Bently Nevada 3300 XL 8mm Probe | 330103-00-05-15-02-05
UBEST – Αξιόπιστος Παγκόσμιος Προμηθευτής Ανταλλακτικών Αυτοματισμού
Προσφέρουμε μια μεγάλη γκάμα διαθέσιμων ανταλλακτικών βιομηχανικού αυτοματισμού. Όλα τα προϊόντα συνοδεύονται από 12μηνη εγγύηση και 30ήμερη επιστροφή χρημάτων για θέματα ποιότητας.
Bently Nevada 3300 XL 8mm Extended Cable Hazardous Area Probe
Introducing the 330103-00-05-15-02-05, featuring extended reach for challenging installations. This model combines extra cable length with explosion-proof certification. The 330103-00-05-15-02-05 delivers safety and convenience in one package. Perfect for applications where monitoring equipment is located farther from measurement points.
Review extended cable specifications: Download Extended Cable Details
Technical Specifications
- Brand: Bently Nevada
- Product Series: 3300 XL Extended Reach
- Complete Model: 330103-00-05-15-02-05
- Probe Diameter: 8mm industry standard
- Thread Specification: M10 × 1.0 mm fully threaded
- Unthreaded Length: 0mm (completely threaded)
- Case Length: 50mm compact design
- Cable Length: 1.5 meters (4.9 feet) extended
- Measurement Range: 2.0mm (80 mils) linear
- Optimal Gap Setting: 1.27mm (50 mils)
- Voltage Output: -1 to -17 VDC range
- Standard Output: -9 VDC for vibration monitoring
- Electrical Resistance: 7.73 ± 0.50 Ω (1.5m cable)
- Cable Type: Standard coaxial design
- Connector: Miniature ClickLoc
- Housing Material: 303/304 Stainless Steel
- Tip Material: PPS (Polyphenylene Sulfide)
- Sealing System: Viton O-ring protection
- Temperature Range: -52°C to +177°C
- Unit Weight: 323 g/m (11.4 oz/ft)
- Safety Certifications: CSA, ATEX, IECEx
- Hazard Classification: Class I, Zone 0/1/2
- Protection Level: AEx/Ex ia IIC T5-T1
- Maximum System Cable: 305 meters (1000 feet)
- Humidity Resistance: Less than 3% change at 93% RH
Model Number Breakdown
- 330103: 8mm probe with M10×1 thread
- 00: No unthreaded section
- 05: 50mm total case length
- 15: 1.5 meter extended cable
- 02: Standard ClickLoc connector
- 05: CSA, ATEX, IECEx certifications
Application Questions
-
When is extended cable length beneficial?
When monitors are located farther from measurement points in hazardous areas. -
Does cable length affect electrical resistance?
Yes, 1.5m cable has 7.73Ω resistance versus 7.59Ω for 1.0m cable. -
Can this probe monitor equipment in explosive areas?
Yes, when installed with proper intrinsic safety barriers. -
What applications need compact 50mm cases?
Space-constrained hazardous locations requiring extended cable reach. -
How does temperature affect extended cable performance?
Stable operation across full -52°C to +177°C temperature range.
© 2025 Ubest Automation Limited. All rights reserved.
Original Source: https://www.ubestplc.com/
Contact: sales@ubestplc.com Phone: +86 180 3000 5825