{"product_id":"honeywell-tc-odd321-experion-dc-output-module","title":"Honeywell TC-ODD321 Experion DC Output Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe 24 VDC, 32-Point Discrete Output Module is engineered for reliable performance in industrial automation systems. It offers a high-density output configuration with 32 outputs, organized in groups of 16 points per common, and ensures robust and efficient control for various output devices.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Output Capacity\u003c\/strong\u003e: Supports 32 discrete outputs, divided into 16 points per common, ideal for complex automation needs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWide Output Voltage Range\u003c\/strong\u003e: Operates within a 10-31.2 VDC range at 50°C with linear derating, ensuring flexibility and reliability in diverse conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfigurable Fault and Program States\u003c\/strong\u003e: Allows setting fault states and program mode states to Hold Last State, ON, or OFF for each point, providing enhanced control and safety.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Outputs\u003c\/strong\u003e: 32 (16 points\/common)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Voltage Range\u003c\/strong\u003e:\n\u003cul\u003e\n\u003cli\u003e10-31.2 VDC @ 50°C (Linear derating)\u003c\/li\u003e\n\u003cli\u003e10-28 VDC @ 60°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Current Rating\u003c\/strong\u003e:\n\u003cul\u003e\n\u003cli\u003ePer Point: 0.5A maximum @ 50°C (Linear derating), 0.35A maximum @ 60°C\u003c\/li\u003e\n\u003cli\u003ePer Module: 16A maximum @ 50°C (Linear derating), 10A maximum @ 60°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSurge Current\u003c\/strong\u003e: 1A for 10ms each, repeatable every 2s @ 60°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlash On Time\u003c\/strong\u003e: 100 µsec target, 150 µsec max\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOn-State Current Load (Minimum)\u003c\/strong\u003e: 3.0 mA per output\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOn-State Voltage Drop (Maximum)\u003c\/strong\u003e:\n\u003cul\u003e\n\u003cli\u003e1 VDC @ rated current per point\u003c\/li\u003e\n\u003cli\u003e3 VDC for IEC 1131-2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOff-State Leakage Current (Maximum)\u003c\/strong\u003e:\n\u003cul\u003e\n\u003cli\u003e0.5 mA per point\u003c\/li\u003e\n\u003cli\u003e1 mA per point for IEC 1131-2 for 0.25 A output\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eConfigurable Settings\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFault States per Point\u003c\/strong\u003e: Configurable to Hold Last State, ON, or OFF (default OFF)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStates in Program Mode per Point\u003c\/strong\u003e: Configurable to Hold Last State, ON, or OFF (default OFF)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eProtection and Safety\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFusing\u003c\/strong\u003e: Not protected. It is recommended to use Fused IFM to protect outputs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReverse Polarity Protection\u003c\/strong\u003e: None. Incorrect wiring may damage outputs.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eOutput Delay Time\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOff to On\u003c\/strong\u003e: 1.0 ms maximum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOn to Off\u003c\/strong\u003e: 1.0 ms maximum\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003ePower Dissipation\u003c\/h3\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eMaximum Power Dissipation\u003c\/strong\u003e: 6.1 W\u003c\/li\u003e\u003c\/ul\u003e\u003ch3\u003eBackplane Current\u003c\/h3\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eReference\u003c\/strong\u003e: See Module Power Consumption Data, page 46.\u003c\/li\u003e\u003c\/ul\u003e\u003ch3\u003eIsolation Voltage\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGroup to Group\u003c\/strong\u003e: 100% tested at 2546V DC for 1 second (250V AC maximum continuous voltage between groups)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUser to System\u003c\/strong\u003e: 100% tested at 2546V DC for 1 second\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eConnection\u003c\/h3\u003e\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eTerminal Blocks\u003c\/strong\u003e: TC-TBCH, 36-position terminal block\u003c\/li\u003e\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":49070810136858,"sku":"TC-ODD321","price":600.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/TC-ODD321_1.jpg?v=1717235644","url":"https:\/\/www.ubestplc.com\/products\/honeywell-tc-odd321-experion-dc-output-module","provider":"Ubest Automation Limited","version":"1.0","type":"link"}