Get a Quick Quote for Honeywell XNX-UTSE-NHIC1 Universal Transmitter
Manufacturer:
Honeywell
Product No.:
XNX-UTSE-NHIC1
Condition:
In Stock
Product Type:
Universal Transmitter
Product Origin:
USA
Weight:
6500g
Shipping port:
Xiamen
Warranty:
12 months
UBEST – Trusted Global Automation Parts Supplier
We offer a wide range of in-stock industrial automation spare parts. All products come with a 12-month warranty and a 30-day refund for quality issues.
Honeywell XNX-UTSE-NHIC1 Industrial Carbon Dioxide Transmitter Overview
The XNX-UTSE-NHIC1 universal transmitter provides reliable continuous monitoring for carbon dioxide levels in challenging offshore and onshore facilities.
Executive Summary
- Engineers design the Honeywell XNX-UTSE-NHIC1 to deliver robust toxic gas detection across extreme marine and petrochemical operations.
- This transmitter features heavy-duty 316 stainless steel construction to resist severe chemical corrosion and aggressive salty atmospheric elements.
- The integrated infrared sensor detects precise carbon dioxide concentrations ranging from 0 to 5% Volume across harsh fields.
- Plant operators utilize the local HART protocol interface to streamline field maintenance and perform quick non-intrusive calibration routines daily.
- Global industrial sites rely on the UL and CSA safety certifications to ensure maximum operational safety and project compliance.
Model Code Breakdown
-
Honeywell XNX Series Architecture
- XNX: Universal Gas Transmitter Platform
- U: Approvals - UL/CSA Certified for North American Hazardous Locations
- T: Conduit Entry Type - 3/4" NPT Thread Standard
- S: Enclosure Material - Heavy-Duty 316 Stainless Steel
- E: Personality Board - Electrochemical Cartridge Interface (Includes IS Barrier & Adaptor)
- N: Factory Option - Standard Unit with No Optional Relay Installed
- H: Local Interface - Local HART Communication Port Supported
- IC1: Sensor Element - Infrared Carbon Dioxide Cartridge (0 to 5% Vol Range)
- XNX: Universal Gas Transmitter Platform
Technical Specifications
- Brand Identity: Honeywell Process Solutions produces this equipment for industrial critical safety and plant automation systems worldwide.
- Model Identifier: The exact manufacturing part number for this industrial order is XNX-UTSE-NHIC1 gas transmitter.
- Measurement Technology: The infrared sensor module captures exact carbon dioxide levels between 0 and 5% Volume accurately.
- Response Time Performance: The internal optical sensing mechanism achieves a rapid T90 response time in less than 30 seconds.
- Signal Resolution Accuracy: The digital controller maintains exceptional reading precision down to 0.01% Vol CO2 during continuous operation.
- Full Scale Linearity: The factory calibrated transmitter delivers precise linear measurement within ±2% of full scale limit.
- Environmental Resistance: The sealed mechanical body functions reliably in ambient temperatures from -40°C to +65°C outdoors.
- Interference Mitigation: Advanced double-path infrared optics block common chemical poisons and eliminate environmental cross-sensitivity risks effectively.
- Mechanical Properties: The rugged 316 stainless steel enclosure weighs approximately 6.8 kg (15 lbs) for heavy installations.
Installation Guidelines
- Mount the heavy metal housing securely onto a rigid flat surface or structural steel pipe frame using approved hardware.
- Route field wiring through the pre-cut 3/4" NPT conduit entries using certified explosion-proof cable glands or sealed metal conduits.
- Connect standard three-wire 4-20mA signal lines and point-to-point HART network cables according to official engineering terminal diagrams carefully.
- Seal all unused enclosure entry ports with heavy threaded plug accessories to preserve strict IP66 liquid protection standards.
- Ground the outer stainless steel housing structure locally to shield internal electrical circuits from heavy electromagnetic radiation interference.
Packaging and Shipping Details
- Factory box contains one pre-configured base transmitter body alongside the designated infrared carbon dioxide sensor cartridge unit.
- Logistics team packs every heavy instrument inside high-density protective foam boxes to absorb harsh shipping impacts completely.
- We ship all international industrial orders rapidly through premium global carrier channels like FedEx, UPS, and DHL Express.
Frequently Asked Questions
-
Does this specific transmitter configuration include internal alarm output relays?
- No, the letter N in the model code indicates that factory workers installed no optional relay board inside.
-
Can technicians perform field calibrations without opening the heavy metal cover?
- Yes, field crews use the magnetic wand tool or local HART communicator to adjust settings safely in hazardous spaces.
-
What physical housing material protects the internal electrical sensor components?
- Honeywell manufactures this enclosure with high-grade 316 stainless steel to withstand severe chemical and offshore environments.
© 2026 Ubest Automation Limited. https://www.ubestplc.com/ All rights reserved.
Contact: Email sales@ubestplc.com Phone +86 86 180 3000 5825