{"product_id":"buy-honeywell-xnx-amav-nnnnn-transmitter-request-quote","title":"Buy Honeywell XNX-AMAV-NNNNN Transmitter - Request Quote","description":"\u003ch2\u003e\u003cb\u003eHoneywell XNX-AMAV-NNNNN Universal Gas Transmitter\u003c\/b\u003e\u003c\/h2\u003e\n\n\u003cp\u003eThe \u003cb\u003eHoneywell XNX-AMAV-NNNNN\u003c\/b\u003e transmitter delivers reliable toxic and flammable gas monitoring across challenging industrial applications. Process engineers install this versatile device to protect workforce personnel from sudden hazardous chemical releases.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cb\u003eSummary\u003c\/b\u003e\u003c\/h3\u003e\n\n\u003cp\u003eThe \u003cb\u003eXNX-AMAV-NNNNN\u003c\/b\u003e unit serves as a universal field monitoring gateway for industrial gas detection systems. This advanced device processes inputs from high-precision milli-Volt sensors and broadcasts signal data to main plant control networks. The rugged painted aluminum enclosure shields internal electronic circuits against severe offshore salt spray and harsh outdoor conditions.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cb\u003eModel Code Structure Breakdown\u003c\/b\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n  \u003cli\u003e\n\u003cb\u003eXNX-AMAV-NNNNN\u003c\/b\u003e (XNX Universal Transmitter Platform)\n    \u003cul\u003e\n      \u003cli\u003e— Approval Standard: \u003cspan style=\"color: #2b78e4;\"\u003e\u003cb\u003eA = ATEX\/IECEx Hazardous Area Standard\u003c\/b\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n      \u003cli\u003e— Cable Entry Type: \u003cspan style=\"color: #2b78e4;\"\u003e\u003cb\u003eM = M25 Threaded Cable Entries\u003c\/b\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n      \u003cli\u003e— Enclosure Material: \u003cspan style=\"color: #2b78e4;\"\u003e\u003cb\u003eA = Painted Marine Grade Aluminum Housing\u003c\/b\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n      \u003cli\u003e— Sensor Interface Personality: \u003cspan style=\"color: #2b78e4;\"\u003e\u003cb\u003eV = Milli-Volt (mV) Input Board for MPD and Sensepoint Sensors\u003c\/b\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n      \u003cli\u003e— System Option: N = No Additional Option Installed\u003c\/li\u003e\n      \u003cli\u003e— Local HART Option: N = Standard Non-HART Port Configuration\u003c\/li\u003e\n      \u003cli\u003e— Integrated Sensor Assembly: NNN = Base Transmitter Body Supplied Without Attached Sensor\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cb\u003eKey Selling Points\u003c\/b\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n  \u003cli\u003eUniversal architecture supports catalytic bead, electrochemical, and optical infrared sensor technologies on one standard platform.\u003c\/li\u003e\n  \u003cli\u003eHART EDDL software support gives operators direct diagnostic access to monitor field sensor health metrics instantly.\u003c\/li\u003e\n  \u003cli\u003eHeavy-duty IP66 aluminum construction protects inner electronics from weather moisture and aggressive chemical dust exposure.\u003c\/li\u003e\n  \u003cli\u003eBacklit custom LCD display presents current gas concentration numbers, operating status, and calibration prompts clearly.\u003c\/li\u003e\n  \u003cli\u003eFlexible signal output configuration interfaces seamlessly with central safety PLCs and distributed control system nodes.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cb\u003eComplete Technical Specifications\u003c\/b\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n  \u003cli\u003e\n\u003cb\u003eBrand Name:\u003c\/b\u003e Honeywell\u003c\/li\u003e\n  \u003cli\u003e\n\u003cb\u003eModel Code:\u003c\/b\u003e \u003cb\u003eXNX-AMAV-NNNNN\u003c\/b\u003e\n\u003c\/li\u003e\n  \u003cli\u003e\n\u003cb\u003eMeasurement Scale Range:\u003c\/b\u003e Configurable scaling range covering 0 to 100% LEL or variable parts-per-million detection levels.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cb\u003eFrequency Response Speed:\u003c\/b\u003e Dynamic signal sample rate updating target gas field readings every single second.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cb\u003eDetection Sensitivity:\u003c\/b\u003e High baseline measurement sensitivity resolving tiny concentration variations down to 1% LEL steps.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cb\u003eSignal Output Linearity:\u003c\/b\u003e Linear current output response maintaining precise proportional signal tracking across full target range.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cb\u003eDisplay Resolution:\u003c\/b\u003e High visual LCD resolution displaying clear digital gas levels and system diagnostic fault icons.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cb\u003eOperating Temperature Range:\u003c\/b\u003e Sturdy industrial temperature tolerance maintaining continuous monitoring performance between \u003cspan style=\"color: #2b78e4;\"\u003e\u003cb\u003e-40°C and +65°C\u003c\/b\u003e\u003c\/span\u003e.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cb\u003eEnvironmental Ingress Rating:\u003c\/b\u003e Sealed housing construction meeting tough \u003cspan style=\"color: #2b78e4;\"\u003e\u003cb\u003eIP66 and NEMA 4X ingress protection standards\u003c\/b\u003e\u003c\/span\u003e.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cb\u003eInterference Shielding Capacity:\u003c\/b\u003e Internal electronic filters eliminate severe electromagnetic radiation noise and radio frequency interference signals.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cb\u003eEngineering Installation Guide\u003c\/b\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n  \u003cli\u003eMount the transmitter main housing securely onto a solid wall structure or vertical support pipe bracket.\u003c\/li\u003e\n  \u003cli\u003eRun approved field power wiring through the M25 cable entry points using certified explosion-proof cable glands.\u003c\/li\u003e\n  \u003cli\u003eConnect the milli-Volt sensor cable leads firmly to the designated internal terminal block connector pins correctly.\u003c\/li\u003e\n  \u003cli\u003eVerify total grounding wire connection between the aluminum transmitter housing frame and central plant earth ground.\u003c\/li\u003e\n  \u003cli\u003eCalibrate the sensor optical baseline zero and target span settings using magnetic wand controls on front glass.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cb\u003eStandard Package Contents\u003c\/b\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n  \u003cli\u003eOne main transmitter unit housed inside a painted marine-grade aluminum hazardous area enclosure body.\u003c\/li\u003e\n  \u003cli\u003eOne magnetic calibration tool for navigating internal display menus without opening the flameproof housing enclosure.\u003c\/li\u003e\n  \u003cli\u003eOne internal terminal board assembly designed for quick milli-Volt sensor signal cable terminal block connection.\u003c\/li\u003e\n  \u003cli\u003eFast international express transport partners ship customer orders quickly via \u003cspan style=\"color: #2b78e4;\"\u003e\u003cb\u003eFedEx, UPS, and DHL air networks\u003c\/b\u003e\u003c\/span\u003e.\u003c\/li\u003e\n  \u003cli\u003eOur company backs every hardware order with an exclusive \u003cspan style=\"color: #2b78e4;\"\u003e\u003cb\u003e12-month quality warranty term\u003c\/b\u003e\u003c\/span\u003e for full peace of mind.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cb\u003eModel Selection Comparison and Engineering Advice\u003c\/b\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n  \u003cli\u003e\n\u003cb\u003eXNX-AMAV-NNNNN\u003c\/b\u003e vs \u003ca href=\"https:\/\/www.ubestplc.com\/products\/honeywell-xnx-amsv-mnnnn-universal-transmitter-get-a-quote-today\" target=\"_blank\"\u003eXNX-AMSV-MNNNN\u003c\/a\u003e Selection Analysis:\n    \u003cul\u003e\n      \u003cli\u003e— The \u003cb\u003eXNX-AMAV-NNNNN\u003c\/b\u003e configuration provides ATEX approval with M25 cable entries for European field installations.\u003c\/li\u003e\n      \u003cli\u003e— The \u003ca href=\"https:\/\/www.ubestplc.com\/products\/honeywell-xnx-amsv-mnnnn-universal-transmitter-get-a-quote-today\" target=\"_blank\"\u003eXNX-AMSV-MNNNN\u003c\/a\u003e unit offers 316 stainless steel housing construction for extreme offshore marine environments.\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/li\u003e\n  \u003cli\u003eEngineering Selection Tip: Choose painted aluminum bodies for onshore plants to save weight and reduce upfront costs. Select stainless steel bodies for offshore drilling rigs exposed to constant saltwater spray and high mechanical impacts.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cb\u003eFrequently Asked Questions\u003c\/b\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n  \u003cli\u003e\n\u003cb\u003eQuestion:\u003c\/b\u003e Which sensor types interface directly with this specific transmitter configuration?\u003c\/li\u003e\n  \u003cli\u003e\n\u003cb\u003eAnswer:\u003c\/b\u003e The \u003cb\u003eXNX-AMAV-NNNNN\u003c\/b\u003e model accepts milli-Volt signal inputs from Honeywell Sensepoint, MPD, and Model 705 sensors.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cb\u003eQuestion:\u003c\/b\u003e What exact hazardous area explosion approvals does this aluminum body possess?\u003c\/li\u003e\n  \u003cli\u003e\n\u003cb\u003eAnswer:\u003c\/b\u003e This unit carries certified ATEX and IECEx hazardous zone approvals for safe industrial field deployment.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cb\u003eQuestion:\u003c\/b\u003e Does this base transmitter model arrive with a gas sensor attached?\u003c\/li\u003e\n  \u003cli\u003e\n\u003cb\u003eAnswer:\u003c\/b\u003e The base package provides the standalone transmitter unit without an attached gas sensor module included.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cb\u003eQuestion:\u003c\/b\u003e Can field operators perform zero and span calibrations without opening the glass cover?\u003c\/li\u003e\n  \u003cli\u003e\n\u003cb\u003eAnswer:\u003c\/b\u003e Technicians use the included non-intrusive magnetic wand tool to navigate calibration menus through front glass safe.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cb\u003eQuestion:\u003c\/b\u003e What cable entry threading size does the aluminum enclosure housing feature?\u003c\/li\u003e\n  \u003cli\u003e\n\u003cb\u003eAnswer:\u003c\/b\u003e The aluminum enclosure features standard M25 metric threaded cable entries for heavy-duty field wiring glands.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cb\u003eTechnical Documentation Download\u003c\/b\u003e\u003c\/h3\u003e\n\n\u003cul\u003e\n  \u003cli\u003eAccess official installation drawings and operation manuals directly by downloading the \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/XNX_Universal_Transmitter.pdf?v=1787797330\" target=\"_blank\"\u003eHoneywell XNX Universal Transmitter Specification Manual\u003c\/a\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cb\u003e© 2026 Ubest Automation Limited. \u003ca href=\"https:\/\/www.ubestplc.com\/\" target=\"_blank\"\u003ehttps:\/\/www.ubestplc.com\/\u003c\/a\u003e All rights reserved.\u003c\/b\u003e\u003c\/p\u003e\n\n\u003cp\u003eContact: Email \u003ca href=\"mailto:sales@ubestplc.com\"\u003esales@ubestplc.com\u003c\/a\u003e Phone \u003ca href=\"https:\/\/wa.me\/8618030005825\" target=\"_blank\"\u003e+86 86 180 3000 5825\u003c\/a\u003e\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52785730388250,"sku":"XNX-AMAV-NNNNN","price":136.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/XNX-AMSE-NHNNN_2_d2cc37bc-5f56-4342-9571-0ccbe8d24594.jpg?v=1788415251","url":"https:\/\/www.ubestplc.com\/products\/buy-honeywell-xnx-amav-nnnnn-transmitter-request-quote","provider":"Ubest Automation Limited","version":"1.0","type":"link"}