{"product_id":"abb-ao815-3bse052605r1-s800-analog-output-module","title":"ABB AO815 3BSE052605R1 S800 Analog Output Module","description":"\u003ch2\u003e\u003cstrong\u003eAO815 3BSE052605R1 Analog Output Module\u003c\/strong\u003e\u003c\/h2\u003e\u003ch3\u003e\u003cstrong\u003eDescription \u003c\/strong\u003e\u003c\/h3\u003e\u003cp\u003eThe AO815 Analog Output Module features 8 unipolar analog output channels. The module performs self-diagnostic cyclically.\u003c\/p\u003e\u003ch3\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e8 channels of 4...20 mA outputs.\u003c\/li\u003e\n\u003cli\u003eOSP sets outputs to predetermined state upon error detection.\u003c\/li\u003e\n\u003cli\u003e1 group of 8 channels isolated from ground.\u003c\/li\u003e\n\u003cli\u003eAnalog Output is short circuit secured to ZP or +24 V.\u003c\/li\u003e\n\u003cli\u003e12-bit resolution.\u003c\/li\u003e\n\u003cli\u003eHART pass-through communication.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003e\u003cstrong\u003eModule diagnostics include:\u003c\/strong\u003e\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eExternal Channel Error:\u003c\/strong\u003e Reported (only on active channels) if the process power supply voltage to output circuitry is too low or the output current is less than the output set value and the output set value is greater than 1 mA (open circuit).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInternal Channel Error:\u003c\/strong\u003e Reported if the output circuit cannot provide the correct current value.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Error:\u003c\/strong\u003e Reported in case of Output Transistor Error, Short Circuit, Checksum Error, Internal Power Supply Error, or Watchdog error.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eThe module supports HART pass-through functionality with point-to-point communication. The output filter must be enabled on channels used for HART communication. Shielded field cables are required for process connections if HART is used.\u003c\/p\u003e\u003cp\u003eFour different types of MTUs can be used: TU830 Extended MTU and TU810 (or TU814) Compact MTU for wire connection without additional terminals, and TU812 Compact MTU with a D-Sub 25 pin (male) connector for process connection.\u003c\/p\u003e\u003ch3\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eAO815 Analog Output Module Specifications at 25°C\u003c\/strong\u003e\u003c\/p\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eAO815 Analog Output Module\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNumber of channels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4...20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOver range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±15%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput load\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMax 750 ohms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum field cable length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600 meters (656 yd.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRise time output filter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e- disable: 23 ms (0-90%)\u003c\/p\u003e\n\u003cp\u003e- enable: max 4 mA \/ 12.5 ms\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCycle time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eError\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMax. 0.1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12 bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Set as Predetermined (OSP) timer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e256, 512, 1024 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature drift\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMax. 50 ppm\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent consumption 24 V (process power supply, UPx)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e165 mA (max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent consumption 5 V (Modulebus)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e125 mA (max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower dissipation (1)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGroupwise isolated from ground\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting termination units\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTU810, TU812, TU814, TU830, and TU833\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMTU keying code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRated insulation voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDielectric test voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500 V a.c.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":49132874465562,"sku":"AO815","price":200.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/AO815_1.jpg?v=1717837005","url":"https:\/\/www.ubestplc.com\/products\/abb-ao815-3bse052605r1-s800-analog-output-module","provider":"Ubest Automation Limited","version":"1.0","type":"link"}