Bently Nevada 3300 XL 9m Proximity Probe 330708-00-10-90-01-00

In stock
Manufacturer:
Bently Nevada
Product No.:
330708-00-10-90-01-00
Condition:
In Stock
Product Type:
Proximity Probe
Product Origin:
USA
Weight:
170g
Shipping port:
Xiamen
Warranty:
12 months

UBEST – Trusted Global Automation Parts Supplier

We offer a wide range of in-stock industrial automation spare parts. All products come with a 12-month warranty and a 30-day refund for quality issues.

About Us | Contact

Bently Nevada 3300 XL Long-Reach Proximity Probe 330708-00-10-90-01-00

Product Configuration & Suffix Decoder

  • Base Model: 330708 (11mm Probe, 5/8-18 UNF, No Armor)
  • Suffix -00: Unthreaded Shank Length = 0.0 inch
  • Suffix -10: Overall Case Length = 1.0 inch
  • Suffix -90: Total Cable Length = 9.0 meters (29.5 feet)
  • Suffix -01: Connector = ClickLoc with Protector, Standard Cable
  • Suffix -00: Agency Certification = Not Required

Core Technical Specifications

  • Manufacturer & Series: Bently Nevada 3300 XL
  • Full Part Number: 330708-00-10-90-01-00
  • Probe Type: 11 mm Diameter Eddy-Current Sensor
  • Cable System: 75 Ω Triaxial with FEP Insulation
  • Typical DC Resistance (9m): Approx. 5.9 Ω ±0.5
  • Target Material: Ferrous Steel (Recommended)
  • Linear Measuring Range: 2.0 mm (80 mils) typical
  • System Sensitivity: 200 mV/mil (7.87 V/mm)
  • Frequency Response: 0 to 10,000 Hz (Flat within ±3%)
  • Operating Temp Range: -51°C to +177°C (-60°F to +351°F)
  • Seal Material: Viton O-ring (Not pressure tested)
  • Case Torque (Rec.): 15.2 N·m | Max: 45.2 N·m

Installation & Application Guidelines

  • Install the probe using the recommended torque of 15.2 N·m on the case.
  • Do not exceed the maximum thread engagement length of 0.938 inches.
  • Hand-tighten the connector; the maximum torque is 0.565 N·m (5 in-lb).
  • Maintain a minimum bend radius of 1.0 inch (25.4 mm) for the cable.
  • For long-term reliability, avoid operating below -34°C (-29°F).
  • This 3300 XL probe is ideal for turbines, pumps, fans, and compressors.

Technical FAQ for System Integrators

  • Q: What is the maximum cable length for reliable signal integrity? A: The system is designed for up to 9 meters; longer runs may require calibration.
  • Q: Can this probe measure non-ferrous or coated targets? A: Yes, but sensitivity and linear range will change; consult factory for setup.
  • Q: Does the standard cable differ from FluidLoc in harsh environments? A: Yes, for wet/oily areas, specify a FluidLoc cable option for better protection.
  • Q: What is the expected mechanical resolution of this probe? A: The system typically achieves a resolution better than 0.1 mils (2.5 µm).
  • Q: Is special termination required for the 75 Ω triaxial cable? A: Yes, it must connect to a compatible Bently Nevada driver or monitoring system.

© 2026 Ubest Automation Limited. https://www.ubestplc.com/ All rights reserved.
Contact: sales@ubestplc.com Phone: +86 180 3000 5825