{"product_id":"allen-bradley-drive-powerflex-753-20f11nd096aa0nnnnn","title":"Allen Bradley Drive | PowerFlex 753 20F11ND096AA0NNNNN","description":"\u003ch2\u003eAllen Bradley PowerFlex 753 AC Drive 20F11ND096AA0NNNNN\u003c\/h2\u003e\n\u003cp\u003eThe Allen Bradley \u003cstrong\u003e20F11ND096AA0NNNNN\u003c\/strong\u003e is a versatile adjustable frequency AC drive from the PowerFlex 753 series. This model provides robust motor control for industrial applications up to 75 horsepower. It features embedded I\/O, an internal dynamic brake transistor, and built-in EMC filtering. The \u003cstrong\u003e20F11ND096AA0NNNNN\u003c\/strong\u003e offers flexible connectivity with an optional communication slot for network integration.\u003c\/p\u003e\n\u003ch3\u003eDrive Identification \u0026amp; Power Ratings\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #d35400;\"\u003e\u003cstrong\u003eBrand:\u003c\/strong\u003e Allen Bradley (Rockwell Automation)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #d35400;\"\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e 20F11ND096AA0NNNNN\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e PowerFlex 753 AC Drive\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Power:\u003c\/strong\u003e Three-Phase, 480 V AC (50\/60 Hz) or 650 V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Power (Normal Duty):\u003c\/strong\u003e 55 kW \/ 75 HP\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Power (Heavy Duty):\u003c\/strong\u003e 45 kW \/ 60 HP\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Current (ND):\u003c\/strong\u003e 96 Amps\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Current (HD):\u003c\/strong\u003e 77 Amps\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Frequency Range:\u003c\/strong\u003e 0 to 590 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl Method:\u003c\/strong\u003e Sensorless Vector Control, Volts\/Hertz (V\/Hz)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eKey Features \u0026amp; Internal Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEmbedded I\/O:\u003c\/strong\u003e Includes digital and analog inputs\/outputs for basic control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDynamic Braking:\u003c\/strong\u003e Integrated DB Transistor for fast motor stopping.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEMC Compliance:\u003c\/strong\u003e Built-in RFI filter for conducted emissions per IEC 61800-3.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommon Mode Jumper:\u003c\/strong\u003e Removed in this configuration for specific installation requirements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCooling Method:\u003c\/strong\u003e Internal Fan, Air Cooled\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication:\u003c\/strong\u003e Optional slot for add-on communication adapters (e.g., EtherNet\/IP, DeviceNet).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHuman Interface Module (HIM):\u003c\/strong\u003e Not included (blanking plate installed).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical \u0026amp; Environmental Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure Type:\u003c\/strong\u003e Open Type (Chassis)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Style:\u003c\/strong\u003e Panel Mount\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrame Size:\u003c\/strong\u003e Frame 5\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIngress Protection (IP):\u003c\/strong\u003e IP20 (front)\/IP00 (chassis) for indoor cabinet use.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e 0°C to 50°C (32°F to 122°F) with derating above 40°C.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e -40°C to 85°C (-40°F to 185°F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRelative Humidity:\u003c\/strong\u003e 5% to 95% (non-condensing)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Altitude:\u003c\/strong\u003e 0-1000 meters without derating; derate 1% per 100m above 1000m.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVibration Resistance:\u003c\/strong\u003e 1.0 G from 2 to 200 Hz per IEC 60068-2-6.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnit Weight:\u003c\/strong\u003e 38.56 kg (85.00 lbs)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical Performance \u0026amp; Protection\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOverload Capacity:\u003c\/strong\u003e 150% of rated current for 60 seconds (Heavy Duty rating).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStarting Torque:\u003c\/strong\u003e Up to 200% of motor rated torque in sensorless vector mode.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpeed Regulation:\u003c\/strong\u003e ±0.5% of base speed (sensorless vector).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEfficiency:\u003c\/strong\u003e Typically \u0026gt; 97.5%.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtections:\u003c\/strong\u003e Motor overload, overcurrent, overvoltage, undervoltage, ground fault, short circuit, heat sink overtemperature.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDC Bus Connections:\u003c\/strong\u003e Terminals provided for connecting a DC power source or bus.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation \u0026amp; Mounting Requirements\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the drive vertically on a solid, flat panel within an enclosed electrical cabinet.\u003c\/li\u003e\n\u003cli\u003eMaintain the specified clearance around the drive (top, bottom, sides) for proper airflow.\u003c\/li\u003e\n\u003cli\u003eUse copper conductors only for all power and control wiring.\u003c\/li\u003e\n\u003cli\u003eConnect the motor leads (U, V, W) directly to the drive's output terminals.\u003c\/li\u003e\n\u003cli\u003eInstall an appropriately rated disconnect switch and fuses or circuit breaker upstream.\u003c\/li\u003e\n\u003cli\u003eGround the drive chassis securely using the designated PE (Protective Earth) terminal.\u003c\/li\u003e\n\u003cli\u003eFor EMC compliance, use shielded motor cable and ground the shield at the drive end.\u003c\/li\u003e\n\u003cli\u003eConfigure motor nameplate data and application parameters via a connected HIM or software.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePackaging \u0026amp; Shipping Details\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackage Contents:\u003c\/strong\u003e 1 x Allen Bradley 20F11ND096AA0NNNNN Drive Unit (Open Chassis)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDocumentation:\u003c\/strong\u003e Quick Start guide may be included; full manual available online.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShipping Weight:\u003c\/strong\u003e Approximately 40 kg (88 lbs) including packaging material.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShipping Methods:\u003c\/strong\u003e Available for shipping via FedEx, UPS, or DHL freight services.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHandling:\u003c\/strong\u003e Use appropriate lifting equipment due to the unit's significant weight.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWarranty Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCoverage Period:\u003c\/strong\u003e 12 months from the original purchase date.\u003c\/li\u003e\n\u003cli\u003eThe warranty covers failures resulting from defects in materials or component workmanship.\u003c\/li\u003e\n\u003cli\u003eProper installation within the published environmental and electrical limits is required.\u003c\/li\u003e\n\u003cli\u003eTechnical support is available to assist with setup and troubleshooting procedures.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eWhat does \"Normal Duty\" vs. \"Heavy Duty\" mean for this drive?\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eNormal Duty (ND) ratings are for typical variable torque loads like fans and pumps, allowing higher horsepower. Heavy Duty (HD) ratings are for constant torque, high-cycling applications like conveyors, which require more thermal capacity at a lower horsepower.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eWhy is the Common Mode Jumper removed on this model?\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eRemoving the CM jumper is a specific configuration for installations where you are using an external RFI filter or have special grounding requirements to meet stringent EMC standards. It helps manage common-mode noise currents in the system.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eCan I run a 480V motor directly on 400V supply with this drive?\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eNo, the input voltage must match the drive's rating. This 480V AC drive requires a 480V (+10%\/-10%) supply. Running it on 400V will cause an undervoltage fault. You must select a drive model rated for your specific supply voltage.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eHow do I program the drive without the Human Interface Module (HIM)?\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eYou can use Rockwell's Connected Components Workbench (CCW) software free of charge. Connect a computer to the drive's embedded serial port (DSI) using a 1203-USB or similar communication cable to configure all parameters.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eIs the internal DB transistor sufficient for my high-inertia stopping application?\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe internal transistor can handle moderate braking energy. For high inertia or rapid cycle braking, you must connect an external braking resistor to the drive's DB terminals. The drive will calculate and display braking resistor requirements during setup.\u003c\/p\u003e\n\u003cp\u003e© 2025 Ubest Automation Limited. All rights reserved.\u003cbr\u003eOriginal Source: \u003ca href=\"https:\/\/www.ubestplc.com\/\"\u003ehttps:\/\/www.ubestplc.com\/\u003c\/a\u003e\u003cbr\u003eContact: \u003ca href=\"mailto:sales@ubestplc.com\"\u003esales@ubestplc.com\u003c\/a\u003e Phone: \u003ca href=\"https:\/\/wa.me\/8618030005825\"\u003e+86 180 3000 5825\u003c\/a\u003e\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":51473798037786,"sku":"20F11ND096AA0NNNNN","price":186.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/20F11ND096AA0NNNNN_3.jpg?v=1766106694","url":"https:\/\/www.ubestplc.com\/it\/products\/allen-bradley-drive-powerflex-753-20f11nd096aa0nnnnn","provider":"Ubest Automation Limited","version":"1.0","type":"link"}