{"product_id":"honeywell-fc-puio01-safety-universal-io-module","title":"Honeywell FC-PUIO01 Safety Universal IO Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Honeywell \u003cstrong\u003eFC-PUIO01\u003c\/strong\u003e Safety Universal I\/O Module is a versatile component of the Honeywell Universal Marshalling Solution (UMS). It supports a wide range of signal types, including analog, digital, and HART, making it suitable for various safety-related applications. Rated for Safety Integrity Level (SIL) 3, the FC-PUIO01 ensures high reliability and safety in critical systems such as emergency shutdowns, fire alarms, gas detection, and burner management. With 32 channels and compatibility with 24VDC power supply, it offers enhanced flexibility and scalability in industrial environments.\u003c\/p\u003e\u003ch2\u003eSupported Modules\u003c\/h2\u003e\u003ch3\u003eSafety Manager SC - FC-PUIO01 Safety Universal I\/O Module\u003c\/h3\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eFC-PUIO01\u003c\/strong\u003e: SC Safety Universal I\/O Module, 24VDC, 32 Channels\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eSupported Hardware\u003c\/h2\u003e\u003cp\u003eThis section details the hardware support restrictions and considerations.\u003c\/p\u003e\u003ch3\u003e2.1.1 Safety Manager SC Hardware\u003c\/h3\u003e\u003cp\u003eSafety Manager R210.2 supports the following Safety Manager SC Controller components:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFC-PDIO01\u003c\/strong\u003e: SC Safety DIO IOM, 24VDC, 32 Channels\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFC-TDIO11\u003c\/strong\u003e: SC IOTA PDIO Redundant\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFC-TDIO51\u003c\/strong\u003e: SC Safety FTA Knife, EOL, 24VDC, 16 Channels, Left\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFC-TDIO52\u003c\/strong\u003e: SC Safety FTA Knife, EOL, 24VDC, 16 Channels, Right\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFC-PUIO01\u003c\/strong\u003e: SC Safety UIO IOM, 24VDC, 32 Channels\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFC-TUIO11\u003c\/strong\u003e: SC IOTA Safety UIO Redundant\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFC-TUIO51\u003c\/strong\u003e: SC FTA FC-PUIO01 Knife, EOL, 24VDC, 16 Channels, Left\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFC-TUIO52\u003c\/strong\u003e: SC FTA FC-PUIO01 Knife, EOL, 24VDC, 16 Channels, Right\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003chr\u003e\u003ch2\u003eKnown Issues and Resolutions\u003c\/h2\u003e\u003ch3\u003eAnomalies Resolved\u003c\/h3\u003e\u003cp\u003eThe following table indicates anomalies resolved in the FC-PUIO01 firmware compared to Safety Manager R210.1:\u003c\/p\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003ePAR #\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eAbstract\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSMSC-7792\u003c\/td\u003e\n\u003ctd\u003eEC201 of FC-PUIO01 not displayed correctly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSMSC-7794\u003c\/td\u003e\n\u003ctd\u003eBoth FC-PUIO01 modules status LED doesn't blink in Red when any one of CP power cycled\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSMSC-7882\u003c\/td\u003e\n\u003ctd\u003eAnalog input and output HART device-tree in Honeywell FDM may not be displayed correctly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSMSC-7896\u003c\/td\u003e\n\u003ctd\u003eThe “Last status change” timestamp on Safety Builder Remote IO page is not correct for FC-PUIO01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSMSC-7957\u003c\/td\u003e\n\u003ctd\u003eDuring FC-PUIO01 module replacement, open loops, short circuit and PV shifts observed on AI and DI_LM channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSMSC-7974\u003c\/td\u003e\n\u003ctd\u003eFC-PUIO01 module reported EC95 on DO channel for Inductive Load during module replacement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSMSC-7992\u003c\/td\u003e\n\u003ctd\u003eFDM reports load failure due to parity error issue for FC-PUIO01 module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSMSC-8014\u003c\/td\u003e\n\u003ctd\u003eFC-PUIO01 LEDs not operational during startup\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSMSC-8043\u003c\/td\u003e\n\u003ctd\u003eEC62 getting reported during redundant module turning on\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSMSC-8106\u003c\/td\u003e\n\u003ctd\u003eFC-PUIO01 stops on redundant module power-up reported with error code EC30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eUnresolved Anomalies\u003c\/h3\u003e\u003cp\u003eThe following table indicates known issues that still exist for the FC-PUIO01 module:\u003c\/p\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003ePAR #\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eAbstract\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSMSC-7164\u003c\/td\u003e\n\u003ctd\u003eFor systems with more than one IO module in the power supply group, FC-RUSIO-3224 and FC-PUIO01 may not localize earth faults on Digital Output channels.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSMSC-7517\u003c\/td\u003e\n\u003ctd\u003eAny single Ethernet cable fault on FC-PUIO01 sets both RIOLA and RIOLB system markers faulty for this module.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSMSC-7778\u003c\/td\u003e\n\u003ctd\u003eNuisance EC228 can be observed during an online modification if the module lacks IO network cross-wiring between redundant CPs.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSMSC-7134\u003c\/td\u003e\n\u003ctd\u003eIntermittent Earth Fault on DI_LM channel in the same power supply group may report EC63\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSMSC-7419\u003c\/td\u003e\n\u003ctd\u003ePower cycle of FC-RUSIO-3224 with Analog Output channels and connected device may report EC58\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSMSC-7709\u003c\/td\u003e\n\u003ctd\u003ePower cycling FC-PDIO01 or FC-PUIO01 module during OLM may report EC102, EC95 for redundant modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSMSC-7779\u003c\/td\u003e\n\u003ctd\u003eAdding AI with load on a spare channel of FC-PUIO01 may report EC62\/EC63 after an application OLM. Fault reset clears EC62\/EC63\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1-C7PBD6H\u003c\/td\u003e\n\u003ctd\u003eNon-redundant FC-RUSIO-3224 or FC-PUIO01 AI and DI-LM channels may prevent the AI or DI-LM from reaching trip set point due to \"current limiter\" circuitry fault.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003chr\u003e\u003ch2\u003eCertification\u003c\/h2\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eStandard\u003c\/strong\u003e: EN\/ISO 13849-1\u003c\/li\u003e\u003c\/ul\u003e\u003ch3\u003eConfigurations\u003c\/h3\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eSafety Manager Controller or Safety Manager SC Controller\u003c\/strong\u003e connected with FC-RUSIO-3224, FC-PDIO01, or FC-PUIO01.\u003c\/li\u003e\u003c\/ul\u003e\u003ch3\u003eDescriptions \u0026amp; Conditions\u003c\/h3\u003e\u003cp\u003eTo comply with the EN\/ISO 13849-1 standard:\u003c\/p\u003e\u003col\u003e\n\u003cli\u003eDigital input signals allocated to FC-RUSIO-3224, FC-PDIO01, or FC-PUIO01 must be configured as Line Monitored Digital Input.\u003c\/li\u003e\n\u003cli\u003eDigital output signals allocated to these modules must have shielded field wiring.\u003c\/li\u003e\n\u003c\/ol\u003e\u003chr\u003e\u003ch2\u003eSoftware Version Identification\u003c\/h2\u003e\u003ch3\u003eHoneywell Components\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eComponent\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eVersion\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eCRC\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\u003ctr\u003e\n\u003ctd\u003eSafety Universal IO (FC-PUIO01)\u003c\/td\u003e\n\u003ctd\u003e210.2.0.234\u003c\/td\u003e\n\u003ctd\u003e0xFA4FD028\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\u003chr\u003e\u003cp\u003eThis structured format provides a comprehensive overview of the supported hardware, resolved issues, unresolved anomalies, certification compliance, and software version identification for the Honeywell Safety Manager Software R210.2.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":49334755590426,"sku":"FC-PUIO01","price":80.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/FC-PUIO01_1.jpg?v=1720755942","url":"https:\/\/www.ubestplc.com\/products\/honeywell-fc-puio01-safety-universal-io-module","provider":"Ubest Automation Limited","version":"1.0","type":"link"}