{"product_id":"buy-honeywell-xnx-utav-nhnnn-gas-transmitter-get-instant-quote","title":"Buy Honeywell XNX-UTAV-NHNNN Gas Transmitter - Get Instant Quote","description":"\u003ch2\u003e\u003cstrong\u003eHoneywell XNX-UTAV-NHNNN Industrial Gas Detection Transmitter\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell XNX-UTAV-NHNNN\u003c\/strong\u003e gas detection transmitter delivers precise environmental monitoring across high-risk industrial facilities. Engineers design this \u003cstrong\u003eHoneywell\u003c\/strong\u003e XNX Universal Transmitter model to handle rugged environments while maintaining stable sensor signals.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eModel Number Breakdown\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHoneywell\u003c\/strong\u003e XNX Universal Transmitter Series\u003c\/li\u003e\n\u003cli\u003e└── \u003cstrong\u003eXNX-UTAV-NHNNN\u003c\/strong\u003e Part Number Configuration\n\u003cul\u003e\n\u003cli\u003e├── Approval: \u003cstrong\u003eU\u003c\/strong\u003e (UL \/ CSA Approved)\u003c\/li\u003e\n\u003cli\u003e├── Entry Type: \u003cstrong\u003eT\u003c\/strong\u003e (5 x 3\/4\" NPT Entries)\u003c\/li\u003e\n\u003cli\u003e├── Housing Material: \u003cstrong\u003eA\u003c\/strong\u003e (Painted Aluminum Alloy)\u003c\/li\u003e\n\u003cli\u003e├── Personality: \u003cstrong\u003eV\u003c\/strong\u003e (m-Volt Sensor Interface)\u003c\/li\u003e\n\u003cli\u003e├── Option: \u003cstrong\u003eN\u003c\/strong\u003e (No Optional Relays Installed)\u003c\/li\u003e\n\u003cli\u003e├── Local Interface: \u003cstrong\u003eH\u003c\/strong\u003e (Local HART Interface Included)\u003c\/li\u003e\n\u003cli\u003e└── Sensor Range: \u003cstrong\u003eNNN\u003c\/strong\u003e (No Integrated MPD Sensor Supplied)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBrand Name: \u003cstrong\u003eHoneywell\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eModel Number: \u003cstrong\u003eXNX-UTAV-NHNNN\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eEquipment Type: Industrial Gas Detection Transmitter\u003c\/li\u003e\n\u003cli\u003eProduct Series: XNX Universal Transmitters\u003c\/li\u003e\n\u003cli\u003eOperating Voltage: \u003cspan style=\"color: #0056b3;\"\u003e16 to 32 VDC\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003ePower Consumption: \u003cspan style=\"color: #0056b3;\"\u003e6.5 Watts Maximum\u003c\/span\u003e (mV Personality)\u003c\/li\u003e\n\u003cli\u003eOperating Temperature: \u003cspan style=\"color: #d9534f;\"\u003e-40°C to 65°C\u003c\/span\u003e (-40°F to 149°F)\u003c\/li\u003e\n\u003cli\u003eOperating Relative Humidity: \u003cspan style=\"color: #0056b3;\"\u003e0% to 99% RH\u003c\/span\u003e (Non-Condensing)\u003c\/li\u003e\n\u003cli\u003eSignal Output: 4-20 mA with HART Protocol (Sink, Source, or Isolated)\u003c\/li\u003e\n\u003cli\u003eOutput Signal Accuracy: \u003cspan style=\"color: #28a745;\"\u003e±1% of Full Scale\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eIngress Protection Rating: \u003cspan style=\"color: #28a745;\"\u003eIP66 and NEMA 4X Standards\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eCompatible Sensor Types: MPD, Sensepoint, and 705 Series m-Volt Sensors\u003c\/li\u003e\n\u003cli\u003eWiring Cable Entries: 5 x 3\/4\" NPT Threaded Connections\u003c\/li\u003e\n\u003cli\u003eLocal Display Interface: Integrated Local HART Connection Port\u003c\/li\u003e\n\u003cli\u003ePhysical Equipment Weight: 6.2 lbs (2.8 kg)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation Guidelines\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the transmitter chassis to a flat vertical surface using integral mounting lugs.\u003c\/li\u003e\n\u003cli\u003eSecure optional pipe or ceiling mounting kits when installing unit on structural steel.\u003c\/li\u003e\n\u003cli\u003eKeep wiring distance within recommended engineering limits to prevent voltage drop across terminals.\u003c\/li\u003e\n\u003cli\u003eRun external field cables through the five 3\/4\" NPT conduit entries securely.\u003c\/li\u003e\n\u003cli\u003eSeal all unused threaded entry ports with approved explosion-proof conduit plugs.\u003c\/li\u003e\n\u003cli\u003eConnect external m-Volt sensors to designated internal terminal blocks following wiring schematics.\u003c\/li\u003e\n\u003cli\u003eSelect desired loop configuration (sink, source, or isolated) via internal junction board jumpers.\u003c\/li\u003e\n\u003cli\u003eVerify input voltage remains strictly between 16 VDC and 32 VDC before applying power.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eShipping Packaging List\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMain \u003cstrong\u003eHoneywell XNX-UTAV-NHNNN\u003c\/strong\u003e transmitter enclosure assembly with internal HART module.\u003c\/li\u003e\n\u003cli\u003eHeavy-duty protective foam inserts engineered for safe international freight transit.\u003c\/li\u003e\n\u003cli\u003eExpress global shipping carriers include FedEx, UPS, and DHL standard air services.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eWhat sensors connect to this specific transmitter model?\n\u003cul\u003e\n\u003cli\u003eThe unit interfaces with standard MPD, Sensepoint, and 705 Series m-Volt gas sensors.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eDoes this unit include internal relay switches or options?\n\u003cul\u003e\n\u003cli\u003eNo, the \u003cstrong\u003eXNX-UTAV-NHNNN\u003c\/strong\u003e configuration relies strictly on standard 4-20mA HART output wiring.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eWhat mounting options can technicians use during site installation?\n\u003cul\u003e\n\u003cli\u003ePersonnel can install the unit directly using surface lugs or optional pipe brackets.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eHow does the enclosure withstand harsh outdoor industrial weather?\n\u003cul\u003e\n\u003cli\u003eThe painted aluminum alloy housing carries full IP66 and NEMA 4X ingress ratings.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eSummary\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe \u003cstrong\u003eHoneywell XNX-UTAV-NHNNN\u003c\/strong\u003e transmitter provides flexible signal conditioning for millivolt industrial gas sensors.\u003c\/li\u003e\n\u003cli\u003eHigh accuracy ratings of \u003cspan style=\"color: #28a745;\"\u003e±1% full scale\u003c\/span\u003e guarantee dependable monitoring for hazardous field sites.\u003c\/li\u003e\n\u003cli\u003eRobust aluminum construction protects internal circuitry across extreme temperature and humidity conditions.\u003c\/li\u003e\n\u003cli\u003eIndustrial facilities rely on this unit for dependable 4-20mA HART gas detection infrastructure.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e© 2026 Ubest Automation Limited. \u003ca href=\"https:\/\/www.ubestplc.com\/\"\u003ehttps:\/\/www.ubestplc.com\/\u003c\/a\u003e All rights reserved.\u003c\/strong\u003e\u003cbr\u003eContact: Email \u003ca href=\"mailto:sales@ubestplc.com\"\u003esales@ubestplc.com\u003c\/a\u003e Phone \u003ca href=\"https:\/\/wa.me\/8618030005825\"\u003e+86 86 180 3000 5825\u003c\/a\u003e\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52745772695834,"sku":"XNX-UTAV-NHNNN","price":25.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/XNX-AMSE-NNNNN_6_44bcab05-f5b7-445c-8640-31d78c6d7fd7.jpg?v=1787797566","url":"https:\/\/www.ubestplc.com\/products\/buy-honeywell-xnx-utav-nhnnn-gas-transmitter-get-instant-quote","provider":"Ubest Automation Limited","version":"1.0","type":"link"}