{"product_id":"07-kp-93-abb-07kp93-communication-process-mobus","title":"07 KP 93 ABB 07KP93 Communication Process MOBUS","description":"\u003ch3\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e· The RCOM 07 KP 90 GJR5253200R1161 R303 communication module can be planned as RCOM master or slave.\u003c\/li\u003e\n\u003cli\u003e· A network may have up to 254 RCOM slaves (max. 8 slaves if using MasterPiece 200, max. 30 slaves in case of dial-up mode).\u003c\/li\u003e\n\u003cli\u003e· The RCOM protocol is compatible with MP200\/1 with DSCA 180A. All RCOM services are available (cold start, warm start, normalization, clock synchronization, write data, read data, event polling).\u003c\/li\u003e\n\u003cli\u003e· The RCOM interface for connection of the modem complies with EIA RS-232. It can also be used as an EIA RS-485 interface.\u003c\/li\u003e\n\u003cli\u003e· An additional operator interface (CONSOLE) complying with EIA RS-232 is provided as a commissioning aid (indication of the communication sequence, planning telephone numbers, etc.)\u003c\/li\u003e\n\u003cli\u003e· Software clock; time can be used in the PLC program.\u003c\/li\u003e\n\u003cli\u003e· Differences between RCOM and RCOM+, see \"System technology \/ External couplers \/ 07 KP 90\". All other features of RCOM which are not mentioned in the chapter “Differences” apply correspondingly for RCOM+.\u003c\/li\u003e\n\u003cli\u003e· The function block RCOM+ can be used with the communication module 07 KP 90 from index b up.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003e\u003cstrong\u003eGeneral Data\u003c\/strong\u003e\u003c\/h3\u003e\u003ctable height=\"171\" style=\"width: 100.547%;\" data-mce-style=\"width: 100.547%;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"width: 47.048%;\" data-mce-style=\"width: 47.048%;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"width: 52.583%;\" data-mce-style=\"width: 52.583%;\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.048%;\" data-mce-style=\"width: 47.048%;\"\u003eNumber of serial interfaces\u003c\/td\u003e\n\u003ctd style=\"width: 52.583%;\" data-mce-style=\"width: 52.583%;\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.048%;\" data-mce-style=\"width: 47.048%;\"\u003eNumber of parallel interfaces\u003c\/td\u003e\n\u003ctd style=\"width: 52.583%;\" data-mce-style=\"width: 52.583%;\"\u003e1 networking interface for connecting to the Advant Controller 31 basic unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.048%;\" data-mce-style=\"width: 47.048%;\"\u003eOperating and error displays\u003c\/td\u003e\n\u003ctd style=\"width: 52.583%;\" data-mce-style=\"width: 52.583%;\"\u003e6 LEDs: RUN, ERR, Supply, RxD, TxD, BLK\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.048%;\" data-mce-style=\"width: 47.048%;\"\u003eConductor cross section for the removable terminal blocks\u003c\/td\u003e\n\u003ctd style=\"width: 52.583%;\" data-mce-style=\"width: 52.583%;\"\u003emax. 2.5 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003e\u003cstrong\u003ePower Supply for 07 KP 90 R303\u003c\/strong\u003e\u003c\/h3\u003e\u003ctable style=\"width: 100.547%;\" height=\"159\" data-mce-style=\"width: 100.547%;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"width: 68.4502%;\" data-mce-style=\"width: 68.4502%;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"width: 31.1808%;\" data-mce-style=\"width: 31.1808%;\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 68.4502%;\" data-mce-style=\"width: 68.4502%;\"\u003eRated supply voltage\u003c\/td\u003e\n\u003ctd style=\"width: 31.1808%;\" data-mce-style=\"width: 31.1808%;\"\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 68.4502%;\" data-mce-style=\"width: 68.4502%;\"\u003ePower dissipation\u003c\/td\u003e\n\u003ctd style=\"width: 31.1808%;\" data-mce-style=\"width: 31.1808%;\"\u003etyp. 2.5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 68.4502%;\" data-mce-style=\"width: 68.4502%;\"\u003eMax. current consumption with rated voltage\u003c\/td\u003e\n\u003ctd style=\"width: 31.1808%;\" data-mce-style=\"width: 31.1808%;\"\u003e210 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 68.4502%;\" data-mce-style=\"width: 68.4502%;\"\u003eMax. current consumption with a supply voltage of 30 V\u003c\/td\u003e\n\u003ctd style=\"width: 31.1808%;\" data-mce-style=\"width: 31.1808%;\"\u003e170 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 68.4502%;\" data-mce-style=\"width: 68.4502%;\"\u003eProtection against reversed terminal connection\u003c\/td\u003e\n\u003ctd style=\"width: 31.1808%;\" data-mce-style=\"width: 31.1808%;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003e\u003cstrong\u003eSerial Interfaces RCOM and CONSOLE\u003c\/strong\u003e\u003c\/h3\u003e\u003ctable height=\"296\" style=\"width: 100.547%;\" data-mce-style=\"width: 100.547%;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"width: 32.1033%;\" data-mce-style=\"width: 32.1033%;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"width: 67.5277%;\" data-mce-style=\"width: 67.5277%;\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 32.1033%;\" data-mce-style=\"width: 32.1033%;\"\u003eInterface standard\u003c\/td\u003e\n\u003ctd style=\"width: 67.5277%;\" data-mce-style=\"width: 67.5277%;\"\u003eEIA RS-232 or EIA RS-485 (RCOM only)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 32.1033%;\" data-mce-style=\"width: 32.1033%;\"\u003eElectrical isolation\u003c\/td\u003e\n\u003ctd style=\"width: 67.5277%;\" data-mce-style=\"width: 67.5277%;\"\u003eYes, RCOM interface with respect to the rest of the unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 32.1033%;\" data-mce-style=\"width: 32.1033%;\"\u003ePotential differences\u003c\/td\u003e\n\u003ctd style=\"width: 67.5277%;\" data-mce-style=\"width: 67.5277%;\"\u003eNo earthing potential differences arise between the 07 KP 90 R303 and the peripheral units connected to RCOM and CONSOLE. They are supplied from the switch-gear cabinet mains socket.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 32.1033%;\" data-mce-style=\"width: 32.1033%;\"\u003eTransmission speed (Baud rate)\u003c\/td\u003e\n\u003ctd style=\"width: 67.5277%;\" data-mce-style=\"width: 67.5277%;\"\u003eRCOM: 300...19200 Baud, CONSOLE: 9600 Baud\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 32.1033%;\" data-mce-style=\"width: 32.1033%;\"\u003eTerminal assignment and description of the interfaces RCOM, CONSOLE\u003c\/td\u003e\n\u003ctd style=\"width: 67.5277%;\" data-mce-style=\"width: 67.5277%;\"\u003eSee page 7.1-8 onwards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003e\u003cstrong\u003eLED Displays\u003c\/strong\u003e\u003c\/h3\u003e\u003ctable style=\"width: 100.547%;\" height=\"160\" data-mce-style=\"width: 100.547%;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"width: 65.3137%;\" data-mce-style=\"width: 65.3137%;\"\u003eLED\u003c\/th\u003e\n\u003cth style=\"width: 34.3173%;\" data-mce-style=\"width: 34.3173%;\"\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 65.3137%;\" data-mce-style=\"width: 65.3137%;\"\u003eSupply voltage present (Supply)\u003c\/td\u003e\n\u003ctd style=\"width: 34.3173%;\" data-mce-style=\"width: 34.3173%;\"\u003e1 green LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 65.3137%;\" data-mce-style=\"width: 65.3137%;\"\u003eFatal or serious error occurred (ERR)\u003c\/td\u003e\n\u003ctd style=\"width: 34.3173%;\" data-mce-style=\"width: 34.3173%;\"\u003e1 red LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 65.3137%;\" data-mce-style=\"width: 65.3137%;\"\u003eReady for RCOM communication (running) (RUN)\u003c\/td\u003e\n\u003ctd style=\"width: 34.3173%;\" data-mce-style=\"width: 34.3173%;\"\u003e1 green LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 65.3137%;\" data-mce-style=\"width: 65.3137%;\"\u003eInterface signals RxD, TxD\u003c\/td\u003e\n\u003ctd style=\"width: 34.3173%;\" data-mce-style=\"width: 34.3173%;\"\u003e2 yellow LEDs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 65.3137%;\" data-mce-style=\"width: 65.3137%;\"\u003eProtocol status BLK\u003c\/td\u003e\n\u003ctd style=\"width: 34.3173%;\" data-mce-style=\"width: 34.3173%;\"\u003e1 yellow LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003e\u003cstrong\u003eMechanical Data\u003c\/strong\u003e\u003c\/h3\u003e\u003ctable style=\"width: 100%;\" data-mce-style=\"width: 100%;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"width: 28.0241%;\" data-mce-style=\"width: 28.0241%;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"width: 71.6069%;\" data-mce-style=\"width: 71.6069%;\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 28.0241%;\" data-mce-style=\"width: 28.0241%;\"\u003eMounting\u003c\/td\u003e\n\u003ctd style=\"width: 71.6069%;\" data-mce-style=\"width: 71.6069%;\"\u003eOn DIN rail in accordance with DIN EN 50022–35, 15 mm deep. The DIN rail is located in the middle between the upper and the lower edges of the module.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 28.0241%;\" data-mce-style=\"width: 28.0241%;\"\u003eFastening\u003c\/td\u003e\n\u003ctd style=\"width: 71.6069%;\" data-mce-style=\"width: 71.6069%;\"\u003eBy screws using 4 M4 screws\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 28.0241%;\" data-mce-style=\"width: 28.0241%;\"\u003eWidth x height x depth\u003c\/td\u003e\n\u003ctd style=\"width: 71.6069%;\" data-mce-style=\"width: 71.6069%;\"\u003e140 x 120 x 85 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 28.0241%;\" data-mce-style=\"width: 28.0241%;\"\u003eWiring method\u003c\/td\u003e\n\u003ctd style=\"width: 71.6069%;\" data-mce-style=\"width: 71.6069%;\"\u003eBy removable terminal blocks with screw-type terminals, max. 2.5 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 28.0241%;\" data-mce-style=\"width: 28.0241%;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"width: 71.6069%;\" data-mce-style=\"width: 71.6069%;\"\u003e450 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":49180482109722,"sku":"07-KP-93","price":200.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/07KT98GJR5253100R0160_1.jpg?v=1718442190","url":"https:\/\/www.ubestplc.com\/products\/07-kp-93-abb-07kp93-communication-process-mobus","provider":"Ubest Automation Limited","version":"1.0","type":"link"}