{"product_id":"honeywell-10300-1-1-dc-dc-converter-module","title":"Honeywell 10300\/1\/1 DC\/DC Converter Module","description":"\u003ch3\u003eHoneywell 10300\/1\/1 24 Vdc to 5 Vdc\/12 A Converter Module\u003c\/h3\u003e\u003cp\u003eThe Honeywell \u003cstrong\u003e10300\/1\/1\u003c\/strong\u003e DC\/DC converter is designed to convert a 24 Vdc supply voltage to an internal 5 Vdc, which is used to power FSC system modules. This converter ensures galvanic isolation between the input and output voltages, providing reliable and safe operation for industrial applications.\u003c\/p\u003e\u003cp\u003e\u003cimg alt=\"10300\/1\/1 DC\/DC Converter\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/Honeywell-10300-1-1_480x480.png?v=1719972759\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003c\/p\u003e\u003ch3\u003eKey Features:\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGalvanic Isolation\u003c\/strong\u003e: Ensures isolation between 24 Vdc input and 5 Vdc output.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Current Output\u003c\/strong\u003e: Delivers up to 12 A at 5 Vdc.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInrush Current Limiting\u003c\/strong\u003e: Equipped with an NTC resistor to limit inrush current.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact Design\u003c\/strong\u003e: Optimized for space-saving installations.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications:\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eGeneral\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eType Number\u003c\/strong\u003e: 10300\/1\/1 04603\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApprovals\u003c\/strong\u003e: CE, TÜV, UL\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSoftware Versions\u003c\/strong\u003e: All\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpace Requirements\u003c\/strong\u003e: 8 TE, 3 HE (8 HP, 3U)\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003ePower Requirements\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent\u003c\/strong\u003e: \u0026lt; 3.9 A at 24 Vdc\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage\u003c\/strong\u003e: 24 Vdc (–15% to +30%)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInrush Current\u003c\/strong\u003e: \u0026lt; 18 A\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eEnvironmental Conditions\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient Temperature\u003c\/strong\u003e: 0°C to 60°C (32°F to 140°F)\u003c\/li\u003e\n\u003cli\u003e(See derating curve, Figure 3)\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eOutput Specifications\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Voltage\u003c\/strong\u003e: 5 Vdc with overvoltage protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRipple Content\u003c\/strong\u003e: \u0026lt; 40 mV p-p (at full load)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Current\u003c\/strong\u003e:\n\u003cul\u003e\n\u003cli\u003e12 A at 0°C to 45°C (32°F to 113°F)\u003c\/li\u003e\n\u003cli\u003e8 A at 0°C to 60°C (32°F to 140°F)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHold-up Time\u003c\/strong\u003e: ≥ 0 ms\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Voltage Setting (V adj)\u003c\/strong\u003e: 5.00 Vdc measured across system bus connections\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOvervoltage Protection (OVP adj)\u003c\/strong\u003e: 5.75 Vdc\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEfficiency\u003c\/strong\u003e: ≥ 70%\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eNotes\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eKeep 10300\/1\/1 modules off-line for at least 30 seconds after being on-line. Modules have an NTC resistor as an inrush current limiter. Replacing or repowering the module within 30 seconds after removal or power-off may cause a supply voltage dip which may trip the system because the NTC resistor did not yet cool down sufficiently.\u003c\/li\u003e\n\u003cli\u003eFor 10300\/1\/1 modules without a suffix code, the output LED may remain on in redundant configurations with single I\/O, even if the 10300\/1\/1 is switched off (LED is energized by a redundant 10300\/1\/1 unit).\u003c\/li\u003e\n\u003cli\u003e10300\/1\/1 modules with suffix code 04602 or less are not CE-approved.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":49284541382938,"sku":"10300\/1\/1","price":30.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/1030011_1.jpg?v=1719887419","url":"https:\/\/www.ubestplc.com\/products\/honeywell-10300-1-1-dc-dc-converter-module","provider":"Ubest Automation Limited","version":"1.0","type":"link"}