{"product_id":"honeywell-xnx-amav-nhif1-propane-transmitter-specs","title":"Honeywell XNX-AMAV-NHIF1 Propane Transmitter Specs","description":"\u003ch2\u003e\u003cstrong\u003eHoneywell XNX-AMAV-NHIF1 Propane Gas Detector Review\u003c\/strong\u003e\u003c\/h2\u003e\n\n\u003ch3\u003e\u003cstrong\u003eOverview and Product Summary\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eEngineered for harsh industrial sites, the \u003cstrong\u003eHoneywell XNX-AMAV-NHIF1\u003c\/strong\u003e universal transmitter detects propane gas leaks safely. Teams rely on this \u003cstrong\u003eHoneywell\u003c\/strong\u003e device for continuous plant safety monitoring. The rugged transmitter protects workers in demanding hazardous locations every single day.\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHoneywell\u003c\/strong\u003e designs this advanced detector for extreme industrial plants.\u003c\/li\u003e\n  \u003cli\u003eOperators deploy the \u003cstrong\u003eXNX-AMAV-NHIF1\u003c\/strong\u003e to track dangerous propane gas leaks instantly.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eCore Technical Parameters\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Honeywell\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e XNX-AMAV-NHIF1\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMeasurement Range:\u003c\/strong\u003e \u003cspan style=\"color:#d9534f;\"\u003e0 to 100 percent LEL propane\u003c\/span\u003e\n\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFrequency Response:\u003c\/strong\u003e \u003cspan style=\"color:#0275d8;\"\u003eRapid signal processing for fast leak detection\u003c\/span\u003e\n\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSensitivity:\u003c\/strong\u003e \u003cspan style=\"color:#5cb85c;\"\u003eHigh response accuracy for tiny gas concentrations\u003c\/span\u003e\n\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLinearity:\u003c\/strong\u003e \u003cspan style=\"color:#f0ad4e;\"\u003eStable linear output across the full measurement span\u003c\/span\u003e\n\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eResolution:\u003c\/strong\u003e \u003cspan style=\"color:#d9534f;\"\u003eFine increments ensure precise gas readings\u003c\/span\u003e\n\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTemperature Range:\u003c\/strong\u003e \u003cspan style=\"color:#0275d8;\"\u003eOperates effectively in extreme industrial climates\u003c\/span\u003e\n\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEnvironmental Tolerance:\u003c\/strong\u003e \u003cspan style=\"color:#5cb85c;\"\u003eBuilt with marine grade aluminum for harsh outdoor zones\u003c\/span\u003e\n\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInterference Resistance:\u003c\/strong\u003e \u003cspan style=\"color:#f0ad4e;\"\u003eAdvanced filtering blocks common site electrical noise\u003c\/span\u003e\n\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOperating Voltage:\u003c\/strong\u003e \u003cspan style=\"color:#d9534f;\"\u003eEighteen to thirty-two volts DC nominal power supply\u003c\/span\u003e\n\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSignal Output:\u003c\/strong\u003e \u003cspan style=\"color:#0275d8;\"\u003eHART over three-wire four to twenty milliamp loop\u003c\/span\u003e\n\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIP Rating:\u003c\/strong\u003e \u003cspan style=\"color:#5cb85c;\"\u003eIP sixty-six weather protection rating\u003c\/span\u003e\n\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHumidity Limit:\u003c\/strong\u003e \u003cspan style=\"color:#f0ad4e;\"\u003eZero to ninety-nine percent relative humidity non-condensing\u003c\/span\u003e\n\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePressure Range:\u003c\/strong\u003e \u003cspan style=\"color:#d9534f;\"\u003eEighty to one hundred twenty kilopascals\u003c\/span\u003e\n\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAir Speed Limit:\u003c\/strong\u003e \u003cspan style=\"color:#0275d8;\"\u003eZero to six meters per second air velocity\u003c\/span\u003e\n\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eUnit Weight:\u003c\/strong\u003e \u003cspan style=\"color:#5cb85c;\"\u003eFive kilograms total device weight\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eHardware Configuration Structure\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eApproval Rating:\u003c\/strong\u003e \n    \u003cul\u003e\n      \u003cli\u003eATEX and IECEx certified for global hazardous zones\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEntry Type:\u003c\/strong\u003e \n    \u003cul\u003e\n      \u003cli\u003eFive M25 threaded ports for secure cable routing\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHousing Material:\u003c\/strong\u003e \n    \u003cul\u003e\n      \u003cli\u003eMarine grade aluminum alloy with five-coat painted finish\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePersonality Board:\u003c\/strong\u003e \n    \u003cul\u003e\n      \u003cli\u003eMilli-volt sensor interface for infrared propane detection\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCommunication Options:\u003c\/strong\u003e \n    \u003cul\u003e\n      \u003cli\u003eLocal HART interface and optional Modbus RS-485 protocol\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eInstallation Guide\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eTechnicians mount the transmitter securely to rigid walls or structural pipes.\u003c\/li\u003e\n  \u003cli\u003eInstallers run certified cables through the designated M25 threaded port entries.\u003c\/li\u003e\n  \u003cli\u003eField engineers connect power wires to the internal terminal blocks carefully.\u003c\/li\u003e\n  \u003cli\u003eTeams configure the HART communication settings before launching system operations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eStandard Package Contents\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOne Honeywell universal gas transmitter unit\u003c\/li\u003e\n  \u003cli\u003eIntegrated infrared propane sensor component\u003c\/li\u003e\n  \u003cli\u003eFactory calibration and technical documentation sheets\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eShipping and Logistics\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eLogistics teams dispatch orders using reliable couriers like FedEx, UPS, and DHL.\u003c\/li\u003e\n  \u003cli\u003eProtective packaging safeguards sensitive electronic components during global transit.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eTechnical Documentation Download\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOperators can download the official manual here: \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/XNX_Universal_Transmitter.pdf?v=1787797330\" target=\"_blank\"\u003eDownload XNX Universal Transmitter Manual\u003c\/a\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eWhat power supply voltage does this detector require during normal operation? The unit requires eighteen to thirty-two volts DC input power.\u003c\/li\u003e\n  \u003cli\u003eHow many cable entry ports are available on the transmitter housing? The rugged aluminum housing features five distinct threaded cable entry ports.\u003c\/li\u003e\n  \u003cli\u003eWhat maximum air velocity can this gas detector withstand safely? The sensor operates accurately in air speeds reaching up to six meters per second.\u003c\/li\u003e\n  \u003cli\u003eDoes this device support digital communication protocols beyond standard analog loops? Operators can utilize optional Modbus over RS-485 alongside standard HART signals.\u003c\/li\u003e\n  \u003cli\u003eWhat is the total physical weight of the packaged transmitter unit? The complete metal transmitter unit weighs exactly five kilograms in total.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\n  \u003cstrong\u003e© 2026 Ubest Automation Limited. \u003ca href=\"https:\/\/www.ubestplc.com\/\" target=\"_blank\"\u003ehttps:\/\/www.ubestplc.com\/\u003c\/a\u003e All rights reserved.\u003c\/strong\u003e\u003cbr\u003e\n  \u003cstrong\u003eContact: Email \u003ca href=\"mailto:sales@ubestplc.com\"\u003esales@ubestplc.com\u003c\/a\u003e Phone \u003ca href=\"https:\/\/wa.me\/8618030005825\" target=\"_blank\"\u003e+86 180 3000 5825\u003c\/a\u003e\u003c\/strong\u003e\n\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52745784230170,"sku":"XNX-AMAV-NHIF1","price":248.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/XNX-AMSE-NNNNN_2dd7eabf-50e0-456d-af50-ca2c35257d65.jpg?v=1787799028","url":"https:\/\/www.ubestplc.com\/products\/honeywell-xnx-amav-nhif1-propane-transmitter-specs","provider":"Ubest Automation Limited","version":"1.0","type":"link"}