{"product_id":"honeywell-xnx-amav-nhiv1-gas-detector-industrial-transmitter","title":"Honeywell XNX-AMAV-NHIV1 Gas Detector - Industrial Transmitter","description":"\u003ch2\u003e\u003cstrong\u003eHoneywell XNX-AMAV-NHIV1 Industrial Methane Gas Detector\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eEngineers build the \u003cstrong\u003eHoneywell XNX-AMAV-NHIV1\u003c\/strong\u003e transmitter to track volatile methane levels inside dangerous plant locations. This dynamic unit from the \u003cstrong\u003eHoneywell\u003c\/strong\u003e XNX Universal Transmitter series keeps industrial operators safe from sudden gas leaks. Download the full technical specs in the \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/XNX_Universal_Transmitter.pdf?v=1787797330\"\u003eXNX Universal Transmitter Instruction Manual\u003c\/a\u003e today.\u003c\/p\u003e\n\n\u003ch3\u003e\u003cstrong\u003eKey Features and Value Highlights\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eInfrared sensor optics deliver precise methane monitoring without interference from ambient weather.\u003c\/li\u003e\n  \u003cli\u003ePainted aluminum enclosure protects internal circuitry from severe chemical erosion and mechanical impacts.\u003c\/li\u003e\n  \u003cli\u003eLocal HART communication ports speed up daily routine tests for on-site field technicians.\u003c\/li\u003e\n  \u003cli\u003eGlobal ATEX and IECEx safety approvals guarantee safe execution in hazardous operating environments.\u003c\/li\u003e\n  \u003cli\u003eFast internal processors give quick signal feedback to prevent catastrophic industrial plant accidents.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eModel Breakdown\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHoneywell\u003c\/strong\u003e XNX Universal Transmitter Series\u003c\/li\u003e\n  \u003cli\u003e└── \u003cstrong\u003eXNX-AMAV-NHIV1\u003c\/strong\u003e Specific Part Number Configuration\n    \u003cul\u003e\n      \u003cli\u003e├── Approval: \u003cstrong\u003eA\u003c\/strong\u003e (ATEX \/ IECEx Approved)\u003c\/li\u003e\n      \u003cli\u003e├── Entry Type: \u003cstrong\u003eM\u003c\/strong\u003e (3 x M25 Threaded Entries)\u003c\/li\u003e\n      \u003cli\u003e├── Housing Material: \u003cstrong\u003eA\u003c\/strong\u003e (Painted Aluminum Alloy)\u003c\/li\u003e\n      \u003cli\u003e├── Personality: \u003cstrong\u003eV\u003c\/strong\u003e (m-Volt Sensor Wiring Interface)\u003c\/li\u003e\n      \u003cli\u003e├── Option: \u003cstrong\u003eN\u003c\/strong\u003e (No Relay Options Installed)\u003c\/li\u003e\n      \u003cli\u003e├── Local Interface: \u003cstrong\u003eH\u003c\/strong\u003e (Local HART Port Included)\u003c\/li\u003e\n      \u003cli\u003e└── Sensor \u0026amp; Range: \u003cstrong\u003eIV1\u003c\/strong\u003e (MPD Methane IR Sensor 0-100% LEL)\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eComplete Technical Parameters\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eBrand Name: \u003cstrong\u003eHoneywell\u003c\/strong\u003e\n\u003c\/li\u003e\n  \u003cli\u003eModel Code: \u003cstrong\u003eXNX-AMAV-NHIV1\u003c\/strong\u003e\n\u003c\/li\u003e\n  \u003cli\u003eTarget Gas Type: Methane Gas (CH4)\u003c\/li\u003e\n  \u003cli\u003eGas Measurement Range: \u003cspan style=\"color: #0056b3;\"\u003e0-100% LEL (0-5% Volume)\u003c\/span\u003e\n\u003c\/li\u003e\n  \u003cli\u003eSensor Technology Type: Infrared MPD Hydrocarbon Sensor\u003c\/li\u003e\n  \u003cli\u003eSignal Output Range: 4-20mA Signal Output with HART Protocol\u003c\/li\u003e\n  \u003cli\u003eSignal Accuracy Level: \u003cspan style=\"color: #28a745;\"\u003e±1% of Full Scale\u003c\/span\u003e\n\u003c\/li\u003e\n  \u003cli\u003eSignal Linear Scale: \u003cspan style=\"color: #28a745;\"\u003e±0.5% Full Scale Linearity\u003c\/span\u003e\n\u003c\/li\u003e\n  \u003cli\u003eSensor Response Rate: \u003cspan style=\"color: #0056b3;\"\u003eT90 Under 15 Seconds\u003c\/span\u003e\n\u003c\/li\u003e\n  \u003cli\u003eDisplay Sensor Resolution: \u003cspan style=\"color: #0056b3;\"\u003e1% LEL Increments\u003c\/span\u003e\n\u003c\/li\u003e\n  \u003cli\u003eSensor Sensitivity Drift: \u003cspan style=\"color: #28a745;\"\u003eUnder ±2% LEL Per Year\u003c\/span\u003e\n\u003c\/li\u003e\n  \u003cli\u003eOptical Noise Immunity: High Anti-Interference Optical Filters\u003c\/li\u003e\n  \u003cli\u003eWorking Power Range: \u003cspan style=\"color: #0056b3;\"\u003e16 VDC to 32 VDC\u003c\/span\u003e\n\u003c\/li\u003e\n  \u003cli\u003eOperating Temperature Limits: \u003cspan style=\"color: #d9534f;\"\u003e-40°C to 65°C\u003c\/span\u003e (-40°F to 149°F)\u003c\/li\u003e\n  \u003cli\u003eRelative Operating Humidity: \u003cspan style=\"color: #0056b3;\"\u003e0% to 99% Non-Condensing RH\u003c\/span\u003e\n\u003c\/li\u003e\n  \u003cli\u003eEnvironmental Protection Grade: \u003cspan style=\"color: #28a745;\"\u003eIP66 Rated Water Dust Seal\u003c\/span\u003e\n\u003c\/li\u003e\n  \u003cli\u003eThreaded Conduit Ports: 3 x M25 Cable Entries\u003c\/li\u003e\n  \u003cli\u003eEnclosure Case Material: Heavy-Duty Painted Aluminum Alloy\u003c\/li\u003e\n  \u003cli\u003eEquipment Unit Weight: 6.2 lbs (2.8 kg)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eSummary\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eThe \u003cstrong\u003eHoneywell XNX-AMAV-NHIV1\u003c\/strong\u003e gas detection transmitter offers maximum protection against combustible methane leaks.\u003c\/li\u003e\n  \u003cli\u003eEngineers specify this model for its \u003cspan style=\"color: #28a745;\"\u003e±1% accuracy\u003c\/span\u003e and quick 15-second response timing.\u003c\/li\u003e\n  \u003cli\u003eIndustrial sites gain stable 4-20mA HART reporting in extreme weather down to \u003cspan style=\"color: #d9534f;\"\u003e-40°C\u003c\/span\u003e.\u003c\/li\u003e\n  \u003cli\u003eRugged aluminum housings and solid-state infrared optics ensure long service life in dangerous areas.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eField Installation Instructions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eFix the aluminum mounting lugs onto a rigid structural beam or flat wall surface.\u003c\/li\u003e\n  \u003cli\u003ePass external signal wires safely into the chassis through the three M25 threaded entries.\u003c\/li\u003e\n  \u003cli\u003eSeal unused M25 conduit entries with certified flameproof plugs to protect internal circuits.\u003c\/li\u003e\n  \u003cli\u003eWire the internal terminal block connections correctly according to system engineering wiring diagrams.\u003c\/li\u003e\n  \u003cli\u003eVerify input supply voltage remains within the allowed range before powering up the equipment.\u003c\/li\u003e\n  \u003cli\u003eCalibrate the infrared optics during setup to ensure reliable continuous gas detection performance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eStandard Package Contents\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eOriginal \u003cstrong\u003eHoneywell XNX-AMAV-NHIV1\u003c\/strong\u003e transmitter main body unit with HART interface.\u003c\/li\u003e\n  \u003cli\u003eIntegrated MPD Infrared Hydrocarbon Sensor Module tuned specifically for Methane detection.\u003c\/li\u003e\n  \u003cli\u003eCustom protective packaging materials designed to shield electronics from severe shock impacts.\u003c\/li\u003e\n  \u003cli\u003eFast express delivery options available via world carriers like FedEx, UPS, and DHL.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eHow quickly does the optical IR sensor react to sudden methane leaks?\n    \u003cul\u003e\n      \u003cli\u003eThe internal infrared sensor module registers target methane concentrations within fifteen short seconds.\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/li\u003e\n  \u003cli\u003eCan field technicians configure the transmitter without opening the main enclosure?\n    \u003cul\u003e\n      \u003cli\u003eYes, personnel use the local HART interface port for convenient calibration without breaking seals.\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/li\u003e\n  \u003cli\u003eDoes this specific unit measure other flammable gases beside Methane?\n    \u003cul\u003e\n      \u003cli\u003eThe pre-installed MPD IV1 sensor option monitors Methane from 0 to 100% LEL range.\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/li\u003e\n  \u003cli\u003eWhat ambient humidity conditions can this heavy transmitter handle safely?\n    \u003cul\u003e\n      \u003cli\u003eThe robust device functions reliably across full humidity ranges from 0 to 99% RH.\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/li\u003e\n  \u003cli\u003eHow does the optical sensor resist false alarms in dusty environments?\n    \u003cul\u003e\n      \u003cli\u003eAdvanced anti-interference filters eliminate signal noise caused by airborne dust and atmospheric light.\u003c\/li\u003e\n    \u003c\/ul\u003e\n  \u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003e© 2026 Ubest Automation Limited. \u003ca href=\"https:\/\/www.ubestplc.com\/\"\u003ehttps:\/\/www.ubestplc.com\/\u003c\/a\u003e All rights reserved.\u003c\/strong\u003e\u003cbr\u003e\nContact: Email \u003ca href=\"mailto:sales@ubestplc.com\"\u003esales@ubestplc.com\u003c\/a\u003e Phone \u003ca href=\"https:\/\/wa.me\/8618030005825\"\u003e+86 86 180 3000 5825\u003c\/a\u003e\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52745783771418,"sku":"XNX-AMAV-NHIV1","price":163.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/XNX-AMSE-NNNNN_5_d4fd63a6-2871-4d16-bcf0-0b0a15357fac.jpg?v=1787798815","url":"https:\/\/www.ubestplc.com\/products\/honeywell-xnx-amav-nhiv1-gas-detector-industrial-transmitter","provider":"Ubest Automation Limited","version":"1.0","type":"link"}