{"product_id":"schneider-electric-quantum-dc-output-module-140ddo36400c","title":"Schneider Electric Quantum DC Output Module 140DDO36400C","description":"\u003ch2\u003eSchneider Electric 140DDO36400C DC Output Module\u003c\/h2\u003e\n\u003cp\u003eThe Schneider Electric \u003cstrong\u003e140DDO36400C\u003c\/strong\u003e is a high-density DC output module for the Modicon Quantum platform. This module provides ninety-six discrete output channels organized in six groups. It delivers reliable 24V DC switching for industrial control applications requiring numerous output points.\u003c\/p\u003e\n\u003ch3\u003eCore Technical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Schneider Electric\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cspan style=\"color: #d35400;\"\u003e\u003cstrong\u003e140DDO36400C\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Line:\u003c\/strong\u003e Modicon Quantum Automation Platform\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Type:\u003c\/strong\u003e 96-Channel DC Discrete Output (Sink)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Voltage:\u003c\/strong\u003e \u003cspan style=\"color: #27ae60;\"\u003e24V DC Nominal (19.2 to 30V Range)\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Logic:\u003c\/strong\u003e Negative Logic (Sink)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAddressing:\u003c\/strong\u003e Requires 6 Output Words\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBus Current:\u003c\/strong\u003e 250 mA @ 5V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Dissipation:\u003c\/strong\u003e 7 Watts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNet Weight:\u003c\/strong\u003e 0.45 kg (0.99 lbs)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical Ratings \u0026amp; Performance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannels per Group:\u003c\/strong\u003e 16 Channels (6 Groups Total)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent per Point:\u003c\/strong\u003e ≤ 0.5 A Continuous\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent per Group:\u003c\/strong\u003e ≤ 3.2 A Continuous\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent per Module:\u003c\/strong\u003e ≤ 19.2 A Total\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSurge Current:\u003c\/strong\u003e 2 A per Point\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Drop:\u003c\/strong\u003e \u0026lt; 0.4 V @ 0.5 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLeakage Current:\u003c\/strong\u003e ≤ 1 mA @ 24V (Off State)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse Time:\u003c\/strong\u003e ≤ 0.1 ms (ON and OFF)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation:\u003c\/strong\u003e 500 Vrms (Channel to Bus for 1 minute)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProtection \u0026amp; Diagnostic Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eShort-Circuit Protection:\u003c\/strong\u003e Yes (Built-in)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOverload Protection:\u003c\/strong\u003e Yes (Built-in)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFault Indication:\u003c\/strong\u003e Fault Sensing and Reporting\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoss of Field Power:\u003c\/strong\u003e Detected and Reported\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannel Status:\u003c\/strong\u003e 96 Green LEDs (Output Status)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Status:\u003c\/strong\u003e 1 Green LED (Bus Active), 1 Red LED (External Fault)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInductive Load Formula:\u003c\/strong\u003e L(H) = 0.5 \/ ((I(A))² × f(Hz)) for 0.5-4 Hz switching\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental \u0026amp; Compliance Data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e \u003cspan style=\"color: #27ae60;\"\u003e0 to 60°C (32 to 140°F)\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e -40 to 85°C (-40 to 185°F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Humidity:\u003c\/strong\u003e Up to 95% (non-condensing)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Altitude:\u003c\/strong\u003e Up to 5000 meters (16404 feet)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC Immunity:\u003c\/strong\u003e 10 V\/m (80-2000 MHz per IEC 801-3)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eESD Protection:\u003c\/strong\u003e 4 kV contact, 8 kV air discharge (IEC 801-2)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePCB Protection:\u003c\/strong\u003e Conformal coating (Humiseal 1A33)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertifications:\u003c\/strong\u003e cUL, FM Class 1 Div 2, RMRS, C-Tick, GOST\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandards:\u003c\/strong\u003e UL 508, CSA C22.2 No.142, CE Marked\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePackaging \u0026amp; Shipping Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackage Includes:\u003c\/strong\u003e One Schneider Electric \u003cstrong\u003e140DDO36400C\u003c\/strong\u003e module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShipping:\u003c\/strong\u003e Global delivery via FedEx, UPS, DHL\u003c\/li\u003e\n\u003cli\u003eStandard industrial packaging ensures damage-free transport\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 12-month quality assurance period\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation \u0026amp; Wiring Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the module in an enclosure maintaining the \u003cspan style=\"color: #27ae60;\"\u003e0-60°C ambient range\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eUse proper 24V DC power supply within the 19.2-30V operational window\u003c\/li\u003e\n\u003cli\u003eDo not exceed 0.5A continuous current per output channel\u003c\/li\u003e\n\u003cli\u003eImplement appropriate fusing for each output group based on load requirements\u003c\/li\u003e\n\u003cli\u003eFollow the inductive load formula for switching solenoids or relays above 0.5Hz\u003c\/li\u003e\n\u003cli\u003eEnsure all field wiring uses correct gauge for the 0.5A load current\u003c\/li\u003e\n\u003cli\u003eMaintain separation between DC output wires and analog signal cables\u003c\/li\u003e\n\u003cli\u003eVerify all connections are secure to prevent voltage drop issues\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProfessional Questions \u0026amp; Answers\u003c\/h3\u003e\n\u003ch4\u003eWhat does \"negative logic (sink)\" mean for wiring?\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eThe module switches the negative side (0V) of the load. The load's positive side connects directly to the 24V DC supply, and the module provides the path to ground when activated.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eHow do I calculate heat dissipation for my cabinet?\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eThe module dissipates a fixed 7W plus load-dependent heat. At full load (19.2A), total dissipation is approximately 7W + (19.2A × load voltage drop). Ensure adequate cabinet cooling for continuous operation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eCan I connect inductive loads directly to the outputs?\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eYes, but you must calculate using the provided formula. For example, switching a 0.5A solenoid at 2Hz requires inductance below 0.25H. Always use suppression diodes or varistors for inductive loads.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eWhat happens during a short circuit on one output?\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eThe built-in protection limits the current and the module reports a fault. The specific channel's LED may indicate the issue, and the fault word in the controller can be programmed for system response.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eIs this module suitable for high-speed switching applications?\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eWith a 0.1ms response time, it can handle moderately fast switching. However, for very high frequencies above 4Hz with inductive loads, consult the inductance formula to avoid damage from voltage spikes.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e© 2025 Ubest Automation Limited. All rights reserved.\u003cbr\u003eOriginal Source: \u003ca rel=\"noopener\" href=\"https:\/\/www.ubestplc.com\/\" target=\"_blank\"\u003ehttps:\/\/www.ubestplc.com\/\u003c\/a\u003e\u003cbr\u003eContact: \u003ca href=\"mailto:sales@ubestplc.com\"\u003esales@ubestplc.com\u003c\/a\u003e | Phone: \u003ca rel=\"noopener\" href=\"https:\/\/wa.me\/8618030005825\" target=\"_blank\"\u003e+86 180 3000 5825\u003c\/a\u003e\u003c\/p\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":51456693829914,"sku":"140DDO36400C","price":199.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/140DDO36400C_2be253d5-80f6-4699-9f39-085fd3045f4e.jpg?v=1765779898","url":"https:\/\/www.ubestplc.com\/fa\/products\/schneider-electric-quantum-dc-output-module-140ddo36400c","provider":"Ubest Automation Limited","version":"1.0","type":"link"}