{"product_id":"allen-bradley-1756-of6ci-controllogix-6-pt-isolated-module","title":"Allen Bradley 1756-OF6CI | Modulo isolato ControlLogix da 6 punti","description":"\u003cp\u003e\u003cstrong\u003ePanoramica del Modulo ControlLogix 1756-OF6CI\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eIl ControlLogix 1756-OF6CI è un modulo ad alte prestazioni con 6 uscite analogiche isolate, progettato per l'uscita di corrente di precisione nei sistemi di automazione industriale. Questo modulo fornisce una conversione e trasmissione del segnale accurata e affidabile all'interno dei sistemi ControlLogix.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSpecifiche Elettriche\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntervallo\u003c\/strong\u003e: 0mA - 21mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumero di Bit Significativi\u003c\/strong\u003e: 13 bit\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRisoluzione\u003c\/strong\u003e: 2,7μA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntervallo Disponibile\u003c\/strong\u003e: 0mA - 20mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSegnale Basso e Conteggi Utente\u003c\/strong\u003e: 0mA \/ -32768 conteggi\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSegnale Alto e Conteggi Utente\u003c\/strong\u003e: 21,074mA \/ 32767 conteggi\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntervalli Strumentali Consigliati\u003c\/strong\u003e: Multimetro digitale con risoluzione migliore di 1,0μA\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eSpecifiche di Uscita\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumero di Uscite\u003c\/strong\u003e: 6 canali isolati individualmente\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntervallo di Corrente in Uscita\u003c\/strong\u003e: 0 a 21mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRisoluzione della Corrente\u003c\/strong\u003e: 13 bit su 21mA (2,7μA)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFormato Dati\u003c\/strong\u003e: Giustificato a sinistra, complemento a 2 – modalità intera; IEEE 32 bit – modalità floating point\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtezione da Sovratensione in Uscita\u003c\/strong\u003e: massimo 24V ac\/dc\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtezione da Cortocircuito in Uscita\u003c\/strong\u003e: Corrente limitata elettronicamente a 21mA o meno\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTempo di Assestamento in Uscita\u003c\/strong\u003e: \u0026lt;2ms al 95% del valore finale con carichi resistivi\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrecisione Calibrata\u003c\/strong\u003e: migliore dello 0,1% dell’intervallo da 4mA a 21mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntervallo di Calibrazione\u003c\/strong\u003e: 12 mesi\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDeriva dell’Offset in Uscita con la Temperatura\u003c\/strong\u003e: 1 μA\/°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDeriva del Guadagno con la Temperatura\u003c\/strong\u003e: Tipica: 60 ppm\/°C, Peggiore caso: 100 ppm\/°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eErrore del Modulo su Intero Intervallo di Temperatura\u003c\/strong\u003e: 0,6% dell’intervallo\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTempo Minimo di Scansione del Modulo per Tutti i Canali\u003c\/strong\u003e: 25ms minimo (modalità floating point), 10ms minimo (modalità intera)\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eSpecifiche Meccaniche\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePosizione del Modulo\u003c\/strong\u003e: Chassis ControlLogix 1756\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCorrente del Backplane\u003c\/strong\u003e:\n\u003cul\u003e\n\u003cli\u003e0-550 carichi: 250mA @ 5,1V dc e 225mA @ 24V dc (carico terminato su OUT e RTN)\u003c\/li\u003e\n\u003cli\u003e551-1000 carichi: 250mA @ 5,1V dc e 300mA @ 24V dc (carico terminato su OUT e ALT)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePotenza del Backplane\u003c\/strong\u003e:\n\u003cul\u003e\n\u003cli\u003e0-550 carichi: 6,7W\u003c\/li\u003e\n\u003cli\u003e551-1000 carichi: 8,5W\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDispersione di Potenza nel Modulo\u003c\/strong\u003e:\n\u003cul\u003e\n\u003cli\u003e0-550 carichi: 5,5W\u003c\/li\u003e\n\u003cli\u003e551-1000 carichi: 6,1W\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDispersione Termica\u003c\/strong\u003e:\n\u003cul\u003e\n\u003cli\u003e0-550 carichi: 18,76 BTU\/ora\u003c\/li\u003e\n\u003cli\u003e551-1000 carichi: 20,80 BTU\/ora\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCarico Induttivo\u003c\/strong\u003e: \u0026lt;1 mH\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCoppia di Serraggio Viti RTB\u003c\/strong\u003e: 7-9 inch-pounds (0,8-1Nm)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChiave RTB\u003c\/strong\u003e: Definita dall’utente\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRTB e Alloggiamento\u003c\/strong\u003e: RTB a 20 posizioni (1756-TBNH o TBSH)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConduttori\u003c\/strong\u003e:\n\u003cul\u003e\n\u003cli\u003eDimensione filo: #22 a #14 AWG (0,324 a 2,08 mm²) intrecciato\u003c\/li\u003e\n\u003cli\u003eIsolamento: massimo 3\/64 pollici (1,2mm)\u003c\/li\u003e\n\u003cli\u003eCategoria: 2(3), (4)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eSpecifiche Ambientali\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTensione di Isolamento\u003c\/strong\u003e:\n\u003cul\u003e\n\u003cli\u003eCanale a canale: Optoisolato, isolato tramite trasformatore\u003c\/li\u003e\n\u003cli\u003eUtente a sistema: testato al 100% a 1700V dc per 1s, basato su 250V ac\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResistenza alle Vibrazioni\u003c\/strong\u003e: IEC60068-2-6 (Test Fc, Operativo): 2g @ 10-500Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShock Operativo\u003c\/strong\u003e: IEC60068-2-27 (Test Ea, shock senza imballo): 30g\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShock Non Operativo\u003c\/strong\u003e: IEC60068-2-27 (Test Ea, shock senza imballo): 50g\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEmissioni\u003c\/strong\u003e: CISPR 11: Gruppo 1, Classe A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eImmunità ESD\u003c\/strong\u003e: IEC 61000-4-2: scariche a contatto 6kV, scariche ad aria 8kV\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":49183321194778,"sku":"1756-OF6CI","price":27.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/1756-OF6CI_1.jpg?v=1718519597","url":"https:\/\/www.ubestplc.com\/it\/products\/allen-bradley-1756-of6ci-controllogix-6-pt-isolated-module","provider":"Ubest Automation Limited","version":"1.0","type":"link"}