The Bently Nevada Reverse Mount Probes, specifically the model 330106-05-30-15-12-05, are designed for precision measurement and monitoring applications in industrial environments. Manufactured in the U.S.A, these advanced probes provide reliable performance under diverse operating conditions.

Technical Specifications

  • Manufacturer: Bently Nevada

  • Brand: Bently Nevada

  • Model: 330106-05-30-15-12-05

    • 330106-05-30: Connector Option (M10 x 1 threads)
    • 15: Total Length Option (1.5 meters / 4.9 feet)
    • 12: Connector Type (Miniature ClickLoc coaxial, FluidLoc cable)
    • 05: Agency Approval (CSA, ATEX, IECEx)
  • Dimensions: 20.4 cm x 22.2 cm x 3.7 cm

  • Weight: 0.323 kg

  • Nominal Probe DC Resistance:

    • Resistor (RPROBE): 7.73 ± 0.50 Ω at 1.5 m
  • Materials:

    • Probe Tip Material: Polyphenylene Sulfide (PPS)
    • Probe Case Material: AISI 303 or 304 Stainless Steel (SST)
  • Mechanical Specifications:

    • Maximum Torque:
      • Rated: 22.6 N•m (200 in•lbf)
      • Recommended: 7.5 N•m (66 in•lbf)
    • Thread: M10x1
    • Maximum Length of Thread Engagement: 15 mm
  • Temperature Range:

    • Standard Operating/Storage Temperature: -52°C to +177°C (-62°F to +350°F)
    • Extended Temperature Range:
      • Probe Tip: -52°C to +218°C (-62°F to +425°F)
      • Probe Cable and Connector: -51°C to +260°C (-60°F to +500°F)
  • Pressure Sealing:

    • Designed for sealing differential pressure between the probe tip and case using a Viton® O-ring.
    • Probes are not pressure tested prior to shipment; custom testing available upon request.
  • Relative Humidity:

    • Less than 3% change in Average Scale Factor (ASF) when tested in 93% humidity in accordance with IEC standard 68 2 3 for up to 56 days.