330905-05-13-05-12-00 3300 NSv Probe Without Armor
Manufacturer:
Bently Nevada
Product No.:
330905-05-13-05-12-00
Condition:
In Stock
Product Type:
3300 NSv Probe
Product Origin:
USA
Weight:
323g
Shipping port:
Xiamen
Warranty:
12 months
UBEST – Trusted Global Automation Parts Supplier
We offer a wide range of in-stock industrial automation spare parts. All products come with a 12-month warranty and a 30-day refund for quality issues.
Bently Nevada 330905-05-13-05-12-00: Industrial Vibration Probe
🔍 Part Number Breakdown
- 330905 - NSv Probe Series
- 05 - 50 mm Unthreaded Length
- 13 - 130 mm Case Length
- 05 - 0.5 Meter Cable
- 12 - FluidLoc™ Cable + ClickLoc Connector
- 00 - No Agency Certs
⚙️ Enhanced Technical Specs
| Electrical Resistance | 4.0Ω ±0.5 (Probe) |
| Cable Capacitance | 69.9 pF/m |
| Thread Engagement | 15 mm Max |
| Pressure Seal | Viton® O-ring (Untested) |
| Shock Tolerance | 100g (11ms) |
🆚 Model Comparison
| Model | Key Feature | Best For |
|---|---|---|
| 330905-00-25-10-01-05 | 250mm Case + 1m Cable | Deep boreholes |
| 330905-00-10-10-02-00 | 100mm Case + 1m Cable | Compact machinery |
| 330905-00-15-05-02-00 | 150mm Case + 0.5m Cable | Mid-depth installations |
| THIS MODEL: 330905-05-13-05-12-00 | FluidLoc™ Cable | Wet/chemical environments |
⚠️ Critical Installation Notes
- Torque Limit: 0.56 N•m max (finger-tight only)
- Optimal Gap: Set at 1.0 mm (40 mils) from target
- Bend Radius: >25.4 mm to prevent cable damage
- Wiring: Use shielded triad cable (max 305m)
📦 Package & Warranty
- Factory-sealed new probe
- Installation documentation
- Warranty: 12 months
- Global Shipping: FedEx/UPS/DHL (2-5 business days)
❓ Technical FAQs
Q: Does FluidLoc™ cable resist oil exposure?
A: Yes - designed for direct contact with lube oils and solvents
Q: Can I retrofit this to replace 3300 RAM probes?
A: ✅ Fully compatible - no system modifications needed
Q: Minimum target size for accurate readings?
A: 8.9 mm diameter - use 13 mm for optimal results
Q: How does temperature affect calibration?
A: <0.5% drift across full operating range (-52°C to +177°C)