{"product_id":"ubest-relay-output-module-non-triplicated-control-3636r","title":"Ubest Relay Output Module | Non-Triplicated Control 3636R","description":"\u003ch2\u003eUbest 3636R Relay Output Module for Non-Critical Control Points\u003c\/h2\u003e\n\u003cp\u003eThe Ubest \u003cstrong\u003eModel 3636R\u003c\/strong\u003e Relay Output Module delivers reliable performance for non-critical automation applications. This non-triplicated module specifically interfaces with devices like annunciator panels that cannot use high-side solid-state switches. It processes output commands from three separate main processor channels. The system performs voting on these three signal sets and uses the final voted data to operate its 32 individual relays.\u003c\/p\u003e\n\u003ch3\u003eCore Technical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e: Ubest Automation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel Number\u003c\/strong\u003e: \u003cstrong\u003e3636R\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType\u003c\/strong\u003e: Non-triplicated module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePoints\u003c\/strong\u003e: 32 non-commoned outputs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Range\u003c\/strong\u003e: Maximum 155 VAC\/VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Load\u003c\/strong\u003e: Maximum 2A per point\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitching Power, Resistive\u003c\/strong\u003e: 2000 VA, 150 watts maximum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePoint Isolation\u003c\/strong\u003e: 1500 VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFuses\u003c\/strong\u003e: One 2.5A fast-acting fuse per output\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDiagnostics and Operational Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEach output includes an independent loopback test circuit\u003c\/li\u003e\n\u003cli\u003eThe circuit verifies each relay's operation without any connected load\u003c\/li\u003e\n\u003cli\u003eContinuous diagnostics constantly monitor the module's health status\u003c\/li\u003e\n\u003cli\u003eAny diagnostic failure immediately activates the FAULT indicator\u003c\/li\u003e\n\u003cli\u003eThe fault indicator also triggers the main chassis alarm system\u003c\/li\u003e\n\u003cli\u003eModule status shows through PASS, FAULT, and ACTIVE indicator lights\u003c\/li\u003e\n\u003cli\u003eAll 32 points feature individual output status indicators\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical Design and Integration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe module features silver blue colored housing for easy identification\u003c\/li\u003e\n\u003cli\u003eIt comes with Normally Open (NO) contact relays as standard configuration\u003c\/li\u003e\n\u003cli\u003eThe \u003cstrong\u003e3636R\u003c\/strong\u003e module fully supports operation with hot-spare modules\u003c\/li\u003e\n\u003cli\u003eIt requires a separate External Termination Panel (ETP) for installation\u003c\/li\u003e\n\u003cli\u003eThe ETP provides the cable interface to the Tricon system backplane\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePackaging and Shipping Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEach package contains one Ubest \u003cstrong\u003eModel 3636R\u003c\/strong\u003e Relay Output Module\u003c\/li\u003e\n\u003cli\u003eWe ship all orders via reliable global carriers including FedEx, UPS, and DHL\u003c\/li\u003e\n\u003cli\u003eYou receive fast and fully trackable delivery service for complete convenience\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the primary application for the 3636R module?\u003c\/strong\u003e It is perfect for non-critical points and annunciator panel interfaces.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDoes this module support hot-swapping functionality?\u003c\/strong\u003e Yes, it fully supports hot-spare modules for maximum system availability.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs external hardware required for installation?\u003c\/strong\u003e Yes, you need a separate External Termination Panel for proper setup.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat relay contact type does this module use?\u003c\/strong\u003e It comes standard with Normally Open (NO) contacts.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e© 2025 Ubest Automation Limited. All rights reserved.\u003cbr\u003eOriginal Source: \u003ca href=\"https:\/\/www.ubestplc.com\/\"\u003ehttps:\/\/www.ubestplc.com\/\u003c\/a\u003e\u003cbr\u003eContact: \u003ca href=\"mailto:sales@ubestplc.com\"\u003esales@ubestplc.com\u003c\/a\u003e Phone: \u003ca href=\"https:\/\/wa.me\/868618030005825\"\u003e+86 86 180 3000 5825\u003c\/a\u003e\u003c\/p\u003e","brand":"More Brands","offers":[{"title":"Default Title","offer_id":51212193923354,"sku":null,"price":169.0,"currency_code":"USD","in_stock":true}],"url":"https:\/\/www.ubestplc.com\/es\/products\/ubest-relay-output-module-non-triplicated-control-3636r","provider":"Ubest Automation Limited","version":"1.0","type":"link"}