{"product_id":"honeywell-xnx-btai-mhnnn-transmitter-gas-detector-get-quote","title":"Honeywell XNX-BTAI-MHNNN Transmitter Gas Detector - Get Quote","description":"\u003ch2\u003e\u003cb\u003eHoneywell XNX Universal Transmitter Overview\u003c\/b\u003e\u003c\/h2\u003e\n\u003cp\u003eEngineers rely on the \u003cstrong\u003eHoneywell XNX Universal Transmitter\u003c\/strong\u003e to deliver dependable gas detection across demanding industrial environments. This advanced Honeywell XNX transmitter integrates seamlessly with optical sensors to provide continuous hazardous gas monitoring performance.\u003c\/p\u003e\n\u003ch2\u003e\u003cb\u003eCore Value Proposition and Key Advantages\u003c\/b\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eOur technical team provides instant price quotes and fast global shipping for this \u003cspan style=\"color: #d9534f;\"\u003e\u003cb\u003ehigh-performance gas monitoring device\u003c\/b\u003e\u003c\/span\u003e.\u003c\/li\u003e\n\u003cli\u003ePlant operators choose this universal unit because it simplifies field installation while maintaining \u003cspan style=\"color: #d9534f;\"\u003e\u003cb\u003ehigh signal processing accuracy\u003c\/b\u003e\u003c\/span\u003e.\u003c\/li\u003e\n\u003cli\u003eThe rugged aluminum enclosure protects internal electronics against severe environmental conditions during long-term field operation.\u003c\/li\u003e\n\u003cli\u003eTechnicians easily configure operational parameters through the local HART interface without opening the explosion-proof housing structure.\u003c\/li\u003e\n\u003cli\u003eThis robust transmitter supports multiple communication protocols to streamline integration with existing plant control system architectures.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cb\u003eProduct Model Nomenclature Breakdown\u003c\/b\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eXNX-UTAI-MHNNN\u003c\/b\u003e \/ \u003cb\u003eXNX-BTAI-MHNNN\u003c\/b\u003e Architecture Details:\n\u003cul\u003e\n\u003cli\u003e├── \u003cb\u003eManufacturer:\u003c\/b\u003e Honeywell\u003c\/li\u003e\n\u003cli\u003e├── \u003cb\u003eProduct Family:\u003c\/b\u003e XNX Universal Transmitter Series\u003c\/li\u003e\n\u003cli\u003e├── \u003cb\u003eBase Model Code:\u003c\/b\u003e \u003cb\u003eXNX-UTAI-MHNNN\u003c\/b\u003e (Alternate Ref: \u003cb\u003eXNX-BTAI-MHNNN\u003c\/b\u003e)\u003c\/li\u003e\n\u003cli\u003e├── \u003cb\u003eApproval Rating:\u003c\/b\u003e Code B \/ UL Certified\u003c\/li\u003e\n\u003cli\u003e├── \u003cb\u003eConduit Entry:\u003c\/b\u003e Code T (3\/4\" NPT Threaded Entry)\u003c\/li\u003e\n\u003cli\u003e├── \u003cb\u003eEnclosure Material:\u003c\/b\u003e Code A (Copper-Free Aluminum Alloy)\u003c\/li\u003e\n\u003cli\u003e├── \u003cb\u003ePersonality Interface:\u003c\/b\u003e Code I (Infrared Sensor Interface for Searchline Excel, Searchpoint Optima, and Generic 4-20mA Inputs)\u003c\/li\u003e\n\u003cli\u003e├── \u003cb\u003eOption Board:\u003c\/b\u003e Code M (Modbus RTU Communication Protocol)\u003c\/li\u003e\n\u003cli\u003e├── \u003cb\u003eLocal Diagnostics:\u003c\/b\u003e Code H (Local HART Protocol Interface Port)\u003c\/li\u003e\n\u003cli\u003e└── \u003cb\u003eSensor Configuration:\u003c\/b\u003e Code NNN (None Included \/ Field Selected Sensor)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cb\u003eTechnical Specifications\u003c\/b\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eBrand:\u003c\/b\u003e Honeywell Analytics\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eProduct Model:\u003c\/b\u003e \u003cb\u003eXNX-UTAI-MHNNN\u003c\/b\u003e (Order Code: \u003cb\u003eXNX-BTAI-MHNNN\u003c\/b\u003e)\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eProduct Category:\u003c\/b\u003e Industrial XNX Universal Gas Transmitter\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eMeasuring Range \u0026amp; Target Gas:\u003c\/b\u003e Configurable via field optical sensors (Searchline Excel or Searchpoint Optima) and generic 4-20mA devices.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eSignal Resolution \u0026amp; Linearity:\u003c\/b\u003e High-precision 16-bit analog processing maintains strict \u003cspan style=\"color: #d9534f;\"\u003e\u003cb\u003elinear output correlation\u003c\/b\u003e\u003c\/span\u003e across full scale.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eFrequency Response \u0026amp; Sensitivity:\u003c\/b\u003e Fast real-time signal processing guarantees minimal response lag during rapid gas concentration shifts.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eNoise Immunity \u0026amp; Anti-Interference:\u003c\/b\u003e Industrial EMC shielding protects signal circuits against heavy electromagnetic field interference.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eOperating Temperature Range:\u003c\/b\u003e The transmitter operates reliably within an extended ambient temperature range from \u003cspan style=\"color: #d9534f;\"\u003e\u003cb\u003e-40°C to +65°C (-40°F to +149°F)\u003c\/b\u003e\u003c\/span\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eStorage Temperature Range:\u003c\/b\u003e Storage tolerance spans from -40°C to +75°C (-40°F to +167°F).\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eEnvironmental Humidity Tolerance:\u003c\/b\u003e This field device maintains stable signal transmission under non-condensing relative humidity conditions reaching \u003cspan style=\"color: #d9534f;\"\u003e\u003cb\u003e0-99% RH\u003c\/b\u003e\u003c\/span\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eOperating Pressure Range:\u003c\/b\u003e Designed for atmospheric pressure stability between 90kPa and 110kPa.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003ePhysical Dimensions:\u003c\/b\u003e 16cm x 19.7cm x 11.4cm (6.1\" x 7.8\" x 4.5\").\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eUnit Net Weight:\u003c\/b\u003e Approximately 5.0 kg (11.0 lbs).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cb\u003eField Installation and Mounting Guide\u003c\/b\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eMount the transmitter enclosure onto flat surfaces using the standard integrated heavy-duty mounting lug structures.\u003c\/li\u003e\n\u003cli\u003eField crews can mount the unit on vertical pipes using optional mounting bracket kits for versatile positioning.\u003c\/li\u003e\n\u003cli\u003eConnect three-quarter inch NPT conduit fittings directly into the threaded housing entries for secure wiring protection.\u003c\/li\u003e\n\u003cli\u003eWire the generic four-to-twenty milliamp signal output cable to control room receivers following standard wiring diagrams.\u003c\/li\u003e\n\u003cli\u003eVerify all local HART communication channels before putting the gas detection loop into active operational service.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cb\u003eStandard Packing List and Dispatch Shipping\u003c\/b\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eThe factory packaging box contains one complete Honeywell transmitter unit ready for immediate field installation.\u003c\/li\u003e\n\u003cli\u003eSpecialized foam inserts surround the transmitter body inside the shipping container to prevent structural transport damage.\u003c\/li\u003e\n\u003cli\u003eOur logistics team dispatches your order quickly through trusted international express couriers like \u003cspan style=\"color: #d9534f;\"\u003e\u003cb\u003eFedEx, UPS, and DHL\u003c\/b\u003e\u003c\/span\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cb\u003eFrequently Asked Questions (FAQ)\u003c\/b\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eHART Protocol Support:\u003c\/b\u003e Does this specific transmitter model support direct local HART protocol communication during field routine maintenance procedures?\n\u003cul\u003e\n\u003cli\u003eYes, maintenance technicians access diagnostic data directly through the built-in HART interface port without opening covers.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eExpress International Delivery:\u003c\/b\u003e Which express logistics providers handle international delivery for this heavy industrial gas transmitter product unit?\n\u003cul\u003e\n\u003cli\u003eWe ship all international orders promptly using reliable global freight partners such as FedEx, UPS, and DHL.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003e© 2026 Ubest Automation Limited. \u003ca href=\"https:\/\/www.ubestplc.com\/\"\u003ehttps:\/\/www.ubestplc.com\/\u003c\/a\u003e All rights reserved.\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eContact:\u003c\/b\u003e Email \u003ca href=\"mailto:sales@ubestplc.com\"\u003esales@ubestplc.com\u003c\/a\u003e | Phone \u003ca href=\"https:\/\/wa.me\/8618030005825\"\u003e+86 180 3000 5825\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/XNX.png?v=1787630414\" alt=\"\"\u003e\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52742524928282,"sku":"XNX-BTAI-MHNNN","price":186.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/6240\/4634\/files\/XNX-AMSE-NNNNN_07473af6-625a-4358-8a3a-f8c4a09b649c.jpg?v=1787712534","url":"https:\/\/www.ubestplc.com\/products\/honeywell-xnx-btai-mhnnn-transmitter-gas-detector-get-quote","provider":"Ubest Automation Limited","version":"1.0","type":"link"}