Bently Nevada 3300 XL 8mm Probe | 330101-00-77-20-02-CN
UBEST – Trusted Global Automation Parts Supplier
We offer a wide range of in-stock industrial automation spare parts. All products come with a 12-month warranty and a 30-day refund for quality issues.
Bently Nevada 3300 XL 8 mm Standard Proximity Probe
The Bently Nevada 3300 XL 8 mm proximity probe ensures precise vibration measurement. This model 330101-00-77-20-02-CN features a robust design without armor. It utilizes a standard cable with a secure ClickLoc connector for reliable connections. The probe's enhanced construction provides superior durability in industrial settings. Professionals choose Bently Nevada for accurate machinery health monitoring.
Model Configuration: 330101-00-77-20-02-CN
- 330101: Identifies the base 3300 XL 8 mm probe without armor.
- 00: Specifies an unthreaded length of 0.0 inches.
- 77: Indicates an overall case length of 7.7 inches.
- 20: Defines the total system cable length as 2.0 meters (6.6 feet).
- 02: Denotes a Miniature Coaxial ClickLoc connector with standard cable.
- CN: Signifies Country-Specific approval or documentation requirements.
Electrical Specifications & Performance
- Probe Resistance (RPROBE): 7.88 Ω ± 0.50 Ω for the 2.0m model.
- Cable Capacitance: Extension cable typical is 69.9 pF per meter (21.3 pF/ft).
- Linear Range: Provides a 2.0 mm (80 mil) linear measurement range.
- Recommended Gap: Set to -9 Vdc (approx. 1.27 mm / 50 mils) for radial vibration.
- Sensitivity (ISF): Standard system sensitivity is 7.87 V/mm (200 mV/mil) ±5%.
- Linearity (DSL): Deviation is less than ±0.025 mm (±1 mil) for standard systems.
Robust Mechanical Design
- Thread Type: Standard 3/8-24 UNF mounting thread.
- Probe Tip: Features a rugged Polyphenylene sulfide (PPS) molded tip.
- Probe Case: Constructed from AISI 303 or 304 stainless steel.
- Cable Strength: Patented CableLoc ensures 330 N (75 lbf) pull-off resistance.
- TipLoc Bonding: Patented molding creates a robust bond between tip and body.
- 8mm Advantage: Thicker encapsulation offers optimal robustness against physical damage.
Environmental Ratings & Operating Limits
- Standard Temperature: Operates from -52°C to +177°C (-62°F to +350°F).
- Extended Temperature: Option for tip up to +218°C (+425°F).
- Low-Temperature Note: Avoid below -34°C (-30°F) to prevent seal failure.
- Humidity Resistance: Less than 3% ASF change after 56 days at 93% humidity (IEC 68-2-3).
- Pressure Seal: Designed with a Viton® O-ring; not pressure tested before shipment.
Installation & Field Wiring Guidelines
- Field Wiring: Use 3-conductor shielded triad cable (16-24 AWG / 0.2-1.5 mm²).
- Wire Type: Tinned field wiring is recommended for better corrosion resistance.
- Maximum Distance: Up to 305 meters (1,000 feet) between probe and monitor.
- Signal Consideration: Long cable runs may affect high-frequency response; consult manual graphs.
- System Use: Compatible with standard 5, 1, and 9 meter system configurations.
Packaging & Shipping Details
- The Bently Nevada 3300 XL probe is packaged securely for industrial shipment.
- Includes the probe with standard cable and ClickLoc connector as specified.
- We ship internationally using reliable services like FedEx, UPS, and DHL.
- Complete tracking details are provided for all customer orders upon dispatch.
Frequently Asked Questions (FAQ)
What does the "CN" suffix mean in the model number?
- The "CN" suffix indicates Country-Specific requirements. This often pertains to documentation, certifications (like a Certificate of Origin), or labeling needed for import into specific countries.
What is the difference between standard cable and FluidLoc cable?
- A standard cable is for general use. The FluidLoc option (code '12') has a special sealant to prevent oil from traveling inside the cable, which is critical for wet or oily machinery applications.
Why is an 8 mm probe recommended over smaller sizes?
- The 3300 XL 8 mm probe has a thicker plastic tip and a larger, stronger stainless steel case. This design provides much better physical durability and protection against accidental damage during operation and maintenance.
How do I set the correct gap for this probe?
- For measuring radial vibration, adjust the probe's position until the system output reads -9 Vdc. This voltage corresponds to a gap of approximately 1.27 mm (50 mils), which is the recommended setting.
Can this probe be used in high-humidity environments?
- Yes. Testing shows less than a 3% change in performance after 56 days in 93% relative humidity. This makes the Bently Nevada probe suitable for damp industrial conditions.
© 2025 Ubest Automation Limited. All rights reserved.
Original Source: https://www.ubestplc.com/
Contact: sales@ubestplc.com | Phone: +86 180 3000 5825