Siemens SIRIUS 3RW4447-6BC44 Soft Starter
The 3RW4447-6BC44 represents Siemens' advanced motor control technology for industrial applications. This SIRIUS soft starter delivers smooth acceleration and deceleration for three-phase motors. It significantly reduces mechanical stress and extends equipment lifespan.
Core Technical Specifications
- Brand: Siemens
- Model: 3RW4447-6BC44
- Product Line: SIRIUS Soft Starters
- Rated Current: 432A @ 40°C standard circuit
- Inside-Delta Current: 748A @ 40°C
- Motor Power: 250kW standard, 400kW inside-delta
- Operating Voltage: 200-460V AC
- Control Voltage: 230V AC
- Frequency Range: 50-60Hz ±10%
- Dimensions: 432 x 348 x 366 mm
- Weight: 11.53 kg
- Protection Class: IP00
- Ambient Temperature: -25°C to +60°C
- Installation Height: Up to 5000 meters
- Cable Length: Maximum 500 meters
Performance Characteristics
- The starter provides adjustable current limitation from 86A to 432A.
- It features integrated thermal motor overload protection with PTC evaluation.
- Built-in thyristors ensure reliable power control and smooth operation.
- The device offers 115% continuous operating current capability at 40°C.
- Automatic internal bypass contact reduces power loss during run state.
- Three normally open and one changeover auxiliary contacts enable control.
- LED display provides clear fault indication and status monitoring.
- External reset capability allows for remote system initialization.
Electrical Connections & Installation
- Main circuit connections utilize robust busbar termination system.
- Front terminals accept 70-240mm² fine-stranded cables with ferrules.
- Rear terminals accommodate 120-185mm² cables for flexible wiring.
- Combined clamping points handle up to 2x185mm² parallel conductors.
- Auxiliary circuits use screw terminals for 0.5-2.5mm² conductors.
- Maintain 100mm clearance above unit and 75mm below for ventilation.
- Side clearance of 5mm ensures proper air circulation and heat dissipation.
- Mounting position allows ±90° rotation and ±22.5° forward/backward tilt.
Motor Power Ratings
- Standard circuit delivers 250kW at 400V for three-phase motors.
- Inside-delta configuration provides 400kW at 400V operation.
- At 230V standard circuit, output power reaches 132kW.
- Horsepower ratings range from 125HP to 600HP depending on configuration.
- The starter handles minimum motor loads as low as 8% of rated current.
- Power loss during operation typically measures only 232 watts.
- Derating begins at 40°C ambient temperature for optimal performance.
- Current capacity decreases to 385A at 50°C and 335A at 60°C.
Protection & Safety Features
- Integrated electronic overload protection prevents motor damage.
- Thermal resistor monitoring provides additional motor protection.
- Phase failure detection ensures three-phase operation integrity.
- Current imbalance protection safeguards against uneven loading.
- Short-circuit protection built into the power electronics section.
- Undervoltage and overvoltage protection maintains system stability.
- Earth fault detection available through additional monitoring systems.
- UL/CSA certifications ensure compliance with international standards.
Packaging & Shipping
- Each unit ships in protective packaging with adequate cushioning.
- Package includes one soft starter unit ready for installation.
- We ship worldwide via FedEx, UPS, and DHL express services.
- Tracking information becomes available immediately after dispatch.
- All products include comprehensive 12-month warranty coverage.
- Most orders process within 24 hours of payment confirmation.
Professional Technical FAQ
- What is the difference between standard and inside-delta connection?
- Inside-delta connection allows higher current handling up to 748A for larger motors.
- Can this soft starter operate at high altitude locations?
- Yes, it maintains full performance up to 5000 meters above sea level.
- What type of motor protection does this unit provide?
- It includes electronic overload, thermal monitoring, and phase failure protection.
- How many auxiliary contacts are available for control circuits?
- The unit provides three NO contacts and one changeover contact for signaling.
- What is the recommended derating above 40°C ambient temperature?
- Current capacity reduces to 385A at 50°C and 335A at 60°C for safe operation.