{"product_id":"buy-honeywell-xnx-utse-fnic1-transmitter-specs-inquiry","title":"Buy Honeywell XNX-UTSE-FNIC1 Transmitter Specs \u0026 Inquiry","description":"\u003ch2\u003e\u003cstrong\u003eHoneywell XNX-UTSE-FNIC1 Universal Gas Transmitter Overview\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell\u003c\/strong\u003e \u003cstrong\u003eXNX-UTSE-FNIC1\u003c\/strong\u003e universal gas transmitter delivers exceptional performance for industrial safety monitoring applications.\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eEngineers select this robust device for precise infrared carbon dioxide detection in hazardous plant environments.\u003c\/li\u003e\n  \u003cli\u003eThe system utilizes a modular platform to integrate seamlessly with various digital control architectures.\u003c\/li\u003e\n  \u003cli\u003eOperational reliability remains exceptionally high during continuous plant processes and harsh weather conditions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications and Parameters\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eBrand: \u003cstrong\u003eHoneywell\u003c\/strong\u003e | Model: \u003cstrong\u003eXNX-UTSE-FNIC1\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eMeasurement Range: 0 to 5 percent volume carbon dioxide (\u003cspan style=\"font-style:italic; font-weight:bold;\"\u003e0-5%Vol\u003c\/span\u003e IR \u003cspan style=\"font-style:italic; font-weight:bold;\"\u003eCO\u003csub\u003e2\u003c\/sub\u003e\u003c\/span\u003e)\u003c\/li\u003e\n  \u003cli\u003eEnclosure Material: Marine-grade 316 stainless steel for maximum corrosion resistance\u003c\/li\u003e\n  \u003cli\u003eConduit Entry Type: Three-quarter inch National Pipe Thread (\u003cspan style=\"font-style:italic; font-weight:bold;\"\u003e3\/4\"\u003c\/span\u003e NPT) connections\u003c\/li\u003e\n  \u003cli\u003eOutput Protocol: Foundation Fieldbus communication option with no local HART protocol enabled\u003c\/li\u003e\n  \u003cli\u003eCertification Standards: UL and CSA hazardous location approvals\u003c\/li\u003e\n  \u003cli\u003eTransmitter Weight: Approximately 6.8 kilograms (15 lbs) total unit mass\u003c\/li\u003e\n  \u003cli\u003eOperating Temperature: Minus 40 degrees Celsius to plus 65 degrees Celsius range\u003c\/li\u003e\n  \u003cli\u003eEnvironmental Tolerance: Up to 99 percent relative humidity with non-condensing protection\u003c\/li\u003e\n  \u003cli\u003ePower Requirements: Nominal 24 volts direct current operational input\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eInstallation Guidelines\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eTechnicians mount the transmitter securely onto walls or vertical pipes using integral mounting lugs.\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eField wiring requires proper sizing to minimize voltage drops across long signal cable runs.\u003c\/li\u003e\n  \u003cli\u003eInstall approved seal fittings within eighteen inches of the enclosure to maintain explosion-proof integrity.\u003c\/li\u003e\n  \u003cli\u003eGround the stainless steel housing properly to eliminate radio frequency interference and electrical noise.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eStandard Package Contents\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003ePackage includes essential components for immediate site deployment.\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHoneywell\u003c\/strong\u003e \u003cstrong\u003eXNX-UTSE-FNIC1\u003c\/strong\u003e main transmitter housing assembly\u003c\/li\u003e\n  \u003cli\u003eInfrared carbon dioxide sensor cartridge calibrated for 0-5%Vol detection\u003c\/li\u003e\n  \u003cli\u003eIntegrated intrinsic safety barrier and plug-in adaptor module\u003c\/li\u003e\n  \u003cli\u003eQuick start installation reference documentation and hardware kit\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eLogistics and Shipping Methods\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eGlobal logistics partners ensure prompt dispatch to international industrial destinations.\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eExpedited international delivery utilizes trusted global couriers including FedEx, UPS, and DHL.\u003c\/li\u003e\n  \u003cli\u003eSecure industrial packaging protects internal electronic components during transit to international project sites.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eCommon technical inquiries regarding operational setup and deployment.\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eWhat primary sensor technology does the \u003cstrong\u003eXNX-UTSE-FNIC1\u003c\/strong\u003e utilize for gas detection? The unit incorporates an infrared sensor specifically designed for accurate carbon dioxide monitoring.\u003c\/li\u003e\n  \u003cli\u003eCan technicians perform sensor maintenance without opening the explosion-proof housing? Operators utilize non-intrusive magnetic wand operations to configure parameters safely in hazardous areas.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eModel Comparison and Technical Recommendation\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eTechnical comparison assists engineers in selecting appropriate variants for site requirements.\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eTechnicians evaluating alternative configurations often review the \u003ca href=\"https:\/\/www.ubestplc.com\/products\/honeywell-xnx-utse-fncb1-transmitter-gas-detector\" target=\"_blank\" rel=\"noopener\"\u003eHoneywell XNX-UTSE-FNCB1 Transmitter Gas Detector\u003c\/a\u003e for specific combustible gas applications.\u003c\/li\u003e\n  \u003cli\u003eEngineers recommend selecting the \u003cstrong\u003eXNX-UTSE-FNIC1\u003c\/strong\u003e when plant control networks specifically require Foundation Fieldbus integration combined with carbon dioxide infrared sensing capabilities.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003ePlease download the complete technical reference manual via the \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/XNX_Universal_Transmitter.pdf?v=1787797330\" target=\"_blank\" rel=\"noopener\"\u003eXNX Universal Transmitter PDF Guide\u003c\/a\u003e.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003e© 2026 Ubest Automation Limited. \u003ca href=\"https:\/\/www.ubestplc.com\/\" target=\"_blank\" rel=\"noopener\"\u003ehttps:\/\/www.ubestplc.com\/\u003c\/a\u003e All rights reserved.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eContact: Email \u003ca href=\"mailto:sales@ubestplc.com\"\u003esales@ubestplc.com\u003c\/a\u003e Phone \u003ca href=\"https:\/\/wa.me\/8618030005825\"\u003e+86 180 3000 5825\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52770502803738,"sku":"XNX-UTSE-FNIC1","price":203.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/XNX-AMSE-NHNNN_4_5d8dbd94-9d60-4604-9745-86cec32f8b62.jpg?v=1788140719","url":"https:\/\/www.ubestplc.com\/products\/buy-honeywell-xnx-utse-fnic1-transmitter-specs-inquiry","provider":"Ubest Automation Limited","version":"1.0","type":"link"}