003c\/strong\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDifferential:\u003c\/strong\u003e 500 mV P-P (2 Hz to 32,000 Hz), 1 V P-P (0.5 Hz to 2 Hz)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle-ended:\u003c\/strong\u003e 1 V P-P (2 Hz to 32,000 Hz), 2 V P-P (0.5 Hz to 2 Hz)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpeed Range:\u003c\/strong\u003e 0 to 32,000 RPM\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Frequency Range:\u003c\/strong\u003e 0.5 Hz to 32 kHz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDuty Cycle:\u003c\/strong\u003e 20% to 80%, or 10 µs minimum pulse width\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Continuous Slew Rate:\u003c\/strong\u003e\u003cul\u003e\n\u003cli\u003e4,000 Hz\/sec with 60 gear teeth\u003c\/li\u003e\n\u003cli\u003e4,000 RPM\/sec with 60 gear teeth\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Gear Teeth:\u003c\/strong\u003e 1–255\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTermination Resistor:\u003c\/strong\u003e Baseplate configurable\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePull-up Resistor:\u003c\/strong\u003e Baseplate configurable\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResolution:\u003c\/strong\u003e 24 bits\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAbsolute Error:\u003c\/strong\u003e\u003cul\u003e\n\u003cli\u003e± 0.01% (2,000 to 32,000 Hz)\u003c\/li\u003e\n\u003cli\u003e± 0.1% (0.5 to 2,000 Hz)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurement Algorithm:\u003c\/strong\u003e Gear multiple tracking\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiagnostic:\u003c\/strong\u003e Precision reference test\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMinimum Scan Update Rate:\u003c\/strong\u003e 20 ms\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFunctional-to-Protective-Earth Isolation:\u003c\/strong\u003e 500 V DC, minimum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFunctional-to-Functional-Earth (Logic) Isolation:\u003c\/strong\u003e 800 V DC, minimum\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Triconex","offers":[{"title":"Default Title","offer_id":49274841530650,"sku":"PI3381","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/PI3381.jpg?v=1719758730"},{"product_id":"3201-invensys-triconex-cm3201-communication-module","title":"3201 Invensys Triconex CM3201 Communication Module","description":"\u003ch3\u003e\u003cstrong\u003eFeature Specification:\u003c\/strong\u003e\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eLogic Power:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNominal Input Voltage:\u003c\/strong\u003e 24 V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpecified Operational Voltage Range:\u003c\/strong\u003e 24 V DC ±15% or +20% + 5% AC ripple (19.2 to 30 V DC)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLogic Power (without MAUs):\u003c\/strong\u003e 8 W maximum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e10 Mb AUI-type MAU:\u003c\/strong\u003e 6 W maximum additional per MAU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e100 Mb MII-type MAU:\u003c\/strong\u003e 3.75 W maximum additional per MAU\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAbsolute Maximum Input Voltage:\u003c\/strong\u003e 33 V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAbsolute Maximum Reverse Input Voltage:\u003c\/strong\u003e –0.6 V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Power Interruption Time from Nominal Value:\u003c\/strong\u003e 1 ms maximum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRepetition Rate:\u003c\/strong\u003e 1 sec minimum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReverse Current Isolation Input to Input:\u003c\/strong\u003e 500 µA maximum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInrush Current per Input:\u003c\/strong\u003e 2.4 A maximum, typically 1.2 A for 50 ms\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShort Circuit Current Limit per Input:\u003c\/strong\u003e 2.4 A maximum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFunctional-to-Logic Ground Isolation:\u003c\/strong\u003e 0 V, no isolation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtective-to-Functional-Earth Isolation:\u003c\/strong\u003e 500 V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e+12 V AUI Output Power:\u003c\/strong\u003e 12 V ±10%, 6 W maximum, current limited\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e+5 V MII Output Power:\u003c\/strong\u003e 5 V ±5%, 3.75 W maximum, current limited\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eCommunication Ports - Network Ports:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModbus Ports:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e3 optically isolated RS-232\/485 ports, configurable from TriStation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector:\u003c\/strong\u003e DB-9-pin DTE standard, shielded, located on baseplate\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRS-232 Maximum Cable Length:\u003c\/strong\u003e 15 m (50 ft)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRS-485 Maximum Cable Length:\u003c\/strong\u003e 1.2 km (4,000 ft)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupported Transmission Rates (bps):\u003c\/strong\u003e 1200, 2400, 4800, 9600, 19.2 K, 38.4 K, 57.6 K, 115.2 K\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtocols:\u003c\/strong\u003e Master or slave, RTU and ASCII modes, optional parity, 1 stop bit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSerial Port Galvanic Isolation:\u003c\/strong\u003e 500 V DC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e10BaseT Network Port:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eEthernet 10 Mbps, protocol-configurable from TriStation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector:\u003c\/strong\u003e RJ-45 standard, shielded, located on baseplate\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Cable Length:\u003c\/strong\u003e 100 m, using Category 5 twisted-pair cable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e100BaseTX Ethernet Port:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e100 or 10 Mbps, speed auto-selected, configurable from TriStation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector:\u003c\/strong\u003e RJ-45 standard, shielded, located on baseplate\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Cable Length:\u003c\/strong\u003e 30 m, using Category 5 twisted-pair cable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003e\u003cstrong\u003eProtocols (Both Network Ports):\u003c\/strong\u003e JetDirect Network Printer Server DLC\/LLC, TCP\/IP, Time synchronization Triconex Peer-to-Peer TriStation TSAA\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003e\u003cstrong\u003eNetwork Address:\u003c\/strong\u003e Derived from MP Baseplate address plug\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003e\u003cstrong\u003eGalvanic Isolation:\u003c\/strong\u003e 500 V DC\u003c\/p\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Triconex","offers":[{"title":"Default Title","offer_id":49275071037722,"sku":"CM3201","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/CM3201_357eafcf-9a24-46bc-b107-e1e8fe8f2941.jpg?v=1719761677"},{"product_id":"invensys-triconex-ai2351-7400210-010-analog-input-baseplate","title":"Invensys Triconex AI2351 7400210-010 Analog Input Baseplate","description":"\u003ch3\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAnalog Input Channels:\u003c\/strong\u003e 8 max\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Ranges:\u003c\/strong\u003e 4-20 mA or 0-10 V DC (software configurable)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Impedance:\u003c\/strong\u003e\u003cul\u003e\n\u003cli\u003e4-20 mA: 250 Ω\u003c\/li\u003e\n\u003cli\u003e0-10 V DC: 1 MΩ\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy:\u003c\/strong\u003e ±0.1% of full scale\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResolution:\u003c\/strong\u003e 12-bit (1 in 4096)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation:\u003c\/strong\u003e 1500 Vrms between channels and system\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Consumption:\u003c\/strong\u003e 5 W max\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e 0°C to 60°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (H x W x D):\u003c\/strong\u003e 345 mm x 160 mm x 35 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 1.5 kg\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Triconex","offers":[{"title":"Default Title","offer_id":49275088732442,"sku":"AI2351","price":200.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/7400210-010AI2351.jpg?v=1719762244"},{"product_id":"mp2101-triconex-7400207-001-main-processor-baseplate","title":"MP2101 Triconex 7400207-001 Main Processor Baseplate","description":"\u003ch3\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel Number:\u003c\/strong\u003e 7400207-001\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcessor:\u003c\/strong\u003e MP2101 Main Processor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMemory:\u003c\/strong\u003e 128 MB RAM, 256 MB Flash\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication Interfaces:\u003c\/strong\u003e Ethernet, Serial Ports\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply:\u003c\/strong\u003e 24 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -40°C to +70°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 10.2 x 6.7 x 1.2 inches (259 x 170 x 30 mm)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 2.6 lbs (1.2 kg)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertifications:\u003c\/strong\u003e\u003cul\u003e\n\u003cli\u003eIEC 61508 SIL 3\u003c\/li\u003e\n\u003cli\u003eISA S84.01\u003c\/li\u003e\n\u003cli\u003eUL\u003c\/li\u003e\n\u003cli\u003eCE\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Triconex","offers":[{"title":"Default Title","offer_id":49275094171930,"sku":"MP2101","price":120.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/MP21017400207-001_1.jpg?v=1719762382"},{"product_id":"di2301-triconex-7400208c-020-digital-input-baseplate","title":"DI2301 Triconex 7400208C-020 Digital Input Baseplate","description":"\u003ch3\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Voltage Range:\u003c\/strong\u003e 18-30VDC, 88-132VAC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Signal Types:\u003c\/strong\u003e 24VDC, 120VAC, Dry Contact\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Inputs:\u003c\/strong\u003e 32\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Impedance:\u003c\/strong\u003e\u003cul\u003e\n\u003cli\u003e3.3kΩ (24VDC)\u003c\/li\u003e\n\u003cli\u003e100kΩ (120VAC)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Filter Time:\u003c\/strong\u003e 0-255 ms, configurable\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation Voltage:\u003c\/strong\u003e 1500VAC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e 0°C to 60°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity:\u003c\/strong\u003e 10-95% non-condensing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (HxWxD):\u003c\/strong\u003e 177 mm x 196 mm x 42 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals:\u003c\/strong\u003e UL, CSA, ATEX, IEC 61508 (up to SIL 3)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Triconex","offers":[{"title":"Default Title","offer_id":49275100889370,"sku":"DI2301","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/DI23017400208C-020_1.jpg?v=1719762500"},{"product_id":"ao2481-triconex-7400209-010-analog-output-baseplate","title":"AO2481 Triconex 7400209-010 Analog Output Baseplate","description":"\u003ch3\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel Number:\u003c\/strong\u003e 7400209-010\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e AO2481\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Analog Outputs:\u003c\/strong\u003e 8\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Ranges:\u003c\/strong\u003e 0-20 mA, 4-20 mA, 0-10 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Resolution:\u003c\/strong\u003e 16-bit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Accuracy:\u003c\/strong\u003e ±0.1% of full scale\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse Time:\u003c\/strong\u003e \u0026lt;10 ms\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation:\u003c\/strong\u003e\u003cul\u003e\n\u003cli\u003e250V RMS channel-to-channel\u003c\/li\u003e\n\u003cli\u003e1500V RMS channel-to-system\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply:\u003c\/strong\u003e 24VDC nominal (18-32VDC range)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Consumption:\u003c\/strong\u003e 8W maximum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e 0°C to 60°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e -40°C to 85°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHumidity:\u003c\/strong\u003e 10-95% non-condensing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (H x W x D):\u003c\/strong\u003e 177 mm x 35 mm x 220 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 1.2 kg\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Triconex","offers":[{"title":"Default Title","offer_id":49275126415642,"sku":"AO2481","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/AO24817400209-010_1.jpg?v=1719762661"},{"product_id":"do2401-triconex-7400209-030-digital-output-baseplate","title":"DO2401 Triconex 7400209-030 Digital Output Baseplate","description":"\u003ch3\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e 7400209-030\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel Name:\u003c\/strong\u003e DO2401\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutputs:\u003c\/strong\u003e 24 digital outputs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Current:\u003c\/strong\u003e Up to 2A per output\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Voltage:\u003c\/strong\u003e 24VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e DIN rail\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (H x W x D):\u003c\/strong\u003e 160 mm x 50 mm x 75 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e 0°C to 60°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e -40°C to 85°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRelative Humidity:\u003c\/strong\u003e 5% to 95% non-condensing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompliance:\u003c\/strong\u003e IEC 61508, ISA 84.00.01, ANSI\/ISA 84.00.01\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Triconex","offers":[{"title":"Default Title","offer_id":49275131494682,"sku":"DO2401","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/DO24017400209-030_1.jpg?v=1719762771"},{"product_id":"2201-triconex-7400206-100-cm2201-backplane-module","title":"2201 Triconex 7400206-100 CM2201 Backplane Module","description":"\u003ch3\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 9.35 x 5.75 x 1.03 inches (238 x 146 x 26 mm)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 3.5 lbs (1.6 kg)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply:\u003c\/strong\u003e Redundant 24 VDC input\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Consumption:\u003c\/strong\u003e 15 W maximum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane Interfaces:\u003c\/strong\u003e\u003cul\u003e\n\u003cli\u003e14 module slots\u003c\/li\u003e\n\u003cli\u003eI\/O bus for module-to-module communication\u003c\/li\u003e\n\u003cli\u003eRedundant power supply buses\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e 0°C to 60°C (32°F to 140°F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e -40°C to 85°C (-40°F to 185°F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRelative Humidity:\u003c\/strong\u003e 5% to 95%, non-condensing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShock:\u003c\/strong\u003e 15 g, 11 ms, half-sine wave\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVibration:\u003c\/strong\u003e 1 g, 5-500 Hz\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Triconex","offers":[{"title":"Default Title","offer_id":49275165737242,"sku":"CM2201","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/7400206-100CM2201.jpg?v=1719763268"},{"product_id":"invensys-triconex-tm-4353-tricon-communication-module","title":"Invensys Triconex TM 4353 Tricon Communication Module","description":"\u003ch3\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eSerial Ports:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003e4 RS-232\/RS-485 ports with DB-9 connectors\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eNetwork Ports:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eModel 4351A and 4353: 2 x 10\/100BaseT Ethernet ports with RJ-45 connectors\u003c\/li\u003e\n\u003cli\u003eModel 4352A and 4354: 2 x fiber-optic Ethernet ports with MTRJ connectors, using 62.5\/125 μm fiber cables\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003ePort Isolation: \u003c\/strong\u003e500 VDC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSupported Protocols:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\u003cli\u003eTriStation, Modbus, TCP\/IP, ICMP, SNTP, TSAA, Trimble GPS, Peer-to-Peer, Peer-to-Peer Time Synchronization, Jet Direct (network printing)\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eSupported Modbus Functions:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e01 - Read Coil Status\u003c\/li\u003e\n\u003cli\u003e02 - Read Input Status\u003c\/li\u003e\n\u003cli\u003e03 - Read Holding Registers\u003c\/li\u003e\n\u003cli\u003e04 - Read Input Registers\u003c\/li\u003e\n\u003cli\u003e05 - Modify Coil Status\u003c\/li\u003e\n\u003cli\u003e06 - Modify Register Content\u003c\/li\u003e\n\u003cli\u003e07 - Read Exception Status\u003c\/li\u003e\n\u003cli\u003e08 - Loopback Diagnostic Test\u003c\/li\u003e\n\u003cli\u003e15 - Force Multiple Coils\u003c\/li\u003e\n\u003cli\u003e16 - Preset Multiple Registers\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eCommunication Speeds:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eCopper Ethernet ports: 10\/100 Mbps\u003c\/li\u003e\n\u003cli\u003eFiber Ethernet ports: 100 Mbps\u003c\/li\u003e\n\u003cli\u003eSerial ports: up to 115.2 Kbps per port\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eStatus Indicators:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003ePASS, FAULT, ACTIVE, FIRM\u003c\/li\u003e\n\u003cli\u003eLINK: 1 per network port\u003c\/li\u003e\n\u003cli\u003eTX (Transmit): 1 per port\u003c\/li\u003e\n\u003cli\u003eRX (Receive): 1 per port\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Triconex","offers":[{"title":"Default Title","offer_id":49284633821466,"sku":"4353","price":50.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/3008_1_4ebb694f-4ee7-48f1-a058-934750ad16bb.jpg?v=1719889558"},{"product_id":"3708e-triconex-invensys-analog-input-module","title":"3708E Triconex Invensys Analog Input Module","description":"\u003ch3\u003e\u003cstrong\u003eModel 3708E Overview\u003c\/strong\u003e\u003c\/h3\u003e\u003cp\u003eThe Model 3708E is designed for precise and reliable measurement of thermocouple inputs. It features 16 differential, isolated input signals, providing robust performance in industrial environments. The model supports multiple thermocouple types and ensures high accuracy and reliability through advanced signal processing and diagnostic capabilities.\u003c\/p\u003e\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e16 differential, isolated input signals\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput update rate:\u003c\/strong\u003e 50 ms\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupported thermocouple types:\u003c\/strong\u003e J, K, T, E\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput resistance:\u003c\/strong\u003e 30 MΩ (DC), minimum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommon mode rejection:\u003c\/strong\u003e -90 dB @ 0-60 Hz, minimum and -100 dB @ DC, minimum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNormal mode rejection:\u003c\/strong\u003e -17 dB @ 60 Hz, typical\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommon mode range:\u003c\/strong\u003e ±200 VDC, max\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLeg-to-leg isolation:\u003c\/strong\u003e 20 KΩ, typical\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReference junction compensation range:\u003c\/strong\u003e 32°-140°F (0°-60°C)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiagnostic indicators:\u003c\/strong\u003e PASS, FAULT, ACTIVE, CJ FAULT\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eColor code:\u003c\/strong\u003e Deep Yellow\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Channels:\u003c\/strong\u003e 16 thermocouple inputs, types E, J, K, T\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Range:\u003c\/strong\u003e Programmable, typical ranges:\n\u003cul\u003e\n\u003cli\u003eType E: -270°C to 1000°C\u003c\/li\u003e\n\u003cli\u003eType J: -210°C to 1200°C\u003c\/li\u003e\n\u003cli\u003eType K: -270°C to 1372°C\u003c\/li\u003e\n\u003cli\u003eType T: -270°C to 400°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccuracy:\u003c\/strong\u003e ±0.1% of reading ±0.5°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResolution:\u003c\/strong\u003e 0.1°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Impedance:\u003c\/strong\u003e \u0026gt;10 MΩ\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommon Mode Rejection Ratio:\u003c\/strong\u003e \u0026gt;120 dB\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation Voltage:\u003c\/strong\u003e 1500 Vrms\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply:\u003c\/strong\u003e 10-30 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -40°C to 70°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 114 mm x 115 mm x 25 mm\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Triconex","offers":[{"title":"Default Title","offer_id":49294527267098,"sku":"3708E","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/4351B_2_924bbf72-c641-4c25-b735-664241de68cd.jpg?v=1720055848"},{"product_id":"3009-invensys-triconex-enhanced-main-processor-module","title":"3009 Invensys Triconex Enhanced Main Processor Module","description":"\u003ch3\u003e\u003cstrong\u003eTechnical Specification:\u003c\/strong\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMain Processor:\u003c\/strong\u003e\u003cul\u003e\n\u003cli\u003eQorlQ P1021, dual core processor\u003c\/li\u003e\n\u003cli\u003e32KB L1 cache, 2MB L2 cache\u003c\/li\u003e\n\u003cli\u003e800 MHz clock speed\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMemory:\u003c\/strong\u003e\u003cul\u003e\n\u003cli\u003e256 MB DRAM (without battery backup)\u003c\/li\u003e\n\u003cli\u003e2 MB SRAM (with battery backup)\u003c\/li\u003e\n\u003cli\u003e128 MB Flash PROM\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClock and Calendar:\u003c\/strong\u003e\u003cul\u003e\n\u003cli\u003eBattery backup\u003c\/li\u003e\n\u003cli\u003eTypical drift: ±2 seconds\/day\u003c\/li\u003e\n\u003cli\u003eMaximum drift: ±2.16 seconds\/day\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTriBus Interface:\u003c\/strong\u003e\u003cul\u003e\n\u003cli\u003e32-bit CRC-protected\u003c\/li\u003e\n\u003cli\u003e32-bit DMA, fully isolated\u003c\/li\u003e\n\u003cli\u003eSpeed:\n\u003cul\u003e\n\u003cli\u003eModel 8110 Main Chassis: 25 Mbps\u003c\/li\u003e\n\u003cli\u003eModel 8100-1 Low-Density Main Chassis: 25 Mbps\u003c\/li\u003e\n\u003cli\u003eModel 8120E Enhanced Performance Main Chassis: 1000 Mbps\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSerial Port:\u003c\/strong\u003e\u003cul\u003e\n\u003cli\u003eOptically isolated RS-232 interface on one 9-pin connector\u003c\/li\u003e\n\u003cli\u003e500 VDC isolation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication Interface:\u003c\/strong\u003e\u003cul\u003e\n\u003cli\u003eRS-485 protocol\u003c\/li\u003e\n\u003cli\u003e2 Mbps baud rate\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eI\/O Interface:\u003c\/strong\u003e\u003cul\u003e\n\u003cli\u003eRS-485 protocol\u003c\/li\u003e\n\u003cli\u003e375 Kbps baud rate\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Consumption: \u003c\/strong\u003e14 Watts\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Triconex","offers":[{"title":"Default Title","offer_id":49300340474138,"sku":"3009","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/3008_2_4bddc694-887c-42d4-ada7-365a418318c0.jpg?v=1720183995"},{"product_id":"3625a-invensys-triconex-24vdc-digital-i-o-module","title":"3625A Invensys Triconex 24VDC Digital I\/O Module","description":"\u003ch3\u003e\u003cstrong\u003eTechnical Specification:\u003c\/strong\u003e\u003c\/h3\u003e\u003ch4\u003e\u003cstrong\u003eModel Information\u003c\/strong\u003e\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e 3625A 24V Digital Output Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannels:\u003c\/strong\u003e 32\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSlots:\u003c\/strong\u003e 2 x 16\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Type:\u003c\/strong\u003e Digital Output (DO)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNominal Voltage:\u003c\/strong\u003e 24V DC (19V - 31.2V)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRedundant Supply:\u003c\/strong\u003e Yes, decoupled with diodes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndication:\u003c\/strong\u003e 2 x LED green \"PWR1\", \"PWR2\"\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFuse:\u003c\/strong\u003e 2 x TR5, T 2.0A, exchangeable for primary and redundant supply\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePolarity Reversal Protection:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003e\u003cstrong\u003eAmbient Conditions\u003c\/strong\u003e\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient Temperature:\u003c\/strong\u003e -20°C to +70°C (as per Ex i isolator specification)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e -40°C to +80°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRelative Humidity:\u003c\/strong\u003e ≤ 95% (non-condensing)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003e\u003cstrong\u003eMechanical Data\u003c\/strong\u003e\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e Approx. 320g\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e DIN rail (NS35\/15, NS35\/7.5) or mounting plate (4 x M6 screws)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Position:\u003c\/strong\u003e Horizontal or vertical\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCasing\/Terminal Protection Class:\u003c\/strong\u003e IP00 \/ IP20\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCasing Material:\u003c\/strong\u003e PA 6.6\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFire Protection Class (UL-94):\u003c\/strong\u003e V0\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Triconex","offers":[{"title":"Default Title","offer_id":49300341227802,"sku":"3625A","price":122.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/3704E_2_aa32c9fb-3b67-49d8-8ee9-125b28027c2a.jpg?v=1720181650"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/collections\/Triconex.webp?v=1717144115","url":"https:\/\/www.ubestplc.com\/collections\/invensys-triconex.oembed?page=2","provider":"Ubest Automation Limited","version":"1.0","type":"link"}