Bently Nevada 3300 XL 8mm Extended Cable Hazardous Area Probe
Introducing the 330103-00-05-15-02-05, featuring extended reach for challenging installations. This model combines extra cable length with explosion-proof certification. The 330103-00-05-15-02-05 delivers safety and convenience in one package. Perfect for applications where monitoring equipment is located farther from measurement points.
Review extended cable specifications: Download Extended Cable Details
Technical Specifications
- Brand: Bently Nevada
- Product Series: 3300 XL Extended Reach
- Complete Model: 330103-00-05-15-02-05
- Probe Diameter: 8mm industry standard
- Thread Specification: M10 × 1.0 mm fully threaded
- Unthreaded Length: 0mm (completely threaded)
- Case Length: 50mm compact design
- Cable Length: 1.5 meters (4.9 feet) extended
- Measurement Range: 2.0mm (80 mils) linear
- Optimal Gap Setting: 1.27mm (50 mils)
- Voltage Output: -1 to -17 VDC range
- Standard Output: -9 VDC for vibration monitoring
- Electrical Resistance: 7.73 ± 0.50 Ω (1.5m cable)
- Cable Type: Standard coaxial design
- Connector: Miniature ClickLoc
- Housing Material: 303/304 Stainless Steel
- Tip Material: PPS (Polyphenylene Sulfide)
- Sealing System: Viton O-ring protection
- Temperature Range: -52°C to +177°C
- Unit Weight: 323 g/m (11.4 oz/ft)
- Safety Certifications: CSA, ATEX, IECEx
- Hazard Classification: Class I, Zone 0/1/2
- Protection Level: AEx/Ex ia IIC T5-T1
- Maximum System Cable: 305 meters (1000 feet)
- Humidity Resistance: Less than 3% change at 93% RH
Model Number Breakdown
- 330103: 8mm probe with M10×1 thread
- 00: No unthreaded section
- 05: 50mm total case length
- 15: 1.5 meter extended cable
- 02: Standard ClickLoc connector
- 05: CSA, ATEX, IECEx certifications
Application Questions
-
When is extended cable length beneficial?
When monitors are located farther from measurement points in hazardous areas. -
Does cable length affect electrical resistance?
Yes, 1.5m cable has 7.73Ω resistance versus 7.59Ω for 1.0m cable. -
Can this probe monitor equipment in explosive areas?
Yes, when installed with proper intrinsic safety barriers. -
What applications need compact 50mm cases?
Space-constrained hazardous locations requiring extended cable reach. -
How does temperature affect extended cable performance?
Stable operation across full -52°C to +177°C temperature range.