{"product_id":"3300-xl-8-mm-proximitor-probe-bently-nevada-330103-00-10-15-02-05","title":"3300 XL 8 mm Proximitor Probe | Bently Nevada 330103-00-10-15-02-05","description":"\u003ch2\u003ePrecision Vibration Monitoring: \u003cstrong\u003eBently Nevada 330103-00-10-15-02-05\u003c\/strong\u003e\n\u003c\/h2\u003e\n\u003ch3\u003eComplete suffix tree: \u003cstrong\u003e330103-00-10-15-02-05\u003c\/strong\u003e breakdown\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e330103\u003c\/strong\u003e = 3300 XL 8 mm Probe, M10 x 1 thread, standard case (no armor)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e00\u003c\/strong\u003e = Unthreaded length: 0 mm (minimum unthreaded option)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e10\u003c\/strong\u003e = Overall case length: 100 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e15\u003c\/strong\u003e = Total cable length: 1.5 meter (4.9 feet)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e02\u003c\/strong\u003e = Miniature coaxial ClickLoc™ connector, standard cable\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e05\u003c\/strong\u003e = Agency approvals: CSA, ATEX, IECEx\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical highlights (engineered for reliability)\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #b22222;\"\u003e\u003cstrong\u003eBrand \u0026amp; series:\u003c\/strong\u003e\u003c\/span\u003e Bently Nevada, 3300 XL 8 mm Proximity Probes – metric thread M10x1.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #b22222;\"\u003e\u003cstrong\u003eLinear range:\u003c\/strong\u003e\u003c\/span\u003e 2 mm (80 mils), starting at 0.25 mm from target. Output –1 to –17 Vdc.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #b22222;\"\u003e\u003cstrong\u003eRecommended gap:\u003c\/strong\u003e\u003c\/span\u003e –9 Vdc (approx. 1.27 mm \/ 50 mils) for radial vibration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #b22222;\"\u003e\u003cstrong\u003eDC resistance (RPROBE):\u003c\/strong\u003e\u003c\/span\u003e 7.73 Ω ± 0.50 (1.5 m probe length).\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #b22222;\"\u003e\u003cstrong\u003eTip material:\u003c\/strong\u003e\u003c\/span\u003e Polyphenylene sulfide (PPS); case: AISI 303\/304 SST.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #b22222;\"\u003e\u003cstrong\u003eTemperature range (standard):\u003c\/strong\u003e\u003c\/span\u003e –52 °C to +177 °C (–62 °F to +350 °F). Extended tip version withstands up to +218 °C.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #b22222;\"\u003e\u003cstrong\u003eSealing \u0026amp; humidity:\u003c\/strong\u003e\u003c\/span\u003e Viton® O‑ring seals differential pressure. \u0026lt;3% ASF change after 56 days at 93% RH (IEC 68‑2‑3).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField wiring \u0026amp; system integration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUse 3‑conductor shielded triad cable, 0.2…1.5 mm² (16–24 AWG), tinned ends.\u003c\/li\u003e\n\u003cli\u003eMaximum extension between \u003cstrong\u003e3300 XL Proximitor Sensor\u003c\/strong\u003e and monitor: 305 m (1,000 ft).\u003c\/li\u003e\n\u003cli\u003eFrequency response graphs show signal roll‑off at high frequencies with longer wiring; refer to Figures 10 \u0026amp; 12 in manual.\u003c\/li\u003e\n\u003cli\u003eIntrinsically safe installations: Class I, Zone 0 (AEx\/Ex ia IIC T5…T1 Ga) when used with zener barriers (drwg 141092) or galvanic isolators.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently asked questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Can I use this probe with existing 3300 XL monitors?\u003c\/strong\u003e\u003cbr\u003eA: Yes, the \u003cstrong\u003e3300 XL 8 mm Proximity Probes\u003c\/strong\u003e are fully backward compatible with all 3300 XL Proximitor sensors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the maximum cable extension without signal degradation?\u003c\/strong\u003e\u003cbr\u003eA: You can extend up to 305 meters (1000 feet) using recommended shielded triad cable. For high‑frequency response, consult the manual graphs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Does the probe work in high‑humidity areas?\u003c\/strong\u003e\u003cbr\u003eA: Absolutely. It passes IEC 68‑2‑3 56‑day damp heat test with less than 3% Average Scale Factor change.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Which torque value should I use for the M10x1 thread?\u003c\/strong\u003e\u003cbr\u003eA: Bently Nevada recommends hand‑tight plus 1\/8 turn maximum. Never exceed 15 mm thread engagement.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAuthor: Ubest Automation\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e© 2026 Ubest Automation Limited. \u003ca href=\"https:\/\/www.ubestplc.com\/\"\u003ehttps:\/\/www.ubestplc.com\/\u003c\/a\u003e All rights reserved.\u003c\/strong\u003e\u003cbr\u003eContact: \u003ca href=\"mailto:sales@ubestplc.com\"\u003esales@ubestplc.com\u003c\/a\u003e Phone: \u003ca href=\"https:\/\/wa.me\/8618030005825\"\u003e+86 180 3000 5825\u003c\/a\u003e\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":51764238516506,"sku":"330103-00-10-15-02-05","price":236.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/330103-00-10-15-02-05.jpg?v=1772158669","url":"https:\/\/www.ubestplc.com\/products\/3300-xl-8-mm-proximitor-probe-bently-nevada-330103-00-10-15-02-05","provider":"Ubest Automation Limited","version":"1.0","type":"link"}