{"product_id":"hima-f-3334-f3334-4-fold-output-module","title":"HIMA F 3334 \/ F3334 4 Fold Output Module","description":"\u003ch3\u003eKey Features:\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFunction\u003c\/strong\u003e: Safety-related 4-fold output module designed for handling resistive and inductive loads up to 2 A (48 W) and lamp connections up to 25 W.\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan _mstmutation=\"1\"\u003e\u003cstrong _mstmutation=\"1\"\u003eSafety Mechanisms\u003c\/strong\u003e:\u003c\/span\u003e\u003cul\u003e\n\u003cli\u003eIntegrated safety shutdown\u003c\/li\u003e\n\u003cli\u003eSafe isolation\u003c\/li\u003e\n\u003cli\u003eLine monitoring\u003c\/li\u003e\n\u003cli\u003eNo output signal upon L- supply break\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan _mstmutation=\"1\"\u003e\u003cstrong _mstmutation=\"1\"\u003eAutomatic Testing\u003c\/strong\u003e: Continuously tested during operation, including:\u003c\/span\u003e\u003cul\u003e\n\u003cli\u003eReading back output signals with an operating point for 0 signal read back at ≤ 6.5 V\u003c\/li\u003e\n\u003cli\u003eSwitching capability and cross-talk detection (walking-bit test)\u003c\/li\u003e\n\u003cli\u003eLine monitoring\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eSpecifications:\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutputs\u003c\/strong\u003e: 2 A, short circuit proof\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInternal Voltage Drop\u003c\/strong\u003e: Maximum 2 V at 2 A load\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdmissible Line Resistance\u003c\/strong\u003e: Maximum 3.6 Ohm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUndervoltage Tripping\u003c\/strong\u003e: At ≤ 16 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShort Circuit Current\u003c\/strong\u003e: 2.6 to 5 A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLine Break Current\u003c\/strong\u003e: 0.5 to 9.5 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Leakage Current\u003c\/strong\u003e: Maximum 550 µA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Voltage if Reset\u003c\/strong\u003e: Maximum 1.5 V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Input WD\u003c\/strong\u003e: Maximum 30 mA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest Signal Duration\u003c\/strong\u003e: Maximum 250 µs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpace Requirement\u003c\/strong\u003e: 4 TE\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan _mstmutation=\"1\"\u003e\u003cstrong _mstmutation=\"1\"\u003eOperating Data\u003c\/strong\u003e:\u003c\/span\u003e\u003cul\u003e\n\u003cli\u003e5 V DC: 130 mA\u003c\/li\u003e\n\u003cli\u003e24 V DC: 130 mA in additional load\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eAdditional Notes:\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLine Break Monitoring\u003c\/strong\u003e: Requires a minimum load of 10 mA. The signal \"line break\" can be used in user programs up to requirement class 3.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannel Operation\u003c\/strong\u003e: Only two channels may operate at the maximum load (2 A) simultaneously. If the load is up to 1 A, all channels can operate simultaneously.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIO Rack Usage\u003c\/strong\u003e: Up to 10 output modules with nominal load can be used in one IO rack.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eParallel Operation\u003c\/strong\u003e: Can be paralleled without the need for external diodes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSoftware Integration\u003c\/strong\u003e: Appertaining software building block HB-BLD-. For current version details, refer to the operating system description.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInrush Current Handling\u003c\/strong\u003e: Potential issues with certain 25 W lamp types due to high inrush current can be mitigated by setting a suppression time (1 to 50 ms) at the building block HB-BLD-. This extends the test duration by the set time if this input is occupied.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003ePlanning Considerations:\u003c\/h4\u003e\u003cul\u003e\n\u003cli\u003eEnsure line break monitoring with a minimum load of 10 mA.\u003c\/li\u003e\n\u003cli\u003eFor maximum load operation, limit to two channels concurrently; otherwise, all channels can run with loads up to 1 A each.\u003c\/li\u003e\n\u003cli\u003eIn IO racks, restrict to a maximum of 10 output modules with nominal load.\u003c\/li\u003e\n\u003cli\u003eWhen using certain 25 W lamps, set inrush current suppression time to avoid faults.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eThis module provides robust and safe operation for managing various load types, with comprehensive safety features and automatic testing to ensure reliability and efficiency in critical applications.\u003c\/p\u003e","brand":"HIMA","offers":[{"title":"Default Title","offer_id":48939704975642,"sku":"F-3334","price":120.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/F3334_2.jpg?v=1717412193","url":"https:\/\/www.ubestplc.com\/products\/hima-f-3334-f3334-4-fold-output-module","provider":"Ubest Automation Limited","version":"1.0","type":"link"}