{"product_id":"389-01-12-55-rosemount-ph-orp-sensor-general-purpose-emerson","title":"389-01-12-55 Sensore pH\/ORP Rosemount Uso Generale Emerson","description":"\u003ch2\u003e\u003cstrong\u003eRosemount™ 389-01-12-55: Sensore pH\/ORP per Uso Generale in Ambienti Difficili\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMarca e Modello:\u003c\/strong\u003e Rosemount™ \u003cstrong\u003e389-01-12-55\u003c\/strong\u003e – un sensore pH\/ORP per uso generale.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntervalli di Misura:\u003c\/strong\u003e \u003cspan style=\"color: #e03e2e;\"\u003epH da 0 a 14\u003c\/span\u003e e \u003cspan style=\"color: #e03e2e;\"\u003eORP da -1500 a +1500 mV\u003c\/span\u003e coprono la maggior parte dei fluidi industriali.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntervallo di Temperatura:\u003c\/strong\u003e Funziona da 0 a 85 °C (32 a 185 °F) per un uso versatile.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompensazione Automatica della Temperatura:\u003c\/strong\u003e Attiva da 0 a 85 °C (32 a 185 °F).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRiferimento a Tripla Giunzione:\u003c\/strong\u003e Resiste agli ioni tossici come ammoniaca, cloro e solfuri.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVetro Resistente alla Rottura:\u003c\/strong\u003e Estende la durata del sensore in ambienti chimici aggressivi.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMateriale dell’Elettrodo ORP:\u003c\/strong\u003e Il platino garantisce misurazioni stabili di ossido-riduzione.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTipo di Giunzione:\u003c\/strong\u003e Giunzione in ceramica assicura un potenziale di riferimento costante.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMateriale degli O-Ring:\u003c\/strong\u003e Gli O-ring in Viton® offrono una resistenza chimica superiore.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMateriali a Contatto con il Processo:\u003c\/strong\u003e Corpo e dado in poliestere\/policarbonato; raccordi in acciaio inox 316.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnessioni di Processo:\u003c\/strong\u003e \u003cspan style=\"color: #e03e2e;\"\u003e1 pollice MNPT frontale e posteriore\u003c\/span\u003e per un montaggio flessibile.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFilettatura del Sensore:\u003c\/strong\u003e Adattatore 1 pollice NPT per un’integrazione semplice.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallazione Facile – Rosemount™ 389-01-12-55\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUsa le filettature sagomate 1 pollice MNPT per inserimento, immersione o configurazioni a flusso.\u003c\/li\u003e\n\u003cli\u003eSeleziona l’opzione cavo Variopol (VP8) (Rosemount™ 389VP) per un rapido sgancio del cavo.\u003c\/li\u003e\n\u003cli\u003eQuesta connessione del cavo elimina torsioni durante la rimozione o l’installazione del sensore.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eManutenzione Intelligente e Compatibilità con Trasmettitori\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eI trasmettitori Rosemount riconoscono automaticamente il sensore pH \u003cstrong\u003e389-01-12-55\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eTrasmettitori compatibili: \u003cspan style=\"color: #e03e2e;\"\u003e56, 1056, 1057 e 1066\u003c\/span\u003e con preamplificatore SMART integrato.\u003c\/li\u003e\n\u003cli\u003eIl sensore memorizza i dati di calibrazione pH per una vera installazione “plug and play” in campo.\u003c\/li\u003e\n\u003cli\u003ePuoi calibrare i sensori in anticipo per risparmiare tempo in loco.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ – Sensore Rosemount™ 389-01-12-55\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eD: Questo sensore può gestire applicazioni ad alto pH?\u003c\/strong\u003e R: Sì, scegli l’elettrodo in vetro opzionale per pH elevati.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eD: Il \u003cstrong\u003e389-01-12-55\u003c\/strong\u003e funziona con trasmettitori non Rosemount?\u003c\/strong\u003e R: Funziona meglio con Rosemount 56, 1056, 1057, 1066 e 5081.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eD: Il cavo è sostituibile senza attrezzi?\u003c\/strong\u003e R: L’opzione VP8 consente lo sgancio del cavo senza attrezzi.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eD: Qual è la pressione massima per l’immersione?\u003c\/strong\u003e R: Seguire le specifiche della cella di flusso: massimo 90 psig.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAutore: Ubest Automation – il tuo partner per sensori di processo di precisione.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e© 2026 Ubest Automation Limited. \u003ca href=\"https:\/\/www.ubestplc.com\/\"\u003ehttps:\/\/www.ubestplc.com\/\u003c\/a\u003e Tutti i diritti riservati.\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eContatti: \u003ca href=\"mailto:sales@ubestplc.com\"\u003esales@ubestplc.com\u003c\/a\u003e | Telefono: \u003ca href=\"https:\/\/wa.me\/8618030005825\"\u003e+86 180 3000 5825\u003c\/a\u003e (Clicca per chattare su WhatsApp)\u003c\/strong\u003e\u003c\/p\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":52073789128986,"sku":"389-01-12-55","price":215.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/389-01-12-55-1.jpg?v=1776049582","url":"https:\/\/www.ubestplc.com\/it\/products\/389-01-12-55-rosemount-ph-orp-sensor-general-purpose-emerson","provider":"Ubest Automation Limited","version":"1.0","type":"link"}