{"product_id":"ic200mdd846-ge-fanuc-mixed-i-o-module-versamax-16-points","title":"IC200MDD846 GE Fanuc Mixed I\/O Module | Versamax 16 Points","description":"\u003ch2\u003e\u003cstrong\u003eGE Fanuc IC200MDD846 Mixed I\/O Module\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eSimplify your system with the \u003cstrong\u003eIC200MDD846\u003c\/strong\u003e I\/O module. This Versamax series component combines inputs and outputs. It features 16 total points. Relay outputs handle high loads. Easy to install. Perfect for various control applications.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Benefits\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMixed I\/O\u003c\/strong\u003e: \u003cspan style=\"color: #e74c3c;\"\u003e8 inputs and 8 outputs\u003c\/span\u003e in one module.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Current\u003c\/strong\u003e: Relay outputs handle up to 2 Amps.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMultiple Voltages\u003c\/strong\u003e: Works with AC and DC voltages.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVisual Status\u003c\/strong\u003e: LED indicators for all points.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolated Outputs\u003c\/strong\u003e: Each output is fully isolated.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVersamax\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIC200MDD846\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMixed I\/O Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTotal Points\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan style=\"color: #e74c3c;\"\u003e16 points\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Points\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 (24V DC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Points\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 (Relay)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2A per point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120\/240V AC, 5\/24\/125V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage Drop\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.3V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e300mA max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation Guide\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eInstall in IC200CHSxxx carrier base. Connect field wiring. Ensure proper voltage levels. Check LED status indicators. Use with CPU or NIU.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eWorks with Versamax systems. Requires compatible carrier base.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eFull \u003cstrong\u003e\u003cspan style=\"color: #e74c3c;\"\u003e12-month warranty\u003c\/span\u003e\u003c\/strong\u003e included.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eShipping\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eFast worldwide shipping via FedEx, UPS, and DHL.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow many points does this module have?\u003c\/strong\u003e\u003cbr\u003eIt has 16 total points - 8 inputs and 8 relay outputs.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat current can the outputs handle?\u003c\/strong\u003e\u003cbr\u003eEach relay output can handle up to 2 Amps.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat voltages are supported?\u003c\/strong\u003e\u003cbr\u003eOutputs support 120\/240V AC and 5\/24\/125V DC.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAre the outputs isolated?\u003c\/strong\u003e\u003cbr\u003eYes, each output is fully isolated for safety.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat carrier is needed?\u003c\/strong\u003e\u003cbr\u003eIt requires an IC200CHSxxx series carrier base.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e© 2025 Ubest Automation Limited. All rights reserved.\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eOriginal Source:\u003c\/strong\u003e \u003ca href=\"https:\/\/www.ubestplc.com\/\"\u003ehttps:\/\/www.ubestplc.com\/\u003c\/a\u003e\u003cbr\u003e\u003cstrong\u003eContact:\u003c\/strong\u003e \u003ca href=\"mailto:sales@ubestplc.com\"\u003esales@ubestplc.com\u003c\/a\u003e | \u003ca href=\"https:\/\/wa.me\/861830005825\"\u003e+86 180 3000 5825\u003c\/a\u003e\u003c\/p\u003e","brand":"GE","offers":[{"title":"Default Title","offer_id":51103403180314,"sku":"IC200MDD846","price":163.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/IC200MDD840-1.jpg?v=1722579920","url":"https:\/\/www.ubestplc.com\/kk\/products\/ic200mdd846-ge-fanuc-mixed-i-o-module-versamax-16-points","provider":"Ubest Automation Limited","version":"1.0","type":"link"}