{"product_id":"fx1s-10mt-001-mitsubishi-plc-transistor-output-compact-controller","title":"FX1S-10MT-001 Mitsubishi PLC | Transistor Output Compact Controller","description":"\u003ch2\u003e\n\u003cstrong\u003eFX1S-10MT-001\u003c\/strong\u003e – Compact PLC with High-Speed Capabilities\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eRuns on \u003cspan style=\"background: #fff3bf; font-weight: 600; padding: 0 2px; border-radius: 4px;\"\u003eAC 100–240V\u003c\/span\u003e power supply with wide tolerance (85–264V).\u003c\/li\u003e\n\u003cli\u003eDelivers \u003cspan style=\"background: #fff3bf; font-weight: 600; padding: 0 2px; border-radius: 4px;\"\u003e6 sink-type inputs\u003c\/span\u003e and \u003cspan style=\"background: #fff3bf; font-weight: 600; padding: 0 2px; border-radius: 4px;\"\u003e4 transistor sink outputs\u003c\/span\u003e (0.5A per point).\u003c\/li\u003e\n\u003cli\u003eUses stored program iterative calculation method with interrupt instructions.\u003c\/li\u003e\n\u003cli\u003eBuilt-in EEPROM memory stores up to \u003cspan style=\"background: #fff3bf; font-weight: 600; padding: 0 2px; border-radius: 4px;\"\u003e2000 steps\u003c\/span\u003e without battery backup.\u003c\/li\u003e\n\u003cli\u003eSupports \u003cspan style=\"background: #fff3bf; font-weight: 600; padding: 0 2px; border-radius: 4px;\"\u003e2-axis independent positioning\u003c\/span\u003e with maximum output frequency of \u003cstrong\u003e100 kHz\u003c\/strong\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eKey Technical Specifications \u0026amp; Performance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Mitsubishi Electric | \u003cstrong\u003eModel:\u003c\/strong\u003e FX1S-10MT-001 | \u003cstrong\u003eSeries:\u003c\/strong\u003e FX1S compact PLC series.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArithmetic speed:\u003c\/strong\u003e Basic instructions execute in \u003cspan style=\"background: #fff3bf; font-weight: 600; padding: 0 2px; border-radius: 4px;\"\u003e0.55 to 0.7 μs\u003c\/span\u003e; application instructions from 3.7 μs to several hundred μs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated I\/O:\u003c\/strong\u003e 6 input points (X000–X005) and 4 transistor output points (Y000–Y003). Total I\/O capacity fixed at 30 points maximum.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-speed counters:\u003c\/strong\u003e Supports 1-phase 60 kHz, 2-phase 30 kHz counting (C235–C255). Ideal for encoder feedback or high-speed positioning.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePulse output \/ positioning:\u003c\/strong\u003e Independent 2 axes with PLSY, PLSR, ZRN, DRVI, DRVA instructions. Maximum \u003cspan style=\"background: #fff3bf; font-weight: 600; padding: 0 2px; border-radius: 4px;\"\u003e100 kHz\u003c\/span\u003e pulse train output.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReal-time clock:\u003c\/strong\u003e Built-in calendar (1980–2079) with leap year correction; holds time for 10 days after 30-min charge.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection \u0026amp; memory:\u003c\/strong\u003e Password protection via keyword function; EEPROM keeps critical data (counters, data registers) for at least 5 minutes of consecutive power-on to ensure reliable storage.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDetailed Device Specifications\u003c\/h3\u003e\n\u003ch3\u003ePower \u0026amp; Environmental Ratings\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupply voltage:\u003c\/strong\u003e 100–240 VAC (+10% \/ -15%), 50\/60 Hz. Withstands momentary power interruption ≤10 ms.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower consumption:\u003c\/strong\u003e 19 W (including internal 24 VDC service supply, 400 mA capacity).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient temperature:\u003c\/strong\u003e Operating range 0 to 55 °C; storage -20 to 70 °C. Humidity 35–85% RH non-condensing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVibration \u0026amp; shock resistance:\u003c\/strong\u003e Meets IEC 61131-2 standards; 147 m\/s² impact resistance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDielectric strength \u0026amp; insulation:\u003c\/strong\u003e AC 1.5 kV between power and ground; 5 MΩ insulation resistance at 500 VDC.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Can I expand I\/O on the FX1S-10MT-001?\u003c\/strong\u003e No, the FX1S-10MT-001 has fixed I\/O (6 inputs\/4 outputs). It does not support extension modules.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Does the PLC retain programs during power loss?\u003c\/strong\u003e Yes, the built-in EEPROM retains the user program and selected keep devices without battery. For reliable EEPROM keep, energize the PLC for at least 5 consecutive minutes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the maximum high-speed counter frequency?\u003c\/strong\u003e 1-phase up to 60 kHz (C235\/C236), 2-phase up to 30 kHz. The total processed frequency sum must not exceed 60 kHz when using multiple high-speed counters.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: How do I adjust input filter time?\u003c\/strong\u003e Modify special register D8020 from 0 to 15 ms in 1 ms steps. A setting of 0 provides ultra-fast response (10 μs for X000\/X001).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Can I use the built-in analog volume timers?\u003c\/strong\u003e Yes, two analog timers (VR1: D8030, VR2: D8031) with range 0–255 allow adjustable timer setpoints without external components.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What programming languages does the FX1S support?\u003c\/strong\u003e Relay symbol method, step ladder, and SFC (Sequential Function Chart) representation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e© 2026 Ubest Automation Limited. \u003ca href=\"https:\/\/www.ubestplc.com\/\" rel=\"noopener noreferrer\" target=\"_blank\"\u003ehttps:\/\/www.ubestplc.com\/\u003c\/a\u003e All rights reserved.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eContact:\u003c\/strong\u003e \u003ca href=\"mailto:sales@ubestplc.com\"\u003esales@ubestplc.com\u003c\/a\u003e | \u003ca href=\"https:\/\/wa.me\/8618030005825?text=Inquiry%20about%20FX1S-10MT-001\" rel=\"noopener noreferrer\" target=\"_blank\"\u003e+86 180 3000 5825\u003c\/a\u003e (WhatsApp)\u003c\/p\u003e","brand":"Mitsubishi","offers":[{"title":"Default Title","offer_id":51872155631898,"sku":"FX1S-10MT-001","price":245.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/FX1S-10MT-001-1.jpg?v=1774578363","url":"https:\/\/www.ubestplc.com\/products\/fx1s-10mt-001-mitsubishi-plc-transistor-output-compact-controller","provider":"Ubest Automation Limited","version":"1.0","type":"link"}