{"product_id":"330704-000-100-10-01-ru-bently-nevada-3300-xl-11-mm-armored-probe","title":"330704-000-100-10-01-RU Bently Nevada 3300 XL 11 mm Armored Probe","description":"\u003ch2\u003e\u003cstrong\u003eBently Nevada 3300 XL 11 mm Armored Probe – Rugged Metric Series with RU Approval\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications \u0026amp; Complete Suffix Information\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e \u003cspan style=\"color: #cc0000;\"\u003eBently Nevada\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel (Full Part Number):\u003c\/strong\u003e \u003cstrong style=\"color: #cc0000;\"\u003e330704-000-100-10-01-RU\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eComplete Suffix Breakdown (Tree Structure):\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e330704\u003c\/strong\u003e – 3300 XL 11 mm Probe, M14 x 1.5 thread, \u003cspan style=\"color: #cc0000;\"\u003ewith armor\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e000\u003c\/strong\u003e – Unthreaded Length Option: 00 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e100\u003c\/strong\u003e – Overall Case Length: \u003cstrong\u003e100 mm\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e10\u003c\/strong\u003e – Total Length: \u003cstrong\u003e1.0 meter\u003c\/strong\u003e (3.3 feet)\u003cbr\u003e– Designed for one-meter Proximitor Sensor systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e01\u003c\/strong\u003e – Connector \u0026amp; Cable: Miniature coaxial ClickLoc connector with connector protector, standard cable\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRU\u003c\/strong\u003e – Agency Approval: \u003cstrong\u003eCountry specific – RU approval\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eProbe DC Resistance \u0026amp; Electrical Characteristics\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eProbe Length: \u003cstrong\u003e1.0 meter\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eResistance (Center to Outer Conductor – RPROBE): \u003cstrong\u003e5.9 ± 0.5 ohms\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e60 Hz Magnetic Field Immunity (reference for 5-meter system):\n\u003cul\u003e\n\u003cli\u003eGap 0.5 mm (20 mil): \u003cstrong\u003e0.001\u003c\/strong\u003e output V pp\/gauss\u003c\/li\u003e\n\u003cli\u003eGap 2.5 mm (100 mil): \u003cstrong\u003e0.009\u003c\/strong\u003e output V pp\/gauss\u003c\/li\u003e\n\u003cli\u003eGap 4.6 mm (180 mil): \u003cstrong\u003e0.027\u003c\/strong\u003e output V pp\/gauss\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eExcellent \u003cspan style=\"color: #cc0000;\"\u003eelectromagnetic interference immunity\u003c\/span\u003e for reliable operation near motors and generators\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eMechanical \u0026amp; Material Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eProbe Tip Material:\u003c\/strong\u003e Polyphenylene sulfide (PPS) – offers superior chemical resistance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProbe Case Material:\u003c\/strong\u003e AISI 304 stainless steel (SST) with \u003cstrong\u003efull armor protection\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProbe Cable:\u003c\/strong\u003e 75 Ω triaxial, FEP insulated – available in 1, 5, or 9 meter total lengths\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProbe Case Thread:\u003c\/strong\u003e M14 x 1.5\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Thread Engagement Length:\u003c\/strong\u003e 21 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProbe Case Torque:\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eMaximum Rated: \u003cstrong\u003e63.3 N•m\u003c\/strong\u003e (560 in•lb)\u003c\/li\u003e\n\u003cli\u003eRecommended: \u003cstrong\u003e21.1 N•m\u003c\/strong\u003e (187 in•lb)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTemperature Range \u0026amp; Environmental Tolerance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating \u0026amp; Storage Temperature:\u003c\/strong\u003e \u003cspan style=\"color: #cc0000;\"\u003e-52°C to +177°C\u003c\/span\u003e (-62°F to +351°F)\u003c\/li\u003e\n\u003cli\u003eExposing the probe below -34°C (30°F) may cause premature pressure seal failure\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature Classification (EPL Ga\/Gc):\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eT1: -55°C to +232°C\u003c\/li\u003e\n\u003cli\u003eT2: -55°C to +177°C\u003c\/li\u003e\n\u003cli\u003eT3: -55°C to +120°C\u003c\/li\u003e\n\u003cli\u003eT4: -55°C to +80°C\u003c\/li\u003e\n\u003cli\u003eT5: -55°C to +40°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature Classification (EPL Dc):\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eT280°C @ Ta: -55°C to +232°C\u003c\/li\u003e\n\u003cli\u003eT225°C @ Ta: -55°C to +177°C\u003c\/li\u003e\n\u003cli\u003eT170°C @ Ta: -55°C to +120°C\u003c\/li\u003e\n\u003cli\u003eT130°C @ Ta: -55°C to +80°C\u003c\/li\u003e\n\u003cli\u003eT105°C @ Ta: -55°C to +100°C\u003c\/li\u003e\n\u003cli\u003eT90°C @ Ta: -55°C to +40°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions (FAQ)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What makes this armored probe different from standard versions?\u003c\/strong\u003e\u003cbr\u003eA: Model \u003cstrong\u003e330704-000-100-10-01-RU\u003c\/strong\u003e features full armor protection for harsh industrial environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What does the RU suffix indicate?\u003c\/strong\u003e\u003cbr\u003eA: RU denotes country-specific approvals for regional compliance requirements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the maximum operating temperature?\u003c\/strong\u003e\u003cbr\u003eA: The probe supports up to \u003cstrong\u003e+177°C\u003c\/strong\u003e for continuous operation under T2 classification.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Is this a genuine Bently Nevada product?\u003c\/strong\u003e\u003cbr\u003eA: Yes, we supply only new and original units in factory packing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the probe's DC resistance value?\u003c\/strong\u003e\u003cbr\u003eA: For the 1-meter version, resistance from center to outer conductor is \u003cstrong\u003e5.9 ± 0.5 ohms\u003c\/strong\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e© 2026 Ubest Automation Limited. \u003ca style=\"color: #0066cc; text-decoration: none;\" href=\"https:\/\/www.ubestplc.com\/\"\u003ehttps:\/\/www.ubestplc.com\/\u003c\/a\u003e All rights reserved.\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eContact:\u003c\/strong\u003e \u003ca style=\"color: #0066cc; text-decoration: none;\" href=\"mailto:sales@ubestplc.com\"\u003esales@ubestplc.com\u003c\/a\u003e | \u003cstrong\u003ePhone:\u003c\/strong\u003e \u003ca style=\"color: #0066cc; text-decoration: none;\" href=\"https:\/\/wa.me\/8618030005825?text=Inquiry%20about%20330704-000-100-10-01-RU\"\u003e+86 180 3000 5825\u003c\/a\u003e\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":51864177475866,"sku":"330704-000-100-10-01-RU","price":362.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/330704-000-100-10-01-RU.jpg?v=1774407974","url":"https:\/\/www.ubestplc.com\/products\/330704-000-100-10-01-ru-bently-nevada-3300-xl-11-mm-armored-probe","provider":"Ubest Automation Limited","version":"1.0","type":"link"}