{"product_id":"schneider-electric-dc-output-module-32-point-140dvo85300","title":"Schneider Electric DC Output Module | 32-Point 140DVO85300","description":"\u003ch2\u003eSchneider Electric 140DVO85300 High-Density DC Output Module\u003c\/h2\u003e\n\u003ch3\u003ePremium Output Performance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Schneider Electric\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong\u003e140DVO85300\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Configuration:\u003c\/strong\u003e 32-point sinking DC output module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Range:\u003c\/strong\u003e 10-30V DC operational capability\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Capacity:\u003c\/strong\u003e 0.5A per point, 16A total module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse Speed:\u003c\/strong\u003e 1-2 ms switching in both directions\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannel Organization:\u003c\/strong\u003e 4 protected groups of 8 outputs\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e8b57;\"\u003eSurge Handling:\u003c\/span\u003e 2.5A for 1ms transient capability\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e8b57;\"\u003eVoltage Drop:\u003c\/span\u003e Less than 0.4V at maximum current\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e8b57;\"\u003ePower Dissipation:\u003c\/span\u003e 2.5W + additional load-based calculation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eComprehensive Protection Systems\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIndividual short-circuit protection on all 32 outputs\u003c\/li\u003e\n\u003cli\u003eGroup-level 5A fuse protection for enhanced safety\u003c\/li\u003e\n\u003cli\u003eOutput overvoltage protection up to 50V for 1 second\u003c\/li\u003e\n\u003cli\u003eBuilt-in thermal monitoring and shutdown features\u003c\/li\u003e\n\u003cli\u003eElectrostatic discharge immunity: 4kV contact, 8kV air\u003c\/li\u003e\n\u003cli\u003eEMC resistance: 10V\/m electromagnetic field immunity\u003c\/li\u003e\n\u003cli\u003eReverse polarity protection on field power inputs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e8b57;\"\u003eOperating Range:\u003c\/span\u003e 32°F to 140°F (0°C to 60°C)\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e8b57;\"\u003eStorage Range:\u003c\/span\u003e -40°F to 185°F (-40°C to 85°C)\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e8b57;\"\u003eHumidity Rating:\u003c\/span\u003e 95% maximum non-condensing\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e8b57;\"\u003eAltitude Performance:\u003c\/span\u003e 16,404 feet (5,000 meters) maximum\u003c\/li\u003e\n\u003cli\u003eVibration resistance: 5-500 Hz, 3g amplitude capability\u003c\/li\u003e\n\u003cli\u003eShock tolerance: 35g for 11ms mechanical stress\u003c\/li\u003e\n\u003cli\u003eMultiple international certifications including GOST, FM, C-tick\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAdvanced Diagnostic Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e32 individual green LEDs for output status monitoring\u003c\/li\u003e\n\u003cli\u003eDual-color LED for communication and fault indication\u003c\/li\u003e\n\u003cli\u003eComprehensive fault detection for incorrect output states\u003c\/li\u003e\n\u003cli\u003eField power loss monitoring and blown fuse indication\u003c\/li\u003e\n\u003cli\u003eReal-time load current monitoring per group\u003c\/li\u003e\n\u003cli\u003eTemperature monitoring for thermal protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSystem Integration \u0026amp; Memory\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMemory requirement: 2 output words and 2 input words\u003c\/li\u003e\n\u003cli\u003eBackplane current: 500 mA maximum consumption\u003c\/li\u003e\n\u003cli\u003eInductive load formula: L = 0.5\/(I² × f) for safe operation\u003c\/li\u003e\n\u003cli\u003eTungsten load support: 2.5W to 6W depending on voltage\u003c\/li\u003e\n\u003cli\u003eStandard Quantum form factor for easy installation\u003c\/li\u003e\n\u003cli\u003eNegative logic sinking outputs for standard DC loads\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eShipping \u0026amp; Warranty Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFactory new \u003cstrong\u003e140DVO85300\u003c\/strong\u003e module in protective packaging\u003c\/li\u003e\n\u003cli\u003ePackage dimensions: 12.28\" × 6.42\" × 1.77\" (31.2 × 16.3 × 4.5 cm)\u003c\/li\u003e\n\u003cli\u003eShipping weight: 15.9 ounces (452 grams)\u003c\/li\u003e\n\u003cli\u003eExpress delivery via FedEx, UPS, and DHL available worldwide\u003c\/li\u003e\n\u003cli\u003eComplete 12-month product warranty with technical support\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eExpert Application Guidance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eWhat types of industrial loads work best with this high-density module?\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eThis module excels at controlling multiple small DC solenoids, indicator lights, relay coils, and electronic devices simultaneously.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eHow does the four-group isolation benefit complex control systems?\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eSeparate group protection prevents fault propagation and allows different voltage levels within the same module.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eWhat installation practices ensure optimal heat management?\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eMaintain proper spacing between modules and ensure adequate cabinet ventilation to handle maximum power dissipation.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eHow does the module handle incandescent lamp loads during startup?\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eThe surge current rating accommodates initial high inrush currents typical of tungsten filament lamps.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eWhat diagnostic information helps maintenance teams quickly identify issues?\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eIndividual channel LEDs and group fault indicators pinpoint specific problems without requiring additional test equipment.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e© 2025 Ubest Automation Limited. All rights reserved.\u003cbr\u003eOriginal Source: \u003ca href=\"https:\/\/www.ubestplc.com\/\"\u003ehttps:\/\/www.ubestplc.com\/\u003c\/a\u003e\u003cbr\u003eContact: \u003ca href=\"mailto:sales@ubestplc.com\"\u003esales@ubestplc.com\u003c\/a\u003e Phone: \u003ca href=\"https:\/\/wa.me\/8618030005825\"\u003e+86 180 3000 5825\u003c\/a\u003e\u003c\/p\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":51305770549530,"sku":"140DVO85300","price":176.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/140DVO85300_3.jpg?v=1762915061","url":"https:\/\/www.ubestplc.com\/ms\/products\/schneider-electric-dc-output-module-32-point-140dvo85300","provider":"Ubest Automation Limited","version":"1.0","type":"link"}