Core Technical Specifications
- Brand & Model: Allen-Bradley 150-F625NBE SMC Flex
- Input Voltage: 200-460V AC, 3-Phase, 50/60 Hz
- Control Voltage: 110/120V AC for 625-1250A units
- Output Current: 625 Amperes continuous rating
- Output Power: 500 HP at 460V AC maximum
- Power Rating: 400/415 kilowatts capacity
- Enclosure Type: Open design (IP00 protection)
Power & Electrical Ratings
- Rated Voltage: 200-460V AC operating range
- Control Power: 110/120V AC at 50-60 Hz
- Current Capacity: 625A output capability
- Horsepower: 500 HP at 460V AC maximum
- Kilowatt Rating: 400/415 kW power handling
- Phase Requirement: Three-phase power supply
Control & Operation Features
- Soft Start: Gradual voltage increase method
- Initial Torque: User adjustable 0-90% setting
- Acceleration Ramp: Configurable ramp timing
- Bypass Contactor: Built-in for efficiency
- Step Control: Voltage increase in stages
- Speed Achievement: Automatic bypass activation
Programming & Interface
- Control Panel: 5-button keypad for programming
- Display: Integrated LCD screen for monitoring
- Navigation: UP and DOWN arrow buttons
- Selection: SEL button enters edit mode
- Confirmation: ENTER button saves parameters
- Exit Function: ESC button cancels or exits
Control Buttons & Functions
- Start Button: Initiates motor starting sequence
- Stop Button: Commands motor stopping
- Jog Button: Temporary motor operation control
- Manual Control: Direct operator intervention
- Operation Mode: Local control capability
- Immediate Access: Quick function activation
Parameter Structure & Levels
- Programming Groups: Organized parameter sets
- Three Levels: Structured access hierarchy
- Timing Parameters: Acceleration and delay settings
- Protection Settings: Safety limit configurations
- Alarm Parameters: Fault condition definitions
- Limit Values: Operational boundary settings
Application Areas
- Hoisting Machines: Large lifting equipment control
- Conveying Systems: Material transport applications
- Pressing Equipment: Industrial press control
- Drilling Machines: Large drilling operations
- Heavy Machinery: High-power industrial equipment
- Large Motors: Big industrial motor control
Physical Specifications
- Weight: 250.00 lbs (113.40 kg) substantial build
- Enclosure: Open type with IP00 rating
- Protection: Requires mechanical protection
- Installation: Indoor use only requirement
- Construction: Heavy-duty industrial design
- Mounting: Secure installation necessary
Efficiency & Performance
- Heat Reduction: Bypass contactor lowers losses
- Energy Efficient: Optimized power usage
- Cooling Management: Reduced heat dissipation
- System Losses: Minimized internal losses
- Motor Protection: Extended equipment life
- Operational Savings: Lower operating costs
Installation Requirements
- Location: Indoor installation only
- Protection: Mechanical protection needed
- Voltage Supply: Proper power source required
- Mounting: Secure industrial mounting
- Ventilation: Adequate cooling necessary
- Environment: Clean, dry location preferred
Operation Principles
- Starting Method: Initial torque application first
- Voltage Steps: Gradual increase to final value
- Ramp Timing: User-defined acceleration period
- Speed Detection: Nominal speed recognition
- Bypass Activation: Automatic line connection
- Motor Connection: Direct line voltage application
Safety & Protection
- Enclosure Rating: IP00 basic protection level
- Installation Safety: Requires protective enclosure
- Electrical Safety: Proper grounding essential
- Operational Safety: Controlled starting sequence
- Equipment Protection: Prevents motor damage
- System Safety: Built-in safety features
Package & Support
- Allen-Bradley 150-F625NBE Controller unit
- Documentation and programming manuals
- Installation and setup guidelines
- Global shipping via FedEx, UPS, and DHL
- Professional technical assistance
- Comprehensive quality warranty
Expert Questions & Answers
- What is the main advantage of the bypass contactor?
The bypass contactor reduces internal heat and losses. It connects the motor directly to line voltage after starting.
- Why does this controller require indoor installation?
The 150-F625NBE has IP00 rating with minimal protection. It needs indoor installation with mechanical protection from environmental elements.
- How does soft start benefit large motors?
Soft start reduces mechanical stress during acceleration. It prevents damage to motors and driven equipment from sudden torque application.
- What types of applications need 625A capacity?
Large hoists, heavy conveyors, industrial presses, and big drilling machines require this high current capacity for reliable operation.
- How are parameters organized for programming?
Parameters are grouped into three access levels. This structure organizes timing, protection, and alarm settings logically.
© 2025 Ubest Automation Limited. All rights reserved.
Original Source: https://www.ubestplc.com/
Contact: sales@ubestplc.com Phone: +86 180 3000 5825