Bently Nevada 330130-070-11-05 - Extension Cable

In stock
Manufacturer:
Bently Nevada
Product No.:
330130-070-11-05
Condition:
In Stock
Product Type:
Extension Cable
Product Origin:
USA
Weight:
721g
Shipping port:
Xiamen
Warranty:
12 months

UBEST – Trusted Global Automation Parts Supplier

We offer a wide range of in-stock industrial automation spare parts. All products come with a 12-month warranty and a 30-day refund for quality issues.

About Us | Contact

Overview

The Bently Nevada 330130-070-11-05 Extension Cable is a high-performance solution designed for use with the 3300 XL 8 mm Proximitor Sensor and associated equipment. Manufactured in the U.S.A., it ensures robust connections for industrial machinery monitoring. The cable includes an armored FluidLoc option to prevent leaks from turbine oils and other fluids.

Key Features:

  • Length Option: 7.0 meters (22.9 feet)
  • Cable Type: Armored FluidLoc cable, suitable for harsh environments
  • Connector Protector: Includes silicone tape for alternative protection (not recommended for turbine oil exposure)
  • Weight:
    • Armored Extension Cable: 0.721 kg (103 g/m)
  • Approvals: CSA, ATEX, IECEx certified for safety

Technical Specifications:

  • Cable Resistance:
    • Center-to-Center Conductor: 1.54 ± 0.23 Ω (7.0 m)
    • Outer Conductor-to-Conductor: 0.46 ± 0.09 Ω (7.0 m)
  • Capacitance: 69.9 pF/m (21.3 pF/ft)
  • Output Resistance: 50 Ω
  • Voltage Requirement: -17.5 Vdc to -26 Vdc (non-incendive circuits), -23 Vdc to -26 Vdc (with barriers)
  • Supply Sensitivity: Less than 2 mV per volt change in input voltage
  • Linear Range: From 0.25 mm to 2.3 mm (10 to 90 mils)

Advantages:

  • Improved Durability: The extension cable utilizes the patented TipLoc molding method for stronger bonding and the CableLoc design, offering 330 N (75 lbf) pull strength.
  • Leak Prevention: The FluidLoc option ensures that liquids do not leak through the cable, enhancing system integrity in industrial applications.
  • Silicone Tape Option: A flexible solution to protect connections, though not ideal for oil-exposed areas.