{"product_id":"ge-is420ucsch1b-controller-mark-vies-quad-core-safety-system","title":"GE IS420UCSCH1B Controller | Mark VIeS Quad-Core Safety System","description":"\u003ch2\u003eAdvanced Quad-Core Safety Controller for Critical Applications\u003c\/h2\u003e\n\u003cp\u003eThe GE Vernova \u003cstrong\u003eIS420UCSCH1B\u003c\/strong\u003e delivers high-performance control for safety-critical systems. This UCSC gateway controller operates within the Mark VIeS functional safety platform. It features quad-core processing and comprehensive networking capabilities. The unit ensures reliable operation in demanding industrial environments.\u003c\/p\u003e\n\u003ch3\u003eProduct Identification \u0026amp; Overview\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e GE Vernova\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong\u003eIS420UCSCH1B\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem:\u003c\/strong\u003e Mark VIeS Functional Safety\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eController Type:\u003c\/strong\u003e UCSC Stand-Alone Gateway\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCore Technical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcessor:\u003c\/strong\u003e \u003cmark\u003e1.2 GHz AMD G-Series quad-core\u003c\/mark\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMemory:\u003c\/strong\u003e \u003cmark\u003e4 GB DDR3-1333 ECC SDRAM\u003c\/mark\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating System:\u003c\/strong\u003e QNX Neutrino RTOS 6.5\/7.1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEthernet Ports:\u003c\/strong\u003e 6 total (5 front, 1 bottom)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIONet Ports:\u003c\/strong\u003e 3 for I\/O communications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e -40 to 85°C range\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Altitude:\u003c\/strong\u003e 0-1000 meters maximum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply:\u003c\/strong\u003e 18-32 VDC input range\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 8.03\" x 5.99\" x 2.17\"\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 1,327 grams complete unit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCooling Method:\u003c\/strong\u003e Convection cooling system\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e DIN-rail installation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRedundancy:\u003c\/strong\u003e Simplex, Dual, TMR supported\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHMI Interface:\u003c\/strong\u003e ControlST V07.00.00C+\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAdvanced Feature Set\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVirtualization:\u003c\/strong\u003e Real-time hypervisor technology\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCloud Connectivity:\u003c\/strong\u003e Predix EFA integration\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNetwork Protocols:\u003c\/strong\u003e Modbus TCP, OPC UA, EGD\/UDH\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Certification:\u003c\/strong\u003e Functional safety compliant\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eData Storage:\u003c\/strong\u003e 3067 NVSRAM program variables\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotalizers:\u003c\/strong\u003e 64 counting registers available\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eForce Points:\u003c\/strong\u003e 338 configurable force points\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiagnostics:\u003c\/strong\u003e Comprehensive hardware monitoring\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation:\u003c\/strong\u003e Signal separation and protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Requirements\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount on standard DIN-rail in control cabinet\u003c\/li\u003e\n\u003cli\u003eMaintain ambient temperature 0-55°C operational\u003c\/li\u003e\n\u003cli\u003eEnsure adequate convection cooling space\u003c\/li\u003e\n\u003cli\u003eFollow cable separation guidelines precisely\u003c\/li\u003e\n\u003cli\u003eVerify power supply within 18-32 VDC range\u003c\/li\u003e\n\u003cli\u003eConnect Ethernet ports per network design\u003c\/li\u003e\n\u003cli\u003eConfigure redundancy settings as required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePackage Contents\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOne GE \u003cstrong\u003eIS420UCSCH1B\u003c\/strong\u003e controller unit\u003c\/li\u003e\n\u003cli\u003eInstallation and configuration guide\u003c\/li\u003e\n\u003cli\u003eDIN-rail mounting hardware set\u003c\/li\u003e\n\u003cli\u003eDocumentation and specification sheets\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWarranty \u0026amp; Support\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e12-month comprehensive product warranty\u003c\/li\u003e\n\u003cli\u003eTechnical support for installation\u003c\/li\u003e\n\u003cli\u003ePerformance guarantee under specifications\u003c\/li\u003e\n\u003cli\u003eQuality assurance commitment\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eShipping Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFedEx international priority service\u003c\/li\u003e\n\u003cli\u003eUPS worldwide express delivery\u003c\/li\u003e\n\u003cli\u003eDHL global freight options\u003c\/li\u003e\n\u003cli\u003eComplete tracking capability\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Questions \u0026amp; Answers\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eWhat is the difference between UCSC and traditional controllers?\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eUCSC controllers operate without backplane I\/O hosting, using distributed I\/O over IONet instead of local I\/O modules.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eHow does the virtual network feature work?\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eThe hypervisor creates virtual networks between VMs, enabling secure data exchange between Mark VIe control and EFA components.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eWhat redundancy configurations are supported?\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eThe controller supports simplex, dual, and TMR (Triple Modular Redundancy) configurations for different safety requirements.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eWhat is the purpose of the Embedded Field Agent?\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eEFA enables Predix cloud connectivity and web applications while maintaining separation from critical control functions.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eHow are the Ethernet ports allocated for different functions?\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eThree IONet ports handle I\/O communications, ENET1\/2 manage network data, and a dedicated port provides cloud connectivity.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e© 2025 Ubest Automation Limited. All rights reserved.\u003cbr\u003eOriginal Source: \u003ca href=\"https:\/\/www.ubestplc.com\/\"\u003ehttps:\/\/www.ubestplc.com\/\u003c\/a\u003e\u003cbr\u003eContact: \u003ca href=\"mailto:sales@ubestplc.com\"\u003esales@ubestplc.com\u003c\/a\u003e Phone: \u003ca href=\"https:\/\/wa.me\/8686180030005825\"\u003e+86 86 180 3000 5825\u003c\/a\u003e\u003c\/p\u003e","brand":"GE","offers":[{"title":"Default Title","offer_id":51223120511258,"sku":null,"price":173.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/IS420UCSCH1B_3.jpg?v=1760925906","url":"https:\/\/www.ubestplc.com\/id\/products\/ge-is420ucsch1b-controller-mark-vies-quad-core-safety-system","provider":"Ubest Automation Limited","version":"1.0","type":"link"}