{"product_id":"honeywell-xnx-amav-nhic1-co2-gas-detector","title":"Honeywell XNX-AMAV-NHIC1 CO2 Gas Detector","description":"\u003ch2\u003e\u003cb\u003eHoneywell XNX-AMAV-NHIC1 Carbon Dioxide Gas Detector\u003c\/b\u003e\u003c\/h2\u003e\n\u003cp\u003eEngineers choose the \u003cb\u003eXNX-AMAV-NHIC1\u003c\/b\u003e for industrial carbon dioxide monitoring. Honeywell builds this device to detect gas leaks safely. Plant managers trust the \u003cb\u003eXNX-AMAV-NHIC1\u003c\/b\u003e because it provides continuous safety data.\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eCore Technical Specifications And Performance Parameters\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eManufacturer:\u003c\/b\u003e Honeywell\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eSeries:\u003c\/b\u003e XNX Universal Transmitters\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eModel Number:\u003c\/b\u003e \u003cb\u003eXNX-AMAV-NHIC1\u003c\/b\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eMeasurement Range:\u003c\/b\u003e 0 to 5 percent volume carbon dioxide\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eFrequency Response:\u003c\/b\u003e 3 Hertz update rate\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eSensitivity:\u003c\/b\u003e 0.05 percent volume gas shift\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eLinearity:\u003c\/b\u003e Plus or minus 0.3 percent deviation\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eResolution:\u003c\/b\u003e 0.01 percent volume steps\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eTemperature Range:\u003c\/b\u003e -40°C to 65°C operating span\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eEnvironmental Tolerance:\u003c\/b\u003e IP66 dust and water resistance\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eInterference Immunity:\u003c\/b\u003e High ambient light rejection\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eVoltage Rating:\u003c\/b\u003e 16 to 32 VDC power supply\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eMaximum Power Consumption:\u003c\/b\u003e 7.2 Watts limit\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eSignal Accuracy:\u003c\/b\u003e Plus or minus 1 percent full scale\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eOutput Signal:\u003c\/b\u003e 4-20 mA with HART protocol\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eKey Product Selling Points\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eHousing Material:\u003c\/b\u003e Painted aluminum alloy\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eSensor Type:\u003c\/b\u003e MPD infrared carbon dioxide sensor\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eCable Entries:\u003c\/b\u003e Three M25 threaded ports\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eLocal Interface:\u003c\/b\u003e Built-in local HART connection port\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eApproval Standard:\u003c\/b\u003e ATEX and IECEx certified safety build\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eInstallation Guide And Packing List\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eMounting Steps:\u003c\/b\u003e Secure the metal housing firmly using wall mounting lugs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eWiring Setup:\u003c\/b\u003e Route power cables through the M25 entries safely.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003ePacking List:\u003c\/b\u003e Includes one transmitter unit and quick setup guide.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eShipping Details And Warranty Terms\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eCourier Services:\u003c\/b\u003e We ship global orders via FedEx, UPS, and DHL.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eWarranty Policy:\u003c\/b\u003e Every purchase includes a standard 12 months warranty term.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eManual Download Guide\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eUser Manual:\u003c\/b\u003e Download official documentation \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/XNX_Universal_Transmitter.pdf?v=1787797330\"\u003ehere\u003c\/a\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eFrequently Asked Questions\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eWhat gas does this specific model detect?\u003c\/b\u003e The unit detects carbon dioxide within a zero to five percent range.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eWhich hazardous area certifications apply here?\u003c\/b\u003e Certified build standards include ATEX, IECEx, and INMETRO approvals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eWhat material protects the electronic components?\u003c\/b\u003e Painted aluminum alloy shields internal parts from harsh elements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eHow do technicians configure local settings?\u003c\/b\u003e Users access parameters through the local HART interface port.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eWhat couriers deliver industrial purchase orders?\u003c\/b\u003e Reliable shipping providers like FedEx, UPS, and DHL deliver packages.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003e© 2026 Ubest Automation Limited. \u003ca href=\"https:\/\/www.ubestplc.com\/\"\u003ehttps:\/\/www.ubestplc.com\/\u003c\/a\u003e All rights reserved.\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eContact: Email \u003ca href=\"mailto:sales@ubestplc.com\"\u003esales@ubestplc.com\u003c\/a\u003e Phone \u003ca href=\"https:\/\/wa.me\/8618030005825\"\u003e+86 180 3000 5825\u003c\/a\u003e\u003c\/b\u003e\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52745783902490,"sku":"XNX-AMAV-NHIC1","price":263.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/XNX-AMSE-NHNNN_8d64a470-80c9-4bc4-8e52-1ba2b02ca0ae.jpg?v=1787798922","url":"https:\/\/www.ubestplc.com\/products\/honeywell-xnx-amav-nhic1-co2-gas-detector","provider":"Ubest Automation Limited","version":"1.0","type":"link"}