{"product_id":"f2do801-hima-himatrix-f2-do-8-01-safety-related-remote-i-o-module","title":"F2DO801 | HIMA HIMatrix F2 DO 8 01 Safety-Related Remote I\/O Module","description":"\u003ch3\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/h3\u003e\u003cp\u003eThe safety-related F2 DO 8 01 remote I\/O is a compact system in a metal housing with 8 safety-related relay outputs. The remote I\/O is available in various model variants for SILworX and ELOP II Factory.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemote I\/Os Connection:\u003c\/strong\u003e Individual HIMax and HIMatrix controllers via safeethernet.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFunction:\u003c\/strong\u003e Extends the I\/O level but cannot run any user programs independently.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Suitability:\u003c\/strong\u003e Suitable for mounting in Ex-zone 2.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan _mstmutation=\"1\"\u003e\u003cstrong _mstmutation=\"1\"\u003eSafety Certification:\u003c\/strong\u003e Certified by TÜV for safety-related applications up to:\u003c\/span\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSIL 3:\u003c\/strong\u003e IEC 61508, IEC 61511, and IEC 62061\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCat. 4 and PL e:\u003c\/strong\u003e EN ISO 13849-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSIL 4:\u003c\/strong\u003e EN 50126, EN 50128, and EN 50129\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eFurther safety standards, application standards, and test standards are specified in the certificates available on the HIMA website.\u003c\/p\u003e\u003ch3\u003e\u003cstrong\u003eEquipment and Scope of Delivery\u003c\/strong\u003e\u003c\/h3\u003e\u003cp\u003eThe following table specifies the available remote I\/O variants:\u003c\/p\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eDesignation\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eF2 DO 8 01\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRemote I\/O (8 relay outputs up to 250 VAC\/250 VDC), Operating temperature: 0...+60 °C, for ELOP II Factory programming tool\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eF2 DO 8 01 SILworX\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRemote I\/O (8 relay outputs up to 250 VAC\/250 VDC), Operating temperature: 0...+60 °C, for SILworX programming tool\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eF2 DO 8 014 SILworX\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRemote I\/O (8 relay outputs up to 250 VAC\/250 VDC), Operating temperature: -25...+70 °C (temperature class T1), Vibration and shock tested according to EN 50125-3 and EN 50155, class 1B according to IEC 61373, for SILworX programming tool\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003e\u003cstrong\u003eProduct Data for F2 DO 8 014\u003c\/strong\u003e\u003c\/h3\u003e\u003cp\u003eThe F2 DO 8 014 model variant is intended for use in railway applications. The electronic components are coated with a protective lacquer.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e -25…+70 °C (temperature class T1)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 1.3 kg\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003e\u003cstrong\u003eCertified HIMatrix F2 DO 8 01\u003c\/strong\u003e\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eCertifications:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE:\u003c\/strong\u003e EMC, ATEX Zone 2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTÜV:\u003c\/strong\u003e\u003cul\u003e\n\u003cli\u003eIEC 61508 1-7:2000 up to SIL 3\u003c\/li\u003e\n\u003cli\u003eIEC 61511:2004\u003c\/li\u003e\n\u003cli\u003eEN ISO 13849-1:2008 up to Cat. 4 und PL e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan _mstmutation=\"1\"\u003e\u003cstrong _mstmutation=\"1\"\u003eUL:\u003c\/strong\u003e Underwriters Laboratories Inc.\u003c\/span\u003e\u003cul\u003e\n\u003cli\u003eANSI\/UL 508, NFPA 70 – Industrial Control Equipment\u003c\/li\u003e\n\u003cli\u003eCSA C22.2 No.142\u003c\/li\u003e\n\u003cli\u003eUL 1998 Software Programmable Components\u003c\/li\u003e\n\u003cli\u003eNFPA 79 Electrical Standard for Industrial Machinery\u003c\/li\u003e\n\u003cli\u003eIEC 61508\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFM Approvals:\u003c\/strong\u003e\u003cul\u003e\n\u003cli\u003eClass I, DIV 2, Groups A, B, C and D\u003c\/li\u003e\n\u003cli\u003eClass 3600, 1998\u003c\/li\u003e\n\u003cli\u003eClass 3611, 1999\u003c\/li\u003e\n\u003cli\u003eClass 3810, 1989 Including Supplement #1, 1995\u003c\/li\u003e\n\u003cli\u003eCSA C22.2 No. 142\u003c\/li\u003e\n\u003cli\u003eCSA C22.2 No. 213\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTÜV CENELEC Railway Applications:\u003c\/strong\u003e\u003cul\u003e\n\u003cli\u003eEN 50126: 1999 up to SIL 4\u003c\/li\u003e\n\u003cli\u003eEN 50128: 2001 up to SIL 4\u003c\/li\u003e\n\u003cli\u003eEN 50129: 2003 up to SIL 4\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"HIMA","offers":[{"title":"Default Title","offer_id":49268507443482,"sku":"F2DO801","price":76.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/F2DO801.jpg?v=1719651716","url":"https:\/\/www.ubestplc.com\/products\/f2do801-hima-himatrix-f2-do-8-01-safety-related-remote-i-o-module","provider":"Ubest Automation Limited","version":"1.0","type":"link"}