{"product_id":"drc1r5n-hach-sensor-kit-orp-probe-ad-1200-gateway","title":"DRC1R5N Hach Sensor Kit | ORP Probe AD 1200 Gateway","description":"\u003ch2\u003eHACH DRC1R5N Digital pH\/ORP Sensor Kit – Complete ORP Measurement System\u003c\/h2\u003e\n\u003ch3\u003eKey technical specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9e;\"\u003e\u003cstrong\u003eManufacturer \u0026amp; model:\u003c\/strong\u003e\u003c\/span\u003e HACH, \u003cstrong\u003eDRC1R5N\u003c\/strong\u003e digital pH\/ORP sensor kit\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9e;\"\u003e\u003cstrong\u003eMeasurement range:\u003c\/strong\u003e\u003c\/span\u003e -2000 mV to 2000 mV (ORP)\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9e;\"\u003e\u003cstrong\u003eAccuracy:\u003c\/strong\u003e\u003c\/span\u003e ±20 mV (limited by calibration solution accuracy)\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9e;\"\u003e\u003cstrong\u003eBody material:\u003c\/strong\u003e\u003c\/span\u003e PPS with platinum electrode\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9e;\"\u003e\u003cstrong\u003eOperating temperature:\u003c\/strong\u003e\u003c\/span\u003e 0 °C to 105 °C\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9e;\"\u003e\u003cstrong\u003ePressure range:\u003c\/strong\u003e\u003c\/span\u003e 0 to 6.9 bar at 100 °C (0‑100 psig at 212 °F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9e;\"\u003e\u003cstrong\u003eMaximum flow:\u003c\/strong\u003e\u003c\/span\u003e 0 to 2 m\/s\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9e;\"\u003e\u003cstrong\u003eSensor cable:\u003c\/strong\u003e\u003c\/span\u003e Integral coaxial with two conductors (temperature option); 4.5 m length\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9e;\"\u003e\u003cstrong\u003eIncluded cable:\u003c\/strong\u003e\u003c\/span\u003e 1 m digital extension cable\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9e;\"\u003e\u003cstrong\u003eMounting thread:\u003c\/strong\u003e\u003c\/span\u003e 0.75\" NPT\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9e;\"\u003e\u003cstrong\u003eWetted materials:\u003c\/strong\u003e\u003c\/span\u003e PPS, PTFE double junction, glass, platinum, FKM\/FPM O‑rings\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eKit contents \u0026amp; digital integration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eKit includes RC1R5N analog ORP sensor, AD 1200 Digital Gateway, and 1 m digital extension cable.\u003c\/li\u003e\n\u003cli\u003eDigital signal allows transmission up to 1000 m (3280 ft) with Hach Gateway or sc100 controller.\u003c\/li\u003e\n\u003cli\u003eBuilt‑in platinum electrode provides stable, linear response across full ORP range.\u003c\/li\u003e\n\u003cli\u003eExcellent noise immunity eliminates interference in industrial environments.\u003c\/li\u003e\n\u003cli\u003eThe \u003cstrong\u003eHACH DRC1R5N\u003c\/strong\u003e kit converts analog sensors to digital for modern control systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently asked questions (FAQ)\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat makes DRC1R5N different from DRC2K5N?\u003c\/strong\u003e The \u003cstrong\u003eDRC1R5N\u003c\/strong\u003e kit includes the AD 1200 Gateway and extension cable, while DRC2K5N is a standalone digital sensor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I use this sensor without the Gateway?\u003c\/strong\u003e No, the RC1R5N is an analog sensor; the AD 1200 Gateway converts it to digital for Hach controllers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the maximum distance from the controller?\u003c\/strong\u003e You can place the sensor up to 1000 m from a Hach Digital Gateway or sc100 controller.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIs temperature compensation included?\u003c\/strong\u003e No, this sensor has no built‑in temperature compensation; use optional conductors for external RTD.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat flow rate can this sensor handle?\u003c\/strong\u003e The maximum recommended flow is 2 m\/s to maintain measurement stability.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e© 2026 Ubest Automation Limited. \u003ca href=\"https:\/\/www.ubestplc.com\/\"\u003ehttps:\/\/www.ubestplc.com\/\u003c\/a\u003e All rights reserved.\u003c\/strong\u003e\u003cbr\u003eContact: \u003ca href=\"mailto:sales@ubestplc.com\"\u003esales@ubestplc.com\u003c\/a\u003e | Phone: \u003ca href=\"https:\/\/wa.me\/8618030005825\"\u003e+86 180 3000 5825\u003c\/a\u003e\u003c\/p\u003e","brand":"Hach","offers":[{"title":"Default Title","offer_id":51850157326618,"sku":"DRC1R5N","price":236.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/DRC1R5N-1.jpg?v=1773975775","url":"https:\/\/www.ubestplc.com\/products\/drc1r5n-hach-sensor-kit-orp-probe-ad-1200-gateway","provider":"Ubest Automation Limited","version":"1.0","type":"link"}