{"product_id":"alf111-s00-foundation-fieldbus-communication-module","title":"ALF111-S00 | Foundation Fieldbus Communication Module","description":"\u003ch2 style=\"font-weight: bold;\"\u003eYokogawa ALF111 Specifications\u003c\/h2\u003e\u003cp\u003e\u003c\/p\u003e\u003ch2 style=\"font-weight: bold; display: inline;\"\u003e\n\u003cspan style=\"font-weight: bold; color: #e53935; font-size: 12px;\"\u003eYokogawa\u003c\/span\u003e General Information\u003c\/h2\u003e\u003ctable style=\"width: 100%; border-collapse: collapse; background-color: rgb(224, 247, 250); margin-bottom: 20px; height: 39.1876px;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background-color: rgb(187, 222, 251); height: 19.5938px;\"\u003e\n\u003cth style=\"padding: 10px; border: 1px solid rgb(30, 136, 229); text-align: left; height: 19.5938px;\"\u003eModel\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid rgb(30, 136, 229); text-align: left; height: 19.5938px;\"\u003eALF111-S00\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\u003ctr style=\"background-color: rgb(255, 255, 255); height: 19.5938px;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid rgb(30, 136, 229); height: 19.5938px;\"\u003eDescription\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid rgb(30, 136, 229); height: 19.5938px;\"\u003eFoundation Fieldbus Communication Module (N-IO\/FIO)\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2 style=\"font-weight: bold; display: inline;\"\u003e\n\u003cspan style=\"font-weight: bold; color: #e53935; font-size: 12px;\"\u003eYokogawa\u003c\/span\u003e Technical Specifications\u003c\/h2\u003e\u003ctable style=\"width: 100%; border-collapse: collapse; background-color: #e0f7fa;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background-color: #bbdefb;\"\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #1e88e5; text-align: left;\"\u003eItem\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #1e88e5; text-align: left;\"\u003eSpecifications\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #ffffff;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #1e88e5;\"\u003eInterface\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #1e88e5;\"\u003eFOUNDATION fieldbus (low speed voltage mode), 4 ports (1 segment per port)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #bbdefb;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #1e88e5;\"\u003eTransmission Speed\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #1e88e5;\"\u003e31.25 kbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #ffffff;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #1e88e5;\"\u003eWithstanding Voltage\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #1e88e5;\"\u003eFrom field to system: 1500 V AC\/minute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #bbdefb;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #1e88e5;\"\u003eBus Connection (External Connection)\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #1e88e5;\"\u003e\u003cul\u003e\n\u003cli\u003ePressure clamp terminals (removable terminal block with built-in terminators that can be switched on\/off)\u003c\/li\u003e\n\u003cli\u003eConnects with terminal board via a dedicated cable\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #ffffff;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #1e88e5;\"\u003eInstallation Method\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #1e88e5;\"\u003eMounted on ANB10□1, ANB11□1, AFV30□1, AFV40□1, A2FV50□1, or A2FV70□1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #bbdefb;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #1e88e5;\"\u003eNo. of Control I\/O Channels\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #1e88e5;\"\u003eMax. 48 points\/segment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #ffffff;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #1e88e5;\"\u003eNo. of Fieldbus Devices\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #1e88e5;\"\u003eMax. 32 units per segment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #bbdefb;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #1e88e5;\"\u003eCommunication Functions\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1 px solid #1e88e5;\"\u003eLAS function, Clock master function\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #ffffff;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1 px solid #1e88e5;\"\u003eDual-Redundancy\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1 px solid #1e88e5;\"\u003eEnabled to set up two units of ALF111 installed in the annexed slots in the same node unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #bbdefb;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1 px solid #1e88e5;\"\u003eCurrent Consumption\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1 px solid #1e88e5;\"\u003e0.5 A or less\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #ffffff;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1 px solid #1e88e5;\"\u003eWithstanding Voltage\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1 px solid #1e88e5;\"\u003e\u003cul\u003e\n\u003cli\u003eBetween primary side and secondary side\u003c\/li\u003e\n\u003cli\u003eBetween channel and channel: 1500 V AC for 1 minute\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #bbdefb;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1 px solid #1e88e5;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1 px solid #1e88e5;\"\u003eApprox. 0.40 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch2 style=\"font-weight: bold; display: inline;\"\u003e\n\u003cspan style=\"font-weight: bold; color: #e53935; font-size: 12px;\"\u003eYokogawa\u003c\/span\u003e Suffix Codes\u003c\/h2\u003e\u003ctable style=\"width: 100%; border-collapse: collapse; background-color: #e0f7fa;\"\u003e\n\u003cthead\u003e\u003ctr style=\"background-color: #bbdefb;\"\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #1e88e5; text-align: left;\"\u003eCode\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1 px solid #1e88e5; text-align: left;\"\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #ffffff;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1 px solid #1e88e5;\"\u003e\u003cstrong\u003e-S\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1 px solid #1e88e5;\"\u003eStandard type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #bbdefb;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1 px solid #1e88e5;\"\u003e\u003cstrong\u003e0\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1 px solid #1e88e5;\"\u003eBasic type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #ffffff;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1 px solid #1e88e5;\"\u003e\u003cstrong\u003e0\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1 px solid #1e88e5;\"\u003eAlways 0 Basic type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":49499360198938,"sku":"ALF111-S00","price":23.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/ALE111-S50.jpg?v=1723777472","url":"https:\/\/www.ubestplc.com\/products\/alf111-s00-foundation-fieldbus-communication-module","provider":"Ubest Automation Limited","version":"1.0","type":"link"}