Bently Nevada 9-Meter Proximity Probe with FluidLoc Protection
Extend your monitoring capabilities with the Bently Nevada 330707-00-24-90-12-00. This sensor features an extra-long 9-meter FluidLoc cable. It is perfect for large machinery or remote installation points. The probe has a robust 304 stainless steel body. Its tip is made from durable PPS plastic. The FluidLoc cable resists moisture and liquid wicking. This model is for general industrial use without special certifications. Achieve reliable vibration data over long distances.
Part Number Structure: 330707-00-24-90-12-00
-
Product Identifier [330707]:
- Platform: 3300 XL Monitoring System.
- Type: 11mm Proximity Displacement Probe.
- Mounting: 5/8-18 UNF Thread, No Armor.
- Specification -00: Unthreaded Shank = 0.0 inch.
- Specification -24: Case OAL = 2.4 inches.
- Specification -90: Attached Cable = 9.0 meters (29.5 ft).
- Specification -12: Interface = ClickLoc Connector & FluidLoc Cable.
- Specification -00: Approvals = Not Required for This Model.
Complete Technical Data Sheet
- Manufacturer & Part No: Bently Nevada 330707-00-24-90-12-00
- System Family: 3300 XL Vibration Analysis
- Sensing Technology: Non-Contact Eddy Current
- Active Area Diameter: 11.0 mm (0.433 in)
- Housing Construction: Machined AISI 304 SST
- Tip Construction: High-Performance PPS Polymer
- Cable Electrical Rating: 75 Ohm Triaxial
- Cable Key Feature: FluidLoc Moisture-Wick Barrier
- Cable Insulation: FEP (Fluorinated Ethylene Propylene)
- Total Extended Length: 9.0 Meters (29.5 Feet)
- DC Probe Resistance (9m): 8.5 Ohms
- Resistance Tolerance: ± 1.1 Ohms (7.4 to 9.6 Ω)
- Standard Thread: 5/8-18 UNF
- Compatible Metric Thread 1: M16 x 1.5 mm
- Compatible Metric Thread 2: M14 x 1.5 mm
- Maximum Engagement (5/8-18): 0.938 Inch (23.8 mm)
- Optimal Mounting Torque: 15.2 N·m (133 in-lb)
- Torque Never Exceed: 45.2 N·m (400 in-lb)
- Electrical Connector: ClickLock Coaxial Style
- Connector Installation: Hand Tight Only
- Minimum Bend Radius: 25.4 mm (1.0 inch)
- Full Operating Range: -51°C to +177°C
- Environmental Seal: Factory-Fitted Viton O-Ring
- Pre-Installation Advisory: Do not handle below -34°C (-29°F)
- Unit Shipping Mass: 0.17 kg (0.37 lbs)
Installation & Handling Guide
- This 9-meter probe requires a matching 9-meter Proximitor sensor.
- Carefully plan the long cable route to avoid damage.
- Use large, loose loops for any excess cable. Avoid tight coiling.
- Ensure the mounting hole is clean and threads are in good condition.
- Hand-start the probe, then torque to 15.2 N·m with a wrench.
- Push the ClickLoc connector straight in until it locks audibly.
- Protect the cable from sharp edges and extreme heat sources.
- Allow the probe to warm to above -34°C before installation if cold.
Compatibility Notes
The Bently Nevada 330707 probe with 9m cable is designed for 3300 XL systems. It must be paired with a Proximitor sensor that also has a 9-meter cable length for proper system calibration.
Our Warranty Promise
We stand behind this product with a full 12-month warranty. This covers any material or workmanship defects for one year from your purchase date.
Global Shipping Options
We deliver worldwide quickly and reliably. We partner with FedEx, UPS, and DHL to offer flexible shipping solutions for every order.
Technical FAQs
What is the primary use case for a 9-meter cable?
It is for monitoring points far from the control panel, such as on large turbines, generators, or across big machine halls where shorter cables cannot reach.
Does the FluidLoc feature work with the 9-meter length?
Yes. The FluidLoc moisture barrier is integrated along the entire 9-meter cable length, providing consistent protection.
Why is the resistance value higher than shorter probes?
Longer cables have more inherent electrical resistance. The 8.5-ohm value is normal and accounted for in the system design with a matching 9-meter proximitor.
Can I field-repair the FluidLoc cable if damaged?
No. The cable and probe are a sealed, calibrated unit. Damage to the cable requires replacement of the entire 330707-00-24-90-12-00 assembly.
How do I ensure signal integrity over 9 meters?
Use the correctly matched 9-meter proximitor, ensure all connections are clean and tight, and route the cable away from sources of strong electrical noise.
© 2025 Ubest Automation Limited. All rights reserved.
Original Source: https://www.ubestplc.com/
Contact: sales@ubestplc.com | Phone: +86 180 3000 5825