{"product_id":"ep202-b00-en00-emerson-digital-servo-drive-ac-dc","title":"EP202-B00-EN00 Emerson Digital Servo Drive | AC DC","description":"\u003ch2\u003e\u003cstrong\u003eEP202-B00-EN00 Digital Servo Drive: Flexible Power for Demanding Motion Control\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Technical Specifications – Power \u0026amp; Efficiency\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand \u0026amp; Model:\u003c\/strong\u003e \u003cstrong\u003eEmerson EP202-B00-EN00\u003c\/strong\u003e digital servo drive.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC Power Input:\u003c\/strong\u003e \u003cstrong style=\"color: #0066cc;\"\u003e20 Vac to 264 Vac\u003c\/strong\u003e, single phase, 47-63 Hz.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDC Power Input:\u003c\/strong\u003e \u003cstrong style=\"color: #0066cc;\"\u003e10 Vdc to 340 Vdc\u003c\/strong\u003e – great for battery or DC bus applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitching Frequency:\u003c\/strong\u003e \u003cstrong\u003e10 kHz\u003c\/strong\u003e for smooth motor control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEfficiency (AC Power):\u003c\/strong\u003e \u003cstrong style=\"color: #0066cc;\"\u003e95%\u003c\/strong\u003e at full rated output power.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply Output:\u003c\/strong\u003e \u003cstrong\u003e5 Vdc, 250 mA max\u003c\/strong\u003e for powering a master encoder.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIngress Protection (IP):\u003c\/strong\u003e Drive = \u003cstrong\u003eIP20\u003c\/strong\u003e. NT motors = IP65\/IP54. Molded cables = IP65.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eCommunication Interfaces – Multiple Protocol Support\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSerial Interface (RS-485):\u003c\/strong\u003e Modbus protocol with 32-bit data extension. Baud rates: \u003cstrong\u003e19.2k (default) or 9600\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEtherNet Interface (EP-P Models):\u003c\/strong\u003e \u003cstrong style=\"color: #0066cc;\"\u003e10\/100 M baud\u003c\/strong\u003e, auto-negotiated. Supports EtherNet\/IP, Modbus TCP\/IP, HTTP, and SMSC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDeviceNet Interface (EP-DN Models):\u003c\/strong\u003e Baud rates \u003cstrong\u003e125K, 250K, 500K\u003c\/strong\u003e. Draws max 25 mA from network.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eControl Inputs – Analog \u0026amp; Digital\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAnalog Command Input:\u003c\/strong\u003e \u003cstrong style=\"color: #0066cc;\"\u003e±10 Vdc, 14-bit resolution\u003c\/strong\u003e, 100k ohm impedance, differential. Absolute max input ±14 Vdc.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDigital Inputs:\u003c\/strong\u003e 5 inputs on EP-B models (16 on EP-I and EP-P). Accept \u003cstrong\u003e10-30 Vdc\u003c\/strong\u003e, 4.8k ohm impedance. Opto-isolated. Max response time \u003cstrong\u003e500 µs\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Debounce:\u003c\/strong\u003e Configurable \u003cstrong\u003e0-2000 ms\u003c\/strong\u003e via PowerTools Pro software.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eControl Outputs – Diagnostics \u0026amp; Digital\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiagnostic Analog Outputs (2):\u003c\/strong\u003e \u003cstrong\u003e±10 Vdc into 10k ohm\u003c\/strong\u003e, short-circuit proof to ground. 10-bit resolution. Software-selectable signals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDigital Outputs:\u003c\/strong\u003e 3 on EP-B (8 on EP-I and EP-P). \u003cstrong\u003e150 mA max each\u003c\/strong\u003e, short-circuit proof. Current source from 10-30 Vdc I\/O supply. Opto-isolated.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMotor Temperature Sensor:\u003c\/strong\u003e Compatible with \u003cstrong\u003ePTC thermistor (2k ohm trip point)\u003c\/strong\u003e. Fault turn-on threshold = 0.83V. Reset threshold = 0.41V.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions (FAQ)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What power sources work with the \u003cstrong\u003eEP202-B00-EN00\u003c\/strong\u003e?\u003c\/strong\u003e\u003cbr\u003eA: This drive accepts \u003cstrong\u003e20-264 Vac single phase\u003c\/strong\u003e or \u003cstrong\u003e10-340 Vdc\u003c\/strong\u003e. UL approval for DC input is pending.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Which communication protocols does the \u003cstrong\u003eEP202-B00-EN00\u003c\/strong\u003e support?\u003c\/strong\u003e\u003cbr\u003eA: It supports \u003cstrong\u003eRS-485 Modbus, EtherNet\/IP, Modbus TCP\/IP, and DeviceNet\u003c\/strong\u003e (depending on model variant).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the maximum pulse input frequency?\u003c\/strong\u003e\u003cbr\u003eA: Differential RS422 inputs accept \u003cstrong\u003e1 MHz per channel\u003c\/strong\u003e. Single ended TTL inputs accept \u003cstrong\u003e500 kHz per channel\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: How do I connect a motor temperature sensor?\u003c\/strong\u003e\u003cbr\u003eA: Use a \u003cstrong\u003ePTC thermistor with 2k ohm resistance at trip point\u003c\/strong\u003e. The drive trips at 0.83V and resets at 0.41V.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What software configures the \u003cstrong\u003eEP202-B00-EN00\u003c\/strong\u003e?\u003c\/strong\u003e\u003cbr\u003eA: \u003cstrong\u003ePowerTools Pro\u003c\/strong\u003e software handles all configuration including input debounce and output signal selection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Are the digital outputs short-circuit protected?\u003c\/strong\u003e\u003cbr\u003eA: Yes. All digital outputs are \u003cstrong\u003eshort-circuit proof\u003c\/strong\u003e and current-source type from 10-30 Vdc I\/O power.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-weight: bold;\"\u003e© 2026 Ubest Automation Limited. \u003ca href=\"https:\/\/www.ubestplc.com\/\"\u003ehttps:\/\/www.ubestplc.com\/\u003c\/a\u003e All rights reserved.\u003cbr\u003eContact: \u003ca href=\"mailto:sales@ubestplc.com\"\u003esales@ubestplc.com\u003c\/a\u003e | Phone: \u003ca href=\"https:\/\/wa.me\/8618030005825\"\u003e+86 180 3000 5825\u003c\/a\u003e\u003c\/p\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":52090260422938,"sku":"EP202-B00-EN00","price":253.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/EP202-B00-EN00-1.jpg?v=1776396914","url":"https:\/\/www.ubestplc.com\/products\/ep202-b00-en00-emerson-digital-servo-drive-ac-dc","provider":"Ubest Automation Limited","version":"1.0","type":"link"}