UBEST – Pemasok Suku Cadang Otomasi Global Terpercaya
Kami menawarkan berbagai suku cadang otomasi industri yang tersedia di stok. Semua produk dilengkapi dengan garansi 12 bulan dan pengembalian dana 30 hari untuk masalah kualitas.
Bently Nevada 330190-075-00-CN Armored ETR Cable
Engineered for extreme conditions, this 3300 XL armored extension cable provides maximum durability. The 330190-075-00-CN combines mechanical protection with precise signal transmission for critical monitoring applications.
Product Overview & Key Features
- Manufacturer: Bently Nevada
- Product Series: 3300 XL Vibration Monitoring System
- Model Number: 330190-075-00-CN
- Cable Type: Armored Extended Temperature Range (ETR)
- Construction: 75Ω Triaxial with PFA Insulation
- Armor Material: Corrugated stainless steel for crush protection
- Jacket Material: Polyurethane for abrasion resistance
- Country Approval: CN specific certification included
Electrical Performance Specifications
- Center Conductor Resistance: 1.65 Ω ± 0.25 at 20°C
- Outer Shield Resistance: 0.49 Ω ± 0.10 at 20°C
- Capacitance Core-to-Shield: 69.9 pF/m typical
- Characteristic Impedance: 75Ω ±5% from 1-100 MHz
- Dielectric Withstanding Voltage: 1500 Vrms for 60 seconds
- Insulation Resistance: ≥5000 MΩ per kilometer at 500 VDC
- Signal Bandwidth: DC to 15 kHz (-3 dB point)
Mechanical & Physical Properties
- Cable Length: 7.5 meters (24.6 feet) exact length
- Cable Outer Diameter: 6.2 mm with armor protection
- Minimum Bend Radius: 50 mm (2.0 inches) under tension
- Cable Weight: 103 g/m (1.5 oz/ft) armored version
- Connector Type: Gold-plated triaxial 8mm design
- Mating Cycles: ≥500 cycles without performance degradation
- Crush Resistance: Withstands 2000 N/cm crushing force
Environmental & Operating Conditions
- Temperature Range: -52°C to +260°C continuous operation
- Thermal Cycling: 1000 cycles from -55°C to +260°C
- Humidity Resistance: 95% RH at 65°C for 1000 hours
- Oil Resistance: Compatible with lubricating oils and fuels
- Chemical Resistance: Resists acids, alkalis, and solvents
- Flame Rating: IEC 60332-1-2 flame retardant certified
- UV Resistance: Suitable for outdoor installation
Measurement System Performance
- Linear Range: 0.25 mm to 2.3 mm from target surface
- Recommended Gap: 1.27 mm (50 mils) for -9 VDC output
- System Sensitivity: 7.87 V/mm (200 mV/mil) standard
- Nonlinearity: <±1% over entire linear range
- Temperature Coefficient: ±0.05%/°C over operating range
- Hysteresis: <0.5% of full scale output
- Resolution: Better than 0.1 μm (4 μinches)
Installation Requirements
- Field Wiring: 0.2 to 1.5 mm² (16-24 AWG) shielded triad
- Maximum Distance: 305 meters between sensor and monitor
- Wiring Preparation: Use tinned copper conductors only
- Shielding: Continuous 360° shield termination required
- Grounding: Single-point ground at monitor location
- Separation: Keep 300 mm from power cables
- Strain Relief: Provide within 150 mm of connector
Compliance & Safety Information
- Functional Safety: SIL 2 (HFT=0) and SIL 3 (HFT=1) capable
- EMC Immunity: EN 61000-6-2 for industrial environments
- EMC Emissions: EN 61000-6-4 Class A requirements
- Maritime Approval: ABS, DNV, LR, and BV certified
- RoHS Compliance: 2011/65/EU without exemptions
- Vibration Test: IEC 60068-2-6, 10g, 10-2000 Hz
- Shock Test: IEC 60068-2-27, 50g, 11 ms duration
Shipping & Delivery Information
- Packaging: Individual protective tube with end caps
- Documentation: Includes test certificate and data sheet
- Shipping Methods: FedEx, UPS, DHL express available
- Lead Time: Standard stock to 4 weeks for reliability
- Order Verification: Includes serialized test records
Technical Support FAQ
- What advantage does armored cable provide over standard?
- Armored construction adds crush protection and durability in harsh plants.
- Can this cable withstand direct burial applications?
- No, the armored version needs conduit for direct burial installation.
- What maintenance does this extension cable require?
- Regular inspection for physical damage and connector integrity checks.
- How does temperature affect cable resistance values?
- Resistance increases approximately 0.4% per °C temperature rise.
- What tools are needed for proper connector installation?
- Use torque wrench and proper triaxial connector tool kit only.