{"product_id":"honeywell-xnx-amse-nnnnn-xnxxsh1ss-xnx-gas-detector-quote","title":"Honeywell XNX-AMSE-NNNNN\/XNXXSH1SS XNX Gas Detector | Quote","description":"\u003ch2\u003e\u003cb\u003eHoneywell XNX Universal Gas Transmitter and H2S Sensor Kit\u003c\/b\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eSummary\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003eEngineers choose the \u003cb\u003eXNX-AMSE-NNNNN\/XNXXSH1SS\u003c\/b\u003e kit for reliable hydrogen sulfide detection in harsh industrial environments. Honeywell builds this advanced gas monitoring system with a rugged stainless steel housing and modular electrochemical sensor support. Plant operators benefit from simple installation procedures and clear diagnostic tools that minimize system downtime.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eBrand: Honeywell\u003c\/li\u003e\n\u003cli\u003eModel: \u003cb\u003eXNX-AMSE-NNNNN\/XNXXSH1SS\u003c\/b\u003e\n\u003c\/li\u003e\n\u003cli\u003eSeries: XNX Universal Transmitter\u003c\/li\u003e\n\u003cli\u003eCategory: Fixed Gas Detection System\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eTechnical Specifications\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBrand: Honeywell\u003c\/li\u003e\n\u003cli\u003eModel: \u003cb\u003eXNX-AMSE-NNNNN\/XNXXSH1SS\u003c\/b\u003e\n\u003c\/li\u003e\n\u003cli\u003eTarget Gas: Hydrogen sulfide (H2S)\u003c\/li\u003e\n\u003cli\u003eDetection Range: 0 to 15 ppm\u003c\/li\u003e\n\u003cli\u003eResolution: 1 ppm\u003c\/li\u003e\n\u003cli\u003eDefault Range: 15.0 ppm\u003c\/li\u003e\n\u003cli\u003eAccuracy: Less than plus or minus 0.3 ppm\u003c\/li\u003e\n\u003cli\u003eOperating Pressure: 80 kPa to 120 kPa\u003c\/li\u003e\n\u003cli\u003eOperating Air Speed: 0 to 6 meters per second\u003c\/li\u003e\n\u003cli\u003eMinimum Warm-up Time: 60 seconds\u003c\/li\u003e\n\u003cli\u003eTransmitter Weight: 8 kg\u003c\/li\u003e\n\u003cli\u003eCartridge Weight: 0.14 kg\u003c\/li\u003e\n\u003cli\u003eStorage Temperature: 0 to 20 degrees Celsius\u003c\/li\u003e\n\u003cli\u003eStorage Pressure: 70 to 110 kPa\u003c\/li\u003e\n\u003cli\u003eStorage Humidity: 30 to 70 percent relative humidity\u003c\/li\u003e\n\u003cli\u003eStorage Time: 6 months maximum\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eSystem Architecture and Structure\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTransmitter Unit: \u003cb\u003eXNX-AMSE-NNNNN\u003c\/b\u003e\n\u003cul\u003e\n\u003cli\u003eApproval Type: ATEX and IEC compliant\u003c\/li\u003e\n\u003cli\u003eCable Entry: M25 thread standard\u003c\/li\u003e\n\u003cli\u003eEnclosure Material: 316 Stainless Steel\u003c\/li\u003e\n\u003cli\u003eSensor Personality: Interface for electrochemical cartridges with intrinsic safety barrier\u003c\/li\u003e\n\u003cli\u003eCommunication Options: No internal HART option installed\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eSensor Cartridge: \u003cb\u003eXNXXSH1SS\u003c\/b\u003e\n\u003cul\u003e\n\u003cli\u003eProduct Type: Electrochemical gas sensor cartridge\u003c\/li\u003e\n\u003cli\u003eTarget Application: Fixed gas monitoring analytics\u003c\/li\u003e\n\u003cli\u003eTarget Gas: Hydrogen sulfide detection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eInstallation Guide\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the transmitter securely to a rigid vertical surface using appropriate stainless steel brackets.\u003c\/li\u003e\n\u003cli\u003eRoute industrial power and signal cables through the M25 threaded entries carefully.\u003c\/li\u003e\n\u003cli\u003eInsert the \u003cb\u003eXNXXSH1SS\u003c\/b\u003e electrochemical cartridge into the designated sensor housing slot.\u003c\/li\u003e\n\u003cli\u003eTighten all enclosure covers completely to maintain explosion protection integrity in hazardous zones.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003ePackage Contents\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHoneywell XNX Universal Transmitter unit\u003c\/li\u003e\n\u003cli\u003eHydrogen sulfide electrochemical sensor cartridge\u003c\/li\u003e\n\u003cli\u003eTechnical installation manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eShipping and Delivery\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eShipping Carriers: FedEx, UPS, and DHL express services\u003c\/li\u003e\n\u003cli\u003ePackaging: Custom protective foam padding inside heavy-duty cardboard boxes\u003c\/li\u003e\n\u003cli\u003eDispatch Time: Orders ship within two business days after payment confirmation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eFrequently Asked Questions\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eWhat input voltage does this transmitter require for normal operation? The unit operates on standard industrial DC power supplies specified in the user manual.\u003c\/li\u003e\n\u003cli\u003eHow often do technicians need to replace the sensor cartridge? Technicians typically replace the cartridge every twelve to twenty-four months depending on gas exposure levels.\u003c\/li\u003e\n\u003cli\u003eCan operators integrate this detector with standard programmable logic controllers? Plant engineers connect the analog and digital outputs directly to industry standard PLCs easily.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003e© 2026 Ubest Automation Limited. \u003ca href=\"https:\/\/www.ubestplc.com\/\" target=\"_blank\"\u003ehttps:\/\/www.ubestplc.com\/\u003c\/a\u003e All rights reserved.\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eContact: Email \u003ca href=\"mailto:sales@ubestplc.com\"\u003esales@ubestplc.com\u003c\/a\u003e Phone \u003ca href=\"https:\/\/wa.me\/8618030005825\" target=\"_blank\"\u003e+86 86 180 3000 5825\u003c\/a\u003e\u003c\/b\u003e\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52742483640602,"sku":"XNX-AMSE-NNNNN","price":169.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/XNX-AMSE-NHNNN_90cdd6ac-5e14-4789-9013-829f7de82199.jpg?v=1787712229","url":"https:\/\/www.ubestplc.com\/products\/honeywell-xnx-amse-nnnnn-xnxxsh1ss-xnx-gas-detector-quote","provider":"Ubest Automation Limited","version":"1.0","type":"link"}