{"product_id":"buy-honeywell-xnx-utse-rnic1-co2-transmitter-get-a-fast-quote","title":"Buy Honeywell XNX-UTSE-RNIC1 CO2 Transmitter | Get a Fast Quote","description":"\u003ch2\u003e\u003cb\u003eHoneywell XNX-UTSE-RNIC1 Gas Transmitter Technical Guide\u003c\/b\u003e\u003c\/h2\u003e\n\n\u003cp\u003eEngineers design the \u003cb\u003eHoneywell\u003c\/b\u003e \u003cb\u003eXNX-UTSE-RNIC1\u003c\/b\u003e universal gas transmitter for demanding industrial hazardous locations that require accurate carbon dioxide detection. The \u003cb\u003eXNX-UTSE-RNIC1\u003c\/b\u003e transmitter processes infrared sensor signals efficiently and drives local alarm outputs through integrated relays to ensure fast plant safety responses.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cb\u003eProduct Summary\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eThis transmitter features a rugged \u003cspan style=\"color: #0056b3;\"\u003e316 stainless steel housing\u003c\/span\u003e with severe weather protection.\u003c\/li\u003e\n  \u003cli\u003eThe internal electrochemical cartridge interface supports reliable infrared carbon dioxide monitoring from \u003cspan style=\"color: #0056b3;\"\u003e0 to 5% Vol\u003c\/span\u003e.\u003c\/li\u003e\n  \u003cli\u003eIntegrated alarm and fault relays provide direct local control capabilities without requiring extra control hardware.\u003c\/li\u003e\n  \u003cli\u003eExplosion-proof approvals allow seamless installation in hazardous industrial environments across North America.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cb\u003eModel Code Tree Structure\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eXNX Series: Universal Gas Transmitter Platform\n    \u003cul\u003e\n      \u003cli\u003eApproval: U = UL\/CSA Certified\n        \u003cul\u003e\n          \u003cli\u003eEntry Type: T = 3\/4\" NPT Threaded Conduit\n            \u003cul\u003e\n              \u003cli\u003eMaterial: S = \u003cspan style=\"color: #0056b3;\"\u003e316 Stainless Steel\u003c\/span\u003e Construction\n                \u003cul\u003e\n                  \u003cli\u003ePersonality: E = Interface for Electrochemical\/IR Cartridges\n                    \u003cul\u003e\n                      \u003cli\u003eOption: R = Relay Board Option Included\n                        \u003cul\u003e\n                          \u003cli\u003eLocal HART: N = No Local HART Interface\n                            \u003cul\u003e\n                              \u003cli\u003eSensor Range: IC1 = IR Carbon Dioxide (0 to 5% Vol)\u003c\/li\u003e\n                            \u003c\/ul\u003e\n                          \u003c\/li\u003e\n                        \u003c\/ul\u003e\n                      \u003c\/li\u003e\n                    \u003c\/ul\u003e\n                  \u003c\/li\u003e\n                \u003c\/ul\u003e\n              \u003c\/li\u003e\n            \u003c\/ul\u003e\n          \u003c\/li\u003e\n        \u003c\/ul\u003e\n      \u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cb\u003eTechnical Specifications Matrix\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cb\u003eBrand:\u003c\/b\u003e Honeywell\u003c\/li\u003e\n  \u003cli\u003e\n\u003cb\u003eModel:\u003c\/b\u003e \u003cb\u003eXNX-UTSE-RNIC1\u003c\/b\u003e\n\u003c\/li\u003e\n  \u003cli\u003e\n\u003cb\u003eProduct Type:\u003c\/b\u003e Universal Gas Transmitter Assembly\u003c\/li\u003e\n  \u003cli\u003e\n\u003cb\u003eGas Type:\u003c\/b\u003e Carbon Dioxide (CO2)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cb\u003eTarget Sensor Technology:\u003c\/b\u003e Infrared (IR) Absorption\u003c\/li\u003e\n  \u003cli\u003e\n\u003cb\u003eMeasurement Range:\u003c\/b\u003e \u003cspan style=\"color: #0056b3;\"\u003e0 to 5% Vol\u003c\/span\u003e\n\u003c\/li\u003e\n  \u003cli\u003e\n\u003cb\u003eEnclosure Material:\u003c\/b\u003e 316 Stainless Steel\u003c\/li\u003e\n  \u003cli\u003e\n\u003cb\u003eConduit Entry:\u003c\/b\u003e Dual 3\/4\" NPT Openings\u003c\/li\u003e\n  \u003cli\u003e\n\u003cb\u003eOperating Temperature Range:\u003c\/b\u003e -40°C to +65°C (-40°F to +149°F)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cb\u003eResponse Time:\u003c\/b\u003e T90 \u0026lt; 30 seconds for standard target gas exposure\u003c\/li\u003e\n  \u003cli\u003e\n\u003cb\u003eLinearity:\u003c\/b\u003e ±2% of full-scale reading at ambient conditions\u003c\/li\u003e\n  \u003cli\u003e\n\u003cb\u003eSensitivity:\u003c\/b\u003e ±1% of full scale under stable working temperatures\u003c\/li\u003e\n  \u003cli\u003e\n\u003cb\u003eRelay Outputs:\u003c\/b\u003e 3 configurable SPDT relays (Alarm 1, Alarm 2, Fault)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cb\u003eHazardous Approvals:\u003c\/b\u003e UL\/CSA Class I, Div 1, Groups B, C, D\u003c\/li\u003e\n  \u003cli\u003e\n\u003cb\u003eUnit Weight:\u003c\/b\u003e \u003cspan style=\"color: #0056b3;\"\u003e6.8 kg (15 lbs)\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cb\u003eInstallation and Wiring Guidelines\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eMount the heavy unit securely to structural steel framing using proper mounting hardware.\u003c\/li\u003e\n  \u003cli\u003eSeal all 3\/4\" NPT conduit entries using approved explosion-proof fittings to maintain enclosure integrity.\u003c\/li\u003e\n  \u003cli\u003eConnect power and signal cables according to standard industrial safety practices and wire diagrams.\u003c\/li\u003e\n  \u003cli\u003eVerify relay terminal contacts before connecting external control sirens or safety shutdown devices.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cb\u003ePackaging and Express Shipping\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eFactory original packaging protects the heavy unit from drop impacts during long international transit.\u003c\/li\u003e\n  \u003cli\u003eInner custom foam inserts isolate sensitive electronic boards and sensor hardware from mechanical vibration.\u003c\/li\u003e\n  \u003cli\u003eWe ship orders worldwide via standard express networks including \u003cspan style=\"color: #0056b3;\"\u003eFedEx, UPS, and DHL\u003c\/span\u003e.\u003c\/li\u003e\n  \u003cli\u003eDispatch tracking numbers allow real-time monitoring of your package delivery progress online.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cb\u003eFrequently Asked Questions\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cb\u003eDoes this transmitter include local HART communications?\u003c\/b\u003e No, this specific model variant features no local HART connection terminal.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cb\u003eWhat housing material does this model use?\u003c\/b\u003e The main body uses heavy-duty 316 stainless steel for maximum corrosion resistance.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cb\u003eCan I connect external alarms directly to this unit?\u003c\/b\u003e Yes, the integrated internal relay board drives external alarm devices directly.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cb\u003e© 2026 Ubest Automation Limited. \u003ca href=\"https:\/\/www.ubestplc.com\/\" target=\"_blank\"\u003ehttps:\/\/www.ubestplc.com\/\u003c\/a\u003e All rights reserved.\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eContact: \u003ca href=\"mailto:sales@ubestplc.com\"\u003esales@ubestplc.com\u003c\/a\u003e | Phone: \u003ca href=\"https:\/\/wa.me\/8618030005825\" target=\"_blank\"\u003e+86 86 180 3000 5825\u003c\/a\u003e\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52779881627930,"sku":"XNX-UTSE-RNIC1","price":163.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/XNX-AMSE-NHNNN_6_a19a6415-c145-4d50-9ca3-ccd15830c905.jpg?v=1788318356","url":"https:\/\/www.ubestplc.com\/products\/buy-honeywell-xnx-utse-rnic1-co2-transmitter-get-a-fast-quote","provider":"Ubest Automation Limited","version":"1.0","type":"link"}